Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Radiol Oncol ; 57(4): 507-515, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38038424

RESUMO

BACKGROUND: Using adaptive radiotherapy (ART), to determine objective clinical criteria that identify extremity soft tissue sarcoma (ESTS) patients requiring adaptation of their preoperative radiotherapy (RT) plan. PATIENTS AND METHODS: We included 17 patients with a lower extremity ESTS treated between 2019 and 2021 with preoperative RT, using helicoidal intensity-modulated RT (IMRT) tomotherapy, before surgical resection. We collected clinical, tumor parameters and treatment data. Repositioning was ascertained by daily Megavoltage computed tomography (MVCT) imaging. Using the PreciseART technology we retrospectively manually delineated at least one MVCT for each patient per week and recorded volume and dosimetric parameters. A greater than 5% change between target volume and planned target volume (PTV) dosimetric coverage from the initial planning CT scan to at least one MVCT was defined as clinically significant. RESULTS: All 17 patients experienced significant tumor volume changes during treatment; 7 tumors grew (41%) and 10 shrank (59%). Three patients (18%), all undifferentiated pleomorphic sarcomas (UPS) with increased volume changes, experienced significant reductions in tumor dose coverage. Seven patients required a plan adaptation, as determined by practical criteria applied in our departmental practice. Among these patients, only one ultimately experienced a significant change in PTV coverage. Three patients had a PTV decrease of coverage. Among them, 2 did not receive plan adaptation according our criteria. None of the patients with decreased tumor volumes had reduced target volume coverage. Monitoring volume variations by estimating gross tumor volume (GTV) on MVCT, in addition to axial and sagittal linear tumor dimensions, appeared to be most effective for detecting reductions in PTV coverage throughout treatment. CONCLUSIONS: Variations in ESTS volume are evident during preoperative RT, but significant dosimetric variations are rare. Specific attention should be paid to grade 2-3 UPSs during the first 2 weeks of treatment. In the absence of dedicated software in routine clinical practice, monitoring of tumor volume changes by estimating GTV may represent a useful strategy for identifying patients whose treatment needs to be replanned.


Assuntos
Sarcoma , Neoplasias de Tecidos Moles , Humanos , Dosagem Radioterapêutica , Carga Tumoral , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Sarcoma/diagnóstico por imagem , Sarcoma/radioterapia , Sarcoma/cirurgia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/radioterapia , Neoplasias de Tecidos Moles/cirurgia , Extremidades/diagnóstico por imagem , Extremidades/patologia
2.
Phys Med ; 109: 102568, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37015168

RESUMO

Anatomical variations occur during head and neck (H&N) radiotherapy (RT) treatment. These variations may result in underdosage to the target volume or overdosage to the organ at risk. Replanning during the treatment course can be triggered to overcome this issue. Due to technological, methodological and clinical evolutions, tools for adaptive RT (ART) are becoming increasingly sophisticated. The aim of this paper is to give an overview of the key steps of an H&N ART workflow and tools from the point of view of a group of French-speaking medical physicists and physicians (from GORTEC). Focuses are made on image registration, segmentation, estimation of the delivered dose of the day, workflow and quality assurance for an implementation of H&N offline and online ART. Practical recommendations are given to assist physicians and medical physicists in a clinical workflow.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia Guiada por Imagem , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Pescoço , Cabeça , Radioterapia Guiada por Imagem/métodos , Neoplasias de Cabeça e Pescoço/radioterapia
3.
Phys Med ; 80: 267-273, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33221708

RESUMO

PURPOSE: This study compared the positioning accuracy between cone-beam CT (CBCT) and ExacTrac (ETX) for a single-isocenter multiple target stereotactic radiosurgery (SRS) on two TrueBeam STx systems. METHODS: A single-isocenter treatment plan was simulated on an anthropomorphic head phantom with six spherical steel ball bearings (BBs). One of the BBs was chosen to be the isocenter. The five off-isocenter targets were located at various distances from the isocenter. MV portal images were generated to evaluate the deviations between the expected and the real center of the targets after CBCT and ETX positioning, respectively. RESULTS: The evaluation of the positioning accuracy for the isocenter target showed that CBCT and ETX positioning provided comparable, sub-millimetric results. Deviations in positioning accuracy were also calculated for all other targets, also showing comparable results for CBCT and ETX. Moreover, our study showed that the deviation between CBCT and ETX positioning were in better agreement for TBSTx1 and deviated slightly higher on TBSTx2 (maximum: 1.23 mm at S/I direction), due to a less perfect alignment between the CBCT coordinate system and the ETX coordinate system on TBSTx2 compared to TBSTx1. This study also showed a correlation between the target positioning accuracy and the distance to the isocenter. CONCLUSION: The positioning accuracy of ETX and CBCT for targets located at isocenter and off-isocenter locations was compared on two treatment machines and found comparable. Our study highlights the importance of a proper calibration procedure, to ensure correct alignment between the CBCT, ETX and machine coordinate systems.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiocirurgia , Tomografia Computadorizada de Feixe Cônico Espiral , Aceleradores de Partículas , Imagens de Fantasmas
4.
Clin Transl Radiat Oncol ; 16: 34-39, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30949592

RESUMO

During exclusive curative radiotherapy for head and neck tumors, the patient's organs at risk (OAR) and target volumes frequently change size and shape, leading to a risk of higher toxicity and lower control than expected on planned dosimetry. Adaptive radiotherapy is often necessary but 1) tools are needed to define the optimal time for replanning, and 2) the subsequent workflow is time-consuming. We designed a prospective study to evaluate 1) the validity of automatically deformed contours on the daily MVCT, in order to safely use the "dose-of the day" tool to check daily if replanning is necessary; 2) the automatically deformed contours on the replanning CT and the time gained in the replanning workflow. Forty-eight patients with T3-T4 and/or involved node >2 cm head and neck squamous cell carcinomas, planned for curative radiotherapy without surgery, will be enrolled. They will undergo treatment with helical IMRT including daily repositioning MVCTs. The contours proposed will be compared weekly on intermediate planning CTs (iCTs) on weeks 3, 4, 5 and 6. On these iCTs both manual recontouring and automated deformable registration of the initial contours will be compared with the contours automatically defined on the MVCT. The primary objective is to evaluate the Dice similarity coefficient (DSC) of the volumes of each parotid gland. The secondary objectives will evaluate, for target volumes and all OARs: the DSC, the mean distance to agreement, and the average surface-to-surface distance. Time between the automatic and the manual recontouring workflows will be compared.

5.
MAGMA ; 22(2): 89-100, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18998181

RESUMO

OBJECT: To this day, no parameter can really monitor the progression of multiple sclerosis (MS). In this study, an index the skewness (S) derived from parameters calculated in diffusion tensor imaging (DTI) has been tested on MS patients for its ability to monitor the disease course. MATERIALS AND METHODS: Eighteen patients underwent two examinations within 3 months consisting of a clinical evaluation (EDSS) and DTI acquisitions on a 1.5 T imager. Tensor was calculated thanks to"home-made" software. Mean diffusivity (MD) and fractional anisotropy (FA) histograms were described for normal-appearing white matter (NAWM) and gray matter (GM) of patients with S and also with usually indices peak position (pp) and peak height (ph) for the whole group of patients and for two separate groups according to their clinical status (EDSS < or = 3 and EDSS > 3 at month 0). RESULTS: Although no significant clinical evolution is observed over 3 months, S in GM showed a significant shift for both MD/FA histograms towards abnormal values for the whole group of patients (p = 0.02/p = 0.04) and for the group with EDSS

Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Esclerose Múltipla/patologia , Fibras Nervosas Mielinizadas/patologia , Técnica de Subtração , Adulto , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...