Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 43(6): 593-601, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32333406

RESUMO

BACKGROUND: Pericardial access is complicated by two difficulties: confirming when the needle tip is in the pericardial space, and avoiding complications during access, such as inadvertently puncturing other organs. Conventional imaging tools are inadequate for addressing these difficulties, as they lack soft-tissue markers that could be used as guidance during access. A system that can both confirm access and avoid inadvertent organ injury is needed. METHODS: A 21G micropuncture needle was modified to include two small electrodes at the needle tip. With continuous bioimpedance monitoring from the electrodes, the needle was used to access the pericardium in porcine models (n  =  4). The needle was also visualized in vivo by using an electroanatomical map (n  =  2). Bioimpedance data from different tissues were analyzed retrospectively. RESULTS: Bioimpedance data collected from the subcutaneous space (992.8 ± 13.1 Ω), anterior mediastinum (972.2 ± 14.2 Ω), pericardial space (323.2 ± 17.1 Ω), mid-myocardium (349.7 ± 87.6 Ω), right ventricular cavity (235.0 ± 9.7 Ω), lung (1142.0 ± 172.0 Ω), liver (575.0 ± 52.6 Ω), and blood (177.5 ± 1.9 Ω) differed significantly by tissue type (P < .01). Phase data in the frequency domain correlated well with the needle being in the pericardial space. A simple threshold analysis effectively separated lung (threshold  =  1120.0 Ω) and blood (threshold  =  305.9 Ω) tissues from the other tissue types. CONCLUSIONS: Continuous bioimpedance monitoring from a modified micropuncture needle during pericardial access can be used to clearly differentiate tissues. Combined with traditional imaging modalities, this system allows for confirming access to the pericardial space while avoiding inadvertent puncture of other organs, creating a safer and more efficient needle-access procedure.


Assuntos
Pericárdio/cirurgia , Punções/instrumentação , Punções/métodos , Animais , Impedância Elétrica , Desenho de Equipamento , Agulhas , Suínos
2.
J Cardiovasc Electrophysiol ; 31(6): 1430-1435, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32270564

RESUMO

BACKGROUND: Atrioventricular nodal reentrant tachycardia (AVNRT) is treatable by catheter ablation. Advances in mapping-system technology permit fluoroless workflow during ablations. As national practice trends toward fluoroless approaches, easily obtained, reproducible methods of slow-pathway identification, and ablation become increasingly important. We present a novel method of slow-pathway identification and initial ablation results from this method. METHODS AND RESULTS: We examined AVNRT ablations performed at our institution over a 12-month period. In these cases, the site of the slow pathway was predicted by latest activation in the inferior triangle of Koch during sinus rhythm. Ablation was performed in this region. Proximity of the predicted site to the successful ablation location, complication rates, and patient outcomes were recorded. Junctional rhythm was seen in 40/41 ablations (98%) at the predicted site (mean, 1.3 lesions and median, 1 lesion per case). One lesion was defined as 5 mm of ablation. The initial ablation was successful in 39/41 cases (95%); in two cases, greater or equal to 2 echo beats were detected after the initial ablation, necessitating further lesion expansion. In 8/41 cases (20%), greater than one lesion was placed during initial ablation before attempted reinduction. Complications included one transient heart block and one transient PR prolongation. During follow-up (median, day 51), one patient had lower-extremity deep-vein thrombosis and pulmonary embolus, and one had a lower-extremity superficial venous thrombosis. There was one tachycardia recurrence, which prompted a redo ablation. CONCLUSIONS: Mapping-system detection of late-activation, low-amplitude voltage during sinus rhythm provides an objective, and fluoroless means of identifying the slow pathway in typical AVNRT.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Recidiva , Reoperação , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
3.
JACC Clin Electrophysiol ; 4(2): 257-264, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29749947

RESUMO

OBJECTIVES: The aim of this study was to evaluate the incidence, predictors, and associated mortality of pre-implantation, early, and late ventricular arrhythmias (VAs) in patients receiving continuous-flow left ventricular assist devices (CFLVADs). BACKGROUND: VAs are common both pre- and post-implantation of left ventricular assist devices. Limited data exist on their prognostic impact in contemporary CFLVADs. METHODS: A retrospective review was performed to identify patients who underwent CFLVAD implantation between 2000 and 2015 with 2 years of follow-up. All VAs, defined as ventricular fibrillation, ventricular tachycardia lasting >30 s, or a ventricular rhythm requiring defibrillation, were analyzed. VAs occurring within 30 days of implantation were defined as early. Recorded outcomes included death and receipt of cardiac transplant. RESULTS: A total of 517 patients were included for analysis. Early VAs were associated with a significant reduction in survival (hazard ratio: 1.83; 95% confidence interval: 1.28 to 2.61; p = 0.001) compared with patients with late or no VAs. Pre-implantation variables independently predictive of early VAs included prior cardiac surgery (odds ratio: 1.90; 95% confidence interval: 1.09 to 3.32; p = 0.023) and pre-CFLVAD ventricular tachycardia storm (odds ratio: 3.15; 95% confidence interval: 1.49 to 6.69; p = 0.003). The incidence of early VAs from 2000 to 2007 was as high as 47%, whereas the highest incidence from 2008 to 2015 was <22%. CONCLUSIONS: VAs within 30 days after CFLVAD implantation are associated with an increased risk for death. Predictors of early VAs include prior cardiac surgery and pre-CFLVAD ventricular tachycardia storm. Temporal trends have shown a decrease in VA from 2000 to 2015. Strategies to reduce arrhythmia burden shortly after CFLVAD implantation warrant further investigation.


Assuntos
Arritmias Cardíacas , Coração Auxiliar , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/mortalidade , Feminino , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Coração Auxiliar/estatística & dados numéricos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
4.
J Cardiovasc Electrophysiol ; 28(12): 1492-1499, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28833720

RESUMO

INTRODUCTION: Epicardial catheter ablation is increasingly used to treat arrhythmias with an epicardial component. Nevertheless, percutaneous epicardial access remains associated with a significant risk of major complications. Developing a technology capable of confirming proper placement within the pericardial space could decrease complication rates. The purpose of this study was to examine differences in bioimpedance among the pericardial space, anterior mediastinum, and right ventricle. METHODS: An ovine model (n = 3) was used in this proof-of-concept study. A decapolar catheter was used to collect bipolar impedance readings; data were collected between each of five electrode pairs of varying distances. Data were collected from three test regions: the pericardial space, anterior mediastinum, and right ventricle. A control region in the inferior vena cava was used to normalize the data from the test regions. Analysis of variance was used to test for differences among regions. RESULTS: A total of 10 impedance values were collected in each animal between each of the five electrode pairs in the three test regions (n = 340) and the control region (n = 145). The average normalized impedance values were significantly different among the pericardial space (1.760 ± 0.370), anterior mediastinum (3.209 ± 0.227), and right ventricle (1.024 ± 0.207; P < 0.0001). In post hoc testing, the differences between each pair of regions were significant, as well (P < 0.001 for all). CONCLUSION: Impedance values are significantly different among these three anatomical compartments. Therefore, impedance can be potentially used as a means to guide percutaneous epicardial access.


Assuntos
Impedância Elétrica , Mapeamento Epicárdico/métodos , Mediastino/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Animais , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Masculino , Mediastino/fisiopatologia , Pericárdio/fisiopatologia , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...