Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Spine Surg ; 17(4): 534-541, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37253626

RESUMO

BACKGROUND: Three-dimensional (3D) navigation has become routinely used in spine surgery, allowing more accurate and safe procedures. However, radiation exposure related to the use of imaging is an unresolved issue, and information about it is relatively scarce. The "as low as reasonably achievable" (ALARA) principle aims to reduce the radiation exposure for the patients as low as possible. The objective of this study was to compare the effective dose related to the use of the O-arm in standard settings with adapted features for dose reduction during percutaneous cementoplasty. METHODS: From March 2021 to October 2022, all consecutive patients who underwent navigated percutaneous cementoplasty with the use of the O-arm were prospectively included. Demographic, operative, irradiation, and radiological data were collected. The main outcome was the effective dose (E) in millisievert (mSv). Secondary outcomes were the absolute risk of cancer (AR) in percent equivalent to a whole-body exposition, operative time, and radiological results according to Garnier. In group A, patients were operated on with standard settings of the O-arm, whereas in group B, navigation on the field of view, collimation, and low-dose settings were used. RESULTS: A total of 70 patients were included in the study: 43 in group A and 27 in group B. Also, 109 vertebrae were operated: 59 in group A and 50 in group B. Mean E was significantly higher in group A than in group B (9.94 and 4.34 mSv, respectively; P < 0.01). The 3D-related E followed the same trend (7.82 and 3.97 mSv, respectively), as did 2-dimensional-related E (2.12 and 0.37 mSv, respectively; P < 0.01). Average AR was also significantly higher in group A than in group B (5.10-4% and 2.10-4% respectively; P < 0.01). Operative time was similar in both groups, but the rate of satisfactory radiological results was higher in group A than in group B (95% and 84%, respectively; P = 0.11), and we found similar rates of cement leakage (22% and 24%, respectively; P = 0.71). CONCLUSIONS: The application of settings of the O-arm in accordance with the ALARA principle helped to significantly reduce the radiation exposure and should be routinely used for O-arm-assisted cementoplasty procedures. CLINICAL RELEVANCE: This study details technical aspects and settings that may help users of the O-arm to decrease radiation exposure to patients and surgeons alike, especially in cementoplasty procedures, as well as in other procedures performed under O-arm guidance.

2.
Int J Spine Surg ; 16(5): 944-952, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36113951

RESUMO

BACKGROUND: Vertebral compression fractures (VCF) are usually treated by cementoplasty. Computerized navigation allows more accurate surgery without additional imaging acquisition for guidance and related radiation exposure. New technologies trend to optimize the irradiation for patients and surgeons. The objective was to investigate the radiological results and radiation exposure of O-arm navigation compared with the all-in-one 2-dimensional/3-dimensional (2D/3D) Surgivisio device in navigated cementoplasty procedures. METHODS: Patients in the O-arm group comprised an O-arm prospective cohort as well as previous patients. Operations for VCF by navigated cementoplasty took place over 18 months. Patients in the Surgivisio group were the first patients operated on using Surgivisio and were prospectively recruited. Demographic, operative, and irradiation data were collected, as well as the image quality subjectively evaluated by the surgeon. The vertebal filling was evaluated using the Garnier classification and quoted as satisfactory, acceptable, or poor. The effective dose in millisievert (mSv) was calculated for radiation exposure estimation, and the absolute risk of cancer (AR) in percent equivalent to a whole-body irradiation was also calculated. RESULTS: A total of 123 patients were included: 62 in the O-arm group and 61 in the Surgivisio group. A total of 166 vertebrae were analyzed. Compared with the Surgivisio group, the effective dose was significantly higher in the O-arm group, with a mean of 11.47 vs 1.14 mSv, respectively (P < 0.001). The 2D part of the effective dose received by the surgeon was significantly higher in the O-arm group, with an average of 2.25 vs 0.47 mSv, respectively (P < 0.001). Overall AR followed the same trend, with a mean of 4.9 × 10-4% in the O-arm group and 5.7 × 10-5% in the Surgivisio group (P < 0.001). Operative time was significantly higher in the O-arm group (34.52 vs 30.12 minutes respectively, P = 0.03). Image quality was similarly sufficient in 3D, but in 2D, image quality was significantly better in the O-arm group (P = 0.01). Vertebral filling was significantly better in the O-arm group, with 100% of results reported as satisfactory and acceptable versus 85% in the Surgivisio group (P < 0.001). CONCLUSIONS: The O-arm delivered a 10-times higher effective dose during navigated cementoplasty in comparison with the Surgivisio device. The O-arm also had a longer operative time, but it had better image quality and radiological results.

3.
AME Case Rep ; 6: 24, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35928578

RESUMO

Background: Acetabular protrusion is an acetabular defect caused by the shift of the femoral head through the pelvic bone. Because of bone loss, usual anatomical landmarks may be confusing or absent, leading to a particularly high demanding surgical reconstruction in case of total hip arthroplasty (THA) implantation, without adequate support of the acetabulum due to major acetabular defect. To our knowledge, no article has dealt with acetabular defects to this extent and associated femoral osteolysis, which we will attempt to do in this case report. That's why we would like to share this case in order to propose an interesting alternative for the management of these challenging pathologies. Case Description: We hereby present the case of a rare pattern of severe acetabular prosthetic protrusion through the pelvic ring on a 77-year-old patient without any trauma. He was surgically treated with acetabular metal augment and a wide femoral modular reconstruction prosthesis. An instability was revealed after 6 weeks, so he underwent an early surgical revision with a constraint cup, overwhelming the absence of abductor apparatus. After this, his recovery was complete and uneventful, with effective function of the reconstructed hip joint and adequate stability of the prosthesis. Conclusions: Although acetabular protrusion is a rare complication in total hip replacement patients, we would like to draw attention to the challenging nature of this complication, both in terms of initial assessment and surgical management. The described strategy showed effective function of the reconstructed hip joint and final adequate stability of the prosthesis despite the absence of a competent abductor apparatus.

5.
J Spine Surg ; 7(2): 190-196, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34296031

RESUMO

BACKGROUND: Wrong-level surgery is a rare but unresolved issue in spine surgery. Some proposed protocols with high success rates, but it remains a risk with potential complications for the patient. Surgical navigation offers more accurate surgery, without additional irradiation related to the imaging device, in order to optimize the surgical guidance. METHODS: We describe our institutional technique with a needle placed under fluoroscopy at 3 cm from the incision line at the disc level to be operated, in order to guide the surgical approach; and we report a prospective evaluation of all patients during a six-month period operated by microdiscectomy for symptomatic lumbar discus hernia, whose hernia level was landmarked with this technique. We collected demographic, clinical-such as visual analog scale (VAS) of pain and Oswestry disability index (ODI) scores-operative and irradiation data for effective dose calculation. RESULTS: Thirty patients were included in the study. No wrong-level procedure was performed. Mean time for landmarking was 2.22 [1-5] minutes. Average operative time was 54.5 [30-150] minutes. The effective dose related to the imaging device use was 0.032 (0.007-0.092) mSv. The effective dose was also correlated to body mass index and disc level (P=0.05). The operative duration, complication rate and postoperative VAS and ODI scores were similar to the current literature. CONCLUSIONS: We advocate the use of percutaneous needle guidance, avoiding wrong-level microdiscectomy and helping the surgeon as a "navigation-like" device with minimal additional irradiation for the patient.

6.
BMJ Case Rep ; 14(4)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33837023

RESUMO

A 57-year-old immunocompetent male patient presented himself to our emergency department with lumbar pain for 10 days, after a lumbar torsion. He was neurologically intact, but showed signs of systemic inflammatory syndrome. A lumbar MRI found a spinal epidural abscess from L3-L4 to L5-S1 levels. The patient was operated early before occurrence of neurological deficit. The abscess cultures found a Streptococcus mitis infection. The patient made a good recovery after surgical decompression, washout with samples taken for cultures and targeted antibiotic therapy for 6 weeks.


Assuntos
Abscesso Epidural , Dor Lombar , Infecções Estreptocócicas , Abscesso Epidural/diagnóstico por imagem , Abscesso Epidural/tratamento farmacológico , Humanos , Vértebras Lombares , Masculino , Pessoa de Meia-Idade , Infecções Estreptocócicas/diagnóstico , Infecções Estreptocócicas/tratamento farmacológico , Streptococcus mitis
7.
J Neurosurg Case Lessons ; 2(23): CASE21500, 2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36061081

RESUMO

BACKGROUND: Cervical disc herniation is a common condition usually treated with anterior cervical discectomy and fusion (ACDF) or, more recently, with cervical disc arthroplasty (CDA). Both treatments offer similar clinical results. However, CDA has been found to offer fewer medium- to long-term complications as well as potential reduction of long-term adjacent disc degeneration. OBSERVATIONS: A 40-year-old man was treated with cervical discectomy and arthroplasty due to a C6-C7 disc herniation with left C7 radiculopathy. After the treatment, his postoperative follow-up appointments were uneventful for 9 months. However, after 9 months, he reported cervical pain and a right C7 radiculopathy after neck extension. Imaging confirmed a posterior intraprosthetic dislocation, the first case reported to date. The patient was received emergency surgery under neuromonitoring, and the prosthesis was replaced by an ACDF and anterior plate. The insert presented a rupture of the anterior horn. The patient presented no preoperative or postoperative neurological deficit, and his follow-up review revealed no issues. LESSONS: Posterior intraprosthetic dislocation is an extremely rare complication. It may occur with Mobi-C cervical arthroplasty in the case of rupture and oxidation of the polyethylene insert. Spine surgeons should be aware of this potential major complication.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...