Resultados 1 - 20 de 30
Filtrar
1.
Radiol Cardiothorac Imaging ; 6(4): e230328, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39023373

RESUMO

Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Doença da Artéria Coronariana , Imagens de Fantasmas , Placa Aterosclerótica , Humanos , Masculino , Feminino , Estudos Prospectivos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Idoso , Fótons , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia Coronária/métodos , Meios de Contraste
2.
J AAPOS ; : 103939, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38815649

RESUMO

Hypotony is a rare postoperative complication of strabismus surgery. Resolution has been reported to occur within 1 month of surgery. Here, we describe the case of a 14-year-old boy with prolonged hypotony maculopathy following uneventful bilateral medial rectus recession. The hypotony resolved without long-term sequela after 7 months of treatment with topical steroids and atropine. Ultrasound biomicroscopy revealed a ciliary body effusion, which we hypothesize was the cause of decreased aqueous humor production and hypotony.

3.
Int J Cardiol ; 399: 131684, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38151162

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA)-based fractional flow reserve (CT-FFR) allows for noninvasive determination of the functional severity of anatomic lesions in patients with coronary artery disease. The aim of this study was to intra-individually compare CT-FFR between photon-counting detector (PCD) and conventional energy-integrating detector (EID) CT systems. METHODS: In this single-center prospective study, subjects who underwent clinically indicated CCTA on an EID-CT system were recruited for a research CCTA on PCD-CT within 30 days. Image reconstruction settings were matched as closely as possible between EID-CT (Bv36 kernel, iterative reconstruction strength level 3, slice thickness 0.5 mm) and PCD-CT (Bv36 kernel, quantum iterative reconstruction level 3, virtual monoenergetic level 55 keV, slice thickness 0.6 mm). CT-FFR was measured semi-automatically using a prototype on-site machine learning algorithm by two readers. CT-FFR analysis was performed per-patient and per-vessel, and a CT-FFR ≤ 0.75 was considered hemodynamically significant. RESULTS: A total of 22 patients (63.3 ± 9.2 years; 7 women) were included. Median time between EID-CT and PCD-CT was 5.5 days. Comparison of CT-FFR values showed no significant difference and strong agreement between EID-CT and PCD-CT in the per-vessel analysis (0.88 [0.74-0.94] vs. 0.87 [0.76-0.93], P = 0.096, mean bias 0.02, limits of agreement [LoA] -0.14/0.19, r = 0.83, ICC = 0.92), and in the per-patient analysis (0.81 [0.60-0.86] vs. 0.76 [0.64-0.86], P = 0.768, mean bias 0.02, LoA -0.15/0.19, r = 0.90, ICC = 0.93). All included patients were classified into the same category (CT-FFR > 0.75 vs ≤0.75) with both CT systems. CONCLUSIONS: CT-FFR evaluation is feasible with PCD-CT and it shows a strong agreement with EID-CT-based evaluation when images are similarly reconstructed.


Assuntos
Angiografia por Tomografia Computadorizada , Reserva Fracionada de Fluxo Miocárdico , Humanos , Feminino , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Imagens de Fantasmas
4.
Eur Radiol Exp ; 7(1): 59, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37875769

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact of different VMI reconstructions on radiomic features in in vitro and in vivo PCD-CT datasets. METHODS: An organic phantom consisting of twelve samples (four oranges, four onions, and four apples) was scanned five times. Twenty-three patients who had undergone coronary computed tomography angiography on a first generation PCD-CT system with the same image acquisitions were analyzed. VMIs were reconstructed at 6 keV levels (40, 55, 70, 90, 120, and 190 keV). The phantoms and the patients' left ventricular myocardium (LVM) were segmented for all reconstructions. Ninety-three original radiomic features were extracted. Repeatability and reproducibility were evaluated through intraclass correlations coefficient (ICC) and post hoc paired samples ANOVA t test. RESULTS: There was excellent repeatability for radiomic features in phantom scans (all ICC = 1.00). Among all VMIs, 36/93 radiomic features (38.7%) in apples, 28/93 (30.1%) in oranges, and 33/93 (35.5%) in onions were not significantly different. For LVM, the percentage of stable features was high between VMIs ≥ 90 keV (90 versus 120 keV, 77.4%; 90 versus 190 keV, 83.9%; 120 versus 190 keV, 89.3%), while comparison to lower VMI levels led to fewer reproducible features (40 versus 55 keV, 8.6%). CONCLUSIONS: VMI levels influence the stability of radiomic features in an organic phantom and patients' LVM; stability decreases considerably below 90 keV. RELEVANCE STATEMENT: Spectral reconstructions significantly influence radiomic features in vitro and in vivo, necessitating standardization and careful attention to these reconstruction parameters before clinical implementation. KEY POINTS: • Radiomic features have an excellent repeatability within the same PCD-CT acquisition and reconstruction. • Differences in VMI lead to decreased reproducibility for radiomic features. • VMI ≥ 90 keV increased the reproducibility of the radiomic features.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Miocárdio
5.
Eur J Radiol ; 166: 111008, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37542817

RESUMO

PURPOSE: To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). METHOD: Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EID- and PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis. RESULTS: A total of 20 patients (67.5 ± 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EID-CT values (all p < 0.05). CONCLUSIONS: The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Coração , Fótons , Imagens de Fantasmas
6.
Int J Cardiovasc Imaging ; 39(10): 2083-2092, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37452987

RESUMO

This study assessed the impact of cardiac motion and in-vessel attenuation on coronary artery calcium (CAC) scoring using virtual non-iodine (VNI) against virtual non-contrast (VNC) reconstructions on photon-counting detector CT. Two artificial vessels containing calcifications and different in-vessel attenuations (500, 800HU) were scanned without (static) and with cardiac motion (60, 80, 100 beats per minute [bpm]). Images were post-processed using a VNC and VNI algorithm at 70 keV and quantum iterative reconstruction (QIR) strength 2. Calcium mass, Agatston scores, cardiac motion susceptibility (CMS)-indices were compared to physical mass, static scores as well as between reconstructions, heart rates and in-vessel attenuations. VNI scores decreased with rising heart rate (p < 0.01) and showed less underestimation than VNC scores (p < 0.001). Only VNI scores were similar to the physical mass at static measurements, and to static scores at 60 bpm. Agatston scores using VNI were similar to static scores at 60 and 80 bpm. Standard deviation of CMS-indices was lower for VNI-based than for VNC-based CAC scoring. VNI scores were higher at 500 than 800HU (p < 0.001) and higher than VNC scores (p < 0.001) with VNI scores at 500 HU showing the lowest deviation from the physical reference. VNI-based CAC quantification is influenced by cardiac motion and in-vessel attenuation, but least when measuring Agatston scores, where it outperforms VNC-based CAC scoring.

7.
Diagnostics (Basel) ; 13(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37174932

RESUMO

Background: On the basis of the hypothesis that virtual noniodine (VNI)-based coronary artery calcium scoring (CACS) is feasible at reduced radiation doses, this study assesses the impact of radiation dose reduction on the accuracy of this VNI algorithm on a photon-counting detector (PCD)-CT. Methods: In a systematic in vitro setting, a phantom for CACS simulating three chest sizes was scanned on a clinical PCD-CT. The standard radiation dose was chosen at volumetric CT dose indices (CTDIVol) of 1.5, 3.3, 7.0 mGy for small, medium-sized, and large phantoms, and was gradually reduced by adjusting the tube current resulting in 100, 75, 50, and 25%, respectively. VNI images were reconstructed at 55 keV, quantum iterative reconstruction (QIR)1, and at 60 keV/QIR4, and evaluated regarding image quality (image noise (IN), contrast-to-noise ratio (CNR)), and CACS. All VNI results were compared to true noncontrast (TNC)-based CACS at 70 keV and standard radiation dose (reference). Results: INTNC was significantly higher than INVNI, and INVNI at 55 keV/QIR1 higher than at 60 keV/QIR4 (100% dose: 16.7 ± 1.9 vs. 12.8 ± 1.7 vs. 7.7 ± 0.9; p < 0.001 for every radiation dose). CNRTNC was higher than CNRVNI, but it was better to use 60 keV/QIR4 (p < 0.001). CACSVNI showed strong correlation and agreement at every radiation dose (p < 0.001, r > 0.9, intraclass correlation coefficient > 0.9). The coefficients of the variation in root-mean squared error were less than 10% and thus clinically nonrelevant for the CACSVNI of every radiation dose. Conclusion: This phantom study suggests that CACSVNI is feasible on PCD-CT, even at reduced radiation dose while maintaining image quality and CACS accuracy.

8.
Acta Radiol ; 64(8): 2357-2362, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37157189

RESUMO

BACKGROUND: Evaluation for gastrointestinal leak is a frequent imaging indication, and dual-energy computed tomography (DECT) with oral or rectally administered contrast can be used to improve efficiency and diagnostic confidence. PURPOSE: To assess the value of the DECT iodine overlay (IO) reconstruction as a stand-alone image set compared to routine CT in assessing oral or rectal contrast leak from the gastrointestinal system. MATERIAL AND METHODS: A blinded, retrospective audit study was performed by three readers who each interpreted 50 studies performed for assessment of oral or rectal contrast leak that were acquired using DECT. Each reader independently assessed both the routine CT images and the images of the reconstructed IO for contrast leak in random order with a six-week "wash-out period" between readings. Clinical follow-up provided the reference standard. Readers recorded the presence/absence of a leak, diagnostic confidence, image quality score, and interpretation time for each image set. RESULTS: Pooled data for overall accuracy in identification of a leak increased from 0.81 (95% confidence interval [CI]=0.74-0.87) for routine CT to 0.91 (95% CI=0.85-0.95) with IO, and the area under the curve (AUC) was significantly higher for IO than routine CT (P = 0.015). Readers required significantly less time to interpret IO than routine CT (median improvement of 12.5 s per image using pooled data; P < 0.001) while maintaining diagnostic confidence and perceived image quality. CONCLUSION: Use of DECT IO reconstructions for identification of oral or rectal contrast leak requires less time to interpret than routine CT with improved accuracy and maintained diagnostic confidence and perceived image quality.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Trato Gastrointestinal , Meios de Contraste
10.
Theranostics ; 13(5): 1584-1593, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37056567

RESUMO

Purpose: It has been reported that brown adipose tissue (BAT) has a protective effect regarding cardiovascular disease. Positron emission tomography-computed tomography (PET-CT) is the reference method for detecting active BAT; however, it is not feasible to screen for BAT due to the required radionuclides and high-cost. The purpose of this study is to develop and validate a nonenhanced CT based radiomics model to detect BAT and to explore the relationship between CT radiomics derived BAT and cardiovascular calcification. Patients and methods: 146 patients undergoing 18F-FDG PET-CT were retrospectively included from two centers for model development (n = 86) and external validation (n = 60). The data for the model development were randomly divided into a training cohort and an internal validation cohort with a 7:3 ratio, while the external validation data were divided 1:1 into a propensity score matching (PSM) cohort and a randomly sex matched cohort. Radiomics features of BAT and non-BAT depots were extracted from regions of interest (ROI) on nonenhanced CT corresponding to PET studies. Inter-class correlation coefficient (ICC) and Pearson's correlation analysis were performed to select radiomics features with high consistency. Next, least absolute shrinkage and selection operator (LASSO) with linear regression model was used to select radiomics features for model construction. Support vector machine (SVM) was used to develop the model and a radiomics score (RS) was calculated for each depot. The diagnostic performance of the radiomics model was evaluated both on a per-depot and per-patient basis by calculating the area under the receiver operating characteristic curve (AUROC). We further divided patients into BAT-RS group and non-BAT-RS group based on radiomics score and compared their cardiovascular calcification by calculating calcium volume and score. Results: A total of 22 radiomics features were selected for model construction. On a per-depot basis, the AUROCs were 0.87 (95% CI: 0.83-0.9), 0.85 (95% CI: 0.79-0.90), 0.72 (95% CI: 0.67-0.77) and 0.74 (95% CI: 0.69-0.79) for detecting BAT in the training, internal validation, external validation 1 and external validation 2 cohorts, respectively. On a per-patient basis, the radiomics model had high AUROCs of 0.91 (95% CI: 0.84-0.98), 0.77 (95% CI: 0.61-0.92) and 0.85 (95% CI: 0.72-0.98) in the training, external validation 1 and external validation 2 cohorts, respectively. When grouping based on the radiomics model, the BAT-RS group had lower odds of coronary artery calcium (CAC) and thoracic aorta calcium (TAC) compared with the non-BAT-RS group (CAC: 2.8% vs. 20.3%, p = 0.001; TAC: 19.4% vs. 39.2%, p = 0.009). The BAT-RS group had less CAC volume (4.1 ± 4.0 mm3 vs. 147.4 ± 274.3 mm3; p = 0.001), CAC score (2.8 ± 3.0 vs. 169.1 ± 311.5; p = 0.001), TAC volume (301.4 ± 450.2 mm3 vs. 635.3 ± 1100.7 mm3; p = 0.007) and TAC score (496.2 ± 132.6 vs. 749.2 ± 1297.3; p = 0.007) than the non-BAT-RS group. Conclusion: We developed and validated a nonenhanced CT based reliable radiomics model for detecting BAT with PET-CT findings as reference standard. Radiomics signatures from nonenhanced CT can reliably detect BAT and have promising potential to be used in routine clinical settings. Importantly, our study showed that patients with BAT had less cardiovascular calcification.


Assuntos
Tecido Adiposo Marrom , Cálcio , Feminino , Humanos , Masculino , Tecido Adiposo Marrom/diagnóstico por imagem , Área Sob a Curva , Estudos de Coortes , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Distribuição Aleatória
11.
Diagnostics (Basel) ; 13(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36832112

RESUMO

Background: To investigate gender differences in epicardial adipose tissue (EAT) and plaque composition by coronary CT angiography (CCTA) and the association with cardiovascular outcome. Methods: Data of 352 patients (64.2 ± 10.3 years, 38% female) with suspected coronary artery disease (CAD) who underwent CCTA were retrospectively analyzed. EAT volume and plaque composition from CCTA were compared between men and women. Major adverse cardiovascular events (MACE) were recorded from follow-up. Results: Men were more likely to have obstructive CAD, higher Agatston scores, and a larger total and non-calcified plaque burden. In addition, men displayed more adverse plaque characteristics and EAT volume compared to women (all p < 0.05). After a median follow-up of 5.1 years, MACE occurred in 8 women (6%) and 22 men (10%). In multivariable analysis, Agatston calcium score (HR 1.0008, p = 0.014), EAT volume (HR 1.067, p = 0.049), and low-attenuation plaque (HR 3.82, p = 0.036) were independent predictors for MACE in men, whereas only low-attenuation plaque (HR 2.42, p = 0.041) showed predictive value for events in women. Conclusion: Women demonstrated less overall plaque burden, fewer adverse plaque characteristics, and a smaller EAT volume compared to men. However, low-attenuation plaque is a predictor for MACE in both genders. Thus, a differentiated plaque analysis is warranted to understand gender differences of atherosclerosis to guide medical therapy and prevention strategies.

12.
Eur J Radiol ; 161: 110746, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36821957

RESUMO

PURPOSE: To investigate the effect of using photon-counting detector (PCD)-CT with ultra-high resolution (UHR) on stenosis quantification accuracy and blooming artifacts from low to high heart rates in a dynamic motion phantom. METHOD: Two vessel phantoms (diameter: 4 mm) containing solid calcified lesions (25%, 50% stenoses), filled with different concentrations of iodine, inside an anthropomorphic thorax phantom attached to a coronary motion simulator were used. Scanning was performed on a PCD-CT system using an ECG-gated mode at UHR and standard resolution (SR) (0.2, 0.6 mm slice thickness, respectively). Images were reconstructed at 60, 80 and 100 beats per minute (bpm) (UHR: Bv56 kernel, quantum iterative reconstruction (QIR) level 3; SR: 55 keV, Bv40 kernel, QIR3). Percent diameter stenosis (PDS) and blooming artifacts were measured by two readers. RESULTS: PDS measurements derived from UHR were more accurate than SR for both lesions at every heart rate (p ≤ 0.005 for all, e.g. 50% lesion SR vs. UHR: at 60 bpm 57.1% [55.2-59.2] vs. 50.0% [48.5-51.2], at 100 bpm 61.0% [58.6-64.3] vs. 52.4% [51.3-54.3]). Overall mean difference across heart rates and lesions compared to the nominal stenoses was 9.2% (Limit of Agreement (LoA), 2.4%/16.0%) for SR vs. 2.4% (LoA, -2.8%/7.5%) for UHR. Blooming artifacts decreased with UHR compared to SR for both lesions at every heart rate (p < 0.001 for all, e.g. 50% lesion SR vs. UHR: at 60 bpm 63.8% [60.6-69.5] vs. 52.5% [50.0-57.5], at 100 bpm 70.2% [64.8-78.1] vs. 56.1% [51.2-60.8]). CONCLUSIONS: This motion phantom study demonstrates improved stenosis quantification accuracy and reduced blooming artifacts with UHR-PCD-CT compared to SR, independent of heart rate.


Assuntos
Angiografia por Tomografia Computadorizada , Estenose Coronária , Humanos , Constrição Patológica , Frequência Cardíaca , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Imagens de Fantasmas , Tórax
13.
Invest Radiol ; 58(9): 673-680, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36822677

RESUMO

OBJECTIVES: The aim of this study was to evaluate the impact of virtual monoenergetic imaging (VMI) and quantum iterative reconstruction (QIR) on the accuracy of coronary artery calcium scoring (CACS) using a virtual noniodine (VNI) reconstruction algorithm on a first-generation, clinical, photon counting detector computed tomography system. MATERIALS AND METHODS: Coronary artery calcium scoring was evaluated in an anthropomorphic chest phantom simulating 3 different patient sizes by using 2 extension rings (small: 300 × 200 mm, medium: 350 × 250 mm, large: 400 × 300 mm) and in patients (n = 61; final analyses only in patients with coronary calcifications [n = 34; 65.4 ± 10.0 years; 73.5% male]), who underwent nonenhanced and contrast-enhanced, electrocardiogram-gated, cardiac computed tomography on a photon counting detector system. Phantom and patient data were reconstructed using a VNI reconstruction algorithm at different VMI (55-80 keV) and QIR (strength 1-4) levels (CACS VNI ). True noncontrast (TNC) scans at 70 keV and QIR "off" were used as reference for phantom and patient studies (CACS TNC ). RESULTS: In vitro and in vivo CACS VNI showed strong correlation ( r > 0.9, P < 0.001 for all) and excellent agreement (intraclass correlation coefficient > 0.9 for all) with CACS TNC at all investigated VMI and QIR levels. Phantom and patient CACS VNI significantly increased with decreasing keV levels (in vitro: from 475.2 ± 26.3 at 80 keV up to 652.5 ± 42.2 at 55 keV; in vivo: from 142.5 [7.4/737.7] at 80 keV up to 248.1 [31.2/1144] at 55 keV; P < 0.001 for all), resulting in an overestimation of CACS VNI at 55 keV compared with CACS TNC at 70 keV in some cases (in vitro: 625.8 ± 24.4; in vivo: 225.4 [35.1/959.7]). In vitro CACS increased with rising QIR at low keV. In vivo scores were significantly higher at QIR 1 compared with QIR 4 only at 60 and 80 keV (60 keV: 220.3 [29.6-1060] vs 219.5 [23.7/1048]; 80 keV: 152.0 [12.0/735.6] vs 142.5 [7.4/737.7]; P < 0.001). CACS VNI was closest to CACS TNC at 60 keV, QIR 2 (+0.1%) in the small; 55 keV, QIR 1 (±0%) in the medium; 55 keV, QIR 4 (-0.1%) in the large phantom; and at 60 keV, QIR 1 (-2.3%) in patients. CONCLUSIONS: Virtual monoenergetic imaging reconstructions have a significant impact on CACS VNI . The effects of different QIR levels are less consistent and seem to depend on several individual conditions, which should be further investigated.


Assuntos
Cálcio , Vasos Coronários , Humanos , Masculino , Feminino , Razão Sinal-Ruído , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos
14.
Radiol Case Rep ; 18(1): 108-111, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36324834

RESUMO

Anastomotic leakage is a feared complication of many different types of gastrointestinal surgery. It is important to identify patients with leaks early because sepsis may develop quickly. Suspected leaks are typically confirmed by either fluoroscopy or computed tomography with oral contrast. This article presents a novel method to confirm the presence of a gastrointestinal anastomotic leak when standard imaging and clinical presentation are ambiguous.

15.
Front Cardiovasc Med ; 10: 1284743, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38179508

RESUMO

Background: Cardiovascular MRI is advantageous in transcatheter aortic valve implantation (TAVI) planning. This study aimed to evaluate the feasibility of comprehensive non-contrast MRI [relaxation-enhanced angiography without contrast and triggering (REACT)] combined with a three-dimensional whole-heart MRI protocol for preprocedural planning of TAVI vs. computed tomography angiography (CTA). Methods: Thirty patients with severe aortic stenosis were prospectively enrolled. The anatomical properties of the aortic root anatomy, including the perimeter and area of the virtual aortic valve annulus and coronary heights, were determined from 3D whole-heart MRI and cardiac CTA (CCTA) images, respectively. The diameters of the aorta (thoracic and abdominal aorta) and iliofemoral arteries were measured from REACT and aortic CTA (ACTA) images, respectively. A paired t-test was used to compare these two modalities. Bland-Altman plots were used to assess cardiovascular MRI and CTA measurements. Transcatheter heart valve (THV) sizing was performed based on CCTA measurements and compared with 3D whole-heart MRI measurements. The extent of annular calcification on 3D whole-heart MRI images was evaluated by a four-point grading scale and compared with CCTA data. Results: All 30 patients completed CTA and cardiovascular MRI examinations, with the TAVI procedure being administered in 25 patients. The mean acquisition time of the comprehensive MRI protocol was 18 ± 3.2 min. There were no significant differences between ACTA and REACT data in regard to the diameters of aortic and iliofemoral arteries, including the ascending thoracic aorta (37 ± 4.6 mm vs. 37.7 ± 5.2 mm, p = 0.085), descending thoracic aorta (24.3 ± 2.8 mm vs. 24.3 ± 2.8 mm, p = 0.832), abdominal aorta (20.9 ± 2.5 mm vs. 20.8 ± 2.5 mm, p = 0.602), bilateral common iliac arteries (right: 8.36 ± 1.44 mm vs. 8.42 ± 1.27 mm, p = 0.590; left: 8.61 ± 1.71 mm vs. 8.86 ± 1.46 mm, p = 0.050), and bilateral femoral arteries (right: 6.77 ± 1.06 mm vs. 6.87 ± 1.00 mm, p = 0.157; left: 6.75 ± 1.02 mm vs. 6.90 ± 0.80 mm, p = 0.142). Both modalities showed similar aortic valve morphology and semi-quantitative valve calcification (all, p's > 0.05). Overall agreement for implanted THV was found in all 25 (100%) patients assessed with both modalities. Conclusion: REACT combined with 3D whole-heart MRI enables reliable measurements of aortic root anatomy, annular calcification, and aorta and iliofemoral access in patients under evaluation for TAVI.

16.
Genes (Basel) ; 13(8)2022 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-36011402

RESUMO

Inherited retinal dystrophies (IRDs) are a group of rare diseases involving more than 340 genes and a variety of clinical phenotypes that lead to significant visual impairment. The aim of this study is to evaluate the rates and genetic characteristics of IRDs in the southeastern region of the United States (US). A retrospective chart review was performed on 325 patients with a clinical diagnosis of retinal dystrophy. Data including presenting symptoms, visual acuity, retinal exam findings, imaging findings, and genetic test results were compiled and compared to national and international IRD cohorts. The known ethnic groups included White (64%), African American or Black (30%), Hispanic (3%), and Asian (2%). The most prevalent dystrophies identified clinically were non-syndromic retinitis pigmentosa (29.8%), Stargardt disease (8.3%), Usher syndrome (8.3%), cone-rod dystrophy (8.0%), cone dystrophy (4.9%), and Leber congenital amaurosis (4.3%). Of the 101 patients (31.1%) with genetic testing, 54 (53.5%) had causative genetic variants identified. The most common pathogenic genetic variants were USH2A (n = 11), ABCA4 (n = 8), CLN3 (n = 7), and CEP290 (n = 3). Our study provides initial information characterizing IRDs within the diverse population of the southeastern US, which differs from national and international genetic and diagnostic trends with a relatively high proportion of retinitis pigmentosa in our African American or Black population and a relatively high frequency of USH2A pathogenic variants.


Assuntos
Distrofias Retinianas , Retinose Pigmentar , Transportadores de Cassetes de Ligação de ATP/genética , Antígenos de Neoplasias , Proteínas de Ciclo Celular , Proteínas do Citoesqueleto , Humanos , Glicoproteínas de Membrana , Chaperonas Moleculares , Distrofias Retinianas/diagnóstico , Distrofias Retinianas/epidemiologia , Distrofias Retinianas/genética , Retinose Pigmentar/epidemiologia , Retinose Pigmentar/genética , Estudos Retrospectivos , Literatura de Revisão como Assunto , South Carolina , Síndromes de Usher
17.
J AAPOS ; 26(4): 197-198, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35654345

RESUMO

Scheduling lag time is the time between the date of an appointment and the date an appointment was created in the scheduling system. We sought to determine the scheduling lag time in a pediatric ophthalmology clinic for children <8 years of age, referred by a primary care provider for an abnormal red reflex (ARR), cataract, leukocoria, or retinoblastoma. The median scheduling lag time was 1.8 days (IQR, 0.8-5.0). Of the 106 total appointments, 89 (84%) were completed as scheduled, 12 (11%) were canceled, and 5 (5%) were no-shows. Ten patients (12%) were never seen. There was a shorter scheduling lag time for completed visits (median, 1.1 days; IQR, 0.2-4.0) than canceled visits (median, 12.0 days; IQR, 3.1-48.5; P < 0.001). Monitoring of the scheduling lag time for urgent referrals may be a metric for quality improvement in pediatric ophthalmology.


Assuntos
Agendamento de Consultas , Oftalmologia , Instituições de Assistência Ambulatorial , Criança , Humanos , Encaminhamento e Consulta , Reflexo
18.
Front Cardiovasc Med ; 9: 1053398, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36741832

RESUMO

Purpose: To compare coronary artery calcium volume and score (CACS) between photon-counting detector (PCD) and conventional energy integrating detector (EID) computed tomography (CT) in a phantom and prospective patient study. Methods: A commercially available CACS phantom was scanned with a standard CACS protocol (120 kVp, slice thickness/increment 3/1.5 mm, and a quantitative Qr36 kernel), with filtered back projection on the EID-CT, and with monoenergetic reconstruction at 70 keV and quantum iterative reconstruction off on the PCD-CT. The same settings were used to prospectively acquire data in patients (n = 23, 65 ± 12.1 years), who underwent PCD- and EID-CT scans with a median of 5.5 (3.0-12.5) days between the two scans in the period from August 2021 to March 2022. CACS was quantified using a commercially available software solution. A regression formula was obtained from the aforementioned comparison and applied to simulate risk reclassification in a pre-existing cohort of 514 patients who underwent a cardiac EID-CT between January and December 2021. Results: Based on the phantom experiment, CACS PCD-CT showed a more accurate measurement of the reference CAC volumes (overestimation of physical volumes: PCD-CT 66.1 ± 1.6% vs. EID-CT: 77.2 ± 0.5%). CACS EID-CT and CACS PCD-CT were strongly correlated, however, the latter measured significantly lower values in the phantom (CACS PCD-CT : 60.5 (30.2-170.3) vs CACS EID-CT 74.7 (34.6-180.8), p = 0.0015, r = 0.99, mean bias -9.7, Limits of Agreement (LoA) -36.6/17.3) and in patients (non-significant) (CACS PCD-CT : 174.3 (11.1-872.7) vs CACS EID-CT 218.2 (18.5-876.4), p = 0.10, r = 0.94, mean bias -41.1, LoA -315.3/232.5). The systematic lower measurements of Agatston score on PCD-CT system led to reclassification of 5.25% of our simulated patient cohort to a lower classification class. Conclusion: CACS PCD-CT is feasible and correlates strongly with CACS EID-CT , however, leads to lower CACS values. PCD-CT may provide results that are more accurate for CACS than EID-CT.

19.
J AAPOS ; 25(2): 91.e1-91.e5, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33882352

RESUMO

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has significantly disrupted the delivery of healthcare. Although most nonurgent ophthalmology visits at Boston Children's Hospital were canceled, premature infants at risk for retinopathy of prematurity (ROP) still required timely, in-person care during the initial 3-month period of the infection surge in Massachusetts. The purpose of the current study was to report our protocols for mitigating risk of exposure to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) between infants and eye care providers and to compare examination rates and results with the same 3-month period in 2019. METHODS: During the infection surge, we added new infection control measures and strengthened existing ones. Additional personal protective equipment was used, and the number of ophthalmologists rotating in the three high-capacity NICUs we service was limited. RESULTS: More infants required ROP examinations during the study period in 2020 than in the same period in 2019, but fewer examinations were performed. There were no cases of missed progression to severe ROP during this time and no known transmission of SARS-CoV-2 between ROP patients and ophthalmology staff. CONCLUSIONS: Overall, effective ROP care was safely provided during the COVID-19 pandemic, and contact with this vulnerable population was minimized.


Assuntos
COVID-19 , Retinopatia da Prematuridade , Humanos , Lactente , Recém-Nascido , Massachusetts , Pandemias , Retinopatia da Prematuridade/epidemiologia , Fatores de Risco
20.
Circ Cardiovasc Imaging ; 14(3): e011747, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33722057

RESUMO

Radiomics uses advanced image analysis to extract massive amounts of quantitative information from digital images, which is not otherwise distinguishable to the human eye. The mined data can be used to explore and establish new and undiscovered correlations between these imaging features and clinical end points. Cardiac computed tomography (CT) is a first-line imaging modality for evaluating coronary artery disease and has a primary role in the assessment of cardiac structures. Conventional interpretation of cardiac CT images relies mostly on subjective and qualitative analysis, as well as basic geometric quantification. To date, some proof-of-concept studies have demonstrated the feasibility and diagnostic performance of cardiac CT radiomics analysis. This review describes the current literature on radiomics in cardiac CT and discusses its advantages, challenges, and future directions. Although much evidences are needed in this field, cardiac CT radiomics has a lot to offer to patients and physicians with potential to define cardiac disease phenotypes on imaging with higher precision.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos