Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 14(17): 1917-1923, 2021 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-34391704

RESUMO

OBJECTIVES: The aim of this study was to evaluate the 1-year safety and efficacy of a dual-layered stent (DLS) for carotid artery stenting (CAS) in a multicenter registry. BACKGROUND: DLS have been proved to be safe and efficient during short-term follow-up. Recent data have raised the concern that the benefit of CAS performed with using a DLS may be hampered by a higher restenosis rate at 1 year. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system at 20 centers. The primary endpoint was the occurrence of death and stroke at 1 year. Secondary endpoints were 1-year rates of transient ischemic attack, acute myocardial infarction, internal carotid artery (ICA) restenosis, in-stent thrombosis, and external carotid artery occlusion. RESULTS: At 1 year, follow-up was available in 726 patients (99.04%). Beyond 30 days postprocedure, 1 minor stroke (0.13%), four transient ischemic attacks (0.55%), 2 fatal acute myocardial infarctions (0.27%), and 6 noncardiac deaths (1.10%) occurred. On duplex ultrasound examination, ICA restenosis was found in 6 patients (0.82%): 2 total occlusions and 4 in-stent restenoses. No predictors of target ICA restenosis and/or occlusion could be detected, and dual-antiplatelet therapy duration (90 days vs 30 days) was not found to be related to major adverse cardiovascular event or restenosis occurrence. CONCLUSIONS: This real-world registry suggests that DLS use in clinical practice is safe and associated with minimal occurrence of adverse neurologic events up to 12-month follow-up.


Assuntos
Estenose das Carótidas , Artéria Carótida Interna , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Humanos , Estudos Prospectivos , Stents , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 13(18): 2170-2177, 2020 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-32861633

RESUMO

OBJECTIVES: This study sought to evaluate 30-day safety and efficacy of dual-layer mesh-covered carotid stent systems for carotid artery stenting (CAS) in the clinical practice. BACKGROUND: When compared with carotid endarterectomy, CAS has been associated with a higher rate of post procedural neurologic events; these could be related to plaque's debris prolapsing through stent's mesh. Consequently, the need for increased plaque coverage has resulted in the development of dual-layer mesh-covered carotid stent systems. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system in 20 centers. The primary endpoint was stroke up to 30 days; secondary endpoints were technical and procedural success; external carotid artery occlusion; and in-hospital and 30-day transient ischemic attack (TIA), acute myocardial infarction (AMI), and death rates. RESULTS: Symptoms were present in 131 (17.87%) patients. An embolic protection device was used in 731 (99.72%) patients. Procedural success was 100%, technical success was obtained in all but 1 (99.86%) patient, who died in hospital due to a hemorrhagic stroke. Six TIAs, 2 minor strokes, and 1 AMI occurred during in-hospital stay, and external carotid artery occlusion was evident in 8 (1.09%) patients. Between hospital discharge and 30-day follow-up, 2 TIAs, 1 minor stroke, and 3 AMIs occurred. Therefore, the cumulative stroke rate was 0.54%. CONCLUSIONS: This real-world registry suggests that use of CGuard embolic prevention system in clinical practice is safe and associated with a minimal occurrence of adverse neurological events up to 30-day follow-up.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Humanos , Estudos Prospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
3.
Rev Recent Clin Trials ; 14(4): 292-295, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31560293

RESUMO

BACKGROUND: Coronary calcified lesions may limit optimal stent deployment resulting in stent underexpansion, increasing the risk of thrombosis. The Shockwave Lithoplasty System, a new technology combining a balloon angioplasty catheter with the use of sound waves, it is able to break calcium deposits without affecting vascular soft tissue. CASE PRESENTATION: An 80-year-old Caucasian man with ST elevation myocardial infarction underwent emergent coronary angiography showing complete intrastent thrombosis at the proximal trait of LAD. After thrombus removal, it was evident that stent under-expansion at its proximal edge was caused by vascular calcification. Coronary shockwave lithoplasty was chosen to treat this lesion. After calcium deposits disruption we were able to obtain complete stent expansion. CONCLUSION: Our case demonstrates the usefulness and safety of the lithoplasty system in the context of ST elevation myocardial infarction.


Assuntos
Estenose Coronária/terapia , Litotripsia/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Stents/efeitos adversos , Idoso de 80 Anos ou mais , Angiografia Coronária , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Humanos , Masculino , Falha de Prótese , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Ultrassonografia de Intervenção
4.
Cardiology ; 142(3): 175-179, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31212301

RESUMO

Anomalies of the coronary arteries represent rare congenital disorders, which are characterized by a wide spectrum of clinical manifestations. Usually, they are asymptomatic, but sometimes they cause myocardial ischemia or sudden cardiac death. Here, we describe the case of a patient who suffered from angina. Coronary angiography revealed an ectopic origin of the left anterior descending coronary artery from the proximal trait of the right coronary artery and the left circumflex artery, originating from the left sinus; the whole coronary tree was free of atherosclerosis. To better define the coronary anatomy, we performed computed tomography angiography with a three-dimensional reconstruction. The patient was discharged from the clinic after 48 h under optimal medical treatment.


Assuntos
Angina Pectoris/etiologia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Idoso , Cateterismo Cardíaco , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Anomalias dos Vasos Coronários/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X
5.
Clin Med Insights Case Rep ; 12: 1179547619828707, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30792580

RESUMO

PURPOSE: The Shockwave Lithoplasty System represents a novel technology combining a balloon angioplasty catheter with the use of sound waves. Evidences suggest that it is a reliable tool to overcome calcified stenosis in both peripheral and coronary arteries. Here, we describe the case of a patient with calcified innominate artery stenosis successfully treated with the Shockwave Lithoplasty System. CASE REPORT: A 78-year-old woman with hypertension, and dyslipidemia, came to our observation for dizziness. Instrumental examinations showed critical calcified stenosis of the innominate artery. The lesion was successfully treated with the Shockwave Lithoplasty System and subsequent stent apposition. Final angiography demonstrated excellent position of the stent, good wall apposition, and confirmed patency of the right common and right vertebral artery origins. CONCLUSION: Our clinical experience demonstrates that Lithoplasty is safe and effective also for the treatment of supra-aortic vessels.

6.
J Cardiol Cases ; 19(1): 33-35, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30693057

RESUMO

Kounis syndrome refers to an acute coronary syndrome, consequent to an allergic reaction. It results from mast cell degranulation with subsequent release of numerous inflammatory mediators, leading to coronary vasospasm, atheromatous plaque rupture, or stent thrombosis. Here, we describe the case of a 47-year-old Caucasian man with acute stent thrombosis, as a consequence of allergic reaction to contrast media. .

7.
J Cardiol Cases ; 20(4): 135-137, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31969943

RESUMO

Heavily calcified lesions may limit optimal stent deployment resulting in stent underexpansion, thus increasing the risk of restenosis and thrombosis. We describe the case of overlapping stents underexpansion treated with a shockwave intravasuclar lithoplasty system (Shockwave Medical Inc., Santa Clara, CA, USA). A 65-year-old man with angina, underwent coronary angiography and intravascular ultrasound showing restenosis, in a site of overlapping stents, due to calcified tissue. Shockwave lithoplasty balloon was able to break calcified tissue in a site of overlapping stents, allowing subsequent vessel dilation and repeat stent implantation with optimal final stent expansion. Heavily calcified lesions may limit optimal stent deployment resulting in stent underexpansion. Treating stent underexpansion or restenosis due to calcified tissue is a great challenge. Shockwave lithoplasty is effective in breaking calcified tissue also in a site of overlapping stents. The improved plaque compliance allows to repeat stent implantation with optimal final stent expansion.

9.
Cardiology ; 141(2): 75-77, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30408797

RESUMO

We report the case of a stent under-expansion due to heavily calcified plaque treated with the shockwave lithoplasty system. A 77-year-old woman underwent coronary angiography, and intravascular ultrasound revealed stent under-expansion due to calcified plaque. Shockwave lithoplasty balloon was used to disrupt calcium deposits around the stent, thereby allowing a correct stent expansion with an excellent angiographic and intravascular ultrasound result.


Assuntos
Doença da Artéria Coronariana/terapia , Litotripsia/métodos , Placa Aterosclerótica/terapia , Stents , Idoso , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Ultrassonografia de Intervenção
10.
Cardiology ; 141(3): 167-171, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30630180

RESUMO

Coronary calcification is a hard challenge for the interventional cardiologist, as it is associated with incomplete stent expansion and frequently stent failure. In recent years, innovative techniques, such as rotational atherectomy, have been developed to treat coronary calcification. However, these are burdened with an increased procedural risk. We report the case of a 60-year-old Caucasian man treated 1 month before at another center with primary coronary angioplasty and stenting of the ramus intermedius for coronary syndrome. Coronary angiography showed a critical stenosis of the left main coronary artery as well as critical calcified stenosis of the left anterior descending artery and the diagonal branch. Coronary calcification was treated with rotational atherectomy that preceded the angioplasty and stenting. Because of persistence of the symptomatology, coronary angiography was repeated 1 month later and showed a critical calcified restenosis of the ramus intermedius at the site of the previous stenting. Considering the high risk of traditional atherectomy, we performed lithotripsy-enhanced disruption of calcium beyond the stents with the Shockwave Coronary Lithoplasty System. The Shockwave Coronary Lithoplasty System has been introduced recently in order to treat calcified coronary lesions with greater safety. The procedure allows most calcified coronary lesions to be treated with simplicity and safety. This system employs sound waves, similar to those used for treating kidney stones, to crush the calcified lesions. We present the first case described to date in whom this technique was successfully used to treat calcified restenosis in a previous stent.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Litotripsia/métodos , Calcificação Vascular/terapia , Angioplastia Coronária com Balão/efeitos adversos , Aterectomia Coronária , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Stents/efeitos adversos , Resultado do Tratamento , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/etiologia
12.
J Cardiovasc Med (Hagerstown) ; 14(10): 740-4, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22914309

RESUMO

The prevalence of isolated right ventricular infarction is 0.4-2.4% in autopsy series and may occur by at least three different mechanisms, of which occlusion of a nondominant right coronary artery is reviewed here. Although rare, as oxygen demand/supply of the right is lower than that of the left ventricle, due to the smaller muscular mass, and it has a good prognosis, sudden death and cardiac rupture have been reported. Differential diagnosis with anterior infarction is needed. ECG may help but specific criteria should be adopted: dome-like and decreasing ST segment elevation from V1 to V3 leads; rapid ST segment normalization and no Q wave evolution from V1 to V3 leads, either accompanied or not by modest ST segment elevation in DIII (but not aVF) evolving in no Q wave; ST segment elevation in right-sided leads which should be explored; absence of ST segment depression in aVL; absent concomitant ST segment elevation in all inferior leads (DII, DIII, aVF). Applying these criteria may prevent erroneous management of right ventricular infarction if it is confused with left ventricular infarction. Right ventricular function evaluation should always be performed by echocardiography. Magnetic resonance imaging should be useful. An illustrative case and an ECG flow-chart are presented.


Assuntos
Anomalias dos Vasos Coronários/complicações , Eletrocardiografia , Ventrículos do Coração/fisiopatologia , Infarto Miocárdico de Parede Inferior/diagnóstico , Função Ventricular Direita , Angioplastia Coronária com Balão/instrumentação , Infarto Miocárdico de Parede Anterior/diagnóstico , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/fisiopatologia , Diagnóstico Diferencial , Erros de Diagnóstico/prevenção & controle , Humanos , Infarto Miocárdico de Parede Inferior/etiologia , Infarto Miocárdico de Parede Inferior/fisiopatologia , Infarto Miocárdico de Parede Inferior/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Stents , Resultado do Tratamento
14.
Open Cardiovasc Med J ; 4: 151-6, 2010 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-20922049

RESUMO

BACKGROUND: There is some controversy as to whether tirofiban or eptifibatide, two small anti-aggregating drugs (AAD), may reduce the incidence of composite ischemic events within one year in patients undergoing percutaneous coronary intervention (PCI) in the real clinical world. METHODS: We compared consecutive patients on oral double AAD (with clopidogrel and aspirin) who underwent PCI (n=207) and patients who were on single AAD and received a second AAD, just prior to PCI, and either high-dose tirofiban or double-bolus eptifibatide (double AAD plus small molecules group, n=666). The primary end point (incidence of composite ischemic events within one year) included death, acute myocardial infarction, unstable angina, stent thrombosis or repeat PCI or coronary bypass surgery (related to the target vessel PCI failure) and was modelled by Cox's regression. RESULTS: There were 89 composite ischemic events: 24 (11.6%) in double AAD alone and 65 (9.8%) in double AAD plus small molecules groups (log-rank test: p=0.36). Incidences by type of ischemic events were similar between the 2 groups. Based on 21 potential covariates fitted simultaneously, adjusted hazard ratios (HR and 95% confidence intervals) showed that age (HR 1.03, 1.01-1.06, p=0.01), diabetes (HR 1.68, 1.01-2.79, p=0.05) and intra aortic balloon pump (HR 5.12, 2.36-11.10, p=0.0001) were significant risk factors whereas thrombolysis by tenecteplase (HR 0.35, 0.13-0.98, p=0.05) and having had hypertension or anti-hypertensive treatment (HR 0.58, 0.36-0.93, p=0.03) were significant protectors for events. Whether small molecules were present provided a non significant additional benefit as compared to double AAD alone (HR 0.83, 0.51-1.36, p=0.46). Pre-PCI CK-MB were not useful to predict events (HR 1.01, 0.99-1.01, p=0.17). CONCLUSIONS: In clinical world patients undergoing PCI (rescue plus primary <13%) while on double AAD, based on clopidogrel plus aspirin, small molecules (tirofiban or eptifibatide) provided no additive long-term protection against the occurrence of composite ischemic events whereas thrombolysis by tenecteplase did.

15.
Heart Surg Forum ; 10(5): E411-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17855209

RESUMO

Images are presented of coronary reperfusion that occurred shortly after insertion of an intra-aortic balloon pump for counter-pulsation in 3 patients with acute myocardial infarction refractory to thrombolytic therapy and hemodynamic derangement. It is shown that prophylactic intra-aortic balloon pump use may facilitate percutaneous coronary intervention during acute myocardial infarction and it is useful to provide a visual assessment of myocardial flow restoring.


Assuntos
Balão Intra-Aórtico/métodos , Infarto do Miocárdio/cirurgia , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Circulação Coronária , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...