Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 25(6): 729-34, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21620649

RESUMO

BACKGROUND: The purpose of this study was to determine which proximal seal zone characteristics were predictive of early and late type Ia endoleak development after endovascular aortic aneurysm repair (EVAR) for infrarenal abdominal aortic aneurysmal disease. METHODS: We evaluated 146 patients who underwent EVAR between January 2006 and March 2007. In the cohort, high-resolution computed tomography images of 100 (68.5%) patients were available, which showed detailed measurement of proximal neck parameters, including diameter, length, calcification, thrombus, suprarenal and infrarenal angles, and reverse taper morphology. Postprocessing of digital data sets was performed to obtain centerline-of-flow measurements. Relevant medical records and follow-up computed tomography scans were reviewed. RESULTS: Mean age of the patients was 72.7 years, with 78% being male. Of these patients, 66% did not satisfy the instructions for use for the Zenith EVAR device, and 50% did not satisfy the instructions for use for the AneuRx device. Nine patients had intraoperative type Ia endoleaks. A 100% assisted primary technical success rate was achieved with the adjunctive use of angioplasty (n = 4), uncovered stent (n = 3), and extension cuff (n = 2) placement. There was a significant association between type Ia endoleak development and magnitude of the infrarenal angle (p < 0.01); however, other parameters were not significant. At follow-up (mean, 587 days), no patient had a type Ia endoleak, and there were no aneurysm-related deaths. CONCLUSIONS: Our data indicate that infrarenal angle is related to intraoperative type Ia endoleak occurrence, but other factors often thought to be indicative of adverse neck anatomy are not significant predictors. Moreover, all type Ia endoleaks in this cohort were successfully eliminated intraoperatively, and durability was confirmed on postoperative surveillance. These data demonstrate that challenging neck anatomy is associated with the need for intraoperative endovascular adjuncts, and that effective and durable aneurysm exclusion should still be expected.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Distribuição de Qui-Quadrado , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Modelos Logísticos , Masculino , Pennsylvania , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Ann Vasc Surg ; 25(2): 165-8, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20889298

RESUMO

BACKGROUND: Myointimal hyperplasia is a pathologic result of the body's natural inflammatory response to injury of the blood vessels and a leading cause of peripheral arterial bypass failure. Because immunosuppressive agents are known to abate inflammation, we hypothesized the superior outcome of lower extremity bypass in renal transplant recipients compared with the hemodialysis population. METHODS: The vascular surgery registry at a single tertiary care center was retrospectively reviewed to identify patients who underwent lower extremity bypass procedures. All patients with a history of renal transplantation were selected for analysis. A consecutive group of bypass patients with dialysis-dependent renal failure was selected as a control cohort. The primary endpoint was amputation-free survival. RESULTS: Vascular reconstruction for chronic peripheral vascular disease yielded an amputation-free survival rate of 82% at 1 year for the those in the control group as compared with only 22% in the those with a history of renal transplantation (p = 0.02), which corresponded exactly with primary patency at 1 year. Patients were operated on for severe claudication (n = 1), rest pain (n = 1), and tissue loss (n = 17). There was no difference between the groups with regard to indication for operation or comorbid conditions. CONCLUSIONS: These data suggest a deleterious effect of immunosuppression on outcome of lower extremity bypass procedures at the doses required to prevent allograft rejection. This finding, which has been scarcely reported, underscores the importance of peripheral vascular disease screening in the transplant population and early intervention when clinically indicated.


Assuntos
Arteriopatias Oclusivas/cirurgia , Imunossupressores/uso terapêutico , Claudicação Intermitente/cirurgia , Nefropatias/terapia , Transplante de Rim , Extremidade Inferior/irrigação sanguínea , Diálise Renal , Procedimentos Cirúrgicos Vasculares , Idoso , Amputação Cirúrgica , Arteriopatias Oclusivas/complicações , Arteriopatias Oclusivas/mortalidade , Arteriopatias Oclusivas/fisiopatologia , Estudos de Casos e Controles , Intervalo Livre de Doença , Humanos , Imunossupressores/efeitos adversos , Claudicação Intermitente/etiologia , Claudicação Intermitente/mortalidade , Claudicação Intermitente/fisiopatologia , Nefropatias/complicações , Nefropatias/mortalidade , Transplante de Rim/efeitos adversos , Transplante de Rim/mortalidade , Salvamento de Membro , Pessoa de Meia-Idade , Pennsylvania , Sistema de Registros , Diálise Renal/efeitos adversos , Diálise Renal/mortalidade , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Procedimentos Cirúrgicos Vasculares/efeitos adversos
3.
J Vasc Surg ; 52(5): 1346-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20655689

RESUMO

Type IA endoleaks associated with endovascular aortic aneurysm repair are typically treated with endovascular adjuncts. Technical failure results when such maneuvers are unsuccessful, and endograft removal may, unfortunately, become necessary. The novel management of a recalcitrant type IA endoleak using the artificial embolization device, Onyx (Micro Therapeutics Inc, Irvine, Calif) is presented for the case of a nonagenarian with prohibitive surgical risk after conventional techniques had failed.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Embolização Terapêutica/instrumentação , Endoleak/terapia , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Desenho de Equipamento , Feminino , Humanos , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...