Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930287

RESUMO

This work presents issues related to selected errors accompanying spatial measurements of surface roughness using contact profilometry. The influence of internal heat sources, such as engines or control electronics, on the thermal expansion of the drive responsible for the measurement probe's movement in the X-axis direction was investigated. In terms of starting measurements on a thermally unstable device, the synchronization error of individual profile paths was 16.1 µm. Based on thermographic studies, the time required for full thermal stabilization of this drive was determined to be 6-12 h from when the device was turned on. It was demonstrated that thermal stabilization of the profilometer significantly reduced positioning errors of the measurement probe on the X-axis. Thermal stabilization time should be determined individually for a specific device variant. This research also determined how changes in the center of gravity caused by the measurement probe's movement affected the overall rigidity of the profilometer structure and the leveling of the tested surface. Laser interferometry was used for this purpose. The determined vulnerability of the profilometer structure was 0.8 µm for a measurement section of 25 mm. Understanding the described relationships will reduce errors associated with conducting measurements and preparing equipment for tests. Additionally, it will enable the correct evaluation of surface geometry.

2.
Materials (Basel) ; 16(18)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37763511

RESUMO

The use of thermoplastic materials has had significant growth in recent years. However, with great mechanical requirements, thermoplastics have limitations to their use. To improve these restrictions, these materials are reinforced to obtain better properties. Polypropylene is one of the most versatile polymers and is used in almost all modern industries. Thus, the aim of this study is to create composite materials that offer performance for various industrial fields using carbon fiber fabric reinforcement, which is an inexpensive material widely used by the aerospace, automotive, and marine industries. The samples are produced by the over-injection molding of polypropylene. The investigation is focused on the impact of two critical control parameters in the injection molding process: temperature and pressure. Twelve experiments have therefore been considered, taking into account the combination of three factors: the presence or absence of carbon fiber fabric reinforcement, three levels of temperature (200 °C, 220 °C, and 240 °C), and two injection pressures (5000 kPa and 10,000 kPa). To evaluate the influence of these factors, three analyses were carried out: first, on the samples' shrinkage using a portable metrology-grade 3D laser scanner; second, on the internal defects using computed tomography (CT); and third, on the mechanical properties with tensile tests. From the results obtained, it is observed that the mold shrinkage fell slightly when PP samples were reinforced with carbon fiber, with both materials (PP and carbon-fiber-reinforced PP) having linear behavior with temperature. It is also noticed that polypropylene behaves as a crystalline material when processed at higher temperatures and pressures. From tests on the mechanical properties, it is concluded that the mean yield strength of PP-CF for injection temperatures of 220 °C and 240 °C represents an increase of 43% compared to the non-reinforced material.

3.
Materials (Basel) ; 16(15)2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37570052

RESUMO

The performance of a heat sink is significantly influenced by the type of cooling used: passive or active (forced), the shape of the heat sink, and the material from which it is made. This paper presents a review of the literature on the influence of geometry and surface parameters on effective heat transfer in heat sinks. The results of simulation studies for three different heat sink fin geometries and cooling types are presented. Furthermore, the influence of the surface texture of the heat sink fins on the heat transfer efficiency was determined. It was shown that the best performance in terms of geometries was that of a wave fin heat sink. When the surface texture was analyzed, it was found that an increase in the amplitude values of the texture decreases the heat dissipation efficiency in the case of active cooling, while for passive cooling, an increase in these parameters has a beneficial effect and increases the effective heat transfer to the surroundings. The cooling method was found to be the most important factor affecting heat dissipation efficiency. Forced airflow results in more efficient heat transfer from the heat sink fins to the surroundings.

4.
Materials (Basel) ; 16(15)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37570108

RESUMO

With the simultaneous increase in the number of endoprostheses being performed, advances in the field of biomaterials are becoming apparent-whereby the materials and technologies used to construct implants clearly improve the implants' quality and, ultimately, the life of the patient after surgery. The aim of this study was to modify the titanium alloy Ti6Al4V ELI used in the construction of hip joint endoprostheses. This is why the continuous development of biomaterials is so important. This paper presents the results of research for a new application of polymer poly(ethylene-alt-maleic anhydride) as a drug release layer, placed on the surface of a titanium alloy. The obtained layers were analyzed using Raman spectroscopy (spectra and maps), Fourier transform infrared spectroscopy (spectra and maps), contact angle measurements as well as scanning electron microscopy and energy dispersive spectroscopy imaging and topography analysis. The results confirmed that the polymer layer obtained on the plate surface after the alkali heat treatment process is much better-it binds much more polymer and thus the applied drug. In addition, a longer and more gradual release of the drug was observed for the alkali heat treatment modification than for H2O2 solution.

5.
Materials (Basel) ; 16(14)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37512235

RESUMO

The aim of this research was to analyze the effect of inorganic additives on the tribological properties of the high-density polyethylene (HDPE) matrix composite surface. Titanium (Ti) and hexagonal boron nitride (hBN) were added in different mass fractions. The samples were produced by pressing a pre-prepared mixture of granules. The composite samples with the following mass fractions of additives were fabricated: 5% hBN, 10% hBN, 28% Ti-2% hBN, 23% Ti-7% hBN, and 20% Ti-10% hBN. An even distribution of individual additives' concentrations was confirmed. Observations of morphology, surface topography, hardness, and tribological measurements were conducted using reciprocating motion tests with the "pin-on-flat" and rotational tests with the "pin-on-disc" configuration. Subsequently, microscopic observations and measurements of the wear track profile were carried out. Additionally, geometry parameters of the contacting elastic body were calculated for various counter-samples. It was found that the Shore D hardness of samples containing Ti and hBN increased with the Ti content, while the coefficient of friction (COF) value decreased. The addition of hBN alone did not significantly affect the hardness, regardless of the ratio, while the COF increased with the increasing hBN content. The COF value doubled with the addition of 10% hBN (COF = 0.22), whereas the addition of 90% Ti-10% hBN resulted in a decrease in the COF value, to COF = 0.83. The highest hardness value was obtained for the sample containing 28% Ti-2% hBN (66.5), while the lowest was for the sample containing 10% hBN (63.2). The wear track analysis, including its height and width caused by deformation, was detected using a focal differentiation microscope and scanning electron microscopy. Additionally, EDS maps were generated to determine the wear characteristics of the composite.

6.
Materials (Basel) ; 16(12)2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37374480

RESUMO

Mechanical processing of cortical bone tissue is one of the most common surgical procedures. A critical issue accompanying this processing is the condition of the surface layer, which can stimulate tissue growth and serve as a drug carrier. A comparison of the surface condition before and after orthogonal and abrasive processing was conducted to validate the influence of bone tissue's processing mechanism and orthotropic properties on the surface topography. A cutting tool with a defined geometry and a custom-made abrasive tool was used. The bone samples were cut in three directions, depending on the orientation of the osteons. The cutting forces, acoustic emission, and surface topography were measured. The level of isotropy and the topography of the grooves showed statistical differences relative to the anisotropy directions. After orthogonal processing, the surface topography parameter Ra was determined from 1.38 ± 0.17 µm to 2.82 ± 0.32. In the case of abrasive processing, no correlation was found between the orientation of osteons and topographical properties. The average groove density for abrasive machining was below 1004 ± 0.7, and for orthogonal, it was above 1156 ± 58. Due to the positive properties of the developed bone surface, it is advisable to cut in the transverse direction and parallel to the axis of the osteons.

7.
Materials (Basel) ; 16(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36837339

RESUMO

Osteoporosis is the most common metabolic disease of the skeletal system and is characterized by impaired bone strength. This translates into an increased risk of low-energy fractures, which means fractures caused by disproportionate force. This disease is quite insidious, its presence is usually detected only at an advanced stage, where treatment with pharmaceuticals does not produce sufficient results. It is obligatory to replace the weakened bone with an implant. For this reason, it is necessary to look at the possibilities of surface modification used in tissue engineering, which, in combination with the drugs for osteoporosis, i.e., bisphosphonates, may constitute a new and effective method for preventing the deterioration of the osteoporotic state. To achieve this purpose, titanium implants coated with magnesium or zinc zeolite were prepared. Both the sorption and release profiles differed depending on the type of ion in the zeolite structure. The successful release of risedronate from the materials at a low level was proven. It can be concluded that the proposed solution will allow the preparation of endoprostheses for patients with bone diseases such as osteoporosis.

8.
Materials (Basel) ; 16(3)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36770206

RESUMO

In the article, the new concept of plasma-sprayed coatings for the cylinder liner was presented. The new type of powder containing WC-CrC-Ni with a 5 and 10 wt. % addition of nano-YSZ powder was plasma-sprayed on aluminum 2017 alloy samples. The selection of optimal plasma-spraying parameters was made taking into account the thickness, porosity, and hardness of the coatings. For the coatings obtained according to the developed parameters, the analysis of their microstructure, chemical, and phase composition was performed. At the next stage, the friction coefficient of the developed coatings was tested and compared with the properties of a classic cast-iron cylinder liner. The obtained results suggest that the developed type of coating might be used for cylinder liner applications after a deeper friction analysis.

9.
Materials (Basel) ; 14(24)2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34947204

RESUMO

The paper presents a method for checking the geometry of stamped car body parts using a 3D optical measurement system. The analysis focuses on the first forming operation due to the deformation and material flow associated with stall thresholds. An essential element of the analysis is determining the actual gap occurring between the forming surfaces based on the die and punch geometry used in the first stamping operation. The geometry of car body elements at individual production stages was analyzed using an optical laser scanner. The control carried out in this way allowed one to correctly position the tools (punch and die), thus introducing the correction of technological parameters, having a fundamental influence on the specific features of the final product. This type of approach has not been used before to calibrate the technological line and setting of shaping tools. The influence of the manufactured product geometry in intermediate operations on the final geometry features was not investigated.

10.
Materials (Basel) ; 14(22)2021 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-34832444

RESUMO

The fundamental issue in surface metrology is to provide methods that can allow the establishment of correlations between measured topographies and performance or processes, or that can discriminate confidently topographies that are processed or performed differently. This article presents a set of topographies from two-staged processed steel rings, measured with a 3D contact profilometer. Data were captured individually from four different regions, namely the top, bottom, inner, and outer surfaces. The rings were manufactured by drop forging and hot rolling. Final surface texture was achieved by mass finishing with spherical ceramic media or cut wire. In this study, we compared four different multiscale methods: sliding bandpass filtering, three geometric length- and area-scale analyses, and the multiscale curvature tensor approach. In the first method, ISO standard parameters were evaluated as a function of the central wavelength and bandwidth for measured textures. In the second and third method, complexity and relative length and area were utilized. In the last, multiscale curvature tensor statistics were calculated for a range of scales from the original sampling interval to its forty-five times multiplication. These characterization parameters were then utilized to determine how confident we can discriminate (through F-test) topographies between regions of the same specimen and between topographies resulting from processing with various technological parameters. Characterization methods that focus on the geometrical properties of topographic features allowed for discrimination at the finest scales only. Bandpass filtration and basic height parameters Sa and Sq proved to confidently discriminate against all factors at all three considered bandwidths.

11.
Materials (Basel) ; 13(10)2020 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-32438690

RESUMO

This paper presents the influence of thermal phenomena on areal measurements of surface topography using contact profilometers. The research concerned measurements under controlled and variable environmental conditions. The influence of internal heat sources from profilometer drives and their electronic components was analyzed. For this purpose, a thermal chamber was designed and built. Its task was to maintain and control environmental conditions and, at the same time, separate the profilometer from external disturbances. Heat sources and temperature values for elements and systems were determined. It further enabled for the calculation of the displacements in axes as a function of temperature. The largest displacement in the probe due to internal heat sources for the considered cases occurred in the X-axis direction. Its value reached 16.2 µm. However, the displacement in the probe in the Z-axis direction had the greatest impact on the measured surface topography. These displacements for a thermally unstable profilometer reached 7.9 µm in Z, causing results even 90% greater than in the case of a device without such problems. The time after which a proper topography measurement can be started was also determined basing on obtained data. This time for tested profilometers was between 6 and 12 h. It was found that performing thermal stabilization of the profilometer significantly reduced surface irregularity errors. The stabilization time should be determined individually for a specific type of device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...