Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38838993

RESUMO

INTRODUCTION: Uveal melanoma (UM), while a rare malignancy, stands as the most prevalent intraocular malignancy in adults. Controversies persist regarding the dose dependency of local control (LC) through radiotherapy. This study seeks to elucidate the significance of the prescription dose by employing time-dose response models for UM patients receiving photon-based stereotactic radiosurgery (SRS). MATERIALS AND METHODS: Inclusion criteria comprised UM patients treated between 2005 and 2019. All patients underwent single-fraction SRS. Datapoints were separated into three dose groups, with Kaplan-Meier analysis performed on each group, from which time-dose response models for LC were created at 2, 4, and 7 years using maximum-likelihood fitted logistic models. RESULTS: Outcomes from 594 patients with 594 UM were used to create time-dose response models. The prescribed doses and the number of patients were as follows: 17-19 Gy (24 patients), 20 Gy (122 patients), 21 Gy (442 patients), and 22 Gy (6 patients). Averaged over all patients and doses, LC rates at 2, 4, and 7 years were 94.4%, 88.2%, and 69.0%, respectively. Time-dose response models for LC demonstrated a dose-dependent effect, showing 2-year LC rates of more than 90% with 20 Gy and 95% with 22 Gy. For four years and a LC of 90%, a dose of approximately 21 Gy was required. After seven years, the 21 Gy prescription dose is predicted to maintain a LC above 70%, sharply declining to less than 60% LC with 19 Gy and less than 40% with 18 Gy. CONCLUSION: In contrast to prior findings, the time-dose response models for UM undergoing photon-based SRS emphasize the critical role of the prescription dose in achieving lasting LC. The dose selection must be carefully balanced against toxicity risks, considering tumor geometry and individual patient characteristics to tailor treatments accordingly.

2.
J Appl Clin Med Phys ; : e14352, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696697

RESUMO

PURPOSE: To design a patient specific quality assurance (PSQA) process for the CyberKnife Synchrony system and quantify its dosimetric accuracy using a motion platform driven by patient tumor traces with rotation. METHODS: The CyberKnife Synchrony system was evaluated using a motion platform (MODUSQA) and a SRS MapCHECK phantom. The platform was programed to move in the superior-inferior (SI) direction based on tumor traces. The detector array housed by the StereoPhan was placed on the platform. Extra rotational angles in pitch (head down, 4.0° ± 0.15° or 1.2° ± 0.1°) were added to the moving phantom to examine robot capability of angle correction during delivery. A total of 15 Synchrony patients were performed SBRT PSQA on the moving phantom. All the results were benchmarked by the PSQA results based on static phantom. RESULTS: For smaller pitch angles, the mean gamma passing rates were 99.75% ± 0.87%, 98.63% ± 2.05%, and 93.11% ± 5.52%, for 3%/1 mm, 2%/1 mm, and 1%/1 mm, respectively. Large discrepancy in the passing rates was observed for different pitch angles due to limited angle correction by the robot. For larger pitch angles, the corresponding mean passing rates were dropped to 93.00% ± 10.91%, 88.05% ± 14.93%, and 80.38% ± 17.40%. When comparing with the static phantom, no significant statistic difference was observed for smaller pitch angles (p = 0.1 for 3%/1 mm), whereas a larger statistic difference was observed for larger pitch angles (p < 0.02 for all criteria). All the gamma passing rates were improved, if applying shift and rotation correction. CONCLUSIONS: The significance of this work is that it is the first study to benchmark PSQA for the CyberKnife Synchrony system using realistically moving phantoms with rotation. With reasonable delivery time, we found it may be feasible to perform PSQA for Synchrony patients with a realistic breathing pattern.

4.
Br J Radiol ; 97(1155): 660-667, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38401536

RESUMO

OBJECTIVES: To evaluate patient-specific quality assurance (PSQA) of 3 targets in a single delivery using a novel film-based phantom. METHODS: The phantom was designed to rotate freely as a sphere and could measure 3 targets with film in a single delivery. After identifying the coordinates of 3 targets in the skull, the rotation angles about the equator and meridian were computed for optimal phantom setup, ensuring the film plane intersected the 3 targets. The plans were delivered on the CyberKnife system using fiducial tracking. The irradiated films were scanned and processed. All films were analysed using 3 gamma criteria. RESULTS: Fifteen CyberKnife test plans with 3 different modalities were delivered on the phantom. Both automatic and marker-based registration methods were applied when registering the irradiated film and dose plane. Gamma analysis was performed using a 3%/1 mm, 2%/1 mm, and 1%/1 mm criteria with a 10% threshold. For the automatic registration method, the passing rates were 98.2% ± 1.9%, 94.2% ± 3.7%, and 80.9% ± 6.3%, respectively. For the marker-based registration approach, the passing rates were 96.4% ± 2.7%, 91.7% ± 4.3%, and 78.4% ± 6.2%, respectively. CONCLUSIONS: A novel spherical phantom was evaluated for the CyberKnife system and achieved acceptable PSQA passing rates using TG218 recommendations. The phantom can measure true-composite dose and offers high-resolution results for PSQA, making it a valuable device for robotic radiosurgery. ADVANCES IN KNOWLEDGE: This is the first study on PSQA of 3 targets concurrently on the CyberKnife system.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Procedimentos Cirúrgicos Robóticos , Humanos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos
5.
Int J Radiat Oncol Biol Phys ; 118(4): 931-943, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36682981

RESUMO

We sought to systematically review and summarize dosimetric factors associated with radiation-induced brachial plexopathy (RIBP) after stereotactic body radiation therapy (SBRT) or hypofractionated image guided radiation therapy (HIGRT). From published studies identified from searches of PubMed and Embase databases, data quantifying risks of RIBP after 1- to 10-fraction SBRT/HIGRT were extracted and summarized. Published studies have reported <10% risks of RIBP with maximum doses (Dmax) to the inferior aspect of the brachial plexus of 32 Gy in 5 fractions and 25 Gy in 3 fractions. For 10-fraction HIGRT, risks of RIBP appear to be low with Dmax < 40 to 50 Gy. For a given dose value, greater risks are anticipated with point volume-based metrics (ie, D0.03-0.035cc: minimum dose to hottest 0.03-0.035 cc) versus Dmax. With SBRT/HIGRT, there were insufficient published data to predict risks of RIBP relative to brachial plexus dose-volume exposure. Minimizing maximum doses and possibly volume exposure of the brachial plexus can reduce risks of RIBP after SBRT/HIGRT. Further study is needed to better understand the effect of volume exposure on the brachial plexus and whether there are location-specific susceptibilities along or within the brachial plexus structure.


Assuntos
Neuropatias do Plexo Braquial , Plexo Braquial , Lesões por Radiação , Radiocirurgia , Humanos , Radiocirurgia/efeitos adversos , Plexo Braquial/efeitos da radiação , Neuropatias do Plexo Braquial/etiologia , Neuropatias do Plexo Braquial/prevenção & controle , Radiometria
6.
Radiother Oncol ; 182: 109583, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36842665

RESUMO

INTRODUCTION: Radiation-induced brachial plexopathy (RIBP), resulting in symptomatic motor or sensory deficits of the upper extremity, is a risk after exposure of the brachial plexus to therapeutic doses of radiation. We sought to model dosimetric factors associated with risks of RIBP after stereotactic body radiotherapy (SBRT). METHODS: From a prior systematic review, 4 studies were identified that included individual patient data amenable to normal tissue complication probability (NTCP) modelling after SBRT for apical lung tumors. Two probit NTCP models were derived: one from 4 studies (including 221 patients with 229 targets and 18 events); and another from 3 studies (including 185 patients with 192 targets and 11 events) that similarly contoured the brachial plexus. RESULTS: NTCP models suggest ≈10% risks associated with brachial plexus maximum dose (Dmax) of ∼32-34 Gy in 3 fractions and ∼40-43 Gy in 5 fractions. RIBP risks increase with increasing brachial plexus Dmax. Compared to previously published data from conventionally-fractionated or moderately-hypofractionated radiotherapy for breast, lung and head and neck cancers (which tend to utilize radiation fields that circumferentially irradiate the brachial plexus), SBRT (characterized by steep dose gradients outside of the target volume) exhibits a much less steep dose-response with brachial plexus Dmax > 90-100 Gy in 2-Gy equivalents. CONCLUSIONS: A dose-response for risk of RIBP after SBRT is observed relative to brachial plexus Dmax. Comparisons to data from less conformal radiotherapy suggests potential dose-volume dependences of RIBP risks, though published data were not amenable to NTCP modelling of dose-volume measures associated with RIBP after SBRT.


Assuntos
Neuropatias do Plexo Braquial , Radiocirurgia , Humanos , Radiocirurgia/efeitos adversos , Dosagem Radioterapêutica , Estudos Retrospectivos , Neuropatias do Plexo Braquial/etiologia
8.
Cureus ; 14(10): e30676, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36439614

RESUMO

PURPOSE: Utilization of breathhold scans with live tracking has a long track record of good published outcomes for stereotactic body radiation therapy (SBRT) and is recommended by the manufacturer of the Synchrony tracking system. However, the popularity of four-dimensional computed tomography (4DCT) scans challenges the validity of the breathhold scan with live tracking technique. Although this study is not intended to prove the superiority of either method, we demonstrate the feasibility of using the breathhold scans with a phantom test and clinical examples. METHODS: A 4DCT of a perfect sphere was scanned at 20 breaths per minute and compared to a 4DCT of a small lung tumor in one patient and a 4DCT of a larger renal tumor in another patient, as well as to fiducial matching in a patient with pancreatic cancer. Normal exhale and normal inhale breathhold CT scans were performed for the pancreatic cancer patient, combined with Synchrony tracking on CyberKnife (Sunnyvale, CA: Accuray) for treatment. RESULTS: The 4DCT scan of the phantom exhibited considerable apparent deformation, which must be entirely due to imaging artifact since the perfect sphere in the phantom is known to be completely rigid. The 4DCT of the lung and renal tumors in patients had similar apparent deformation. Usually in patients, from 4DCT alone, it is difficult to determine how much was due to deformation and how much was due to artifact. Fiducial positions in the final normal exhale and normal inhale breathhold scans for Synchrony matched each other within 1mm for the pancreatic cancer patient. CONCLUSION: We demonstrated the feasibility of breathhold scans with Synchrony live tracking, as recommended by the manufacturer. More studies will be needed to determine whether this method is better than using a 4DCT.

10.
Technol Cancer Res Treat ; 20: 15330338211039135, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34632866

RESUMO

Purpose: Tumor treating fields (TTFields) is a novel antimitotic treatment that was first proven effective for glioblastoma multiforme, now with trials for several extracranial indications underway. Several studies focused on concurrent TTFields therapy with radiation in the same time period, but were not given simultaneously. This study evaluates the targeting accuracy of simultaneous radiation therapy while TTFields arrays are in place and powered on, ensuring that radiation does not interfere with TTFields and TTFields does not interfere with radiation. This is one of several options to enable TTFields to begin several weeks sooner, and opens potential for synergistic effects of combined therapy. Methods: TTFields arrays were attached to a warm saline water bath and salt was added until the TTFields generator reached the maximal 2000 mA peak-to-peak current. A ball cube phantom containing 2 orthogonal films surrounded by fiducials was placed in the water phantom, CT scanned, and a radiation treatment plan with 58 isocentric beams was created using a 3 cm circular collimator. Fiducial tracking was used to deliver radiation, the films were scanned, and end-to-end targeting error was measured with vendor-supplied software. In addition, radiation effects on electric fields generated by the TTFields system were assessed by examining logfiles generated from the field generator. Results: With TTFields arrays in place and powered on, the robotic radiosurgery system achieved a final targeting result of 0.47 mm, which was well within the submillimeter specification. No discernible effects on TTFields current output beyond 0.3% were observed in the logfiles when the radiation beam pulsed on and off. Conclusion: A robotic radiosurgery system was used to verify that radiation targeting was not adversely affected when the TTFields arrays were in place and the TTFields delivery device was powered on. In addition, this study verified that radiation delivered simultaneously with TTFields did not interfere with the generation of the electric fields.


Assuntos
Neoplasias Encefálicas/radioterapia , Glioblastoma/radioterapia , Radioterapia/métodos , Terapia Combinada/métodos , Marcadores Fiduciais , Cabeça , Humanos , Mitose/efeitos da radiação , Imagens de Fantasmas , Hipofracionamento da Dose de Radiação , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador , Robótica
11.
Med Phys ; 48(6): 2699-2700, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34235767
12.
Radiat Oncol ; 16(1): 98, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34098991

RESUMO

BACKGROUND: Brachial plexopathy is a potentially serious complication from stereotactic body radiation therapy (SBRT) that has not been widely studied. Therefore, we compared datasets from two different institutions and generated a brachial plexus dose-response model, to quantify what dose constraints would be needed to minimize the effect on normal tissue while still enabling potent therapy for the tumor. METHODS: Two published SBRT datasets were pooled and modeled from patients at Indiana University and the Richard L. Roudebush Veterans Administration Medical Center from 1998 to 2007, as well as the Karolinska Institute from 2008 to 2013. All patients in both studies were treated with SBRT for apically located lung tumors localized superior to the aortic arch. Toxicities were graded according to Common Terminology Criteria for Adverse Events, and a probit dose response model was created with maximum likelihood parameter fitting. RESULTS: This analysis includes a total of 89 brachial plexus maximum point dose (Dmax) values from both institutions. Among the 14 patients who developed brachial plexopathy, the most common complications were grade 2, comprising 7 patients. The median follow-up was 30 months (range 6.1-72.2) in the Karolinska dataset, and the Indiana dataset had a median of 13 months (range 1-71). Both studies had a median range of 3 fractions, but in the Indiana dataset, 9 patients were treated in 4 fractions, and the paper did not differentiate between the two, so our analysis is considered to be in 3-4 fractions, one of the main limitations. The probit model showed that the risk of brachial plexopathy with Dmax of 26 Gy in 3-4 fractions is 10%, and 50% with Dmax of 70 Gy in 3-4 fractions. CONCLUSIONS: This analysis is only a preliminary result because more details are needed as well as additional comprehensive datasets from a much broader cross-section of clinical practices. When more institutions join the QUANTEC and HyTEC methodology of reporting sufficient details to enable data pooling, our field will finally reach an improved understanding of human dose tolerance.


Assuntos
Plexo Braquial/efeitos da radiação , Tolerância a Radiação/efeitos da radiação , Radiocirurgia/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neuropatias do Plexo Braquial/etiologia , Neuropatias do Plexo Braquial/patologia , Fracionamento da Dose de Radiação , Relação Dose-Resposta à Radiação , Feminino , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Lesões por Radiação/etiologia , Lesões por Radiação/patologia , Medição de Risco
14.
Int J Radiat Oncol Biol Phys ; 110(2): 609-611, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33989578
16.
Int J Radiat Oncol Biol Phys ; 110(1): 217-226, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33864824

RESUMO

PURPOSE: Stereotactic body radiation therapy (SBRT) in the management of adrenal metastases is emerging as a well-tolerated, effective method of treatment for patients with limited metastatic disease. SBRT planning and treatment utilization are widely variable, and publications report heterogeneous radiation dose fractionation schemes and treatment outcomes. The objective of this analysis was to review the current literature on SBRT for adrenal metastases and to develop treatment guidelines and a model for tumor control probability of SBRT for adrenal metastases based on these publications. METHODS AND MATERIALS: A literature search of all studies on SBRT for adrenal metastases published from 2008 to 2017 was performed, and outcomes in these studies were reviewed. Local control (LC) rates were fit to a statistically significant Poisson model using maximum likelihood estimation techniques. RESULTS: One-year LC greater than 95% was achieved at an approximated biological equivalent dose with α/ß = 10 Gy of 116.4 Gy. CONCLUSIONS: While respecting normal tissue tolerances, tumor doses greater than or equal to a biological equivalent dose with α/ß = 10 Gy of 116.4 Gy are recommended to achieve high LC. Further studies following unified reporting standards are needed for more robust prediction.


Assuntos
Neoplasias das Glândulas Suprarrenais/radioterapia , Neoplasias das Glândulas Suprarrenais/secundário , Radiocirurgia/métodos , Neoplasias das Glândulas Suprarrenais/mortalidade , Neoplasias das Glândulas Suprarrenais/cirurgia , Humanos , Funções Verossimilhança , Modelos Biológicos , Modelos Teóricos , Órgãos em Risco/efeitos da radiação , Distribuição de Poisson , Probabilidade , Hipofracionamento da Dose de Radiação , Tolerância a Radiação , Eficiência Biológica Relativa , Resultado do Tratamento
18.
Int J Radiat Oncol Biol Phys ; 110(1): 147-159, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33583641

RESUMO

PURPOSE: Dose-volume data for injury to carotid artery and other major vessels in stereotactic body radiation therapy (SBRT)/SABR head and neck reirradiation were reviewed, modeled, and summarized. METHODS AND MATERIALS: A PubMed search of the English-language literature (stereotactic and carotid and radiation) in April 2018 found 238 major vessel maximum point doses in 6 articles that were pooled for logistic modeling. Two subsequent studies with dose-volume major vessel data were modeled separately for comparison. Attempts were made to separate carotid blowout syndrome from other bleeding events (BE) in the analysis, but we acknowledge that all except 1 data set has some element of BE interspersed. RESULTS: Prior radiation therapy (RT) dose was not uniformly reported per patient in the studies included, but a course on the order of conventionally fractionated 70 Gy was considered for the purposes of the analysis (with an approximately ≥6-month estimated interval between prior and subsequent treatment in most cases). Factors likely associated with reduced risk of BE include nonconsecutive daily treatment, lower extent of circumferential tumor involvement around the vessel, and no surgical manipulation before or after SBRT. CONCLUSIONS: Initial data pooling for reirradiation involving the carotid artery resulted in 3 preliminary models compared in this Hypofractionated Treatment Effects in the Clinic (HyTEC) report. More recent experiences with alternating fractionation schedules and additional risk-reduction strategies are also presented. Complications data for the most critical structures such as spinal cord and carotid artery are so limited that they cannot be viewed as strong conclusions of probability of risk, but rather, as a general guideline for consideration. There is a great need for better reporting standards as noted in the High Dose per Fraction, Hypofractionated Treatment Effects in the Clinic introductory paper.


Assuntos
Artérias Carótidas/efeitos da radiação , Doenças das Artérias Carótidas/etiologia , Hemorragia/etiologia , Tolerância a Radiação , Radiocirurgia/efeitos adversos , Reirradiação/efeitos adversos , Artérias Carótidas/diagnóstico por imagem , Lesões das Artérias Carótidas/etiologia , Relação Dose-Resposta à Radiação , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Modelos Logísticos , Modelos Biológicos , Modelos Teóricos , Hipofracionamento da Dose de Radiação , Lesões por Radiação/complicações , Medula Espinal/efeitos da radiação
19.
Int J Radiat Oncol Biol Phys ; 110(1): 53-67, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33390244

RESUMO

PURPOSE: As part of the American Association of Physicists in Medicine Working Group on Stereotactic Body Radiotherapy, tumor control probability (TCP) after stereotactic radiosurgery (SRS) and fractionated stereotactic radiosurgery (fSRS) for brain metastases was modeled based on pooled dosimetric and clinical data from published English-language literature. METHODS AND MATERIALS: PubMed-indexed studies published between January 1995 and September 2017 were used to evaluate dosimetric and clinical predictors of TCP after SRS or fSRS for brain metastases. Eligible studies had ≥10 patients and included detailed dose-fractionation data with corresponding ≥1-year local control (LC) data, typically evaluated as a >20% increase in diameter of the targeted lesion using the pre-SRS diameter as a reference. RESULTS: Of 2951 potentially eligible manuscripts, 56 included sufficient dose-volume data for analyses. Accepting that necrosis and pseudoprogression can complicate the assessment of LC, for tumors ≤20 mm, single-fraction doses of 18 and 24 Gy corresponded with >85% and 95% 1-year LC rates, respectively. For tumors 21 to 30 mm, an 18 Gy single-fraction dose was associated with 75% LC. For tumors 31 to 40 mm, a 15 Gy single-fraction dose yielded ∼69% LC. For 3- to 5-fraction fSRS using doses in the range of 27 to 35 Gy, 80% 1-year LC has been achieved for tumors of 21 to 40 mm in diameter. CONCLUSIONS: TCP for SRS and fSRS are presented. For small lesions ≤20 mm, single doses of ≈18 Gy appear generally associated with excellent rates of LC; for melanoma, higher doses seem warranted. For larger lesions >20 mm, local control rates appear to be ≈ 70% to 75% with usual doses of 15 to 18 Gy, and in this setting, fSRS regimens should be considered. Greater consistency in reporting of dosimetric and LC data is needed to facilitate future pooled analyses. As systemic and biologic therapies evolve, updated analyses will be needed to further assess the necessity, efficacy, and toxicity of SRS and fSRS.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Radiocirurgia/métodos , Encéfalo/patologia , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/patologia , Progressão da Doença , Humanos , Melanoma/patologia , Melanoma/radioterapia , Melanoma/secundário , Modelos Biológicos , Modelos Teóricos , Necrose , Probabilidade , Hipofracionamento da Dose de Radiação , Radiocirurgia/instrumentação , Resultado do Tratamento , Carga Tumoral
20.
Int J Radiat Oncol Biol Phys ; 110(1): 112-123, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33516580

RESUMO

PURPOSE: We sought to investigate the tumor control probability (TCP) of spinal metastases treated with stereotactic body radiation therapy (SBRT) in 1 to 5 fractions. METHODS AND MATERIALS: PubMed-indexed articles from 1995 to 2018 were eligible for data extraction if they contained SBRT dosimetric details correlated with actuarial 2-year local tumor control rates. Logistic dose-response models of collected data were compared in terms of physical dose and 3-fraction equivalent dose. RESULTS: Data were extracted from 24 articles with 2619 spinal metastases. Physical dose TCP modeling of 2-year local tumor control from the single-fraction data were compared with data from 2 to 5 fractions, resulting in an estimated α/ß = 6 Gy, and this was used to pool data. Acknowledging the uncertainty intrinsic to the data extraction and modeling process, the 90% TCP corresponded to 20 Gy in 1 fraction, 28 Gy in 2 fractions, 33 Gy in 3 fractions, and (with extrapolation) 40 Gy in 5 fractions. The estimated TCP for common fractionation schemes was 82% at 18 Gy, 90% for 20 Gy, and 96% for 24 Gy in a single fraction, 82% for 24 Gy in 2 fractions, and 78% for 27 Gy in 3 fractions. CONCLUSIONS: Spinal SBRT with the most common fractionation schemes yields 2-year estimates of local control of 82% to 96%. Given the heterogeneity in the tumor control estimates extracted from the literature, with variability in reporting of dosimetry data and the definition of and statistical methods of reporting tumor control, care should be taken interpreting the resultant model-based estimates. Depending on the clinical intent, the improved TCP with higher dose regimens should be weighed against the potential risks for greater toxicity. We encourage future reports to provide full dosimetric data correlated with tumor local control to allow future efforts of modeling pooled data.


Assuntos
Radiocirurgia/métodos , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Dor do Câncer/radioterapia , Relação Dose-Resposta à Radiação , Humanos , Modelos Logísticos , Modelos Biológicos , Modelos Teóricos , Probabilidade , Hipofracionamento da Dose de Radiação , Radiocirurgia/normas , Dosagem Radioterapêutica , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/patologia , Resultado do Tratamento , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...