Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Neurosci ; 11: 445, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28878616

RESUMO

Purpose: We assessed the safety and efficacy of a technically advanced subretinal electronic implant, RETINA IMPLANT Alpha AMS, in end stage retinal degeneration in an interim analysis of two ongoing prospective clinical trials. The purpose of this article is to describe the interim functional results (efficacy). Methods: The subretinal visual prosthesis RETINA IMPLANT Alpha AMS (Retina Implant AG, Reutlingen, Germany) was implanted in 15 blind patients with hereditary retinal degenerations at four study sites with a follow-up period of 12 months (www.clinicaltrials.gov NCT01024803 and NCT02720640). Functional outcome measures included (1) screen-based standardized 2- or 4-alternative forced-choice (AFC) tests of light perception, light localization, grating detection (basic grating acuity (BaGA) test), and Landolt C-rings; (2) gray level discrimination; (3) performance during activities of daily living (ADL-table tasks). Results: Implant-mediated light perception was observed in 13/15 patients. During the observation period implant mediated localization of visual targets was possible in 13/15 patients. Correct grating detection was achieved for spatial frequencies of 0.1 cpd (cycles per degree) in 4/15; 0.33 cpd in 3/15; 0.66 cpd in 2/15; 1.0 cpd in 2/15 and 3.3 cpd in 1/15 patients. In two patients visual acuity (VA) assessed with Landolt C- rings was 20/546 and 20/1111. Of 6 possible gray levels on average 4.6 ± 0.8 (mean ± SD, n = 10) were discerned. Improvements (power ON vs. OFF) of ADL table tasks were measured in 13/15 patients. Overall, results were stable during the observation period. Serious adverse events (SAEs) were reported in 4 patients: 2 movements of the implant, readjusted in a second surgery; 4 conjunctival erosion/dehiscence, successfully treated; 1 pain event around the coil, successfully treated; 1 partial reduction of silicone oil tamponade leading to distorted vision (silicon oil successfully refilled). The majority of adverse events (AEs) were transient and mostly of mild to moderate intensity. Conclusions: Psychophysical and subjective data show that RETINA IMPLANT Alpha AMS is reliable, well tolerated and can restore limited visual functions in blind patients with degenerations of the outer retina. Compared with the previous implant Alpha IMS, longevity of the new implant Alpha AMS has been considerably improved. Alpha AMS has meanwhile been certified as a commercially available medical device, reimbursed in Germany by the public health system.

2.
Biomed Microdevices ; 19(1): 7, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28124761

RESUMO

Despite recent developments and new treatments in ophthalmology there is nothing available to cure retinal degenerations like Retinitis Pigmentosa (RP) yet. One of the most advanced approaches to treat people that have gone blind due to RP is to replace the function of the degenerated photoreceptors by a microelectronic neuroprosthetic device. Basically, this subretinal active implant transforms the incoming light into electric pulses to stimulate the remaining cells of the retina. The functional time of such devices is a crucial aspect. In this paper the laboratory and clinical reliability of the two active subretinal implants Alpha IMS and Alpha AMS is presented. Based on clinical data the median operating life of the Alpha AMS is estimated to be 3.3 years with a one-sided lower 75 % confidence level of 2.0 years. This data shows a significant improvement of the device lifetime compared to the previous device Alpha IMS which shows a median lifetime of 0.6 years with a lower confidence bound (75 %) of 0.5 years. The results are in good agreement with laboratory data from accelerated aging tests of the implant components, showing an estimated median lifetime for Alpha IMS components of 0.7 years compared to the improved lifetime of Alpha AMS of 4.7 years.


Assuntos
Laboratórios , Retina , Próteses Visuais , Ensaios Clínicos como Assunto , Humanos , Estimativa de Kaplan-Meier , Desenho de Prótese , Reprodutibilidade dos Testes
3.
J Ophthalmol ; 2015: 842518, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26783453

RESUMO

In hereditary retinal diseases photoreceptors progressively degenerate, often causing blindness without therapy being available. Newly developed subretinal implants can substitute functions of photoreceptors. Retina implant extraocular surgical technique relies strongly on cochlear-implant know-how. However, a completely new surgical approach providing safe handling of the photosensor array had to be developed. The Retina Implant Alpha IMS consisting of a subretinal microphotodiode array and cable linked to a cochlear-implant-like ceramic housing was introduced via a retroauricular incision through a subperiosteal tunnel above the zygoma into the orbit using a specially designed trocar. Implant housing was fixed in a bony bed within a tight subperiosteal pocket in all patients. Primary outcomes were patient short term safety as well as effectiveness. Nine patients participated in the first part of the multicenter trial and received the subretinal visual implant in one eye. In all cases microphotodiode array pull-through procedure and stable positioning were possible without affecting the device function. No intraoperative complications were encountered. The minimally invasive suprazygomatic tunneling technique for the sensor unit as well as a subperiosteal pocket fixation of the implant housing provides a safe extraocular implantation approach of a subretinal device with a transcutaneous extracorporeal power supply.

4.
Proc Biol Sci ; 280(1757): 20130077, 2013 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-23427175

RESUMO

This study aims at substituting the essential functions of photoreceptors in patients who are blind owing to untreatable forms of hereditary retinal degenerations. A microelectronic neuroprosthetic device, powered via transdermal inductive transmission, carrying 1500 independent microphotodiode-amplifier-electrode elements on a 9 mm(2) chip, was subretinally implanted in nine blind patients. Light perception (8/9), light localization (7/9), motion detection (5/9, angular speed up to 35 deg s(-1)), grating acuity measurement (6/9, up to 3.3 cycles per degree) and visual acuity measurement with Landolt C-rings (2/9) up to Snellen visual acuity of 20/546 (corresponding to decimal 0.037° or corresponding to 1.43 logMAR (minimum angle of resolution)) were restored via the subretinal implant. Additionally, the identification, localization and discrimination of objects improved significantly (n = 8; p < 0.05 for each subtest) in repeated tests over a nine-month period. Three subjects were able to read letters spontaneously and one subject was able to read letters after training in an alternative-force choice test. Five subjects reported implant-mediated visual perceptions in daily life within a field of 15° of visual angle. Control tests were performed each time with the implant's power source switched off. These data show that subretinal implants can restore visual functions that are useful for daily life.


Assuntos
Cegueira/cirurgia , Implantes Experimentais , Próteses Neurais , Percepção Visual , Próteses Visuais , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Células Fotorreceptoras de Vertebrados/fisiologia , Desenho de Prótese , Acuidade Visual
5.
Clin Exp Optom ; 96(1): 4-13, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23173814

RESUMO

BACKGROUND: Replacing the function of visual pathway neurons by electronic implants is a novel approach presently explored by various groups in basic research and clinical trials. The novelty raises unexplored methodological aspects of clinical trial design that may require adaptation and validation. METHODS: We present procedures of efficacy and safety testing for subretinal visual implants in humans, as developed during our pilot trial 2005 to 2009 and multi-centre clinical trial since 2010. RESULTS: Planning such a trial requires appropriate inclusion and exclusion criteria. For subretinal electronic visual implants, patients with photoreceptor degeneration are the target patient group, whereas presence of additional diseases affecting clear optic media or the visual pathway must be excluded. Because sham surgery is not possible, a masked study design with implant power ON versus OFF is necessary. Prior to the efficacy testing by psychophysical tests, the implant's technical characteristics have to be controlled via electroretinography (ERG). Moreover the testing methods require adaptation to the particular technology. We recommend standardised tasks first to determine the light perception thresholds, light localisation and movement detection, followed by grating acuity and vision acuity test via Landolt C rings. A laboratory setup for assessing essential activities of daily living is presented. Subjective visual experiences with the implant in a natural environment, as well as questionnaires and psychological counselling are further important aspects. CONCLUSIONS: A clinical trial protocol for artificial vision in humans, which leads a patient from blindness to the state of very low vision is a challenge and cannot be defined completely prior to the study. Available tests of visual function may not be sufficiently suited for efficacy testing of artificial vision devices. A protocol based on experience with subretinal visual implants in 22 patients is presented that has been found adequate to monitor safety and efficacy.


Assuntos
Cegueira/reabilitação , Retina/fisiopatologia , Acuidade Visual , Próteses Visuais , Atividades Cotidianas , Cegueira/fisiopatologia , Humanos , Desenho de Prótese , Inquéritos e Questionários
6.
Invest Ophthalmol Vis Sci ; 53(7): 3748-55, 2012 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-22562517

RESUMO

PURPOSE: To optimize methods for positioning subretinal visual implants, customizing their cable length, guiding them to the predetermined retinal position, and evaluating their performance. METHODS: Ten eyes of 10 patients (6 male, 4 female, mean age 46.4 years) were investigated before implantation of a subretinal visual implant. The structural characteristics of the retina as well as the ocular dimensions were determined. Topographic images of the prospective implantation site were subdivided into grids of squares. Each square received a weighted score for suitability. The sum of the scores was calculated, and the region with the highest score was chosen for the implant. In each case, the implant's power supply cable length was calculated by means of magnetic resonance imaging. The planned and achieved positions before and after implantation were compared. RESULTS: The mean light sensitivity ratio between the area actually covered by the chip and that of the planned position was 90.8% with an SD of 11.4%. In two cases with almost perfect positioning, the computed ratio was 100%. Measurements showed that to achieve a 95% sensitivity rate the difference between the planned and achieved chip position must be less than 1.7 mm. Preoperative calculations of the intraocular cable length proved accurate in all cases. CONCLUSIONS: Preoperative evaluation of retinal structures and eye morphology is useful for guiding a retinal implant to the designated area. It is a meaningful tool for planning and performing retinal chip implantation, and it optimizes personalized implantation. (ClinicalTrials.gov numbers, NCT00515814, NCT01024803.).


Assuntos
Cegueira/cirurgia , Cuidados Pré-Operatórios/métodos , Implantação de Prótese/métodos , Retina/cirurgia , Retinose Pigmentar/cirurgia , Adulto , Eletrodos Implantados , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Retina/patologia , Resultado do Tratamento
7.
Invest Ophthalmol Vis Sci ; 52(8): 5995-6003, 2011 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-21693599

RESUMO

PURPOSE: The perception of 11 persons blinded by hereditary retinal degeneration elicited by a subretinally implanted 16-electrode array used for light-independent direct stimulation of the retina is described. This device is part of the Tübingen retina implant, which also employs a light-sensitive, multiphotodiode array (MPDA). The ability to reliably recognize complex spatial percepts was investigated. METHODS: Eleven blind volunteers received implants and participated in standardized psychophysical tests investigating the size and shape of perceptions elicited by single-electrode activation, multiple-electrode activation, and activation of compound patterns such as simplified letters. RESULTS: Visual percepts were elicited reliably in 8 of 11 patients. On single-electrode activation, percepts were generally described as round spots of light of distinguishable localization in the visual field. On activation of a pattern of electrodes, percepts matched that pattern when electrodes were activated sequentially. Patterns such as horizontal or vertical bars were identified reliably; the most recent participant was able to recognize simplified letters presented on the 16-electrode array. The smallest distance between sites of concurrent retinal stimulation still yielding discernible spots of light was assessed to be 280 µm, corresponding to a logMAR of 1.78. CONCLUSIONS: Subretinal electric stimulation can yield reliable, predictable percepts. Patterned perception is feasible, enabling blind persons to recognize shapes and discriminate different letters. Stimulation paradigms must be optimized, to further increase spatial resolution, demanding a better understanding of physical and biological effects of single versus repetitive stimulation (ClinicalTrials.gov number, NCT00515814).


Assuntos
Cegueira/cirurgia , Reconhecimento Visual de Modelos , Distrofias Retinianas/cirurgia , Percepção Espacial , Próteses Visuais , Adulto , Cegueira/reabilitação , Eletrodos Implantados , Humanos , Masculino , Pessoa de Meia-Idade , Percepção de Movimento , Orientação , Desenho de Prótese , Implantação de Prótese/métodos , Psicofísica , Distrofias Retinianas/reabilitação
8.
Proc Biol Sci ; 278(1711): 1489-97, 2011 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-21047851

RESUMO

A light-sensitive, externally powered microchip was surgically implanted subretinally near the macular region of volunteers blind from hereditary retinal dystrophy. The implant contains an array of 1500 active microphotodiodes ('chip'), each with its own amplifier and local stimulation electrode. At the implant's tip, another array of 16 wire-connected electrodes allows light-independent direct stimulation and testing of the neuron-electrode interface. Visual scenes are projected naturally through the eye's lens onto the chip under the transparent retina. The chip generates a corresponding pattern of 38 × 40 pixels, each releasing light-intensity-dependent electric stimulation pulses. Subsequently, three previously blind persons could locate bright objects on a dark table, two of whom could discern grating patterns. One of these patients was able to correctly describe and name objects like a fork or knife on a table, geometric patterns, different kinds of fruit and discern shades of grey with only 15 per cent contrast. Without a training period, the regained visual functions enabled him to localize and approach persons in a room freely and to read large letters as complete words after several years of blindness. These results demonstrate for the first time that subretinal micro-electrode arrays with 1500 photodiodes can create detailed meaningful visual perception in previously blind individuals.


Assuntos
Eletrodos Implantados , Implantes Experimentais , Leitura , Retina/cirurgia , Distrofias Retinianas/cirurgia , Auxiliares Sensoriais , Percepção Visual/fisiologia , Adulto , Feminino , Humanos , Luz , Masculino
9.
Artigo em Inglês | MEDLINE | ID: mdl-21096939

RESUMO

Our group has developed a subretinal microphotodiode array for restoration of vision. In a clinical pilot study the array has been implanted in 11 patients suffering from photoreceptor degenerations. Here we present promising results from some of those patients where the retinal tissue above the chip was functional and the implant fulfilled its expected function. A spatial resolution of approximately 0.3 cycles/degree could be achieved with fine stripe patterns. In one subject where the implant had been placed directly under the macular region of the retina a visual acuity of 20/1000 could be measured. Artificially restored visual acuity of this quality has not been reported previously. Finally, we present images illustrating an approximation of how the visual perceptions might have appeared to the subjects, based on a mathematical model and patient reports.


Assuntos
Eletrodos Implantados , Reconhecimento Visual de Modelos/fisiologia , Recuperação de Função Fisiológica/fisiologia , Retina/fisiopatologia , Visão Ocular/fisiologia , Humanos , Microeletrodos , Oftalmoscópios , Estimulação Luminosa , Implantação de Prótese
10.
Br J Ophthalmol ; 94(7): 843-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20606022

RESUMO

Two patients carrying an active subretinal implant with extra-ocular parts were examined by high-resolution CT. Cranial scans were acquired in the primary position and in eight additional directions of gaze with eyes open and closed to demonstrate the mobility of the eyeball and the implant within the orbital cavity. Three-dimensional images were constructed to visualise the path of the implant from the retro-auricular space around the lateral orbital rim through the orbit and within the subretinal space up to the device's final para-foveal position. Images were obtainable in high quality, resulting in three-dimensional models illustrating all parts of the implant including the micro-photodiode array at the tip in the subretinal space. The implant followed eye movements in all directions of gaze; eye movements were only minimally restricted as described in previous publications. Since all, except intra-ocular, parts of the implant evade direct examination, CT can be useful to assess the technical integrity and the biocompatibility and biostability of retinal implants.


Assuntos
Próteses e Implantes , Retina/cirurgia , Retinose Pigmentar/cirurgia , Adulto , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Olho/diagnóstico por imagem , Movimentos Oculares , Estudos de Viabilidade , Humanos , Imageamento Tridimensional/métodos , Masculino , Ilustração Médica , Órbita/diagnóstico por imagem , Cuidados Pós-Operatórios/métodos , Desenho de Prótese , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...