Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Nephrol Ther ; 17(6): 428-433, 2021 Oct.
Artigo em Francês | MEDLINE | ID: mdl-34034971

RESUMO

Since 2010, a lot of cases of amoxicillin induced crystal nephropathy have been reported to the French pharmacovigilance centers partly due to the high doses recommended by infectious disease guidelines. Typical clinical presentation and exclusion of others toxics or immuno-allergic causes are mandatory to assess the diagnostic. Amoxicillin crystals are rarely found or searched and renal biopsy is not frequently performed due to technical reasons and prompt renal recovery after antibiotics withdrawal. Monitoring of residual plasma concentration is rarely used in clinical practice for diagnostic or prognostic interest. We present 9 consecutive cases of acute kidney injury suspected to be due to amoxicillin crystals with residuals plasma levels to disclose a predictive threshold of tubulopathy. All patients had a high residual rate at diagnosis but we cannot find a threshold that would allow to adapt the antibiotic dose, enhance hydratation and alkalinizide urine to increase the medication solubility and limit renal toxicity.


Assuntos
Injúria Renal Aguda , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Amoxicilina/efeitos adversos , Antibacterianos/efeitos adversos , Humanos , Rim
3.
J Pediatric Infect Dis Soc ; 9(6): 686-694, 2020 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-32068854

RESUMO

BACKGROUND: Congenital cytomegalovirus (CMV) remains an important healthcare burden, resulting from primary or secondary infection in pregnant women. Exposure to young children's saliva is a major risk factor, as prevalence of CMV shedding can reach 34%. METHODS: This cross-sectional, multicenter, nationwide study was conducted in randomly selected day care centers (DCCs), and complemented with a survey among parents and DCCs. All children aged >3 months were eligible. The study measured the CMV shedding prevalence in children's saliva and described CMV genotypes epidemiology. The risk factors for CMV shedding and high viral load were evaluated using multivariable models. RESULTS: A total of 93 DCCs participated. Among the 1770 enrolled children with evaluable samples, the CMV shedding prevalence was 40% (713/1770, 95% confidence interval, 34.6-46.1), independently associated with children aged between 12 and 18 months, history of CMV infection in ≥1 parents, a mid-level income. Prevalence increased with DCC staff workload and attending children number. Viral load was ≥5 log-copies CMV/mL in 48% (342/713). Risk factors for higher viral load included children aged between 12 and 18 months, and still being breastfed. The most frequent genotype combinations were gB1-gN4c-gH2 (6.9%), gB1-gN2-gH2 (6.3%), gB4a-gN3a-gH1 (6.3%), and gB1-gN3b-gH2 (5,7%). CMV awareness was low in parents: their serological status was unknown by 72% of mothers and 82% of fathers. Only 41% knew something about CMV. CONCLUSIONS: CMV shedding was independently associated with risk factors related to the children, family and DCC. Some of these risk factors may influence prevention strategies, including through an improved information provided to parents. CLINICAL TRIALS REGISTRATION: NCT01704222.


Assuntos
Infecções por Citomegalovirus , Citomegalovirus , Criança , Pré-Escolar , Estudos Transversais , Infecções por Citomegalovirus/epidemiologia , Hospital Dia , Feminino , Humanos , Lactente , Pais , Gravidez , Fatores de Risco , Eliminação de Partículas Virais
4.
Ann Biol Clin (Paris) ; 77(2): 219-224, 2019 04 01.
Artigo em Francês | MEDLINE | ID: mdl-30998200

RESUMO

Toxicological screening is a specific approach to analytical toxicology that uses analytical tools such as GC-MS, LC-UV (diode array) or LC-MS. Toxicological screening allows the detection and simultaneous identification of a large number of compounds. The results may be based on the use of one or more techniques. As part of the accreditation process for medical biology examinations according to standard NF EN ISO 15189, the group from SFTA and SFBC recommends an approach to accredit toxicological screening. Indeed, the complexity of the accreditation of this analysis comes in particular from the high number of compounds that can be detected. Validation parameters are discussed in the specific context of toxicological screening by considering two distinct approaches: the simple identification of compounds, or the identification and estimation of a range of concentration related to clinical outcomes.


Assuntos
Acreditação , Química Clínica/normas , Testes Diagnósticos de Rotina/normas , Toxicologia/normas , Química Clínica/métodos , Química Clínica/organização & administração , Cromatografia Líquida , Testes Diagnósticos de Rotina/métodos , Contaminação de Equipamentos , Cromatografia Gasosa-Espectrometria de Massas , Ensaios de Triagem em Larga Escala/métodos , Ensaios de Triagem em Larga Escala/normas , Humanos , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Controle de Qualidade , Sociedades Médicas/organização & administração , Sociedades Médicas/normas , Espectrometria de Massas em Tandem , Toxicologia/métodos , Toxicologia/organização & administração , Estudos de Validação como Assunto
5.
Waste Manag ; 39: 226-35, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25776743

RESUMO

The Waste Electrical and Electronic Equipment (WEEE) or e-waste recycling sector has grown considerably in the last fifteen years due to the ever shorter life cycles of consumables and an increasingly restrictive policy context. Cathode Ray Tubes (CRTs) from used television and computer screens represent one of the main sources of e-waste. CRTs contain toxic materials such as lead, cadmium, barium, and fluorescent powders which can be released if recycling of CRTs is not appropriate. Exposure to these harmful substances was assessed in nine workshops where CRT screens are treated. Particulate exposure levels were measured using a gravimetric method and metals were analysed by plasma emission spectrometry. The maximum levels of worker exposure were 8.8mg/m(3), 1504.3µg/m(3), 434.9µg/m(3), 576.3µg/m(3) and 2894.3µg/m(3) respectively for inhalable dust, barium, cadmium, lead and yttrium. The maximum levels of airborne pollutants in static samples were 39.0mg/m(3), 848.2µg/m(3), 698.4µg/m(3), 549.3µg/m(3) and 3437.9µg/m(3) for inhalable dust, barium, cadmium, lead and yttrium. The most harmful operations were identified, and preventive measures for reducing the chemical risk associated with screen recycling were proposed. Workplace measurements were used to define recommendations for reducing the chemical risks in CRT screens recycling facilities and for promoting the design and development of "clean and safe" processes in emerging recycling channels.


Assuntos
Resíduo Eletrônico/análise , Poluentes Ambientais/análise , Substâncias Perigosas/análise , Exposição Ocupacional , Tubo de Raio Catódico , Monitoramento Ambiental , França , Humanos , Reciclagem
6.
Waste Manag ; 34(7): 1257-63, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24768515

RESUMO

The fluorescent lamp recycling sector is growing considerably in Europe due to increasingly strict regulations aimed at inciting the consumption of low energy light bulbs and their end-of-life management. Chemical risks were assessed in fluorescent lamp recycling facilities by field measurement surveys in France, highlighting that occupational exposure and pollutant levels in the working environment were correlated with the main recycling steps and processes. The mean levels of worker exposure are 4.4 mg/m(3), 15.4 µg/m(3), 14.0 µg/m(3), 247.6 µg/m(3), respectively, for total inhalable dust, mercury, lead and yttrium. The mean levels of airborne pollutants are 3.1mg/m(3), 9.0 µg/m(3), 9.0 µg/m(3), 219.2 µg/m(3), respectively, for total inhalable dust, mercury, lead and yttrium. The ranges are very wide. Surface samples from employees' skin and granulometric analysis were also carried out. The overview shows that all the stages and processes involved in lamp recycling are concerned by the risk of hazardous substances penetrating into the bodies of employees, although exposure of the latter varies depending on the processes and tasks they perform. The conclusion of this study strongly recommends the development of a new generation of processes in parallel with more information sharing and regulatory measures.


Assuntos
Poluentes Ambientais/análise , Utensílios Domésticos , Exposição Ocupacional , Reciclagem , Poeira/análise , Monitoramento Ambiental , França , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...