Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
AJR Am J Roentgenol ; 217(2): 336-346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936016

RESUMO

BACKGROUND. Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. Although TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. OBJECTIVE. The purpose of this article was to investigate sensitivity, specificity, and predictive value of cardiac CTA (CCTA), cardiac MRI (CMRI), and TTE for recurrence in patients with suspected cardioembolic stroke. METHODS. We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMRI (n = 75) or CCTA (n = 76) between January 2013 and May 2017. We evaluated for the presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end point was stroke recurrence. Sensitivity, specificity, PPV, and NPV for recurrent stroke were calculated; the diagnostic accuracy of CMRI, CCTA, and TTE was compared between and within groups using AUC. RESULTS. Twelve and 14 recurrent strokes occurred in the CCTA and CMRI groups, respectively. Sensitivity, specificity, PPV, and NPV were 33.3%, 93.7%, 50.0%, and 88.2% for CCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMRI; 14.3%, 83.6%, 16.7%, and 80.9% for TTE in the CMRI group; and 8.3%, 93.7%, 20.0%, and 84.5% for TTE in the CCTA group. Accuracy was not different (p > .05) between CCTA (AUC = 0.63; 95% CI, 0.49-0.77), CMRI (0.53; 95% CI, 0.42-0.63), TTE in the CMRI group (0.51; 95% CI, 0.40-0.61), and TTE in the CCTA group (0.51; 95% CI, 0.42-0.59). In the CCTA group, atrial and ventricular thrombus were detected by CCTA in three patients and TTE in one patient; in the CMRI group, thrombus was detected by CMRI in one patient and TTE in two patients. CONCLUSION. CCTA, CMRI, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. CCTA and CMRI may be valid alternatives to TTE. CCTA may be preferred given potentially better detection of atrial and ventricular thrombus. CLINICAL IMPACT. CCTA and CMRI have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings.


Assuntos
Ecocardiografia/métodos , AVC Embólico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Eur Radiol ; 30(12): 6528-6536, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32617689

RESUMO

OBJECTIVE: To evaluate a novel fully automated mitral valve analysis software platform for cardiac computer tomography angiography (CCTA)-based structural heart therapy procedure planning. METHODS: The study included 52 patients (25 women; mean age, 66.9 ± 12.4 years) who had undergone CCTA prior to transcatheter mitral valve replacement (TMVR) or surgical mitral valve intervention (replacement or repair). Therapeutically relevant mitral valve annulus parameters (projected area, circumference, trigone-to-trigone (T-T) distance, anterior-posterior (AP) diameter, and anterolateral-posteromedial (AL-PM) diameter) were measured. Results of the fully automated mitral valve analysis software platform with and without manual adjustments were compared with the reference standard of a user-driven measurement program (3mensio, Pie Medical Imaging). Measurements were compared between the fully automated software, both with and without manual adjustment, and the user-driven program using intraclass correlation coefficients (ICC). A secondary analysis included the time to obtain all measurements. RESULTS: Fully automated measurements showed a good to excellent agreement (circumference, ICC = 0.70; projected area, ICC = 0.81; T-T distance, ICC = 0.64; AP, ICC = 0.62; and AL-PM diameter, ICC = 0.78) compared with the user-driven analysis. There was an excellent agreement between fully automated measurement with manual adjustments and user-driven analysis regarding circumference (ICC = 0.91), projected area (ICC = 0.93), T-T distance (ICC = 0.80), AP (ICC = 0.78), and AL-PM diameter (ICC = 0.79). The time required for mitral valve analysis was significantly lower using the fully automated software with manual adjustments compared with the standard assessment (134.4 ± 36.4 s vs. 304.3 ± 77.7 s) (p < 0.01). CONCLUSION: The fully automated mitral valve analysis software, when combined with manual adjustments, demonstrated a strong correlation compared with the user-driven software while reducing the total time required for measurement. KEY POINTS: • The novel software platform allows for a fully automated analysis of mitral valve structures. • An excellent agreement was found between the fully automated measurement with manual adjustments and the user-driven analysis. • The software showed quicker measurement time compared with the standard analysis of the mitral valve.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software
3.
AJR Am J Roentgenol ; 214(5): 1065-1071, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32130041

RESUMO

OBJECTIVE. The purpose of this study was to evaluate an artificial intelligence (AI)-based prototype algorithm for fully automated quantification of emphysema on chest CT compared with pulmonary function testing (spirometry). MATERIALS AND METHODS. A total of 141 patients (72 women, mean age ± SD of 66.46 ± 9.7 years [range, 23-86 years]; 69 men, mean age of 66.72 ± 11.4 years [range, 27-91 years]) who underwent both chest CT acquisition and spirometry within 6 months were retrospectively included. The spirometry-based Tiffeneau index (TI; calculated as the ratio of forced expiratory volume in the first second to forced vital capacity) was used to measure emphysema severity; a value less than 0.7 was considered to indicate airway obstruction. Segmentation of the lung based on two different reconstruction methods was carried out by using a deep convolution image-to-image network. This multilayer convolutional neural network was combined with multilevel feature chaining and depth monitoring. To discriminate the output of the network from ground truth, an adversarial network was used during training. Emphysema was quantified using spatial filtering and attenuation-based thresholds. Emphysema quantification and TI were compared using the Spearman correlation coefficient. RESULTS. The mean TI for all patients was 0.57 ± 0.13. The mean percentages of emphysema using reconstruction methods 1 and 2 were 9.96% ± 11.87% and 8.04% ± 10.32%, respectively. AI-based emphysema quantification showed very strong correlation with TI (reconstruction method 1, ρ = -0.86; reconstruction method 2, ρ = -0.85; both p < 0.0001), indicating that AI-based emphysema quantification meaningfully reflects clinical pulmonary physiology. CONCLUSION. AI-based, fully automated emphysema quantification shows good correlation with TI, potentially contributing to an image-based diagnosis and quantification of emphysema severity.


Assuntos
Inteligência Artificial , Enfisema Pulmonar/diagnóstico por imagem , Testes de Função Respiratória , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
4.
Radiol Cardiothorac Imaging ; 2(3): e190137, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33778579

RESUMO

PURPOSE: To evaluate the additional value of noninvasive artificial intelligence (AI)-based CT-derived fractional flow reserve (CT FFR), derived from triple-rule-out coronary CT angiography for acute chest pain (ACP) in the emergency department (ED) setting. MATERIALS AND METHODS: AI-based CT FFR from triple-rule-out CT angiography data sets was retrospectively obtained in 159 of 271 eligible patients (102 men; mean age, 57.0 years ± 9.7 [standard deviation]) presenting to the ED with ACP. The agreement between CT FFR (≤ 0.80) and stenosis at triple-rule-out CT angiography (≥ 50%), as well as downstream cardiac diagnostic testing, was investigated. Furthermore, the predictive value of CT FFR for coronary revascularization and major adverse cardiac events (MACE) was assessed over a 1-year follow-up period. RESULTS: CT FFR and triple-rule-out CT angiography demonstrated agreement in severity of coronary artery disease (CAD) in 52% (82 of 159) of all cases. CT FFR of 0.80 and less served as a better predictor for coronary revascularization and MACE than stenosis of 50% and greater at triple-rule-out CT angiography (odds ratio, 3.4; 95% confidence interval: 1.4, 8.2 vs odds ratio, 2.2; 95% confidence interval: 0.9, 5.3) (P < .01). In the subgroup of patients with additional noninvasive cardiac testing (94 of 159), there was higher agreement as to the presence or absence of significant disease with CT FFR (55%) than with coronary triple-rule-out CT angiography (47%) (P = .23). CONCLUSION: CT FFR derived from triple-rule-out CT angiography was a better predictor for coronary revascularization and MACE and showed better agreement with additional diagnostic testing than triple-rule-out CT angiography. Therefore, CT FFR may improve the specificity in identifying patients with ACP with significant CAD in the ED setting and reduce unnecessary downstream testing.© RSNA, 2020See also the commentary by Ihdayhid and Ben Zekry in this issue.

5.
J Cardiovasc Comput Tomogr ; 14(3): 246-250, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31843523

RESUMO

PURPOSE: To investigate the accuracy of Agatston scoring and potential for radiation dose reduction of a coronary artery calcium scoring (CACS) CT protocol at 100 kV with tin filtration (Sn100kV) and kV-independent iterative reconstruction, compared to standard 120 kV acquisitions. MATERIALS AND METHODS: With IRB approval and in HIPAA compliance, 114 patients (61.8 ± 9.6 years; 66 men) underwent CACS using a standard 120 kV protocol and an additional Sn100kV CACS scan. The two datasets were reconstructed using a medium sharp convolution algorithm and in addition the Sn100kV scans were reconstructed iteratively based on a kV-independent algorithm. Agatston scores and radiation dose values were compared between the Sn100kV and the standard 120 kV protocol. RESULTS: Median Agatston scores derived from the Sn100kV protocol with the kV-independent algorithm and the standard 120 kV were 21.4 (IQR, 0-173.8) and 24.7 (IQR, 0-171.1) respectively, with no significant differences (p=0.18). Agatston scores derived from the two different protocols had an excellent correlation (r = 0.99). The dose-length-product was 11.5 ± 4.1 mGy × cm using Sn100kV and 50.4 ± 24.9 mGy × cm using the standard 120 kV protocol (p < 0.01), resulting in a significantly lower (77%) effective dose at Sn100kV (0.16 ± 0.06 mSv vs. 0.71 ± 0.35 mSv, p < 0.01). Additionally, 99% of the patients were classified into the same risk category (0, 1-10, 11-100, 101-400, or >400) using the Sn100kV protocol. CONCLUSION: CACS at Sn100kV using the kV-independent iterative algorithm is feasible and provides high accuracy when compared to standard 120 kV scanning. Furthermore, radiation dose can be significantly reduced for this screening application in a priori healthy individuals.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Calcificação Vascular/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
6.
J Cardiovasc Comput Tomogr ; 14(2): 162-167, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31615736

RESUMO

OBJECTIVE: To evaluate the feasibility of dual-energy CT (DECT)-based iodine quantification to estimate myocardial extracellular volume (ECV) fraction in patients with and without cardiomyopathy (CM), as well as to assess its ability to distinguish healthy myocardial tissue from cardiomyopathic, with the goal of defining a threshold ECV value for disease detection. METHODS: Ten subjects free of heart disease and 60 patients with CM (mean age 66.4 ±â€¯9.4; 59 males and 11 females; 40 ischemic and 20 non-ischemic CM) underwent late iodine enhanced DECT imaging. Myocardial iodine maps were obtained using 3-material decomposition. ECV of the left ventricle was estimated from hematocrit levels and the iodine maps using the AHA 16-segment model. Receiver operating characteristic curve analysis was performed, with corresponding area under the curve, along with Youden's index assessment, to establish a threshold for CM detection. RESULTS: The median ECV for healthy myocardium, non-ischemic CM, and ischemic CM were 25.4% (22.9-27.3), 38.3% (33.7-43.0), and 36.9% (32.4-41.1), respectively. Healthy myocardium showed significantly lower ECV values compared to ischemic and non-ischemic CM (p < 0.001). From Youden's index analysis, an ECV>29.5% would indicate the presence of CM in the myocardium (sensitivity = 90.3; specificity = 90.3); the AUC for this criterion was 0.950 (p < 0.001). CONCLUSION: The findings of this study resulted in a statistically significant distinction between healthy myocardium and CM ECVs. This led to the establishment of a promising threshold ECV value that could facilitate the differentiation between healthy and diseased myocardium, and highlights the potential of this DECT methodology to detect cardiomyopathic tissue.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Miocárdio/patologia , Tomografia Computadorizada por Raios X , Idoso , Cardiomiopatias/etiologia , Cardiomiopatias/patologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sobrevivência de Tecidos
7.
J Cardiovasc Comput Tomogr ; 13(1): 81-84, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30377090

RESUMO

ObjectiveTo assess the feasibility of dual energy CT (DECT) to derive myocardial extracellular volume (ECV) and detect myocardial ECV differences without a non-contrast acquisition, compared to single energy CT (SECT). MethodsSubjects (n = 35) with focal fibrosis (n = 17), diffuse fibrosis (n = 10), and controls (n = 9) underwent non-contrast and delayed acquisitions to calculate SECT-ECV. DECT-ECV was calculated using the delayed acquisition and the derived virtual non-contrast images. In the control and diffuse fibrotic groups, the entire myocardium of the left ventricle was used to calculate ECV. Two ROIs were placed in the focal fibrotic group, one in normal and one in fibrotic myocardium. ResultsMedian ECV was 33.4% (IQR, 30.1-37.4) using SECT and 34.9% (IQR, 31.2-39.2) using DECT (p = 0.401). For both techniques, focal and diffuse fibrosis had significantly higher ECV values (all p < 0.021) than normal myocardium. There was no systematic bias between DECT and SECT (p = 0.348). SECT had a higher radiation dose (1.1 mSv difference) than DECT (p < 0.001). ConclusionECV can be measured using a DECT approach with only a delayed acquisition. The DECT approach provides similar results at a lower radiation dose compared to SECT.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cardiomiopatias/patologia , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Fibrose , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/efeitos adversos
8.
Int J Cardiol ; 268: 236-240, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29804697

RESUMO

BACKGROUNDS: Cardiac magnetic resonance (CMR) T1 mapping and the extracellular volume (ECV) have been developed to quantitative analysis of diffusely abnormal myocardial fibrosis (MF). However, dual-energy CT (DECT) has a potential for calculation of ECV. The aim of this study is to evaluate the feasibility and accuracy of DECT technique in determining the ECV in patients with heart failure, with 3T CMR as the reference. METHODS: Thirty-five patients with various reasons of heart failure were enrolled in this study. Both DECT and CMR exams were completed within 24 h. ECVs were calculated, and the relationship between DECT-ECV, CMR-ECV, and other heart function parameters, including left ventricular end systolic and diastolic volume, cardiac output and ejection fraction (LVESV, LVEDV, CO, LVEF), Brain natriuretic peptide (BNP) was determined. All participants gave informed consent, and the study was approved by the institutional review board. RESULTS: The median ECVs on DECT and CMR were 33% (95%CI: 32%-36%) and 30% (95%CI: 30% - 32%), respectively. A good correlation between myocardial ECV at DECT and that at CMR (r = 0.945, P < 0.001) was observed. Bland-Altman analysis between DECT and CMR showed a small bias (2.6%), with 95% limits of agreement of -0.4% and 5.6%. Interobserver agreement for ECV at DECT was excellent (ICC = 0.907). Both ECVs, for DECT and CMR, were inversely associated with LVEF and CO. CONCLUSION: DECT-based ECV could be an alternative non-invasive imaging tool for myocardial tissue characterization. However, overestimation of the extent of diffuse MF is observed with use of DECT.


Assuntos
Tamanho Celular , Líquido Extracelular/fisiologia , Insuficiência Cardíaca/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X/normas
9.
Eur Radiol ; 28(10): 4195-4204, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29666993

RESUMO

PURPOSE: To evaluate image quality of non-contrast-enhanced magnetic resonance angiography (MRA) and compare transplant renal artery stenosis (TRAS) seen by non-contrast-enhanced MRA with digital subtraction angiography (DSA) as the gold standard. MATERIALS AND METHODS: 330 patients receiving 369 non-contrast-enhanced MRA examinations from July 2014 to June 2017 were included. Thirty patients received at least two MRA examinations. Image quality was independently assessed by two radiologists. Inter-observer agreement was analyzed. Transplant renal artery anatomy and complications were evaluated and compared with DSA. If possible, accuracy was calculated on a per-artery basis. RESULTS: Good or excellent image quality was found in 95.4 % (352/369) of examinations with good inter-observer agreement (K=0.760). Twenty-two patients with DSA had 28 non-contrast-enhanced MRA examinations within a 2-month period. Of these, 19 patients had TRAS, two patients had pseudoaneurysms, and one patient had a normal transplant renal artery but an occluded external iliac artery. Non-contrast-enhanced MRA correctly detected 19 TRAS and nine normal arteries, giving 96.6 % accuracy on a per-artery basis. CONCLUSIONS: Non-contrast-enhanced MRA demonstrates a good depiction of the transplanted renal artery and shows good correlation with DSA in cases where there was TRAS. KEY POINTS: • Good or excellent image quality was found in 95.4 % of examinations. • Non-contrast-enhanced MRA can clearly map transplant renal artery anatomy. • Non-contrast-enhanced MRA is a reliable tool to detect TRAS.


Assuntos
Transplante de Rim , Angiografia por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Adolescente , Adulto , Idoso , Angiografia Digital , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Complicações Pós-Operatórias/patologia , Artéria Renal/diagnóstico por imagem , Artéria Renal/patologia , Obstrução da Artéria Renal/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
10.
J Magn Reson Imaging ; 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-29446527

RESUMO

BACKGROUND: Binary threshold-based quantification techniques ignore myocardial infarct (MI) heterogeneity, yielding substantial misquantification of MI. PURPOSE: To assess the technical feasibility of MI quantification using percent infarct mapping (PIM), a prototype nonbinary algorithm, in patients with suspected MI. STUDY TYPE: Prospective cohort POPULATION: Patients (n = 171) with suspected MI referred for cardiac MRI. FIELD STRENGTH/SEQUENCE: Inversion recovery balanced steady-state free-precession for late gadolinium enhancement (LGE) and modified Look-Locker inversion recovery (MOLLI) T1 -mapping on a 1.5T system. ASSESSMENT: Infarct volume (IV) and infarct fraction (IF) were quantified by two observers based on manual delineation, binary approaches (2-5 standard deviations [SD] and full-width at half-maximum [FWHM] thresholds) in LGE images, and by applying the PIM algorithm in T1 and LGE images (PIMT1 ; PIMLGE ). STATISTICAL TEST: IV and IF were analyzed using repeated measures analysis of variance (ANOVA). Agreement between the approaches was determined with Bland-Altman analysis. Interobserver agreement was assessed by intraclass correlation coefficient (ICC) analysis. RESULTS: MI was observed in 89 (54.9%) patients, and 185 (38%) short-axis slices. IF with 2, 3, 4, 5SDs and FWHM techniques were 15.7 ± 6.6, 13.4 ± 5.6, 11.6 ± 5.0, 10.8 ± 5.2, and 10.0 ± 5.2%, respectively. The 5SD and FWHM techniques had the best agreement with manual IF (9.9 ± 4.8%) determination (bias 1.0 and 0.2%; P = 0.1426 and P = 0.8094, respectively). The 2SD and 3SD algorithms significantly overestimated manual IF (9.9 ± 4.8%; both P < 0.0001). PIMLGE measured significantly lower IF (7.8 ± 3.7%) compared to manual values (P < 0.0001). PIMLGE , however, showed the best agreement with the PIMT1 reference (7.6 ± 3.6%, P = 0.3156). Interobserver agreement was rated good to excellent for IV (ICCs between 0.727-0.820) and fair to good for IF (0.589-0.736). DATA CONCLUSION: The application of the PIMLGE technique for MI quantification in patients is feasible. PIMLGE , with its ability to account for voxelwise MI content, provides significantly smaller IF than any thresholding technique and shows excellent agreement with the T1 -based reference. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...