Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Clin Microbiol ; 62(2): e0083623, 2024 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-38206000

RESUMO

HIV is an ongoing global epidemic with estimates of more than a million new infections occurring annually. To combat viral spread, continuous innovations in areas including testing and treatment are necessary. In the United States, the Centers for Disease Control and Prevention recommend that laboratories follow an HIV testing algorithm that first uses a US Food and Drug Administration approved immunoassay to detect antibodies to HIV-1 or HIV-2 as well as HIV-1 p24 antigen in serum or plasma samples. An initially reactive specimen is tested by a supplemental assay for confirmation and to differentiate antibodies to HIV-1 or HIV-2. There are few Food and Drug Administration (FDA)-approved supplemental differentiation tests currently available. A multicenter investigation was conducted to determine the clinical performance for two independent versions of the Avioq VioOne HIV Profile Supplemental Assay (Avioq, Inc., Research Triangle Park, NC). The performance of both assay versions compared favorably with the performance parameters for the Geenius HIV 1/2 Supplemental Assay as published in that assay package insert (Bio-Rad Laboratories, Hercules, CA), the current gold standard for HIV supplemental testing. When comparing the two VioOne assays, version 2 (lacking HIV-2 p27 antibody detection) demonstrated improved reproducibility, specificity, and sensitivity as compared to its predecessor. IMPORTANCE We evaluated the reproducibility, sensitivity, and specificity data for two versions of the VioOne HIV Profile Supplemental Assay and compared these results back to similar results for the Geenius HIV 1/2 Supplemental Assay that are publicly available. Our study concluded that the VioOne HIV Profile Supplemental Assay compared favorably with the Geenius HIV 1/2 Supplemental Assay, thus providing an additional option for clinical laboratories to improve and expand their HIV testing capabilities.


Assuntos
Infecções por HIV , Soropositividade para HIV , HIV-1 , Humanos , Estados Unidos , Reprodutibilidade dos Testes , Anticorpos Anti-HIV , Algoritmos , HIV-2 , Proteína do Núcleo p24 do HIV , Sensibilidade e Especificidade
2.
AIDS ; 36(13): 1890-1893, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36111696

RESUMO

Antibody-based testing for emtricitabine (FTC), a critical component of pre-exposure prophylaxis and antiretroviral therapy, would provide low-cost detection for clinical monitoring to improve adherence. We developed a mAb (5D2) to FTC and demonstrated its high specificity and physiologically relevant linear range of detection in a competitive enzyme immunoassay. Thus, this mAb is a key reagent that will enable simple and low-cost lateral flow assays and enzyme immunoassays for adherence monitoring.


Assuntos
Fármacos Anti-HIV , Infecções por HIV , Profilaxia Pré-Exposição , Fármacos Anti-HIV/uso terapêutico , Antirretrovirais/uso terapêutico , Emtricitabina/uso terapêutico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/prevenção & controle , Humanos , Tenofovir/uso terapêutico
3.
MMWR Morb Mortal Wkly Rep ; 69(3): 63-66, 2020 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-31971928

RESUMO

Since 2014, the recommended laboratory testing algorithm for diagnosing human immunodeficiency virus (HIV) infection has included a supplemental HIV-1/HIV-2 differentiation test to confirm infection type on the basis of the presence of type-specific antibodies (1). Correctly identifying HIV-1 and HIV-2 infections is vital because their epidemiology and clinical management differ. To describe the percentage of diagnoses for which an HIV-1/HIV-2 differentiation test result was reported and to categorize HIV type based on laboratory test results, 2010-2017 data from CDC's National HIV Surveillance System (NHSS) were analyzed. During 2010-2017, a substantial increase in the number of HIV-1/HIV-2 differentiation test results were reported to NHSS, consistent with implementation of the HIV laboratory-based testing algorithm recommended in 2014. However, >99.9% of all HIV infections identified in the United States were categorized as HIV-1, and the number of HIV-2 diagnoses (mono-infection or dual-infection) remained extremely low (<0.03% of all HIV infections). In addition, the overall number of false positive HIV-2 test results produced by the HIV-1/HIV-2 differentiation increased. The diagnostic value of a confirmatory antibody differentiation test in a setting with sensitive and specific screening tests and few HIV-2 infections might be limited. Evaluation and consideration of other HIV tests approved by the Food and Drug Administration (FDA) that might increase efficiencies in the CDC and Association of Public Health Laboratories-recommended HIV testing algorithm are warranted.


Assuntos
Testes Diagnósticos de Rotina/métodos , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-2/isolamento & purificação , Adolescente , Adulto , Algoritmos , Centers for Disease Control and Prevention, U.S. , Feminino , Infecções por HIV/epidemiologia , Humanos , Laboratórios , Masculino , Pessoa de Meia-Idade , Estados Unidos/epidemiologia , Adulto Jovem
4.
Microsyst Nanoeng ; 6: 54, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-34567665

RESUMO

Detection of human immunodeficiency virus (HIV) p24 protein at a single pg/ml concentration in point-of-care (POC) settings is important because it can facilitate acute HIV infection diagnosis with a detection sensitivity approaching that of laboratory-based assays. However, the limit of detection (LOD) of lateral flow immunoassays (LFAs), the most prominent POC diagnostic platform, falls short of that of laboratory protein detection methods such as enzyme-linked immunosorbent assay (ELISA). Here, we report the development and optimization of a thermal contrast amplification (TCA) LFA that will allow ultrasensitive detection of 8 pg/ml p24 protein spiked into human serum at POC, approaching the LOD of a laboratory test. To achieve this aim, we pursued several innovations as follows: (a) defining a new quantitative figure of merit for LFA design based on the specific to nonspecific binding ratio (BR); (b) using different sizes and shapes of gold nanoparticles (GNPs) in the systematic optimization of TCA LFA designs; and (c) exploring new laser wavelengths and power regimes for TCA LFA designs. First, we optimized the blocking buffer for the membrane and running buffer by quantitatively measuring the BR using a TCA reader. The TCA reader interprets the thermal signal (i.e., temperature) of GNPs within the membrane when irradiated by a laser at the plasmon resonance wavelength of the particle. This process results in higher detection and quantitation of GNPs than in traditional visual detection (i.e., color intensity). Further, we investigated the effect of laser power (30, 100, 200 mW), GNP size and shape (30 and 100 nm gold spheres, 150 nm gold-silica shells), and laser wavelength (532, 800 nm). Applying these innovations to a new TCA LFA design, we demonstrated that 100 nm spheres with a 100 mW 532 nm laser provided the best performance (i.e., LOD = 8 pg/ml). This LOD is significantly better than that of the current colorimetric LFA and is in the range of the laboratory-based p24 ELISA. In summary, this TCA LFA for p24 protein shows promise for detecting acute HIV infection in POC settings.

5.
Open Forum Infect Dis ; 5(8): ofy180, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30568989

RESUMO

Prompt determination of HIV infection status is critical during follow-up visits for patients taking pre-exposure prophylaxis (PrEP) medication. Those who are uninfected can then continue safely taking PrEP, and those few who have acquired HIV infection can initiate an effective treatment regimen. However, a few recent cases have been reported of ambiguous HIV test results using common testing algorithms in PrEP patients. We review published reports of such cases and testing options that can be used to clarify true HIV status in these situations. In addition, we review the benefits and risks of 3 antiretroviral management options in these patients: (1) continue PrEP while conducting additional HIV tests, (2) initiate antiretroviral therapy for presumptive HIV infection while conducting confirmatory tests, or (3) discontinue PrEP to reassess HIV status after a brief antiretroviral-free interval. A clinical consultation resource is also provided.

6.
J Virol Methods ; 259: 60-65, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29874550

RESUMO

Real-time PCR assays for nucleic acid testing (NAT) of hepatitis viruses A-E and for HIV-1 and HIV-2 have been developed; however, a multiplex assay that can simultaneously detect all of these agents is not yet available. Standardized TaqMan assays for detection of hepatitis viruses A-E have been described and applied to TaqMan Array Cards (TAC) which are capable of multiple pathogen detection using a single set of optimized PCR conditions. Assays for three gene regions of HIV-1 (long-terminal repeat (LTR), gag, and polymerase) and HIV-2 (overlap of LTR and gag, protease and integrase) were designed using the hepatitis assay conditions. Nucleic acid extracts of HIV-1-infected samples (44 plasma, 41 whole blood, 20 HIV-1 viral stocks) were tested on the TAC cards; 98 were reactive (92%) with 70 in multiple gene regions. Twenty-four of the 27 (89%) HIV-2 specimens (10 plasma, 1 PBMC lysate, 6 whole blood and 10 plasmids containing HIV-2 polymerase) were detected on TAC. No HIV or hepatitis virus sequences were detected in 30 HIV-negative samples (specificity 100%). Three HBV and 18 HCV co-infections were identified in the HIV-1-infected specimens. Multi-pathogen detection using TAC could provide a rapid, sensitive and more efficient method of surveying for a variety of infectious disease nucleic acids.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Vírus de Hepatite/isolamento & purificação , Hepatite Viral Humana/diagnóstico , Análise em Microsséries/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções por HIV/virologia , HIV-1/genética , HIV-2/genética , Vírus de Hepatite/genética , Hepatite Viral Humana/virologia , Sensibilidade e Especificidade , Fatores de Tempo
7.
Nature ; 539(7627): 98-101, 2016 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-27783600

RESUMO

The emergence of HIV-1 group M subtype B in North American men who have sex with men was a key turning point in the HIV/AIDS pandemic. Phylogenetic studies have suggested cryptic subtype B circulation in the United States (US) throughout the 1970s and an even older presence in the Caribbean. However, these temporal and geographical inferences, based upon partial HIV-1 genomes that postdate the recognition of AIDS in 1981, remain contentious and the earliest movements of the virus within the US are unknown. We serologically screened >2,000 1970s serum samples and developed a highly sensitive approach for recovering viral RNA from degraded archival samples. Here, we report eight coding-complete genomes from US serum samples from 1978-1979-eight of the nine oldest HIV-1 group M genomes to date. This early, full-genome 'snapshot' reveals that the US HIV-1 epidemic exhibited extensive genetic diversity in the 1970s but also provides strong evidence for its emergence from a pre-existing Caribbean epidemic. Bayesian phylogenetic analyses estimate the jump to the US at around 1970 and place the ancestral US virus in New York City with 0.99 posterior probability support, strongly suggesting this was the crucial hub of early US HIV/AIDS diversification. Logistic growth coalescent models reveal epidemic doubling times of 0.86 and 1.12 years for the US and Caribbean, respectively, suggesting rapid early expansion in each location. Comparisons with more recent data reveal many of these insights to be unattainable without archival, full-genome sequences. We also recovered the HIV-1 genome from the individual known as 'Patient 0' (ref. 5) and found neither biological nor historical evidence that he was the primary case in the US or for subtype B as a whole. We discuss the genesis and persistence of this belief in the light of these evolutionary insights.


Assuntos
Síndrome da Imunodeficiência Adquirida/história , Síndrome da Imunodeficiência Adquirida/virologia , Genoma Viral/genética , HIV-1/classificação , HIV-1/genética , Síndrome da Imunodeficiência Adquirida/sangue , Síndrome da Imunodeficiência Adquirida/epidemiologia , Teorema de Bayes , HIV-1/isolamento & purificação , História do Século XX , Homossexualidade Masculina/estatística & dados numéricos , Humanos , Masculino , Cidade de Nova Iorque/epidemiologia , América do Norte/epidemiologia , RNA Viral/análise , RNA Viral/genética , RNA Viral/isolamento & purificação , Análise de Sequência de DNA , Análise Espaço-Temporal
8.
PLoS One ; 11(6): e0157709, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27310836

RESUMO

Zoonotic transmission of simian retroviruses in West-Central Africa occurring in primate hunters has resulted in pandemic spread of human immunodeficiency viruses (HIVs) and human T-lymphotropic viruses (HTLVs). While simian foamy virus (SFV) and simian T- lymphotropic virus (STLV)-like infection were reported in healthy persons exposed to nonhuman primates (NHPs) in West-Central Africa, less is known about the distribution of these viruses in Western Africa and in hospitalized populations. We serologically screened for SFV and STLV infection using 1,529 specimens collected between 1985 and 1997 from Côte d'Ivoire patients with high HIV prevalence. PCR amplification and analysis of SFV, STLV, and HIV/SIV sequences from PBMCs was used to investigate possible simian origin of infection. We confirmed SFV antibodies in three persons (0.2%), two of whom were HIV-1-infected. SFV polymerase (pol) and LTR sequences were detected in PBMC DNA available for one HIV-infected person. Phylogenetic comparisons with new SFV sequences from African guenons showed infection likely originated from a Chlorocebus sabaeus monkey endemic to Côte d'Ivoire. 4.6% of persons were HTLV seropositive and PCR testing of PBMCs from 15 HTLV seroreactive persons identified nine with HTLV-1 and one with HTLV-2 LTR sequences. Phylogenetic analysis showed that two persons had STLV-1-like infections, seven were HTLV-1, and one was an HTLV-2 infection. 310/858 (53%), 8/858 (0.93%), and 18/858 (2.1%) were HIV-1, HIV-2, and HIV-positive but undifferentiated by serology, respectively. No SIV sequences were found in persons with HIV-2 antibodies (n = 1) or with undifferentiated HIV results (n = 7). We document SFV, STLV-1-like, and dual SFV/HIV infection in Côte d'Ivoire expanding the geographic range for zoonotic simian retrovirus transmission to West Africa. These findings highlight the need to define the public health consequences of these infections. Studying dual HIV-1/SFV infections in immunocompromised populations may provide a new opportunity to better understand SFV pathogenicity and transmissibility in humans.


Assuntos
Infecções por Deltaretrovirus/diagnóstico , Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , Infecções por Retroviridae/diagnóstico , Vírus Espumoso dos Símios/isolamento & purificação , Animais , Anticorpos Antivirais/sangue , Chlorocebus aethiops , Coinfecção , Côte d'Ivoire/epidemiologia , DNA Viral/genética , Infecções por Deltaretrovirus/epidemiologia , Infecções por Deltaretrovirus/virologia , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , HIV-1/classificação , HIV-1/genética , HIV-2/classificação , HIV-2/genética , HIV-2/isolamento & purificação , Vírus Linfotrópico T Tipo 1 Humano/classificação , Vírus Linfotrópico T Tipo 1 Humano/genética , Vírus Linfotrópico T Tipo 1 Humano/isolamento & purificação , Vírus Linfotrópico T Tipo 2 Humano/classificação , Vírus Linfotrópico T Tipo 2 Humano/genética , Vírus Linfotrópico T Tipo 2 Humano/isolamento & purificação , Humanos , Leucócitos Mononucleares/virologia , Doenças dos Macacos/diagnóstico , Doenças dos Macacos/epidemiologia , Doenças dos Macacos/virologia , Filogenia , Infecções por Retroviridae/epidemiologia , Infecções por Retroviridae/virologia , Vírus Espumoso dos Símios/classificação , Vírus Espumoso dos Símios/genética
9.
J Clin Virol ; 61(2): 293-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25066885

RESUMO

BACKGROUND: Currently, no FDA-approved HIV-2 nucleic acid assay is commercially available in the United States, although several laboratories have developed in-house assays to confirm HIV-2 infections. A major limitation in the development of novel HIV-2 diagnostic assays is the lack of reference materials that can be used to evaluate, optimize, and monitor assay performance. STUDY DESIGN: Eleven viral stocks of HIV-2 isolates from various West African countries, including the Ivory Coast, Senegal, and Guinea-Bissau, were used to clone the entire LTR and pol regions from each virus. RESULTS: We successfully cloned, sequenced, and group classified 22 HIV-2 DNA plasmids including 11 full length LTR (∼849 bp) and 11 pol (∼2995 bp) sequences. There were eight HIV-2 group A and three group B in both the LTR and pol regions. CONCLUSIONS: This reference panel provides a robust, quantifiable, renewable, and non-infectious set of reagents that can be used for the development and evaluation of new HIV-2 molecular diagnostic assays and quality assurance and quality control reagents for use in the clinical laboratories.


Assuntos
Infecções por HIV/diagnóstico , HIV-2/isolamento & purificação , Técnicas de Diagnóstico Molecular/normas , Reação em Cadeia da Polimerase em Tempo Real/normas , Padrões de Referência , DNA Viral/genética , Repetição Terminal Longa de HIV/genética , HIV-2/genética , Humanos , Técnicas de Diagnóstico Molecular/métodos , Plasmídeos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Estados Unidos , Produtos do Gene pol do Vírus da Imunodeficiência Humana/genética
10.
MMWR Morb Mortal Wkly Rep ; 63(10): 209-12, 2014 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-24622284

RESUMO

In August 2012, the Houston Department of Health contacted CDC regarding the rare transmission of human immunodeficiency virus (HIV) likely by sexual contact between two women. The case was investigated, and laboratory testing confirmed that the woman with newly diagnosed HIV infection had a virus virtually identical to that of her female partner, who was diagnosed previously with HIV and who had stopped receiving antiretroviral treatment in 2010. This report describes this case of HIV infection, likely acquired by female-to-female sexual transmission during the 6-month monogamous relationship of the HIV-discordant couple (one negative, one positive). The woman with newly acquired infection did not report any other recognized risk factors for HIV infection, and the viruses infecting the two women had ≥ 98% sequence identity in three genes. The couple had not received any preventive counseling before acquisition of the virus by the woman who had tested negative for HIV. HIV-discordant couples should receive counseling regarding safer sex practices, and HIV-infected partners should be linked to and retained in medical care.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/transmissão , Homossexualidade Feminina , Feminino , Infecções por HIV/epidemiologia , HIV-1/genética , HIV-1/isolamento & purificação , Homossexualidade Feminina/psicologia , Homossexualidade Feminina/estatística & dados numéricos , Humanos , Pessoa de Meia-Idade , Filogenia , Texas/epidemiologia
11.
J Clin Virol ; 58(1): 240-4, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23838670

RESUMO

BACKGROUND: An alternate HIV testing algorithm has been proposed which includes a fourth-generation immunoassay followed by an HIV-1/HIV-2 antibody differentiation supplemental test for reactive specimens and a nucleic acid test (NAT) for specimens with discordant results. OBJECTIVE: To evaluate the performance of five rapid tests (Alere Clearview, Bio-Rad Multispot, OraSure OraQuick, MedMira Reveal, and Trinity Biotech Unigold) as the supplemental antibody assay in the algorithm. STUDY DESIGN: A total of 3273 serum and plasma specimens that were third-generation immunoassay repeatedly reactive and Western blot (WB) negative or indeterminate were tested with rapid tests and NAT. Specimens were classified by NAT: (1) HIV-1 infected (NAT-reactive; n=184, 5.6%), (2) HIV-status unknown (NAT nonreactive; n=3078, 94.2%) or by Multispot, (3) HIV-2 positive (n=5), and (4) HIV-1 and HIV-2 positive (n=6). Excluding HIV-2 positive specimens, we calculated the proportion of reactive rapid tests among specimens with reactive and nonreactive NAT. RESULTS: The proportion of infected specimens with reactive rapid test results and negative or indeterminate WB ranged from 30.4% (56) to 47.8% (88) depending on the rapid test. From 1% to 2% of NAT-negative specimens had reactive rapid test results. CONCLUSIONS: In these diagnostically challenging specimens, all rapid tests identified infections that were missed by the Western blot, but only Multispot could differentiate HIV-1 from HIV-2. Regardless of which rapid test is used as a supplemental test in the alternative algorithm, false-positive algorithm results (i.e., reactive screening and rapid test in uninfected person) may occur, which will need to be resolved during the baseline medical evaluation.


Assuntos
Técnicas de Laboratório Clínico/métodos , Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Algoritmos , Reações Falso-Positivas , HIV-1/genética , HIV-1/imunologia , HIV-2/genética , HIV-2/imunologia , Humanos , Imunoensaio/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos
12.
AIDS Res Hum Retroviruses ; 29(1): 61-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23281586

RESUMO

Laboratory assays for the detection of recent HIV infection for HIV incidence surveillance are essential to HIV prevention efforts worldwide because they can identify populations with a high incidence and allow targeting of resources and monitoring of incidence trends over time. This study describes the development of a novel rapid HIV-1 incidence-prevalence (I-P) test that can be used for the simultaneous detection and discrimination of prevalent (long-term) or incident (recent) HIV infections using a single device. A lateral flow assay was developed that uses a multisubtype recombinant gp41 protein applied at two concentrations of antigen (high and low). Prevalent and incident HIV-1 infections can be distinguished based on differential antibody binding at the two antigen concentrations. High level/high avidity antibodies present in prevalent infections bind to and are detected at both antigen concentrations while low level/low avidity antibodies present in recent HIV infections are detected only at the higher antigen concentration line. A total of 205 HIV-positive specimens with known status (recent=105, long-term=100), including 57 specimens from seroconversion panels, were tested by the rapid I-P assay and the results were compared to the HIV-1 BED capture enzyme immunoassay (CEIA). There was a 95.1% agreement of final classification (recent or long-term) with the BED assay (kappa=0.910) (mean recency period=162 days) and a high correlation between the intensity score of the low antigen line with the BED OD-n (Pearson correlation=0.89). The new rapid I-P test has great potential to simplify HIV surveillance efforts by simultaneously providing information on both HIV prevalence and incidence using a single, rapid test device.


Assuntos
Sorodiagnóstico da AIDS/métodos , Infecções por HIV/diagnóstico , HIV-1/imunologia , Anticorpos Anti-HIV/sangue , Anticorpos Anti-HIV/imunologia , Proteína gp41 do Envelope de HIV/sangue , Proteína gp41 do Envelope de HIV/imunologia , Infecções por HIV/epidemiologia , Infecções por HIV/imunologia , Soropositividade para HIV/diagnóstico , Soropositividade para HIV/imunologia , Humanos , Técnicas Imunoenzimáticas , Incidência , Prevalência , Sensibilidade e Especificidade
13.
Methods Mol Biol ; 903: 263-71, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22782824

RESUMO

This chapter describes a real-time PCR method for the detection of HIV-1 proviral DNA in whole blood samples using a novel double-stranded primer system. The assay utilizes a simple commercially available DNA extraction method and a rapid and easy-to-perform real-time PCR protocol to consistently detect a minimum of four copies of HIV-1 group M proviral DNA in as little as 90 min after sample (whole blood) collection. Co-amplification of the human RNase P gene serves as an internal control to monitor the efficiency of both the DNA extraction and amplification. Once the assay is validated properly, it may be suitable as an alternative confirmation test for HIV-1 infections in a variety of HIV testing venues including the mother-to-child transmission testing sites, clinics, and diagnostic testing centers.


Assuntos
Primers do DNA/genética , DNA Viral/sangue , DNA Viral/genética , HIV-1/genética , Técnicas de Diagnóstico Molecular/métodos , Provírus/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sangue/virologia , DNA Viral/isolamento & purificação , Humanos , Sequências Repetidas Terminais/genética , Fatores de Tempo
14.
J Clin Virol ; 52 Suppl 1: S23-7, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21993309

RESUMO

BACKGROUND: HIV-1 Western blot (WB) may be positive in specimens from persons with HIV-2 infection due to cross-reactive antibodies. HIV-1 and HIV-2 infections may be identified using assays designed to differentiate HIV-1 and HIV-2 antibody reactivity. OBJECTIVES: To evaluate the ability of the current CDC WB criteria, alternative more stringent HIV-1 WB criteria (2 env plus one gag or pol band) and the Multispot HIV-1/HIV-2 Rapid Test to accurately differentiate HIV-1 and HIV-2 infections. STUDY DESIGN: Two panels were used to determine the ability of each method to properly classify HIV-1 and HIV-2 infections: an HIV-2 panel (n=114) determined to be HIV-2 antibody-positive by both Multispot and by a validated HIV-2 WB, and 2135 HIV-1/HIV-2 immunoassay repeatedly reactive (IA-RR) specimens from the New York State Department of Health Laboratory (NYS). RESULTS: By CDC WB criteria, 53 (46.5%) HIV-2 panel specimens were HIV-1 WB positive, 60 (52.6%) were indeterminate, and 1 (0.9%) was negative; the alternative WB criteria re-classified 75.5% of the positives as indeterminate. Among 2135 NYS IA-RR specimens, the alternative WB criteria increased the proportion of indeterminates by 0.8%. Only 6 (0.3%) of the NYS specimens were determined to be HIV-2 infections; all 6 were classified either as HIV-1 positive or indeterminate by both WB criteria, but were classified as HIV-2 (n=4) or HIV-1/2 undifferentiated (n=2) by Multispot. CONCLUSIONS: The alternative WB criteria classified most of the HIV-2 specimens that were HIV-1 positive by CDC criteria as indeterminate, but also slightly increased the proportion of HIV-1 specimens classified as indeterminate. The WB indeterminate specimens would require further testing or follow-up to resolve the infection status, whereas Multispot directly distinguished HIV-1 from HIV-2.


Assuntos
Western Blotting , Infecções por HIV/classificação , Infecções por HIV/diagnóstico , Imunoensaio/métodos , Centers for Disease Control and Prevention, U.S./normas , Reações Cruzadas , Anticorpos Anti-HIV/imunologia , Infecções por HIV/imunologia , Infecções por HIV/virologia , HIV-1/imunologia , HIV-1/patogenicidade , HIV-2/imunologia , HIV-2/patogenicidade , Humanos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Estados Unidos , Produtos do Gene gag do Vírus da Imunodeficiência Humana/genética , Produtos do Gene pol do Vírus da Imunodeficiência Humana/genética
15.
Clin Vaccine Immunol ; 17(6): 1034-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20410326

RESUMO

A simplified lateral-flow assay for the detection of antibodies to HIV using magnetic-bead conjugates and multibranched peptides from both HIV-1 and HIV-2 was developed. Magnetic immunochromatography testing (MICT) uses a standard lateral-flow platform that incorporates magnetic-bead conjugates for quantitative measurement of the magnetic field distortion associated with the bound magnetic conjugate (reported as adjusted relative magnetic units [MAR]). The results of the optimized MICT assay were compared to standard enzyme immunoassay (EIA) and Western blotting (WB) results using a blinded 649-member panel of specimens from the United States, Cameroon, and West Africa. The panel was comprised of samples from individuals infected with various HIV-1 subtypes (n = 234) or HIV-2 (n = 65) and HIV-seronegative specimens (n = 350). Additionally, 13 HIV-1 seroconversion panels (total specimens = 85), a worldwide panel containing seven of the major circulating HIV-1 subtypes (n = 18), an HIV-2 panel, an HIV-1/HIV-2 mixed panel, and 100 prospective specimens were tested with completely concordant results. Assay reproducibility (observed MAR) for both intra- and interrun testing was excellent, with coefficients of variation of <12%. MICT can provide a rapid, low-cost method of determining HIV antibody status requiring no subjective interpretations.


Assuntos
Especificidade de Anticorpos , Anticorpos Anti-HIV/sangue , Antígenos HIV/imunologia , Infecções por HIV/diagnóstico , HIV-1/imunologia , HIV-2/imunologia , Sorodiagnóstico da AIDS , Cromatografia/métodos , Antígenos HIV/química , Infecções por HIV/imunologia , Infecções por HIV/virologia , Separação Imunomagnética/métodos , Peptídeos/imunologia , Fatores de Tempo
16.
J Virol Methods ; 164(1-2): 55-62, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19948189

RESUMO

In this study, a rapid real-time PCR assay to detect HIV-1 proviral DNA in whole blood was developed using a novel double-stranded primer that does not require a target-specific fluorescent probe or intercalating dye systems. Co-amplification of a human gene RNase P served as the internal control to monitor the efficiency of the DNA extraction and PCR amplification. The HIV-1 amplification efficiency was 100% and could amplify 1 copy of HIV-1 DNA 64% of the time and all attempts to amplify 4 copies were successful in less than 51 min. All 22 HIV-1 sero-positive and 20 sero-negative whole blood specimens tested were classified correctly by this assay. In addition, 22 cultured PBMC specimens infected with various HIV-1 subtypes or CRF (A=2, AC=1, B=4, C=3, D=3, AE=2, F=1, BF=2, G=4) were amplified equally well with a similar threshold cycle (C(t)) number (22.9+/-1.2). The high amplification efficiency and short PCR cycles were in part due to the short target sequence amplified by eliminating the probe-binding sequence between the primers. This assay may be useful as an alternative confirmation test in a variety of HIV testing venues.


Assuntos
DNA Viral/isolamento & purificação , HIV-1/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Provírus/isolamento & purificação , Sangue/virologia , DNA/química , DNA/genética , Primers do DNA/química , Primers do DNA/genética , DNA Viral/genética , Infecções por HIV/virologia , HIV-1/genética , Humanos , Leucócitos Mononucleares/virologia , Reação em Cadeia da Polimerase/normas , Provírus/genética , Padrões de Referência , Ribonuclease P/genética , Sensibilidade e Especificidade , Fatores de Tempo
17.
J Acquir Immune Defic Syndr ; 53(1): 117-23, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19710616

RESUMO

OBJECTIVE: To monitor trends in HIV seroprevalence in the United States, HIV testing was included in the National Health and Nutrition Examination Survey (NHANES) conducted from 1999 to 2006. METHODS: From 1999 to 2006, 11,928 participants aged 18­49 years were tested for HIV antibody. Prevalence estimates were weighted to account for over sampling and nonresponse. RESULTS: There were 67 HIV antibody-reactive individuals for a seroprevalence of 0.5% [95% confidence interval (CI) 0.3­0.6]. In the only age subgroup directly comparable between surveys (18­39 years), HIV seroprevalence remained constant from NHANES III(1988­1994) to NHANES 1999­2002 and 2003­2006. In NHANES 1999­2006, non­Hispanic blacks had significantly higher HIV seroprevalence(2.0%, 95% CI 1.5­2.7) compared with individuals in all other race/ethnic groups combined. Seroprevalence was also higher in each race/ethnic group among men who have sex with men (9.4%95% CI 5.0­17.1), among persons who had detectable antibody to herpes simplex type-two (1.9% 95% CI 1.4­2.8), among those who had 50 or more lifetime sex partners (3.4%, 95% CI 1.7­6.7), and among those who never married (0.8%, 95% CI 0.5­1.3). CONCLUSIONS: In this household-based population, seroprevalence did not significantly change from NHANES III to NHANES 1999­2006. Non­Hispanic blacks had significantly higher prevalence of infection compared with other race/ethnic groups. Male-to-male sex and the presence of HSV-2 antibody were the strongest predictors of HIV infection


Assuntos
População Negra/estatística & dados numéricos , Infecções por HIV/epidemiologia , Soroprevalência de HIV/tendências , Homossexualidade Masculina/estatística & dados numéricos , Adolescente , Adulto , Estudos Transversais , Feminino , Anticorpos Anti-HIV/análise , Infecções por HIV/diagnóstico , HIV-2/imunologia , Inquéritos Epidemiológicos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Soroepidemiológicos , Fatores Socioeconômicos , Estados Unidos/epidemiologia , Adulto Jovem
18.
J Virol Methods ; 160(1-2): 14-21, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19482361

RESUMO

Detection of human immunodeficiency virus (HIV) infections has been enhanced by incorporating p24 antigen detection with current HIV antibody detection using enzyme immunoassays (EIAs). However, screening for HIV antibodies has increased through the use of rapid, lateral-flow HIV antibody detection assays that currently do not have the capability to detect HIV p24 antigen. In this report, a lateral-flow based assay using super-paramagnetic particles as the detection marker was developed for the detection of HIV-1 p24 antigen. This magnetic immuno-chromatographic test (MICT) uses an inexpensive, low-maintenance instrument that detects the magnetic moment of the super-paramagnetic particles in a magnetic field. MICT is simple to perform, provides a numerical output for easier determination of reactive results and can be completed in 40min. The lower limit of detection for HIV-1 p24 spiked into assay sample buffer and 50% plasma was 30pg/ml for both. Detection of HIV-1 p24 antigen at 50pg/ml was reproducible in both inter-run and intra-run assays with coefficients of variation of <13%. Furthermore, the MICT p24 assay was able to detect intact virus spiked into 50% plasma (lower detection limit of approximately 250,000 viral RNA copies/ml). MICT detection of increasing HIV-1 p24 levels in commercially available seroconversion panels by MICT was only slightly later than that detected by much more complex EIAs. MICT could provide a simple, low-cost, and portable method for rapid HIV-1 p24 detection in a variety of testing environments.


Assuntos
Antígenos Virais/sangue , Cromatografia/métodos , Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/diagnóstico , Separação Imunomagnética/métodos , Plasma/virologia , Animais , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Expert Rev Anti Infect Ther ; 3(6): 957-69, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16307508

RESUMO

The HIV pandemic continues to expand throughout Africa and southern Asia. Despite recent advances in therapy, the primary means of prevention continues to be the identification of infected patients through diagnostic testing, and the provision of counseling services to reduce HIV transmission. In order to facilitate the identification of infected patients, great strides have been made during the past 10 years towards the development of simple, rapid HIV antibody assays that require no specialized equipment, are relatively stable at ambient temperatures and can be easily performed by people who do not have a laboratory background. Evaluations of these assays have shown that when used in multiple assay algorithm strategies, they perform comparably with current laboratory-based methods. Effective global implementation of these tests will require a concerted effort from public and private health agencies, however, expanding the use of these assays can provide a significant opportunity to slow the devastating spread of HIV.


Assuntos
Surtos de Doenças/prevenção & controle , Anticorpos Anti-HIV/sangue , Infecções por HIV/diagnóstico , HIV-1 , Imunoensaio/métodos , Animais , Anticorpos Anti-HIV/imunologia , Infecções por HIV/epidemiologia , Infecções por HIV/imunologia , Infecções por HIV/prevenção & controle , HIV-1/imunologia , Humanos , Fatores de Tempo
20.
Clin Diagn Lab Immunol ; 12(8): 918-21, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16085908

RESUMO

Assay protocols of three rapid human immunodeficiency virus (HIV) assays, OraQuick-1/2, SeroStrip-1/2, and Determine-1/2, were modified to detect recent HIV seroconversion using a higher dilution of serum specimens. Optimal predilution of specimens resulted in negative test results during early periods of seroconversion (about 6 months), when antibody levels were low. A total of 269 seropositive specimens from routine HIV type 1 testing and from commercial sources (low-titer and seroconversion panels) were tested, and results were recorded as negative (score=0) or positive using intensity scores from 0.5 (weak positive) to 4 (strongly positive). The same specimens were previously tested by a less sensitive (LS) enzyme immunoassay (EIA), Abbott 3A 11-LS, and were classified as recent or long-term infections based on the standardized optical density (SOD) cutoff of 0.75. Overall concordance of >94% was observed between 3A 11-LS and modified rapid tests (RT-LSs) for detecting and distinguishing recent HIV seroconversion from long-term HIV infection (kappa statistics=0.894 to 0.901). Moreover, intensity scores on RT-LSs correlated well with median 3A 11-LS SOD values (R(2)>0.98). Our results indicate that rapid HIV tests can be modified to detect recent seroconversion with results comparable to those from less sensitive EIA.


Assuntos
Anticorpos Anti-HIV/sangue , Infecções por HIV/diagnóstico , Infecções por HIV/imunologia , Soropositividade para HIV/diagnóstico , HIV-1/imunologia , Anticorpos Antivirais/sangue , Soropositividade para HIV/imunologia , Humanos , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Testes Sorológicos/métodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...