Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Br J Haematol ; 150(5): 601-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20553267

RESUMO

Despite the finding of elevated Tricuspid Regurgitant Velocity (TRV) in children below 5 years of age, the prevalence and evolution of Pulmonary Hypertension (PH) in young children with sickle cell disease (SCD) are unclear. In order to identify predictive factors of precocious PH development, SCD children > or =3 years old, at steady state, underwent annual echocardiography and Tissue Doppler Imaging (TDI). Patients receiving chronic transfusion were excluded. Thirty-seven of seventy-five patients were > or =3 years, with measurable TRV. In our young population (mean age 6.2 years) of mainly African, HbS/HbS patients, 8/37 (21.6%) had TRV > or =2.5 m/s, 8% being only 3 years old. Significant correlation was found between precocious TRV elevation and high platelet and reticulocyte counts and frequent acute chest syndromes (ACS). In multivariate analysis, ACS was the only variable predicting TRV > or =2.5 m/s. TDI of the 37 patients showed signs of diastolic dysfunction of the left ventricle. At follow-up all eight patients with high TRV displayed further increase and seven more developed TRV > or =2.5 m/s. PH seems to begin in children earlier than expected. Factors involved in its early onset might be different from the ones causing its development in older children or adults. African children might benefit from early screening and re-assessment once a year.


Assuntos
Anemia Falciforme/complicações , Hipertensão Pulmonar/etiologia , Adolescente , Anemia Falciforme/fisiopatologia , Velocidade do Fluxo Sanguíneo , Criança , Pré-Escolar , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Masculino , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/fisiopatologia
2.
Intensive Care Med ; 32(10): 1613-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16896862

RESUMO

OBJECTIVE: We compared neonatal helmet continuous positive airway pressure (CPAP) and the conventional nasal Infant Flow driver (IFD) CPAP in the noninvasive assessment of absolute cerebral blood flow (CBF) and relative cerebral blood volume changes (DeltaCBV) by near-infrared spectroscopy. DESIGN AND SETTING: A randomized crossover study in a tertiary referral NICU. PATIENTS AND INTERVENTIONS: Assessment of CBF and DeltaCBV in 17 very low birth weight infants with respiratory distress (median age 5 days) treated with two CPAP devices at a continuous distending pressure of 4 mbar. MEASUREMENTS AND RESULTS: Neonates were studied for two consecutive 60-min periods with helmet CPAP and with IFD CPAP. Basal chromophore traces enabled DeltaCBV changes to be calculated. CBF was calculated in milliliters per 100 grams per minute from the saturation rise integral and rate of rise O(2)Hb-HHb. Median (range) CBF with helmet CPAP was 27.37 (9.47-48.20) vs. IFD CBF 34.74 (13.59-60.10)(p=0.049) and DeltaCBV 0.15 (0.09-0.28) with IFD and 0.13 (0.07-0.27) with helmet CPAP (NS). Using helmet and IFD CPAP, the neonates showed no difference in mean physiological parameters (transcutaneous carbon dioxide and oxygen tension, pulse oximetry saturation, heart rate, breathing rate, mean arterial blood pressure, desaturation rate, axillary temperature). CONCLUSION: Assessing CBF and DeltaCBV measured by near-infrared spectroscopy with two CPAP devices revealed no differences in relative blood volume, but CBF was lower with helmet CPAP. Greater active vasoconstriction and/or passive capillary and/or venous vessel compression seem the most likely reason, due to a positive pressure around the head, neck, and shoulders by comparison with the airway pressure.


Assuntos
Circulação Cerebrovascular , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Análise de Variância , Tempo de Circulação Sanguínea , Volume Sanguíneo , Pressão Positiva Contínua nas Vias Aéreas/métodos , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Unidades de Terapia Intensiva Neonatal , Masculino , Máscaras , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Estatísticas não Paramétricas , Resultado do Tratamento
3.
Intensive Care Med ; 31(6): 859-64, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15838676

RESUMO

OBJECTIVE: We compared the effectiveness of a new continuous positive airway pressure (CPAP) device (neonatal helmet CPAP) with a conventional nasal CPAP system in preterm neonates needing continuous distending pressure. DESIGN AND SETTING: Randomized, physiological, cross-over study in a tertiary referral, neonatal intensive care unit in a university teaching hospital. PATIENTS: Twenty very low birth weight infants with a postnatal age greater than 24 h who were receiving nasal CPAP for apnea and/or mild respiratory distress were enrolled. INTERVENTIONS: CPAP delivered by neonatal helmet CPAP and nasal CPAP in random order for two subsequent 90-min periods. MEASUREMENTS AND RESULTS: Were continuously measured the Neonatal Infant Pain Scale (NIPS) score, oxygen requirements, respiratory rate, heart rate, oxygen saturation, transcutaneous PO(2) (tcPO(2)) and PCO(2) (tcPCO(2)), blood pressure, and desaturations. NIPS scores were significantly lower when the infants were on the neonatal helmet CPAP than when they were on nasal CPAP (0.26+/-0.07 vs. 0.63+/-0.12). The other studied parameters did not differ between the two CPAP modes. The number of desaturations was reduced during the neonatal helmet CPAP treatment (18 vs. 32), although this difference was not significant. CONCLUSIONS: In this short-term physiological study the neonatal helmet CPAP appears to be as good as the golden standard for managing preterm infants needing continuous distending pressure, with enhanced tolerability. Further evaluation in a randomized clinical trial is needed to confirm these findings.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Recém-Nascido Prematuro , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Estudos Cross-Over , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Dor/etiologia , Dor/prevenção & controle , Estatísticas não Paramétricas
4.
Biol Neonate ; 87(4): 217-20, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15650304

RESUMO

BACKGROUND: The laryngeal mask airway (LMA(TM), Laryngeal Mask Co. Ltd, Jersey, UK) is a supraglottic device used to administer positive pressure ventilation (PPV) in adults, pediatric and neonatal patients. OBJECTIVES: To avoid endotracheal intubation, we evaluated the feasibility and practicality of administering surfactant via the LMA(TM) in preterm infants with respiratory distress syndrome (RDS). METHODS: Infants less than 72 h old with a gestational age of < or =35 weeks and a birth weight of >800 g, treated with nasal continuous positive airway pressure (CPAP, 5 cm H2O) for RDS were eligible for inclusion in the study if the arterial-to-alveolar oxygen tension ratio (a/APO2) was <0.20 over a period of >60 min. RESULTS: Eight preterm infants, median gestational age 31 (range 28-35) weeks; birth weight 1,700 (880-2,520) g, treated with nasal CPAP for RDS were enrolled. Three hours after surfactant instillation, the mean a/APO2 was significantly increased (0.13 +/- 0.04 to 0.34 +/- 0.11; p < 0.01) without complications. CONCLUSIONS: The LMA may be a useful and noninvasive conduit for the administration of surfactant therapy. A large randomized comparative clinical trial will be required to confirm the efficacy of this technique.


Assuntos
Produtos Biológicos/administração & dosagem , Recém-Nascido Prematuro/fisiologia , Máscaras Laríngeas , Fosfolipídeos/administração & dosagem , Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Gasometria , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro/sangue , Masculino , Síndrome do Desconforto Respiratório do Recém-Nascido/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...