Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Cardiovasc Revasc Med ; 31: 26-31, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33309231

RESUMO

BACKGROUND: The risk of nosocomial COVID-19 infection for vulnerable aortic stenosis patients and intensive care resource utilization has led to cardiac surgery deferral. Untreated severe symptomatic aortic stenosis has a dismal prognosis. TAVR offers an attractive alternative to surgery as it is not reliant on intensive care resources. We set out to explore the safety and operational efficiency of restructuring a TAVR service and redeploying it to a new non-surgical site during the COVID-19 pandemic. METHODS: The institutional prospective service database was retrospectively interrogated for the first 50 consecutive elective TAVR cases prior to and after our institution's operational adaptations for the COVID-19 pandemic. Our endpoints were VARC-2 defined procedural complications, 30-day mortality or re-admission and service efficiency metrics. RESULTS: The profile of patients undergoing TAVR during the pandemic was similar to patients undergoing TAVR prior to the pandemic with the exception of a lower mean age (79 vs 82 years, p < 0.01) and median EuroScore II (3.1% vs 4.6%, p = 0.01). The service restructuring and redeployment contributed to the pandemic-mandated operational efficiency with a reduction in the distribution of pre-admission hospital visits (3 vs 3 visits, p < 0.001) and the time taken from TAVR clinic to procedure (26 vs 77 days, p < 0.0001) when compared to the pre-COVID-19 service. No statistically significant difference was noted in peri-procedural complications and 30-day outcomes, while post-operative length of stay was significantly reduced (2 vs 3 days, p < 0.0001) when compared to pre-COVID-19 practice. CONCLUSIONS: TAVR service restructuring and redeployment to align with pandemic-mandated healthcare resource rationalization is safe and feasible.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Pandemias , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2 , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 96(2): 432-439, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31742885

RESUMO

OBJECTIVES: To identify clinical and procedural practice predictors of avoidable complications during transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR is evolving as a viable strategy for treatment of aortic stenosis (AS). Vascular complications, major bleeding, or pericardial tamponade may be influenced by procedural practice. METHODS: The Oxford TAVR (OxTAVI) prospective registry was retrospectively analyzed to identify predictors of avoidable procedural complications in a contemporary cohort of transfemoral TAVR between January 2015 and September 2018. The primary endpoint was defined as a hierarchic composite of in-hospital mortality, pericardial effusion/cardiac tamponade, major bleeding, and vascular access complications. Individual components of the primary endpoint have been analyzed separately. RESULTS: Five-hundred-twenty-nine patients underwent transfemoral TAVR using contemporary techniques during the study period and were enrolled in the OxTAVI registry. Female sex and high frailty were associated with a higher risk of death, major bleeding, vascular complication or pericardial tamponade. The use of ultrasound (US) guidance for vascular access management was independently associated with a reduced composite primary endpoint (OR = 0.35, CI:0.14-0.86, p = .02) after adjustment for clinical confounders, largely driven by a threefold reduction in vascular access complication (OR = 0.29, CI:0.15-0.55, p < .001). Performing rapid pacing via the left ventricle guidewire (LV-GW) was associated with a significant decrease in the risk of cardiac tamponade/pericardial effusion (OR = 0.19, CI:0.05-0.66, p = .009). CONCLUSION: US-guided vascular access management and rapid pacing via the LV-GW are important determinants of reduced procedural complications during TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter , Ultrassonografia de Intervenção , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Feminino , Idoso Fragilizado , Fragilidade/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/mortalidade
3.
BMJ ; 335(7623): 759, 2007 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-17884862

RESUMO

OBJECTIVE: To verify or refute the value of hospital episode statistics (HES) in determining 30 day mortality after open congenital cardiac surgery in infants nationally in comparison with central cardiac audit database (CCAD) information. DESIGN: External review of paediatric cardiac surgical outcomes in England (HES) and all UK units (CCAD), as derived from each database. SETTING: Congenital heart surgery centres in the United Kingdom. DATA SOURCES: HES for congenital heart surgery and corresponding information from CCAD for the period 1 April 2000 to 31 March 2002. HES was restricted to the 11 English centres; CCAD covered all 13 UK centres. MAIN OUTCOME MEASURE: Mortality within 30 days of open heart surgery in infants aged under 12 months. RESULTS: In a direct comparison for the years when data from the 11 English centres were available from both databases, HES omitted between 5% and 38% of infants operated on in each centre. A median 40% (range 0-73%) shortfall occurred in identification of deaths by HES. As a result, mean 30 day mortality was underestimated at 4% by HES as compared with 8% for CCAD. In CCAD, between 1% and 23% of outcomes were missing in nine of 11 English centres used in the comparison (predominantly those for overseas patients). Accordingly, CCAD mortality could also be underestimated. Oxford provided the most complete dataset to HES, including all deaths recorded by CCAD. From three years of CCAD, Oxford's infant mortality from open cardiac surgery (10%) was not statistically different from the mean for all 13 UK centres (8%), in marked contrast to the conclusions drawn from HES for two of those years. CONCLUSIONS: Hospital episode statistics are unsatisfactory for the assessment of activity and outcomes in congenital heart surgery. The central cardiac audit database is more accurate and complete, but further work is needed to achieve fully comprehensive risk stratified mortality data. Given unresolved limitations in data quality, commercial organisations should reconsider placing centre specific or surgeon specific mortality data in the public domain.


Assuntos
Cardiopatias Congênitas/cirurgia , Hospitalização/estatística & dados numéricos , Ponte de Artéria Coronária/mortalidade , Unidades de Cuidados Coronarianos/estatística & dados numéricos , Cardiopatias Congênitas/mortalidade , Mortalidade Hospitalar , Humanos , Lactente , Recém-Nascido , Auditoria Médica , Prontuários Médicos/normas , Resultado do Tratamento , Reino Unido/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...