Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Wilderness Environ Med ; 28(2): 108-115, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28506514

RESUMO

OBJECTIVE: To compare the effectiveness of arteriovenous anastomosis (AVA) vs heated intravenous fluid (IVF) rewarming in hypothermic subjects. Additionally, we sought to develop a novel method of hypothermia induction. METHODS: Eight subjects underwent 3 cooling trials each to a core temperature of 34.8±0.6 (32.7 to 36.3°C [mean±SD with range]) by 14°C water immersion for 30 minutes, followed by walking on a treadmill for 5 minutes. Core temperatures (Δtes) and rates of cooling (°C/h) were measured. Participants were then rewarmed by 1) control: shivering only in a sleeping bag; 2) IVF: shivering in sleeping bag and infusion of 2 L normal saline warmed to 42°C at 77 mL/min; and 3) AVA: shivering in sleeping bag and circulation of 45°C warmed fluid through neoprene pads affixed to the palms and soles of the feet. RESULTS: Cold water immersion resulted in a decrease of 0.5±0.5°C Δtes and 1±0.3°C with exercise (P < .01); with an immersion cooling rate of 0.9±0.8°C/h vs 12.6±3.2°C/h with exercise (P < .001). Temperature nadir reached 35.0±0.5°C. There were no significant differences in rewarming rates between the 3 conditions (shivering: 1.3±0.7°C/h, R2 = 0.683; IVF 1.3±0.7°C/h, R2 = 0.863; and AVA 1.4±0.6°C/h, R2 = 0.853; P = .58). Shivering inhibition was greater with AVA but was not significantly different (P = .07). CONCLUSIONS: This study developed a novel and efficient model of hypothermia induction through exercise-induced convective afterdrop. Although there was not a clear benefit in either of the 2 active rewarming methods, AVA rewarming showed a nonsignificant trend toward greater shivering inhibition, which may be optimized by an improved interface.


Assuntos
Anastomose Arteriovenosa , Hipotermia/terapia , Reaquecimento/métodos , Estremecimento/fisiologia , Administração Intravenosa , Adulto , Convecção , Feminino , Humanos , Hipotermia/etiologia , Imersão/efeitos adversos , Masculino , Pessoa de Meia-Idade
2.
Wilderness Environ Med ; 26(3): 412-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26094579

RESUMO

BACKGROUND: Transfusion of cold intravenous fluids (IVF) can exacerbate hypothermia. Civilian and military guidelines recommend heated IVF for hypothermic patients; however, there is currently no ideal IVF heating system for use in resource-limited settings. OBJECTIVE: Development of a system that uses flameless ration heaters (FRH) and an insulated sleeve for the consistent delivery of IVF at physiologically appropriate temperatures (40°-42°C) over the range of ambient conditions typical of the prehospital and wilderness environments. METHODS: The temperatures of 0.9% normal saline (NS) 1-L bags were measured under 3 ambient conditions: 3°C, 10°C, and 20°C. The IVF was placed in an insulated pouch along with a predetermined number of activated FRH (5 FRH for 3°C, 4 FRH for 10°C, and 3 FRH for 20°C) for 10 minutes before removing the FRHs. The insulated IVF bag was drained through 280 cm of intravenous tubing at a flow rate of 77 mL/min. Raw temperature data for internal and delivery temperatures were collected and analyzed. RESULTS: The temperature of the IVF throughout the delivery of 1 L of NS under the 3 ambient conditions was as follows (mean ± SD): at 3°C ambient, 47° ± 2.1°C internal and 42.6°C ± 1.4°C at delivery; at 10°C ambient, 52.3° ± 2.7°C and 45.2° ± 1.6°C; and at 20°C ambient, 45.5° ± 1°C and 39.7° ± 0.7°C. CONCLUSIONS: The IVF heating system described here reliably delivered physiologically appropriate temperature intravenous fluids in 2 of the 3 ambient treatment conditions. With the appropriate number of FRH for the ambient conditions, this system enables the delivery of warmed IVF to provide active warming, which may be clinically beneficial in the prevention and treatment of hypothermia.


Assuntos
Temperatura Alta , Hipotermia/terapia , Medicina Selvagem/métodos , Infusões Intravenosas
3.
Wilderness Environ Med ; 26(2): 173-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25771030

RESUMO

OBJECTIVE: Heat-related illness is a common disease with significant morbidity and mortality. Despite no proven efficacy, application of chemical cold packs (CCP) to the skin overlying the large vessels of the neck, groin, and axillae is a traditional recommended cooling modality. The study objective was to compare the cooling rates of CCP applied to these traditional areas vs the glabrous skin surfaces of the cheeks, palms, and soles in exercise-induced hyperthermia. METHODS: Ten healthy adult male volunteers walked on a treadmill in a heated room (40°±0.5°C) while wearing insulated military overgarments until their esophageal temperatures (Tes) reached 39.2°C. Each participant had three heat stress trials on separate days: no treatment followed by randomly ordered traditional (neck, groin, and axillae) cooling and glabrous skin cooling. RESULTS: With no treatment, Tes remained stable after the first 5 minutes of the heat trial (ΔTes=0.12°±0.07°C/10 min). Traditional cooling followed a linear decline (ΔTes=0.17°±0.04°C/10 min; P<.001). Glabrous cooling enhanced the treatment effect by a steeper decline (ΔTes=0.30°±0.06°C/10 min; P<.001), significantly different from traditional cooling by 2-way analysis of variance (P<.001). CONCLUSIONS: Application of CCP to glabrous skin surfaces was more effective for treating exercise-induced heat stress than the traditional CCP cooling intervention. This novel cooling technique may be beneficial as an adjunctive treatment for heat-related illness in the prehospital environment.


Assuntos
Crioterapia/instrumentação , Exercício Físico/fisiologia , Febre/terapia , Regulação da Temperatura Corporal , Crioterapia/métodos , Temperatura Alta , Humanos , Masculino
4.
J Strength Cond Res ; 26(9): 2558-69, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22076097

RESUMO

Body core cooling via the palm of a hand increases work volume during resistive exercise. We asked: (a) "Is there a correlation between elevated core temperatures and fatigue onset during resistive exercise?" and (b) "Does palm cooling between sets of resistive exercise affect strength and work volume training responses?" Core temperature was manipulated by 30-45 minutes of fixed load and duration treadmill exercise in the heat with or without palm cooling. Work volume was then assessed by 4 sets of fixed load bench press exercises. Core temperatures were reduced and work volumes increased after palm cooling (Control: Tes = 39.0 ± 0.1° C, 36 ± 7 reps vs. Cooling: Tes = 38.4 ± 0.2° C, 42 ± 7 reps, mean ± SD, n = 8, p < 0.001). In separate experiments, the impact of palm cooling on work volume and strength training responses were assessed. The participants completed biweekly bench press or pull-up exercises for multiple successive weeks. Palm cooling was applied for 3 minutes between sets of exercise. Over 3 weeks of bench press training, palm cooling increased work volume by 40% (vs. 13% with no treatment; n = 8, p < 0.05). Over 6 weeks of pull-up training, palm cooling increased work volume by 144% in pull-up experienced subjects (vs. 5% over 2 weeks with no treatment; n = 7, p < 0.001) and by 80% in pull-up naïve subjects (vs. 20% with no treatment; n = 11, p < 0.01). Strength (1 repetition maximum) increased 22% over 10 weeks of pyramid bench press training (4 weeks with no treatment followed by 6 weeks with palm cooling; n = 10, p < 0.001). These results verify previous observations about the effects of palm cooling on work volume, demonstrate a link between core temperature and fatigue onset during resistive exercise, and suggest a novel means for improving strength and work volume training responses.


Assuntos
Temperatura Corporal , Temperatura Baixa , Mãos , Fadiga Muscular/fisiologia , Resistência Física , Treinamento Resistido , Teste de Esforço , Humanos , Masculino , Adulto Jovem
5.
Science ; 331(6019): 906-9, 2011 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-21330544

RESUMO

Black bears hibernate for 5 to 7 months a year and, during this time, do not eat, drink, urinate, or defecate. We measured metabolic rate and body temperature in hibernating black bears and found that they suppress metabolism to 25% of basal rates while regulating body temperature from 30° to 36°C, in multiday cycles. Heart rates were reduced from 55 to as few as 9 beats per minute, with profound sinus arrhythmia. After returning to normal body temperature and emerging from dens, bears maintained a reduced metabolic rate for up to 3 weeks. The pronounced reduction and delayed recovery of metabolic rate in hibernating bears suggest that the majority of metabolic suppression during hibernation is independent of lowered body temperature.


Assuntos
Temperatura Corporal , Metabolismo Energético , Hibernação , Consumo de Oxigênio , Ursidae/fisiologia , Animais , Metabolismo Basal , Feminino , Frequência Cardíaca , Humanos , Masculino , Fatores de Tempo , Ursidae/metabolismo
6.
BMC Neurol ; 8: 14, 2008 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-18474113

RESUMO

BACKGROUND: Many individuals afflicted with multiple sclerosis (MS) experience a transient worsening of symptoms when body temperature increases due to ambient conditions or physical activity. Resulting symptom exacerbations can limit performance. We hypothesized that extraction of heat from the body through the subcutaneous retia venosa that underlie the palmar surfaces of the hands would reduce exercise-related heat stress and thereby increase the physical performance capacity of heat-sensitive individuals with MS. METHODS: Ten ambulatory MS patients completed one or more randomized paired trials of walking on a treadmill in a temperate environment with and without cooling. Stop criteria were symptom exacerbation and subjective fatigue. The cooling treatment entailed inserting one hand into a rigid chamber through an elastic sleeve that formed an airtight seal around the wrist. A small vacuum pump created a -40 mm Hg subatmospheric pressure enviinside the chamber where the palmar surface of the hand rested on a metal surface maintained at 18-22 degrees C. During the treatment trials, the device was suspended from above the treadmill on a bungee cord so the subjects could comfortably keep a hand in the device without having to bear its weight while walking on the treadmill. RESULTS: When the trials were grouped by treatment only, cooling treatment increased exercise durations by 33% (43.6 +/- 17.1 min with treatment vs. 32.8 +/- 10.9 min. without treatment, mean +/- SD, p < 5.0.10-6, paired t-test, n = 26). When the average values were calculated for the subjects who performed multiple trials before the treatment group results were compared, cooling treatment increased exercise duration by 35% (42.8 +/- 16.4 min with treatment vs. 31.7 +/- 9.8 min. without treatment, mean +/- SD, p < 0.003, paired t-test, n = 10). CONCLUSION: These preliminary results suggest that utilization of the heat transfer capacity of the non-hairy skin surfaces can enable temperature-sensitive individuals with MS to extend participation in day-to-day physical activities despite thermally stressful conditions. However, systematic longitudinal studies in larger cohorts of MS patients with specific deficits and levels of disability conducted under a variety of test conditions are needed to confirm these preliminary findings.


Assuntos
Temperatura Corporal/fisiologia , Crioterapia/métodos , Mãos/fisiologia , Temperatura Alta/efeitos adversos , Esclerose Múltipla/terapia , Resistência Física/fisiologia , Adulto , Temperatura Baixa , Crioterapia/instrumentação , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/fisiopatologia , Desempenho Psicomotor/fisiologia
7.
IEEE Trans Biomed Eng ; 54(2): 225-33, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17278579

RESUMO

Current research on sleep using experimental animals is limited by the expense and time-consuming nature of traditional EEG/EMG recordings. We present here an alternative, noninvasive approach utilizing piezoelectric films configured as highly sensitive motion detectors. These film strips attached to the floor of the rodent cage produce an electrical output in direct proportion to the distortion of the material. During sleep, movement associated with breathing is the predominant gross body movement and, thus, output from the piezoelectric transducer provided an accurate respiratory trace during sleep. During wake, respiratory movements are masked by other motor activities. An automatic pattern recognition system was developed to identify periods of sleep and wake using the piezoelectric generated signal. Due to the complex and highly variable waveforms that result from subtle postural adjustments in the animals, traditional signal analysis techniques were not sufficient for accurate classification of sleep versus wake. Therefore, a novel pattern recognition algorithm was developed that successfully distinguished sleep from wake in approximately 95% of all epochs. This algorithm may have general utility for a variety of signals in biomedical and engineering applications. This automated system for monitoring sleep is noninvasive, inexpensive, and may be useful for large-scale sleep studies including genetic approaches towards understanding sleep and sleep disorders, and the rapid screening of the efficacy of sleep or wake promoting drugs.


Assuntos
Inteligência Artificial , Movimento/fisiologia , Reconhecimento Automatizado de Padrão/métodos , Polissonografia/métodos , Mecânica Respiratória/fisiologia , Sono/fisiologia , Transdutores , Animais , Camundongos , Camundongos Endogâmicos AKR , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos DBA
8.
J Appl Physiol (1985) ; 99(3): 972-8, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15879169

RESUMO

In situations where the accumulation of internal heat limits physical performance, enhanced heat extraction from the body should improve performance capacity. The combined application of local subatmospheric pressure (35-45 mmHg) to an entire hand (to increase blood volume) and a heat sink (18-22 degrees C) to the palmar surface were used to draw heat out of the circulating blood. Subjects walked uphill (5.63 km/h) on a treadmill in a 40 degree C environment. Slopes of the treadmill were held constant during paired experimental trials (with and without the device). Heat extraction attenuated the rate of esophageal temperature rise during exercise (2.1 +/- 0.4 degrees and 2.9 +/- 0.5 degrees C/h, mean +/- SE, with and without the device, respectively; n = 8) and increased exercise duration (46.1 +/- 3.4 and 32.3 +/- 1.7 min with and without the device, respectively; n = 18). Hand cooling alone had little effect on exercise duration (34.1 +/- 3.0, 38.0 +/- 3.5, and 57.0 +/- 6.4 min, for control, cooling only, and cooling, and subatmospheric pressure, respectively; n = 6). In a longer term study, nine subjects participated in two or four trials per week for 8 wk. The individual workloads (treadmill slope) were varied weekly. Use of the device had a beneficial effect on exercise endurance at all workloads, but the benefit proportionally decreased at higher workloads. It is concluded that heat can be efficiently removed from the body by using the described technology and that such treatment can provide a substantial performance benefit in thermally stressful conditions.


Assuntos
Regulação da Temperatura Corporal , Temperatura Baixa , Transferência de Energia , Mãos/irrigação sanguínea , Mãos/fisiopatologia , Transtornos de Estresse por Calor/fisiopatologia , Esforço Físico , Desempenho Psicomotor , Adulto , Aerobiose/fisiologia , Ambiente Controlado , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...