Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 30(3): 412-7, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17367362

RESUMO

BACKGROUND: In this prospective, randomized, controlled study, we compared the performance of J-shaped active fixation (AF) atrial leads with J-shaped passive fixation (PF) leads, over a 1-year follow-up period. METHODS: A total of 200 consecutive patients were prospectively randomized for implantation with a Medtronic 5568 AF lead model (n = 103; Minneapolis, MN, USA) versus a Medtronic 5592 PF model (n = 97), and all lead-related measurements and complications were recorded over one year. RESULTS: All leads were successfully implanted with a nonsignificant difference in crossover rate to the alternative lead due to failed implantation (1 in the AF and 4 in the PF group, P = NS). Fluoroscopy time during implantation procedure was significantly shorter in the PF group (2.1 +/- 3.6 vs 3.3 +/- 4.5 minute, P < 0.05). Pacing thresholds during implantation were significantly lower in patients with PF leads (0.7 +/- 0.3 V vs 0.9 +/- 0.3 V, P < 0.001) and this difference persisted at 1-year follow-up (0.8 +/- 0.6 V vs 1.3 +/- 0.9 V in PF and AF leads respectively, P < 0.05). Lead-related complications occurred in PF and AF with similar frequency (4% and 9% respectively, P = 0.2). However, pericardial complications occurred only in the AF group (6 cases, P = 0.01). Lead dislodgement was observed in only two cases-both in the PF group (P = 0.3). CONCLUSION: Both types of J-shaped atrial leads had reasonable performance. PF leads required shorter fluoroscopy time for implantation, demonstrated a better pacing threshold over a 1-year follow-up period and had no pericardial complications, while AF lead implantation was complicated by pericardial irritation and/or effusion in 6% cases (P = 0.01).


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/estatística & dados numéricos , Eletrodos Implantados , Marca-Passo Artificial/estatística & dados numéricos , Implantação de Prótese/métodos , Implantação de Prótese/estatística & dados numéricos , Idoso , Estimulação Cardíaca Artificial/métodos , Feminino , Humanos , Israel/epidemiologia , Masculino , Prevalência , Prognóstico , Medição de Risco/métodos , Fatores de Risco , Resultado do Tratamento
2.
Europace ; 8(2): 118-21, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16627421

RESUMO

AIMS: This study assesses short- and long-term performance of the S80TB ventricular lead manufactured by Sorin Biomedica, Italy. METHODS AND RESULTS: Three hundred and thirty leads were implanted and had complete follow-up with us for a minimum of 60 months or up to failure, removal, and/or patient death (mean 40 months, range: 1 day to 81 months). Thirty-two patients (9.6%) had spontaneous lead-related complications: 7 (2.1%) occurred during the first week; 25 (7.6%) had chronic complications, of which 20 (6.1%) necessitated re-operations; 3 (0.9%) were lead material failures. Of the 110 re-operations (90 pacemaker replacements and 20 operations due to complications), 7 additional cases (6.4%) were complicated by unique connector damage that occurred during disconnection of the lead from the connector block. The Kaplan-Meier estimated 5-year lead survival free of lead material failure and free of any significant lead complication were 97.9 and 87%, respectively. CONCLUSION: The S80TB lead demonstrates an acceptable rate of acute and chronic spontaneous complications and very few lead material failures over 5 years of follow-up. However, there seems to be a relatively high incidence of connector damage during disconnection from the connector block. Extra caution is required during those procedures in patients with this lead.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial/efeitos adversos , Fibrilação Ventricular/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrodos Implantados , Desenho de Equipamento , Falha de Equipamento , Análise de Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Fibrilação Ventricular/mortalidade
3.
Isr Med Assoc J ; 6(10): 599-602, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15473586

RESUMO

BACKGROUND: The appearance of pericarditis following insertion of a permanent pacemaker is not widely acknowledged in the literature. OBJECTIVES: To describe our experience with pericarditis following 395 permanent pacemaker implantations over 2 years. METHODS: We retrospectively reviewed the medical records of 395 consecutive patients in whom new pacing systems or pacemaker leads had been implanted over a 2 year period. We searched the records for pericarditis that developed within 1 month after pacemaker implantation according to the ICD-9 code. The incidence, clinical picture, response to treatment, and relationship to lead design and location were studied. RESULTS: Eight cases (2%) of pericarditis following implantation were detected. Clinical manifestations in all patients were similar to those of post-pericardiotomy syndrome and included chest pain (n = 7), friction rub (n = 1), fever (n = 2), fatigue (n = 2), pleural effusion (n = 2), new atrial fibrillation (n = 2), elevated erythrocyte sedimentation rate (n = 4), and echcardiographic evidence of pericardial effusion (n = 8). All affected patients had undergone active fixation (screw-in) lead implantation in the atrial position. The incidence of pericarditis with screw-in atrial leads was 3% compared to 0% in other cases (P < 0.05). CONCLUSIONS: Pericarditis is not uncommon following pacemaker implantation with active fixation atrial leads. Special attention should be paid to identifying pericardial complications following pacemaker implantation, especially when anticoagulant therapy is resumed or initiated. The use of passive fixation leads is likely to reduce the incidence of pericarditis but this issue should be further investigated.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Pericardite/etiologia , Corticosteroides/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios não Esteroides/uso terapêutico , Remoção de Dispositivo , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Pericardite/diagnóstico , Pericardite/epidemiologia , Pericardite/terapia , Estudos Retrospectivos , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 26(12): 2283-8, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14675013

RESUMO

This report describes the experience of a large pacemaker center during three successive replacement operations due to safety alerts involving three models from the same manufacturer. Between March 1993 and May 1999, 210 patients were implanted with three DDD pacemaker models (Sorin Biomedica, Saluggia, Italy) that were subsequently subject to safety alerts. Pacemaker records were reviewed for complications related to device malfunction, and those secondary to the replacement procedure. Pacemaker malfunction was observed in 16.4% of units despite much lower estimates from the company (range 1-4%). With the exception of one, all units were replaced. Malfunctions were discovered in 7 of 20 pacemakers following an urgent call for follow-up issued as a result of the alert. Twenty units implanted as substitutes for those replaced following the first alert turned out to be subject to the third alert. Significant clinical consequences of malfunction occurred in 5.3% of patients including a near fatal event in one case, while complications related to the replacement procedure occurred in 8.3% of patients, including one fatality. On the issuance of a safety alert, failure rates in a particular center may be higher than published by the manufacturer, and should prompt action by the center to weigh local incidence of device failure against complications of replacement procedures. When device failure mechanism is not entirely clear, particularly in cases of successive model failures, replacement devices from a different manufacturer should be considered.


Assuntos
Marca-Passo Artificial/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Falha de Equipamento , Seguimentos , Humanos , Pessoa de Meia-Idade
5.
Pacing Clin Electrophysiol ; 25(6): 936-9, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12137346

RESUMO

The aim of this study was to evaluate the dual chamber uni/bipolarpacemaker Minidual 50, manufactured by Sorin Biomedica. Between 1995 and 1998, 66 Minidual 50 models were implanted at the Heart Institute. During the follow-up period of 33 +/- 12.8 months (range 0-50 months), total function loss in seven (10.6%) units and false threshold measurement of sensing and pacing in three (4.5%) patients were observed. Average time from implantation to malfunction was 37 months (range 28-42). Malfunction was unrelated to battery status and could not be predicted by any measures obtained during the pacemaker follow-up period. Kaplan Meyer survival curve predicted a 70% 4-year malfunction-free survival of that pacemaker model. Given this high rate of total malfunction and the unpredictable nature of its occurrence, the authors recommend the replacement of all remaining Minidual 50 units at risk, at least in dependent patients.


Assuntos
Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...