Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 36(2): 616-622, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32896438

RESUMO

BACKGROUND: We assessed the survivorship of a proximally hydroxyapatite coated, double tapered, titanium-alloy femoral stem in a single center, at an average follow up of 12.5 years (10.1-15.8). The majority of stems were inserted as part of a Metal on Metal (MoM) Total Hip Replacement (THR). METHODS: Data was collected prospectively in a local database. A retrospective review was performed of all patients undergoing a primary THR with the prosthesis between 2003 and 2010. Primary outcome was revision of the stem for any cause. Analysis was also performed for stem revision for aseptic loosening, stem revision in the MoM setting and a worst case scenario whereby lost to follow up were presumed to have failed. True stem failure was considered if revision occurred for a stem related complication. RESULTS: 1465 stems were included (1310 patients, 155 bilateral). The bearing surface was cobalt chrome on cobalt chrome in 1351 cases (92%). Seven hips were lost to follow up. Thirty-two stems (31 part of a MoM THR) underwent revision for any cause. Kaplan Meier survival analysis demonstrates an overall 97.4% survivorship. Subset analysis demonstrates 100% survivorship for aseptic loosening, 97.3% in the MoM setting and 96.7% for the worst case senario. Of the 32 cases of stem revision, only 13 were classified as 'true' stem failure. CONCLUSION: This study represents the largest cohort of this uncemented femoral component with a minimum follow-up longer than 10 years. Our results demonstrate excellent long-term survivorship even in the presence of a challenging MoM environment.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Ligas , Artroplastia de Quadril/efeitos adversos , Durapatita , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Titânio , Resultado do Tratamento
2.
Arch Orthop Trauma Surg ; 140(11): 1825-1835, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32852593

RESUMO

INTRODUCTION: Acetabular component revision surgery can be a challenging task due to the encountered bone defects. Both cemented and uncemented techniques are described. We report on the survivorship of the Thackray cross plate with rim reinforcement ring for cemented acetabular revision. PATIENTS AND METHODS: This is a retrospective case series of all patients treated with the implant with a minimum follow-up of 2 years. Acetabular defects were characterized according to the Paprosky classification. Data on potential risk factors for failure of the construct as well as the Oxford Hip Score (OHS) were collected. Kaplan-Meier survival analysis with radiographic aseptic loosening or revision for aseptic loosening as the end point was performed. RESULTS: From 2000 to 2017, 35 revisions in 18 male and 17 female patients with an average age of 72 years were included. Bone allograft was used in 26 cases and additional implants (medial or supero-lateral mesh) in 13. Seven patients have deceased and the fate of all revisions is known. At an average clinical follow-up of 9.7 (2.6 to 19.6) years, there were no further re-revisions for construct failure. Five hips have demonstrated radiological evidence of aseptic loosening. Radiologically loose components were associated with more severe grades of acetabular bone defects (Paprosky Type 3) (60% vs 3%, p = 0.006). Kaplan-Meier survival analysis demonstrates 79.8% overall survivorship at 7 years. Survivorship for Type 2 defects was significantly higher compared to Type 3 (90% vs 0% at 7 years, Logrank test p = 0.002, Cox proportional hazards p = 0.03). The final median OHS was 38 (12-48) and was not affected by component loosening. CONCLUSION: This is a cost-effective device that protects the underlying bone graft (81% complete remodeling) and prevents subsidence of the cemented cup (2 mm on average). It should be used with caution in high-grade defects and perhaps not advised.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Placas Ósseas , Prótese de Quadril , Reoperação , Idoso , Transplante Ósseo , Feminino , Humanos , Masculino , Falha de Prótese , Estudos Retrospectivos
3.
J Arthroplasty ; 34(8): 1749-1754, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31060920

RESUMO

BACKGROUND: Metal-on-metal total hip arthroplasties (MoM THAs) are frequently revised, though there is a paucity of functional outcome data. We report on outcomes and prognostic factors predictive of outcome from the largest series of MoM THA revisions to date. METHODS: A single-center consecutive series of revisions from MoM THAs was identified. The cohort was divided by the presence or absence of symptoms prior to revision. The primary outcome was functional outcome (Oxford Hip Score [OHS]). Secondary outcomes were complication data, pre-revision and post-revision blood metal ions, and modified Oxford classification of pre-revision magnetic resonance imaging. RESULTS: One hundred eighty revisions at median follow-up of 5.48 years were identified. Median OHS improved from 29 to 37 with revision (P < .001). Symptomatic patients experienced the greatest functional benefit (ΔOHS 6.5 vs 1.4, P = .012), while the function of asymptomatic patients was unaffected by revision (P = .4). Use of a cobalt-chromium-containing bearing surface at revision and increased body mass index were predictive of poor functional outcome. CONCLUSION: Symptomatic patients experience greater functional benefit from revision surgery but do not regain the same level of function as patients who were asymptomatic prior to revision. Body mass index and use of cobalt-chromium-containing bearing surfaces are prognostic for poor functional outcome.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Falha de Prótese , Reoperação/métodos , Idoso , Índice de Massa Corporal , Cromo/sangue , Cobalto/sangue , Estudos de Coortes , Feminino , Seguimentos , Humanos , Íons , Imageamento por Ressonância Magnética , Masculino , Metais , Pessoa de Meia-Idade , Prognóstico , Resultado do Tratamento
4.
J Arthroplasty ; 30(12): 2333-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26239233

RESUMO

The aim of this study was to biomechanically evaluate the Locking attachment plate (LAP) construct in comparison to a Cable plate construct, for the fixation of periprosthetic femoral fractures after cemented total hip arthroplasty. Each construct incorporated a locking compression plate with bi-cortical locking screws for distal fixation. In the Cable construct, 2 cables and 2 uni-cortical locking screws were used for proximal fixation. In the LAP construct, the cables were replaced by a LAP with 4 bi-cortical locking screws. The LAP construct was significantly stiffer than the cable construct under axial load with a bone gap (P=0.01). The LAP construct offers better axial stiffness compared to the cable construct in the fixation of comminuted Vancouver B1 proximal femoral fractures.


Assuntos
Artroplastia de Quadril/efeitos adversos , Parafusos Ósseos , Fios Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/cirurgia , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Placas Ósseas , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/fisiopatologia , Fêmur/lesões , Fêmur/cirurgia , Fraturas Cominutivas/etiologia , Fraturas Cominutivas/fisiopatologia , Humanos , Modelos Anatômicos , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/fisiopatologia , Fraturas Periprotéticas/cirurgia , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...