Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Respir Care ; 66(4): 619-625, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33293365

RESUMO

BACKGROUND: The ratio of dead space to tidal volume (VD/VT) is associated with mortality in patients with ARDS. Corrected minute ventilation ([Formula: see text]) is a simple surrogate of dead space, but, despite its increasing use, its association with mortality has not been proven. The aim of our study was to assess the association between [Formula: see text] and hospital mortality. We also compared the strength of this association with that of estimated VD/VT and ventilatory ratio. METHODS: We performed a retrospective study with prospectively collected data. We evaluated 187 consecutive mechanically ventilated subjects with ARDS caused by novel coronavirus disease (COVID-19). The association between [Formula: see text] and hospital mortality was assessed in multivariable logistic models. The same was done for estimated VD/VT and ventilatory ratio. RESULTS: Mean ± SD [Formula: see text] was 11.8 ± 3.3 L/min in survivors and 14.5 ± 3.9 L/min in nonsurvivors (P < .001) and was independently associated with mortality (adjusted odds ratio 1.15, P = .01). The strength of association of [Formula: see text] with mortality was similar to that of VD/VT and ventilatory ratio. CONCLUSIONS: [Formula: see text] was independently associated with hospital mortality in subjects with ARDS caused by COVID-19. [Formula: see text] could be used at the patient's bedside for outcome prediction and severity stratification, due to the simplicity of its calculation. These findings need to be confirmed in subjects with ARDS without viral pneumonia and when lung-protective mechanical ventilation is not rigorously applied.


Assuntos
COVID-19 , Coronavirus , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial , Síndrome do Desconforto Respiratório/etiologia , Estudos Retrospectivos , SARS-CoV-2 , Volume de Ventilação Pulmonar
2.
Ann Intensive Care ; 6(1): 53, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27306887

RESUMO

BACKGROUND: In some patients with auto-positive end-expiratory pressure (auto-PEEP), application of PEEP lower than auto-PEEP maintains a constant total PEEP, therefore reducing the inspiratory threshold load without detrimental cardiovascular or respiratory effects. We refer to these patients as "complete PEEP-absorbers." Conversely, adverse effects of PEEP application could occur in patients with auto-PEEP when the total PEEP rises as a consequence. From a pathophysiological perspective, all subjects with flow limitation are expected to be "complete PEEP-absorbers," whereas PEEP should increase total PEEP in all other patients. This study aimed to empirically assess the extent to which flow limitation alone explains a "complete PEEP-absorber" behavior (i.e., absence of further hyperinflation with PEEP), and to identify other factors associated with it. METHODS: One hundred patients with auto-PEEP of at least 5 cmH2O at zero end-expiratory pressure (ZEEP) during controlled mechanical ventilation were enrolled. Total PEEP (i.e., end-expiratory plateau pressure) was measured both at ZEEP and after applied PEEP equal to 80 % of auto-PEEP measured at ZEEP. All measurements were repeated three times, and the average value was used for analysis. RESULTS: Forty-seven percent of the patients suffered from chronic pulmonary disease and 52 % from acute pulmonary disease; 61 % showed flow limitation at ZEEP, assessed by manual compression of the abdomen. The mean total PEEP was 7 ± 2 cmH2O at ZEEP and 9 ± 2 cmH2O after the application of PEEP (p < 0.001). Thirty-three percent of the patients were "complete PEEP-absorbers." Multiple logistic regression was used to predict the behavior of "complete PEEP-absorber." The best model included a respiratory rate lower than 20 breaths/min and the presence of flow limitation. The predictive ability of the model was excellent, with an overoptimism-corrected area under the receiver operating characteristics curve of 0.89 (95 % CI 0.80-0.97). CONCLUSIONS: Expiratory flow limitation was associated with both high and complete "PEEP-absorber" behavior, but setting a relatively high respiratory rate on the ventilator can prevent from observing complete "PEEP-absorption." Therefore, the effect of PEEP application in patients with auto-PEEP can be accurately predicted at the bedside by measuring the respiratory rate and observing the flow-volume loop during manual compression of the abdomen.

3.
Respir Care ; 61(2): 134-41, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26604329

RESUMO

BACKGROUND: Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. METHODS: One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. RESULTS: The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio <1.85 (12.6; 4.7-39.6), respiratory system resistance >15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). CONCLUSIONS: Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values.


Assuntos
Obstrução das Vias Respiratórias/complicações , Respiração por Pressão Positiva Intrínseca/etiologia , Mecânica Respiratória/fisiologia , Fatores Etários , Idoso , Obstrução das Vias Respiratórias/fisiopatologia , Resistência das Vias Respiratórias/fisiologia , Índice de Massa Corporal , Estudos Transversais , Feminino , Fluxo Expiratório Forçado/fisiologia , Humanos , Capacidade Inspiratória/fisiologia , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Respiração por Pressão Positiva Intrínseca/fisiopatologia , Pressão , Respiração Artificial/métodos , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...