Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 170(1-4): 86-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26763903

RESUMO

The European Dosimetry Group (EURADOS) first started performing international intercomparisons for whole-body dosemeters for individual monitoring services in 1998. Since 2008, these whole-body intercomparisons have been performed on a regular basis. In this latest intercomparison (IC2014), 96 monitoring services from 35 countries (mostly European) participated with 112 dosimetry systems. Unlike in the previous intercomparisons, the whole registration, communication and data exchange process was handled by a new on-line platform. All dosemeter irradiations were carried out in the Seibersdorf accredited dosimetry laboratory. The irradiation plan consisted of nine irradiation setups with five different photon radiation qualities (S-Cs, S-Co, RQR7, W-80 and W-150) and two different angles of radiation incidence (0° and 60°). The paper describes and analyses the individual results for the personal dose equivalent quantities Hp(10) and if requested, Hp(0.07), for all participating systems and compares these results with the ISO 14146 'trumpet curve' performance criteria. The results show that 100 systems (89 % of all systems) do fulfil the general ISO 14146 performance criteria. This paper gives an overview on the performance of the participating individual monitoring services and the influence of the dosemeter type on the observed response values.


Assuntos
Doses de Radiação , Dosímetros de Radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/métodos , Calibragem , Sistemas Computacionais , Europa (Continente) , Humanos , Luminescência , Fótons , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação , Reprodutibilidade dos Testes , Dosimetria Termoluminescente/métodos , Contagem Corporal Total/instrumentação
2.
Radiat Prot Dosimetry ; 170(1-4): 90-4, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26763905

RESUMO

In 2008 the European Radiation Dosimetry Group (EURADOS) started a new programme of intercomparisons for individual monitoring services (IMS). The aim was to provide the possibility to IMS in Europe to participate in dosimetry intercomparions with regular time intervals with all types of dosemeter systems that are used routinely to monitor workers for exposure to external radiation. A self-evaluation of the programme shows that, apart from a few problems encountered, the programme can be judged as fit for its purpose. The results of a questionnaire among the participants support this conclusion. The conclusions encourage EURADOS to continue this programme of self-sustained intercomparisons for IMS.


Assuntos
Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Europa (Continente) , Humanos , Cooperação Internacional , Fótons , Controle de Qualidade , Dosímetros de Radiação , Valores de Referência , Inquéritos e Questionários
3.
Radiat Prot Dosimetry ; 144(1-4): 202-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21450703

RESUMO

During readout, the signal of the TLD is occasionally polluted with spurious signals. These most often take the shape of a spike on the glow curve. Often these spikes are only a few milliseconds wide but can have a height that significantly influences the outcome of the dose evaluation. The detection of spikes relies generally on comparing the raw glow curve with a smoothed version of it. A spike is detected when the height of the glow curve exceeds that of the smoothed curve, using criteria based on the absolute and relative differences. The procedure proposed is based on smoothing by an optimal Wiener filter, which is, on its turn, based on Fourier analysis for which numerically very efficient methods are available. Apart from having easy to understand tuning parameters, an attractive bonus is that, with only little additional computational effort, estimates of the position of peak maxima are found from second and third derivatives: a useful feature for glow curve quality control.


Assuntos
Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Dosimetria Termoluminescente/instrumentação , Algoritmos , Interpretação Estatística de Dados , Análise de Fourier , Humanos , Modelos Estatísticos , Controle de Qualidade , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiometria/instrumentação , Software , Dosimetria Termoluminescente/métodos
4.
Radiat Prot Dosimetry ; 144(1-4): 275-81, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21196458

RESUMO

This paper presents the results of an intercomparison for extremity dosemeters organised by the European radiation dosimetry group in 2009. In total, 59 systems were tested during this exercise including ring, stall and wrist dosemeters. A total of 1652 dosemeters were irradiated in the selected fields of photons and beta radiation qualities on appropriate phantoms (ISO finger and pillar phantom) in the dose quantity H(p)(0.07). All irradiations were carried out in selected accredited reference dosemetry laboratories (Seibersdorf Laboratories, Austria and IRSN, France). The results show that, especially at low-energy beta radiations ((85)Kr) and for beta irradiations with large angles of incidence (60°), many tested systems show pronounced under responses. On the other hand, for photon irradiations down to energies of 16 keV most systems showed good results. A participants meeting was held at IM2010 with discussion on both general aspects of this intercomparison and specific problems.


Assuntos
Dosimetria Fotográfica/normas , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Radiometria/normas , Tornozelo/efeitos da radiação , Europa (Continente) , Dosimetria Fotográfica/métodos , Humanos , Imagens de Fantasmas , Fótons , Controle de Qualidade , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Imagem Corporal Total , Punho/efeitos da radiação
5.
Radiat Prot Dosimetry ; 144(1-4): 266-74, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21242166

RESUMO

Within EURADOS working group 2, a system for self-sustained intercomparisons for individual monitoring services for external radiation was developed. With the intercomparison results, the participants can show compliance within their quality management system, compare their results with those from other participants and develop plans for improvement of their system. The costs of the exercises are covered by the participants fees. In this programme, the first intercomparison exercise for whole-body dosemeters has been executed in 2008 with 62 participating dosimetry systems from participants across Europe. In general, film systems show the largest deviations, although the results of some participants indicate that it is possible to achieve results with a film system with similar quality as for thermoluminescence dosimetry (TLD) systems. A second intercomparison has been organised for extremity dosemeters in 2009. For 2010 it is planned to organise a second intercomparison for whole-body dosemeters.


Assuntos
Dosimetria Fotográfica/normas , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Radiometria/normas , Europa (Continente) , Dosimetria Fotográfica/métodos , Humanos , Desenvolvimento de Programas , Controle de Qualidade , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Inquéritos e Questionários , Imagem Corporal Total
6.
Radiat Prot Dosimetry ; 127(1-4): 461-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17627958

RESUMO

In order to arrive at recommendations for guidelines on maximum allowable quantities of radioactive material in laboratories, a proposed mathematical model was used for the calculation of transfer fractions for the air pathway. A set of incident scenarios was defined, including spilling, leakage and failure of the fume hood. For these 'common incidents', dose constraints of 1 mSv and 0.1 mSv are proposed in case the operations are being performed in a controlled area and supervised area, respectively. In addition, a dose constraint of 1 microSv is proposed for each operation under regular working conditions. Combining these dose constraints and the transfer fractions calculated with the proposed model, maximum allowable quantities were calculated for different laboratory operations and situations. Provided that the calculated transfer fractions can be experimentally validated and the dose constraints are acceptable, it can be concluded from the results that the dose constraint for incidents is the most restrictive one. For non-volatile materials this approach leads to quantities much larger than commonly accepted. In those cases, the results of the calculations in this study suggest that limitation of the quantity of radioactive material, which can be handled safely, should be based on other considerations than the inhalation risks. Examples of such considerations might be the level of external exposure, uncontrolled spread of radioactive material by surface contamination, emissions in the environment and severe accidents like fire.


Assuntos
Poluentes Radioativos do Ar/análise , Poluentes Radioativos do Ar/farmacocinética , Bioensaio/métodos , Exposição por Inalação/análise , Laboratórios , Modelos Biológicos , Exposição Ocupacional/análise , Radiometria/métodos , Aerossóis/administração & dosagem , Aerossóis/farmacocinética , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Países Baixos , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Phys Med Biol ; 43(11): 3207-24, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9832012

RESUMO

A new method is described for the determination of x-ray quality dependent correction factors for free-air ionization chambers. The method is based on weighting correction factors for mono-energetic photons, which are calculated using the Monte Carlo method, with measured air kerma spectra. With this method, correction factors for electron loss, scatter inside the chamber and transmission through the diaphragm and front wall have been calculated for the NMi free-air chamber for medium-energy x-rays for a wide range of x-ray qualities in use at NMi. The newly obtained correction factors were compared with the values in use at present, which are based on interpolation of experimental data for a specific set of x-ray qualities. For x-ray qualities which are similar to this specific set, the agreement between the correction factors determined with the new method and those based on the experimental data is better than 0.1%, except for heavily filtered x-rays generated at 250 kV. For x-ray qualities dissimilar to the specific set, differences up to 0.4% exist, which can be explained by uncertainties in the interpolation procedure of the experimental data. Since the new method does not depend on experimental data for a specific set of x-ray qualities, the new method allows for a more flexible use of the free-air chamber as a primary standard for air kerma for any x-ray quality in the medium-energy x-ray range.


Assuntos
Radiometria/instrumentação , Ar , Fenômenos Biofísicos , Biofísica , Elétrons , Humanos , Método de Monte Carlo , Países Baixos , Fótons , Radiometria/normas , Radiometria/estatística & dados numéricos , Espalhamento de Radiação , Raios X
8.
Phys Med Biol ; 43(10): 2729-40, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9814513

RESUMO

The accuracy and traceability of the calibration of radiotherapy dosimeters is of great concern to those involved in the delivery of radiotherapy. It has been proposed that calibration should be carried out directly in terms of absorbed dose to water, instead of using the conventional and widely applied quantity of air kerma. In this study, the faithfulness in disseminating standards of both air kerma and absorbed dose to water were evaluated, through comparison of both types of calibration for three types of commonly used radiotherapy dosimeters at 60Co gamma beams at a few secondary and primary standard dosimetry laboratories (SSDLs and PSDLs). A supplementary aim was to demonstrate the impact which the change in the method of calibration would have on clinical dose measurements at the reference point. Within the estimated uncertainties, both the air kerma and absorbed dose to water calibration factors obtained at different laboratories were regarded as consistent. As might be expected, between the SSDLs traceable to the same PSDL the observed differences were smaller (less than 0.5%) than between PSDLs or SSDLs traceable to different PSDLs (up to 1.5%). This can mainly be attributed to the reported differences between the primary standards. The calibration factors obtained by the two methods differed by up to about 1.5% depending on the primary standards involved and on the parameters of calculation used for 60Co gamma radiation. It is concluded that this discrepancy should be settled before the new method of calibration at 60Co gamma beams in terms of absorbed dose to water is taken into routine use.


Assuntos
Calibragem , Raios gama , Radiometria/métodos , Ar , Radioisótopos de Cobalto , Radiação Ionizante , Radiometria/estatística & dados numéricos , Radioterapia/métodos , Padrões de Referência , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...