Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Case Rep Urol ; 2023: 5706109, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37333788

RESUMO

Penile fracture is a urological emergency, and surgery is usually recommended to prevent complications. However, proximal locations are scarce and not well investigated. We present two rare penile fractures involving the proximal corpora cavernosa with an original conservative strategy to manage this clinical presentation. Twenty-five- and thirty-eight-year-old men with no previous medical history were admitted to the emergency room for penile trauma during sexual intercourse a few months apart. Both presented with "butterfly pattern" ecchymosis with a palpable hematoma on the perineum. They had no hematuria or voiding dysfunction. Ultrasound found a hematoma and a tear of the proximal corpus cavernosum for the younger one. Then, an MRI confirmed a longitudinal fracture of the right corpus cavernosum for the first patient and left for the second, without urethral injury. In agreement with the patients facing this atypical presentation, we proposed a conservative treatment with analgesics, monitoring, and advice to stop sexual activity for three weeks. After six weeks and four weeks, respectively, we performed a clinical evaluation and a second MRI that found no residual tear or hematoma. The IIEF-5 questionnaire was 24/25 and 25/25. The patients were clinically symptom-free at 8 and 11 months of follow-up. Extreme proximal fracture of the corpus cavernosum can be managed conservatively in selected situations. MRI is useful for decision-making by confirming the diagnosis and location to avoid surgery.

2.
Dig Dis Sci ; 67(6): 2462-2470, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34159487

RESUMO

BACKGROUND: The association between radiological remission and natural history of disease in children with inflammatory bowel diseases (IBD) is poorly known. AIMS: (i) To assess the correlation between cross-sectional imaging (CSI) (ultrasound and magnetic resonance imaging) and clinical, biomarker and endoscopic disease activity; (ii) to evaluate the impact of radiological activity on the occurrence of complications in pediatric patients with IBD. METHODS: A retrospective study including pediatric patients with IBD and radiological follow-up of at least one year was conducted between 2003 and 2019 at the Nancy University Hospital. RESULTS: In total, 118 patients (66 Crohn's disease (CD) and 52 ulcerative colitis (UC)) were included. Median follow-up duration was 5.2 years (range: 1.1-15.4). Seventeen (25.8%) patients with CD and 7 (13.5%) patients with UC achieved and maintained radiological remission until last follow-up. No IBD patient achieving radiological remission experienced complications or relapse. In patients not achieving radiologic remission, complications and surgery occurred in 13/49 (26.5%) and 8/49 (16.3%) patients with CD and in 5/45 (11.1%) and 5 (11.1%) subjects with UC. Among patients with CD, the association for remission status between radiological and endoscopic assessment was excellent (Cramer's V test (V) = 0.50), and moderate between radiological and either clinical (V = 0.30) or biochemical (V = 0.33) assessments. In UC, the association for remission status between radiological and either endoscopic or clinical assessments were weak (V = 0.19 and V = 0.20 respectively), and moderate (V = 0.23) between radiological and biochemical assessments. CONCLUSION: CSI may replace endoscopic monitoring in pediatric CD. Radiological remission status predicts long-term disease outcomes.


Assuntos
Colite Ulcerativa , Doença de Crohn , Doenças Inflamatórias Intestinais , Criança , Doença Crônica , Colite Ulcerativa/diagnóstico por imagem , Colite Ulcerativa/epidemiologia , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/epidemiologia , Humanos , Recidiva , Estudos Retrospectivos
3.
Clin Gastroenterol Hepatol ; 20(5): e1040-e1049, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34216820

RESUMO

BACKGROUND & AIMS: We developed and validated a magnetic resonance imaging-based index to predict Crohn's disease (CD) postoperative recurrence (POR). METHODS: Patients with CD who underwent a postoperative evaluation for recurrence (with colonoscopy and MRI no longer than 105 days apart) were included between 2006 and 2016 in University Hospital of Nancy, France. MRI items with good levels of intra-rater and inter-rater agreement (Gwet's coefficient ≥0.5) were selected. The MRI in Crohn's Disease to Predict Postoperative Recurrence (MONITOR) index's performance was assessed in terms of the area under the receiver operating characteristic curve (AUROC) and accuracy, by considering the Rutgeerts score as the gold standard. The MONITOR index was validated with a bootstrap method and an independent cohort. RESULTS: Seventy-three MRI datasets were interpreted by 2 radiologists. Seven items (bowel wall thickness, contrast enhancement, T2 signal increase, diffusion-weighted signal increase, edema, ulcers, and the length of the diseased segment) had a Gwet's coefficient ≥0.5 and were significantly associated with the Rutgeerts score, leading to their inclusion in the MONITOR index. All the items had a weighting of 1, except the "ulcers" item weighting 2.5, reflecting the higher adjusted odds ratio. The AUROC [95% confidence interval] for the prediction of endoscopic POR (Rutgeerts score >i1) was 0.80 [0.70-0.90]. The optimal threshold was a MONITOR index ≥1, giving a sensitivity of 79%, a specificity of 55%, a predictive positive value of 68%, and a predictive negative value of 68%. The bootstrap validation gave an AUROC of 0.85 [0.73-0.97]. In the validation cohort, a MONITOR index ≥1 gave a sensitivity of 87%, a specificity of 75%, a predictive positive value of 84.6%, and a predictive negative value of 75%. CONCLUSIONS: The MONITOR index is an efficient, reliable, easy-to-apply tool that can be used in clinical practice to predict the POR of CD.


Assuntos
Doença de Crohn , Colonoscopia , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Doença de Crohn/cirurgia , Humanos , Imageamento por Ressonância Magnética , Período Pós-Operatório , Recidiva , Índice de Gravidade de Doença , Úlcera
4.
Eur J Radiol ; 127: 108970, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32289628

RESUMO

PURPOSE: To compare the performance of different image reconstruction algorithms in the presence of small metal objects of different sizes and at different dose levels. METHOD: A fresh bone of bovine femur was drilled with seven drill bits of increasing diameter. CT images with eight different dose levels were acquired and reconstructed with three algorithms: hybrid iterative reconstruction - HIR, Full model-based iterative reconstruction - full MBIR and a single energy metal artifact reduction - SEMAR. Trabecular distortion adjacent to metal was evaluated subjectively with a four-point scale. Edge profile artifacts were evaluated quantitatively by measuring drill bit diameter overestimation and the width of the low-density halo surrounding the drill bit. RESULTS: Trabecular distortion was higher with full MBIR compared to HIR and SEMAR (P < 0.0001) and increased with drill bits larger than 1.2 mm and with doses lower than 18.1 mGy.cm. Low-density halos size and drill bit diameter overestimation decreased with full MBIR compared to the other two reconstruction algorithms and with SEMAR compared to HIR (P < 0.0001). There was a mean drill bit overestimation of 0.56 ± 0.25 mm for full MBIR versus 0.68 ± 0.09 mm for SEMAR and mean low-density halo diameters of 0.03 mm ± 0.08 for full MBIR versus 0.42 mm ± 0.09 for SEMAR. CONCLUSION: Algorithm performance is influenced by dose levels and metal object size and no individual algorithm provides the best overall performance. Full MBIR is better in reducing edge artifacts and SEMAR is the best option for larger metal implants and low dose protocols.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Metais , Próteses e Implantes , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Bovinos , Modelos Animais , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...