Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
Acad Radiol ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38971660

RESUMO

RATIONALE AND OBJECTIVES: We explored the feasibility of using total tumor apparent diffusion coefficient (ttADC) histogram parameters to predict high-risk cytogenetic abnormalities (HRCA) in patients with multiple myeloma (MM) and compared the performance of an image prediction model based on these parameters with that of a combined prediction model based on these parameters and clinical indicators. METHODS: We retrospectively analyzed the parameters of the ttADC histogram based on whole-body diffusion-weighted images(WB-DWI) and clinical indicators in 92 patients with MM. The patients were divided into HRCA and non-HRCA groups according to the results of the fluorescence in situ hybridization. Logistic regression analysis was used to construct the image prediction and combined prediction models. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was used to evaluate the performance of the models to identify HRCA. The DeLong test was used to compare the AUC differences of each prediction model. RESULTS: Logistic regression analysis results revealed that the ttADC histogram parameter, ttADC entropy < 7.959 (OR: 39.167; 95% confidence interval [CI]: 3.891-394.208; P < 0.05), was an independent risk factor for HRCA. The image prediction model consisted of ttADC entropy and ttADC SD. The combined prediction model included ttADC entropy along with patient clinical indicators such as biological sex and M protein percentage. The AUCs of the image prediction and combined prediction models were 0.739 and 0.811, respectively (P < .05). The image prediction model showed a sensitivity of 73.9% and a specificity of 68.1%. The combined prediction model showed 82.6% sensitivity and 72.5% specificity. CONCLUSIONS: Using ttADC histogram parameters based on WB-DWI images to predict HRCA in patients with MM is feasible, and combining ttADC parameters with clinical indicators can achieve better predictive performance.

2.
Acad Radiol ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38908920

RESUMO

RATIONALE AND OBJECTIVES: Mesenchymal stem cells (MSCs) have the potential to promote liver regeneration, but the process is unclear. This study aims to explore the therapeutic effects and dynamic processes of MSCs in liver regeneration through intravoxel incoherent motion (IVIM) imaging. ANIMAL MODEL: 70 adult Sprague-Dawley rats were randomly divided into either the control or MSC group (n = 35/group). All rats received a partial hepatectomy (PH) with the left lateral and middle lobes removed. Each group was divided into seven subgroups: pre-PH and 1, 2, 3, 5, 7, and 14 days post-PH (n = 5 rats/subgroup). Magnetic resonance imaging (MRI) was performed before obtaining pathological specimens at each time point on postoperative days 1, 2, 3, 5, 7, and 14. The MRI parameters for the pure diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF) were calculated. Correlation analysis was conducted for the biochemical markers (alanine transaminase [ALT], aspartate transaminase [AST], and total bilirubin [TBIL]), histopathological findings (hepatocyte size and Ki-67 proliferation index), liver volume (LV) and liver regeneration rate (LLR). RESULTS: Liver D, D* , and PF differed significantly between the control and MSC groups at all time points (all P < 0.05). After PH, the D increased, then decreased, and the D* and PF decreased, then increased in both groups. The hepatocyte Ki-67 proliferation index of the MSC group was lower on day 2 post-PH, but higher on days 3 and 5 post-PH than that of the control group. Starting from day 3 post-PH, both the LV and LLR in the MSC group were greater than those in the control group (all P < 0.05). Hepatocytes were larger in the MSC group than in the control group on days 2 and 7 post-PH. In the MSC group, the D, D* , and PF were correlated with the AST levels, Ki-67 index and hepatocyte size (|r|=0.35-0.71; P < 0.05). In the control group, the D and D* were correlated with ALT levels, AST levels, Ki-67 index, LLR, LV, and hepatocyte size (|r|=0.34-0.95; P < 0.05). CONCLUSION: Bone marrow MSC therapy can promote hepatocyte hypertrophy and prolong liver proliferation post-PH. IVIM parameters allow non-invasively evaluating the efficacy of MSCs in promoting LR.

3.
J Magn Reson Imaging ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38826142

RESUMO

BACKGROUND: The number of focal liver lesions (FLLs) detected by imaging has increased worldwide, highlighting the need to develop a robust, objective system for automatically detecting FLLs. PURPOSE: To assess the performance of the deep learning-based artificial intelligence (AI) software in identifying and measuring lesions on contrast-enhanced magnetic resonance imaging (MRI) images in patients with FLLs. STUDY TYPE: Retrospective. SUBJECTS: 395 patients with 1149 FLLs. FIELD STRENGTH/SEQUENCE: The 1.5 T and 3 T scanners, including T1-, T2-, diffusion-weighted imaging, in/out-phase imaging, and dynamic contrast-enhanced imaging. ASSESSMENT: The diagnostic performance of AI, radiologist, and their combination was compared. Using 20 mm as the cut-off value, the lesions were divided into two groups, and then divided into four subgroups: <10, 10-20, 20-40, and ≥40 mm, to evaluate the sensitivity of radiologists and AI in the detection of lesions of different sizes. We compared the pathologic sizes of 122 surgically resected lesions with measurements obtained using AI and those made by radiologists. STATISTICAL TESTS: McNemar test, Bland-Altman analyses, Friedman test, Pearson's chi-squared test, Fisher's exact test, Dice coefficient, and intraclass correlation coefficients. A P-value <0.05 was considered statistically significant. RESULTS: The average Dice coefficient of AI in segmentation of liver lesions was 0.62. The combination of AI and radiologist outperformed the radiologist alone, with a significantly higher detection rate (0.894 vs. 0.825) and sensitivity (0.883 vs. 0.806). The AI showed significantly sensitivity than radiologists in detecting all lesions <20 mm (0.848 vs. 0.788). Both AI and radiologists achieved excellent detection performance for lesions ≥20 mm (0.867 vs. 0.881, P = 0.671). A remarkable agreement existed in the average tumor sizes among the three measurements (P = 0.174). DATA CONCLUSION: AI software based on deep learning exhibited practical value in automatically identifying and measuring liver lesions. TECHNICAL EFFICACY: Stage 2.

4.
Eur J Radiol ; 176: 111501, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38788607

RESUMO

PURPOSE: To evaluate the value of inline quantitative analysis of ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a population-based arterial input function (P-AIF) compared with offline quantitative analysis with an individual AIF (I-AIF) and semi-quantitative analysis for diagnosing breast cancer. METHODS: This prospective study included 99 consecutive patients with 109 lesions (85 malignant and 24 benign). Model-based parameters (Ktrans, kep, and ve) and model-free parameters (washin and washout) were derived from CAIPIRINHA-Dixon-TWIST-VIBE (CDTV) DCE-MRI. Univariate analysis and multivariate logistic regression analysis with forward stepwise covariate selection were performed to identify significant variables. The AUC and F1 score were assessed for semi-quantitative and two quantitative analyses. RESULTS: kep from inline quantitative analysis with P-AIF for diagnosing breast cancer provided an AUC similar to kep from offline quantitative analysis with I-AIF (0.782 vs 0.779, p = 0.954), higher compared to washin from semi-quantitative analysis (0.782 vs 0.630, p = 0.034). Furthermore, the inline quantitative analysis with P-AIF achieved the larger F1 score (0.920) compared with offline quantitative analysis with I-AIF (0.780) and semi-quantitative analysis (0.480). There were no statistically significant differences for kep values between the two quantitative analysis schemes (p = 0.944). CONCLUSION: The inline quantitative analysis with P-AIF from CDTV in characterizing breast lesions could offer similar diagnostic accuracy to offline quantitative analysis with I-AIF, and higher diagnostic accuracy to semi-quantitative analysis.


Assuntos
Neoplasias da Mama , Meios de Contraste , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Adulto , Idoso , Interpretação de Imagem Assistida por Computador/métodos , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Aumento da Imagem/métodos , Algoritmos
5.
J Magn Reson Imaging ; 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38214459

RESUMO

BACKGROUND: Non-contrast-enhanced 1 H magnetic resonance imaging (MRI) with full lung coverage shows promise for assessment of regional lung ventilation but a comparison with direct ventilation measurement using 19 F MRI is lacking. PURPOSE: To compare ventilation parameters calculated using 3D phase-resolved functional lung (PREFUL) MRI with 19 F MRI. STUDY TYPE: Prospective. POPULATION: Fifteen patients with asthma, 14 patients with chronic obstructive lung disease, and 13 healthy volunteers. FIELD STRENGTH/SEQUENCE: A 3D gradient-echo pulse sequence with golden-angle increment and stack-of-stars encoding at 1.5 T. ASSESSMENT: All participants underwent 3D PREFUL MRI and 19 F MRI. For 3D PREFUL, static regional ventilation (RVent) and dynamic flow-volume cross-correlation metric (FVL-CM) were calculated. For both parameters, ventilation defect percentage (VDP) values and ventilation defect (VD) maps (including a combination of both parameters [VDPCombined ]) were determined. For 19 F MRI, images from eight consecutive breaths under volume-controlled inhalation of perfluoropropane were acquired. Time-to-fill (TTF) and wash-in (WI) parameters were extracted. For all 19 F parameters, a VD map was generated and the corresponding VDP values were calculated. STATISTICAL TESTS: For all parameters, the relationship between the two techniques was assessed using a Spearman correlation (r). Differences between VDP values were compared using Bland-Altman analysis. For regional comparison of VD maps, spatial overlap and Sørensen-Dice coefficients were computed. RESULTS: 3D PREFUL VDP values were significantly correlated to VDP measures by 19 F (r range: 0.59-0.70). For VDPRVent , no significant bias was observed with VDP of the third and fourth breath (bias range = -6.8:7.7%, P range = 0.25:0.30). For VDPFVL-CM , no significant bias was found with VDP values of fourth-eighth breaths (bias range = -2.0:12.5%, P range = 0.12:0.75). The overall spatial overlap of all VD maps increased with each breath, ranging from 61% to 81%, stabilizing at the fourth breath. DATA CONCLUSION: 3D PREFUL MRI parameters showed moderate to strong correlation with 19 F MRI. Depending on the 3D PREFUL VD map, the best regional agreement was found to 19 F VD maps of third-fifth breath. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

6.
BMC Med Imaging ; 24(1): 16, 2024 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-38200447

RESUMO

BACKGROUND: T1 mapping can potentially quantitatively assess the intrinsic properties of tumors. This study was conducted to explore the ability of T1 mapping in distinguishing cervical cancer type, grade, and stage and compare the diagnostic performance of T1 mapping with diffusion kurtosis imaging (DKI). METHODS: One hundred fifty-seven patients with pathologically confirmed cervical cancer were enrolled in this prospectively study. T1 mapping and DKI were performed. The native T1, difference between native and postcontrast T1 (T1diff), mean kurtosis (MK), mean diffusivity (MD), and apparent diffusion coefficient (ADC) were calculated. Cervical squamous cell carcinoma (CSCC) and adenocarcinoma (CAC), low- and high-grade carcinomas, and early- and advanced-stage groups were compared using area under the receiver operating characteristic (AUROC) curves. RESULTS: The native T1 and MK were higher, and the MD and ADC were lower for CSCC than for CAC (all p < 0.05). Compared with low-grade CSCC, high-grade CSCC had decreased T1diff, MD, ADC, and increased MK (p < 0.05). Compared with low-grade CAC, high-grade CAC had decreased T1diff and increased MK (p < 0.05). Native T1 was significantly higher in the advanced-stage group than in the early-stage group (p < 0.05). The AUROC curves of native T1, MK, ADC and MD were 0,772, 0.731, 0.715, and 0.627, respectively, for distinguishing CSCC from CAC. The AUROC values were 0.762 between high- and low-grade CSCC and 0.835 between high- and low-grade CAC, with T1diff and MK showing the best discriminative values, respectively. For distinguishing between advanced-stage and early-stage cervical cancer, only the AUROC of native T1 was statistically significant (AUROC = 0.651, p = 0.002). CONCLUSIONS: Compared with DKI-derived parameters, native T1 exhibits better efficacy for identifying cervical cancer subtype and stage, and T1diff exhibits comparable discriminative value for cervical cancer grade.


Assuntos
Adenocarcinoma , Carcinoma de Células Escamosas , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/diagnóstico por imagem , Carcinoma de Células Escamosas/diagnóstico por imagem , Imagem de Tensor de Difusão , Adenocarcinoma/diagnóstico por imagem , Biomarcadores
7.
Eur Radiol ; 34(1): 80-89, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37548691

RESUMO

OBJECTIVES: To investigate whether 3D phase-resolved functional lung (PREFUL)-MRI parameters are suitable to measure response to elexacaftor/tezacaftor/ivacaftor (ETI) therapy and their association with clinical outcomes in cystic fibrosis (CF) patients. METHODS: Twenty-three patients with CF (mean age: 21; age range: 14-46) underwent MRI examination at baseline and 8-16 weeks after initiation of ETI. Morphological and 3D PREFUL scans assessed pulmonary ventilation. Morphological images were evaluated using a semi-quantitative scoring system, and 3D PREFUL scans were evaluated by ventilation defect percentage (VDP) values derived from regional ventilation (RVent) and cross-correlation maps. Improved ventilation volume (IVV) normalized to body surface area (BSA) between baseline and post-treatment visit was computed. Forced expiratory volume in 1 second (FEV1) and mid-expiratory flow at 25% of forced vital capacity (MEF25), as well as lung clearance index (LCI), were assessed. Treatment effects were analyzed using paired Wilcoxon signed-rank tests. Treatment changes and post-treatment agreement between 3D PREFUL and clinical parameters were evaluated by Spearman's correlation. RESULTS: After ETI therapy, all 3D PREFUL ventilation markers (all p < 0.0056) improved significantly, except for the mean RVent parameter. The BSA normalized IVVRVent was significantly correlated to relative treatment changes of MEF25 and mucus plugging score (all |r| > 0.48, all p < 0.0219). In post-treatment analyses, 3D PREFUL VDP values significantly correlated with spirometry, LCI, MRI global, morphology, and perfusion scores (all |r| > 0.44, all p < 0.0348). CONCLUSIONS: 3D PREFUL MRI is a very promising tool to monitor CFTR modulator-induced regional dynamic ventilation changes in CF patients. CLINICAL RELEVANCE STATEMENT: 3D PREFUL MRI is sensitive to monitor CFTR modulator-induced regional ventilation changes in CF patients. Improved ventilation volume correlates with the relative change of mucus plugging, suggesting that reduced endobronchial mucus is predominantly responsible for regional ventilation improvement. KEY POINTS: • 3D PREFUL MRI-derived ventilation maps show significantly reduced ventilation defects in CF patients after ETI therapy. • Significant post-treatment correlations of 3D PREFUL ventilation measures especially with LCI, FEV1 %pred, and global MRI score suggest that 3D PREFUL MRI is sensitive to measure improved regional ventilation of the lung parenchyma due to reduced inflammation induced by ETI therapy in CF patients. • 3D PREFUL MRI-derived improved ventilation volume (IVV) correlated with MRI mucus plugging score changes suggesting that reduced endobronchial mucus is predominantly responsible for regional ventilation improvement 8-16 weeks after ETI therapy.


Assuntos
Aminofenóis , Benzodioxóis , Fibrose Cística , Indóis , Pirazóis , Piridinas , Pirrolidinas , Quinolonas , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Fibrose Cística/diagnóstico por imagem , Fibrose Cística/tratamento farmacológico , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/uso terapêutico , Pulmão/diagnóstico por imagem , Ventilação Pulmonar , Imageamento por Ressonância Magnética/métodos , Mutação
8.
Eur J Radiol ; 170: 111203, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38007855

RESUMO

PURPOSE: To evaluate and compare the diagnostic value of diffusion-related texture analysis parameters obtained from various magnetic resonance diffusion models as early predictors of the clinical response to chemotherapy in patients with colorectal liver metastases (CRLM). METHODS: Patients (n = 145) with CRLM were prospectively and consecutively enrolled and scanned using diffusion-weighted imaging (DWI)-magnetic resonance imaging (MRI)/intravoxel incoherent motion (IVIM)/diffusion kurtosis imaging (DKI) before (baseline) and two-three weeks after (follow-up) commencing chemotherapy. Therapy response was evaluated based on the Response Evaluation Criteria in Solid Tumors (RECIST, version 1.1). The histogram and texture parameters of each diffusion-related parametric map were analysed between the responding and non-responding groups, screened using LASSO, and fitted with binary logistic regression models. The diagnostic efficacy of each model in the early prediction of CRLM was analysed, and the corresponding receiver operating characteristic (ROC) curve was drawn. The area under the curve (AUC) and 95% confidence intervals (CI) were calculated. RESULTS: Of the 145 analysed patients, 69 were in the responding group and 76 were in the non-responding group. Among all models, the difference value based on the histogram and texture features of the DKI-derived parameters performed best for the early prediction of CRLM treatment efficacy. The AUC of the DKI model in the validation set reached 0.795 (95% CI 0.652-0.938). Among the IVIM-derived parameters, the difference model based on D and D* performed best, and the AUC in the validation set reached 0.737 (95% CI 0.586-0.889). Finally, in the DWI sequence, the model comprising baseline features performed the best, with an AUC of 0.699 (95% CI 0.537-0.86) in the validation set. CONCLUSIONS: Baseline DWI parameters and follow-up changes in IVIM and DKI parameters predicted the chemotherapeutic response in patients with CRLM. In addition, as very early predictors, DKI-derived parameters were more effective than DWI- and IVIM-related parameters, in which changes in D-parameters performed best.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Estudos Prospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Imageamento por Ressonância Magnética
9.
Placenta ; 145: 38-44, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38052124

RESUMO

INTRODUCTION: Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has been a major global health problem since December 2019. This work aimed to investigate whether pregnant women's mild and moderate SARS-CoV-2 infection was associated with microstructural and vascular changes in the placenta observable in vivo by Intravoxel Incoherent Motion (IVIM) at different gestational ages (GA). METHODS: This was a retrospective, nested case-control of pregnant women during the SARS-CoV-2 pandemic (COVID-19 group, n = 14) compared to pre-pandemic healthy controls (n = 19). MRI IVIM protocol at 1.5T was constituted of diffusion-weighted (DW) images with TR/TE = 3100/76 ms and 10 b-values (0,10,30,50,75,100,200,400,700,1000s/mm2). Differences between IVIM parameters D (diffusion), and f (fractional perfusion) quantified in the two groups were evaluated using the ANOVA test with Bonferroni correction and linear correlation between IVIM metrics and GA, COVID-19 duration, the delay time between a positive SARS-CoV-2 test and MRI examination (delay-time exam+) was studied by Pearson-test. RESULTS: D was significantly higher in the COVID-19 placentas compared to that of the age-matched healthy group (p < 0.04 in fetal and p < 0.007 in maternal site). No significant difference between f values was found in the two groups suggesting no-specific microstructural damage with no perfusion alteration (potentially quantified by f) in mild/moderate SARS-Cov-2 placentas. A significant negative correlation was found between D and GA in the COVID-19 placentas whereas no significant correlation was found in the control placentas reflecting a possible accelerated senescence process due to COVID-19. DISCUSSION: We report impaired microstructural placental development during pregnancy and the absence of perfusion-IVIM parameter changes that may indicate no perfusion changing through microvessels and microvilli in the placentas of pregnancies with mild/moderate SARS-Cov-2 after reaching negativity.


Assuntos
COVID-19 , Placenta , Humanos , Feminino , Gravidez , Placenta/diagnóstico por imagem , Placenta/irrigação sanguínea , SARS-CoV-2 , Estudos Retrospectivos , COVID-19/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Placentação
10.
NMR Biomed ; 37(1): e5045, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37852945

RESUMO

This study investigated the use of intravoxel incoherent motion imaging (IVIM) to compare skeletal muscle perfusion during and after high-intensity interval training (HIIT) and moderate-intensity continuous training (MICT) to determine the impact on fat oxidation outcomes. Twenty overweight volunteers were recruited for the study. Each participant received one HIIT intervention and one MICT intervention using a cycling ergometer. Participants underwent a magnetic resonance imaging scan before, immediately after, and 1 and 2 h after each intervention. The IVIM parameters (D, fD*) of the rectus femoris, vastus lateralis, and biceps femoris long head were obtained. Changes in IVIM parameters of these muscles after both exercise interventions were compared using a two-factor repeated measures analysis of variance. In the rectus femoris, the fD* increased immediately after exercise intervention (d = 0.69 × 10-3  mm2 /s, p < 0.0083) and 2 h after exercise intervention (d = 0.64 × 10-3  mm2 /s, p < 0.0083) compared with before exercise. The increase in the fD* in the HIIT group was greater than that in the MICT group (d = 0.32, p = 0.023). In the vastus lateralis, the fD* increased immediately after the exercise intervention (d = 0.53 × 10-3  mm2 /s, p < 0.001) and returned to the pre-exercise level 1 h after exercising. The increase in the fD* in the HIIT group was lower than that in the MICT group (d = -0.21, p = 0.015). For the biceps femoris long head, the fD* was not significantly different between the two exercise interventions before and after exercise. Furthermore, the fD* 60 min after the HIIT intervention correlated with maximal oxygen consumption (VO2max), whereas fD* immediately after the MICT intervention correlated with VO2max. In summary, IVIM parameters can be used to evaluate differences in muscle perfusion between HIIT and MICT, and show a correlation with VO2max.


Assuntos
Treinamento Intervalado de Alta Intensidade , Humanos , Treinamento Intervalado de Alta Intensidade/métodos , Coxa da Perna/diagnóstico por imagem , Exercício Físico/fisiologia , Músculo Esquelético/diagnóstico por imagem , Imageamento por Ressonância Magnética
11.
Front Med (Lausanne) ; 10: 1256925, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37822465

RESUMO

Purpose: This study aimed to evaluate the diagnostic performance of perfusion-weighted phase-resolved functional lung (PW-PREFUL) magnetic resonance imaging (MRI) in patients with chronic pulmonary embolism (CPE). Materials and methods: This study included 86 patients with suspected chronic thromboembolic pulmonary hypertension (CTEPH), who underwent PREFUL MRI and ventilation/perfusion (V/Q) single-photon emission computed tomography/computed tomography (SPECT/CT). PREFUL MRI was performed at 1.5 T using a balanced steady-state free precession sequence during free breathing. Color-coded PW images and quantitative parameters were obtained by postprocessing. Meanwhile, V/Q SPECT/CT imaging was performed as a reference standard. Hypoperfused areas in the lungs were scored for each lobe and segment using V/Q SPECT/CT images and PW-PREFUL MR images, respectively. Normalized perfusion (QN) and perfusion defect percentage (QDP) were calculated for all slices. For intra- and interobserver variability, the MRI images were analyzed 2 months after the first analysis by the same radiologist and another radiologist (11 years of lung MRI experience) blinded to the results of the first reader. Results: Of the 86 enrolled patients, 77 met the inclusion criteria (36 diagnosed with CPE using V/Q SPECT/CT and 41 diagnosed with non-CPE etiology). For the PW-PREFUL MRI, the sensitivity, specificity, accuracy, and positive and negative predictive values for the diagnosis of CPE were 97, 95, 96, 95, and 98% at the patient level; 91, 94, 93, 91, and 94% at the lobe level, and 85, 94, 92, 88, and 94% at the segment level, respectively. The detection of segmental and subsegmental hypoperfusion using PW-PREFUL MRI revealed a moderate agreement with V/Q SPECT/CT (κ = 0.65; 95% confidence interval: 0.61-0.68). The quantitative results indicated that the QN was lower in the CPE group than in the non-CPE group [median score (interquartile range, IQR) 6.3 (2.8-9.2) vs. 13.0 (8.8-16.7), p < 0.001], and the QDP was higher [median score (IQR) 33.8 (15.7-51.7) vs. 2.2 (1.4-2.9), p < 0.001]. Conclusion: PREFUL MRI could be an alternative test to detect CPE without requiring breath-hold, contrast agents, or ionizing radiation.

12.
PLoS One ; 18(8): e0288744, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37527251

RESUMO

PURPOSE: The purpose of this study is to evaluate the influences of gadolinium-based contrast agents, field-strength and different sequences on perfusion quantification in Phase-Resolved Functional Lung (PREFUL) MRI. MATERIALS AND METHODS: Four cohorts of different subjects were imaged to analyze influences on the quantified perfusion maps: 1) at baseline and after 2 weeks to obtain the reproducibility (26 COPD patients), 2) before and after the administration of gadobutrol (11 COPD, 2 PAH and 1 asthma), 3) at 1.5T and 3T (12 healthy, 4 CF), and 4) with different acquisition sequences spoiled gradient echo (SPGR) and balanced steady-state free precession (bSSFP) (11 COPD, 7 healthy). Wilcoxon-signed rank test, Bland-Altman plots, voxelwise Pearson correlations, normalized histogram analyses with skewness and kurtosis and two-sample Kolmogorov-Smirnov tests were performed. P value ≤ 0.05 was considered statistically significant. RESULTS: In all cohorts, linear correlations of the perfusion values were significant with correlation coefficients of at least 0.7 considering the entire lung (P<0.01). The reproducibility cohort revealed stable results with a similar distribution. In the gadolinium cohort, the quantified perfusion increased significantly (P<0.01), and no significant change was detected in the histogram analysis. In the field-strength cohort, no significant change of the quantified perfusion was shown, but a significant increase of skewness and kurtosis at 3T (P = 0.01). In the sequence cohort, the quantified perfusion decreased significantly in the bSSFP sequence (P<0.01) together with a significant decrease of skewness and kurtosis (P = 0.02). The field-strength and sequence cohorts had differing probability distribution in the two-sample Kolmogorov-Smirnov tests. CONCLUSION: We observed a high susceptibility of perfusion quantification to gadolinium, field-strength or MRI sequence leading to distortion and deviation of the perfusion values. Future multicenter studies should strictly adhere to the identical study protocols to generate comparable results.


Assuntos
Gadolínio , Doença Pulmonar Obstrutiva Crônica , Humanos , Reprodutibilidade dos Testes , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Perfusão
13.
Quant Imaging Med Surg ; 13(7): 4130-4146, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37456293

RESUMO

Background: Bone marrow fat increases when the bone volume decreases. The composition of the bone marrow microenvironment can also become altered. Assessments of bone marrow fat and bone marrow structural heterogeneity have the potential to predict abnormal bone mineral density (BMD) and osteoporosis. This study aimed to investigate the diagnostic performance of T2*-corrected Q-Dixon and reduced-field-of-view (FOV) diffusion kurtosis imaging (DKI) parameters in determining abnormal BMD and osteoporosis in postmenopausal women. Methods: In this prospective study, the individuals who were eligible for inclusion included postmenopausal women (over 50-year-old) with suspected osteoporosis based on experiencing low back pain. This mono-center study was conducted in tertiary care in China. All of the patients were recruited by using the consecutive sampling method. Subjects who underwent T2*-corrected Q-Dixon and reduced-FOV DKI sequences were enrolled. Fat fraction (FF), T2*, mean kurtosis (MK), and mean diffusivity (MD) values were measured on L1, L2, and L3 vertebral bodies. Quantitative computed tomography (QCT) examinations served as the reference standard. All of the subjects were divided into three groups: normal (BMD >120 mg/cm3), osteopenia (BMD 80-120 mg/cm3), and osteoporosis (BMD <80 mg/cm3). One-way analysis of variance, correlation coefficient analysis, and receiver operating characteristic curve analysis were performed. Results: Among all of the enrolled subjects, 52 were in the normal group, 51 were in the osteopenia group, and 52 were in the osteoporosis group. There were significant differences in FF, T2*, MK, and MD values between the three groups (P<0.001, P<0.001, P<0.001, and P=0.003, respectively). FF, T2*, and MK values exhibited significant negative correlations with BMD values (r=-0.739, P<0.001; r=-0,676, P<0.001; and r=-0.626, P<0.001, respectively). Excellent discriminatory capacity was observed in the Q-Dixon [area under the curve (AUC): 0.976, 95% confidence interval (CI): 0.955-0.997] differentiation between normal and abnormal BMD subjects. It was significantly better than the DKI (AUC: 0.812, 95% CI: 0.741-0.882) parameter combination (P<0.001), whereas the DKI model (AUC: 0.825, 95% CI: 0.739-0.910) performed comparably to the Q-Dixon model (AUC: 0.798, 95% CI: 0.710-0.886) for screening osteoporosis (P=0.57). Conclusions: FF and T2* values measured by using T2*-corrected Q-Dixon, as well as MK and MD values measured by using reduced-FOV DKI, may serve as potential imaging biomarkers in assessing abnormal BMD and osteoporosis in postmenopausal women.

14.
Eur Radiol ; 33(11): 8122-8131, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37278853

RESUMO

OBJECTIVE: To investigate the utility of ultrafast dynamic-contrast-enhanced (DCE) MRI in visualization and quantitative characterization of pregnancy-associated breast cancer (PABC) and its differentiation from background-parenchymal-enhancement (BPE) among lactating patients. MATERIALS AND METHODS: Twenty-nine lactating participants, including 10 PABC patients and 19 healthy controls, were scanned on 3-T MRI using a conventional DCE protocol interleaved with a golden-angle radial sparse parallel (GRASP) ultrafast sequence for the initial phase. The timing of the visualization of PABC lesions was compared to lactational BPE. Contrast-noise ratio (CNR) was compared between the ultrafast and conventional DCE sequences. The differences in each group's ultrafast-derived kinetic parameters including maximal slope (MS), time to enhancement (TTE), and area under the curve (AUC) were statistically examined using the Mann-Whitney test and receiver operator characteristic (ROC) curve analysis. RESULTS: On ultrafast MRI, breast cancer lesions enhanced earlier than BPE (p < 0.0001), enabling breast cancer visualization freed from lactation BPE. A higher CNR was found for ultrafast acquisitions vs. conventional DCE (p < 0.05). Significant differences in AUC, MS, and TTE values were found between the tumor and BPE (p < 0.05), with ROC-derived AUC of 0.86 ± 0.06, 0.82 ± 0.07, and 0.68 ± 0.08, respectively. The BPE grades of the lactating PABC patients were reduced as compared with the healthy lactating controls (p < 0.005). CONCLUSION: Ultrafast DCE MRI allows BPE-free visualization of lesions, improved tumor conspicuity, and kinetic quantification of breast cancer during lactation. Implementation of this method may assist in the utilization of breast MRI for lactating patients. CLINICAL RELEVANCE: The ultrafast sequence appears to be superior to conventional DCE MRI in the challenging evaluation of the lactating breast. Thus, supporting its possible utilization in the setting of high-risk screening during lactation and the diagnostic workup of PABC. KEY POINTS: • Differences in the enhancement slope of cancer relative to BPE allowed the optimal visualization of PABC lesions on mid-acquisitions of ultrafast DCE, in which the tumor enhanced prior to the background parenchyma. • The conspicuity of PABC lesions on top of the lactation-related BPE was increased using an ultrafast sequence as compared with conventional DCE MRI. • Ultrafast-derived maps provided further characterization and parametric contrast between PABC lesions and lactation-related BPE.


Assuntos
Neoplasias da Mama , Lactação , Feminino , Gravidez , Humanos , Neoplasias da Mama/patologia , Aumento da Imagem/métodos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
15.
Prostate ; 83(9): 871-878, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36959777

RESUMO

BACKGROUND: Multiparametric MRI (mpMRI) improves the detection of aggressive prostate cancer (PCa) subtypes. As cases of active surveillance (AS) increase and tumor progression triggers definitive treatment, we evaluated whether an AI-driven algorithm can detect clinically significant PCa (csPCa) in patients under AS. METHODS: Consecutive patients under AS who received mpMRI (PI-RADSv2.1 protocol) and subsequent MR-guided ultrasound fusion (targeted and extensive systematic) biopsy between 2017 and 2020 were retrospectively analyzed. Diagnostic performance of an automated clinically certified AI-driven algorithm was evaluated on both lesion and patient level regarding the detection of csPCa. RESULTS: Analysis of 56 patients resulted in 93 target lesions. Patient level sensitivity and specificity of the AI algorithm was 92.5%/31% for the detection of ISUP ≥ 1 and 96.4%/25% for the detection of ISUP ≥ 2, respectively. The only case of csPCa missed by the AI harbored only 1/47 Gleason 7a core (systematic biopsy; previous and subsequent biopsies rendered non-csPCa). CONCLUSIONS: AI-augmented lesion detection and PI-RADS scoring is a robust tool to detect progression to csPCa in patients under AS. Integration in the clinical workflow can serve as reassurance for the reader and streamline reporting, hence improve efficiency and diagnostic confidence.


Assuntos
Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Conduta Expectante , Biópsia Guiada por Imagem/métodos , Inteligência Artificial
16.
Eur Spine J ; 32(3): 986-993, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36738338

RESUMO

STUDY DESIGN: Analytical cross-sectional study. PURPOSE: To study the role of diffusion kurtosis imaging (DKI) in evaluating microstructural changes in patients with cervical spondylosis. OVERVIEW OF LITERATURE: Cervical spondylosis is a common progressive degenerative disorder of the spine. Conventional magnetic resonance imaging (MRI) can only detect the changes in the spinal cord once there are visual signal changes; hence, it underestimates the extent of the injury. Newer imaging techniques like Diffusion Tensor and Kurtosis Imaging can evaluate the microstructural changes in cervical spinal cord before the obvious signal changes appear. METHODS: Conventional MRI, diffusion tensor imaging (DTI), and DKI scans were performed for 90 cervical spondylosis patients on 1.5-T MR Siemens Magnetom aera after obtaining informed consent. Eight patients were excluded due to poor image quality. Fractional anisotropy (FA) colour maps and diffusion kurtosis (DK) maps corresponding to spinal cord cross sections at C2-C3 intervertebral disc level (control) and at the most stenotic levels were obtained. Modified Japanese Orthopaedic Association (mJOA) scoring was used for clinical assessment of the spinal cord function. The changes in DTI and DKI parameters and their correlation with mJOA scores were analysed by SPSS 23 software. RESULTS: In our study, mean FA and mean kurtosis (MK) values at the stenotic level (0.54, 1.02) were significantly lower than values at the non-stenotic segment (0.70, 1.27). The mean diffusivity (MD) value at the stenotic segment (1.25) was significantly higher than in the non-stenotic segment (1.09). We also observed a strong positive correlation between mJOA score and FA and MK values and a negative correlation between mJOA score and MD values, suggesting a correlation of FA, MK, and MD with the clinical severity of the disease. CONCLUSION: Addition of DTI and DKI sequences helps in early identification of the disease without any additional cost incurred by the patient.


Assuntos
Medula Cervical , Espondilose , Humanos , Imagem de Tensor de Difusão/métodos , Estudos Transversais , Medula Espinal , Constrição Patológica , Espondilose/diagnóstico por imagem , Espondilose/patologia , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/patologia
17.
Quant Imaging Med Surg ; 13(2): 735-746, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36819265

RESUMO

Background: Histogram analysis of the diffusion-weighted imaging (DWI) parameters is widely used to differentiate the breast lesions. However, histogram analysis of the diffusion-kurtosis imaging (DKI) parameters for the single-shot echo-planar imaging (ss-EPI) and readout-segmented echo planar imaging (rs-EPI) sequences has not been compared in breast cancer. Thus, this study is to investigate the diagnostic accuracy and reliability of the histogram parameters derived from the rs-EPI and ss-EPI sequences of DKI parameters in distinguishing between the benign and malignant breast lesions. Methods: This single-center, retrospective cohort study enrolled 205 consecutive patients with breast lesions (65 benign and 140 malignant). The patients underwent breast magnetic resonance imaging (MRI) with a 3T scanner using the rs-EPI and ss-EPI sequences with 4 b values (0, 50, 1,000, and 2,000 s/mm2). The regions of interest (ROIs) were manually delineated for all the lesion images from both the sequences, and the histogram parameters were extracted from the apparent diffusion coefficient (ADC) and apparent diffusional kurtosis (Kapp) maps. Statistical analysis was performed using the Kolmogorov-Smirnov test, the student's t-test, and the receiver operating characteristic (ROC) curves. Results: The mean, 25th, 50th, 75th, and 100th percentiles, skewness, and kurtosis values derived from apparent diffusion for non-Gaussian distribution (Dapp) and Kapp maps showed good or excellent intra-observer agreement (ICC: 0.695 to 0.863).The mean and the 25th, 50th, 75th, and 100th percentile values for Dapp were significantly lower and the mean and the 25th, 50th, 75th, and 100th percentile values for Kapp were significantly higher in the malignant breast lesions compared with those in the benign breast lesions for both the rs-EPI and ss-EPI sequences (all P<0.05). The majority of the histogram Kapp and Dapp parameters (except skewness and kurtosis) for the benign and malignant lesions showed significant differences between the ss-EPI and the rs-EPI sequences (P<0.05). ROC curve analysis showed that the AUC values for the 75th percentile of Kapp (0.854 for rs-EPI, 0.844 for ss-EPI) and the 25th percentile of Dapp (0.866 for rs-EPI, 0.858 for ss-EPI) were highest for both DKI sequences. The diagnostic performance of the rs-EPI sequence was better than the ss-EPI sequence for all the histogram parameters except the skewness value of Dapp. Conclusions: Histogram parameters from the rs-EPI sequence were more reliable and accurate in differentiating malignant and benign breast lesions than those from the ss-EPI sequence.

18.
Cancer Imaging ; 23(1): 6, 2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36647150

RESUMO

BACKGROUND: Deep-learning-based computer-aided diagnosis (DL-CAD) systems using MRI for prostate cancer (PCa) detection have demonstrated good performance. Nevertheless, DL-CAD systems are vulnerable to high heterogeneities in DWI, which can interfere with DL-CAD assessments and impair performance. This study aims to compare PCa detection of DL-CAD between zoomed-field-of-view echo-planar DWI (z-DWI) and full-field-of-view DWI (f-DWI) and find the risk factors affecting DL-CAD diagnostic efficiency. METHODS: This retrospective study enrolled 354 consecutive participants who underwent MRI including T2WI, f-DWI, and z-DWI because of clinically suspected PCa. A DL-CAD was used to compare the performance of f-DWI and z-DWI both on a patient level and lesion level. We used the area under the curve (AUC) of receiver operating characteristics analysis and alternative free-response receiver operating characteristics analysis to compare the performances of DL-CAD using f- DWI and z-DWI. The risk factors affecting the DL-CAD were analyzed using logistic regression analyses. P values less than 0.05 were considered statistically significant. RESULTS: DL-CAD with z-DWI had a significantly better overall accuracy than that with f-DWI both on patient level and lesion level (AUCpatient: 0.89 vs. 0.86; AUClesion: 0.86 vs. 0.76; P < .001). The contrast-to-noise ratio (CNR) of lesions in DWI was an independent risk factor of false positives (odds ratio [OR] = 1.12; P < .001). Rectal susceptibility artifacts, lesion diameter, and apparent diffusion coefficients (ADC) were independent risk factors of both false positives (ORrectal susceptibility artifact = 5.46; ORdiameter, = 1.12; ORADC = 0.998; all P < .001) and false negatives (ORrectal susceptibility artifact = 3.31; ORdiameter = 0.82; ORADC = 1.007; all P ≤ .03) of DL-CAD. CONCLUSIONS: Z-DWI has potential to improve the detection performance of a prostate MRI based DL-CAD. TRIAL REGISTRATION: ChiCTR, NO. ChiCTR2100041834 . Registered 7 January 2021.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos
19.
J Magn Reson Imaging ; 58(4): 1055-1064, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36651358

RESUMO

BACKGROUND: Demand for prostate MRI is increasing, but scan times remain long even in abbreviated biparametric MRIs (bpMRI). Deep learning can be leveraged to accelerate T2-weighted imaging (T2WI). PURPOSE: To compare conventional bpMRIs (CL-bpMRI) with bpMRIs including a deep learning-accelerated T2WI (DL-bpMRI) in diagnosing prostate cancer. STUDY TYPE: Retrospective. POPULATION: Eighty consecutive men, mean age 66 years (47-84) with suspected prostate cancer or prostate cancer on active surveillance who had a prostate MRI from December 28, 2020 to April 28, 2021 were included. Follow-up included prostate biopsy or stability of prostate-specific antigen (PSA) for 1 year. FIELD STRENGTH AND SEQUENCES: A 3 T MRI. Conventional axial and coronal T2 turbo spin echo (CL-T2), 3-fold deep learning-accelerated axial and coronal T2-weighted sequence (DL-T2), diffusion weighted imaging (DWI) with b = 50 sec/mm2 , 1000 sec/mm2 , calculated b = 1500 sec/mm2 . ASSESSMENT: CL-bpMRI and DL-bpMRI including the same conventional diffusion-weighted imaging (DWI) were presented to three radiologists (blinded to acquisition method) and to a deep learning computer-assisted detection algorithm (DL-CAD). The readers evaluated image quality using a 4-point Likert scale (1 = nondiagnostic, 4 = excellent) and graded lesions using Prostate Imaging Reporting and Data System (PI-RADS) v2.1. DL-CAD identified and assigned lesions of PI-RADS 3 or greater. STATISTICAL TESTS: Quality metrics were compared using Wilcoxon signed rank test, and area under the receiver operating characteristic curve (AUC) were compared using Delong's test. SIGNIFICANCE: P = 0.05. RESULTS: Eighty men were included (age: 66 ± 9 years; 17/80 clinically significant prostate cancer). Overall image quality results by the three readers (CL-T2, DL-T2) are reader 1: 3.72 ± 0.53, 3.89 ± 0.39 (P = 0.99); reader 2: 3.33 ± 0.82, 3.31 ± 0.74 (P = 0.49); reader 3: 3.67 ± 0.63, 3.51 ± 0.62. In the patient-based analysis, the reader results of AUC are (CL-bpMRI, DL-bpMRI): reader 1: 0.77, 0.78 (P = 0.98), reader 2: 0.65, 0.66 (P = 0.99), reader 3: 0.57, 0.60 (P = 0.52). Diagnostic statistics from DL-CAD (CL-bpMRI, DL-bpMRI) are sensitivity (0.71, 0.71, P = 1.00), specificity (0.59, 0.44, P = 0.05), positive predictive value (0.23, 0.24, P = 0.25), negative predictive value (0.88, 0.88, P = 0.48). CONCLUSION: Deep learning-accelerated T2-weighted imaging may potentially be used to decrease acquisition time for bpMRI. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Idoso , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
20.
Magn Reson Med ; 89(5): 2048-2061, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36576212

RESUMO

PURPOSE: The purpose of this study is to assess the intra- and interscan repeatability of free-breathing phase-resolved functional lung (PREFUL) MRI in stable pediatric cystic fibrosis (CF) lung disease in comparison to static breath-hold hyperpolarized 129-xenon MRI (Xe-MRI) and pulmonary function tests. METHODS: Free-breathing 1-hydrogen MRI and Xe-MRI were acquired from 15 stable pediatric CF patients and seven healthy age-matched participants on two visits, 1 month apart. Same-visit MRI scans were also performed on a subgroup of the CF patients. Following the PREFUL algorithm, regional ventilation (RVent) and regional flow volume loop cross-correlation maps were determined from the free-breathing data. Ventilation defect percentage (VDP) was determined from RVent maps (VDPRVent ), regional flow volume loop cross-correlation maps (VDPCC ), VDPRVent ∪ VDPCC , and multi-slice Xe-MRI. Repeatability was evaluated using Bland-Altman analysis, coefficient of repeatability (CR), and intraclass correlation. RESULTS: Minimal bias and no significant differences were reported for all PREFUL MRI and Xe-MRI VDP parameters between intra- and intervisits (all P > 0.05). Repeatability of VDPRVent , VDPCC , VDPRVent ∪ VDPCC , and multi-slice Xe-MRI were lower between the two-visit scans (CR = 14.81%, 15.36%, 16.19%, and 9.32%, respectively) in comparison to the same-day scans (CR = 3.38%, 2.90%, 1.90%, and 3.92%, respectively). pulmonary function tests showed high interscan repeatability relative to PREFUL MRI and Xe-MRI. CONCLUSION: PREFUL MRI, similar to Xe-MRI, showed high intravisit repeatability but moderate intervisit repeatability in CF, which may be due to inherent disease instability, even in stable patients. Thus, PREFUL MRI may be considered a suitable outcome measure for future treatment response studies.


Assuntos
Fibrose Cística , Humanos , Criança , Fibrose Cística/diagnóstico por imagem , Respiração , Pulmão/diagnóstico por imagem , Testes de Função Respiratória , Isótopos de Xenônio , Imageamento por Ressonância Magnética , Xenônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...