Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Farmaco ; 58(10): 1039-44, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14505736

RESUMO

The electrophoretic mobilities of alprenolol have been determined in a mixed solvent background electrolyte system containing sodium acetate (40 mM)+acetic acid (40 mM) as buffering agent and different volume fractions of water, methanol and ethanol using capillary electrophoresis. The mobility of alprenolol has been used to test the prediction capability of a model trained by previously reported mobility data of five beta-blocker drugs at the same electrophoretic conditions. The average percentage mean deviations (APMD) between experimental and predicted values were used as an accuracy criterion. The APMD (+/-SD) obtained for alprenolol data in binary/ternary solvent electrolyte system employing the mobility values in mono-solvent buffers was 4.37 (+/-3.50)% and the corresponding value for an ab initio prediction method was 7.65 (+/-4.30)%.


Assuntos
Antagonistas Adrenérgicos beta/análise , Alprenolol/análise , Alprenolol/química , Soluções Tampão , Eletrólitos/química , Eletroforese Capilar/métodos , Etanol , Metanol , Valor Preditivo dos Testes , Solventes/química , Água
2.
J Chromatogr A ; 994(1-2): 191-8, 2003 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-12779229

RESUMO

The electrophoretic mobilities of two beta-blocker drugs, i.e., labetalol and atenolol, have been determined in a mixed solvent background electrolyte system containing sodium acetate+acetic acid as buffering agent and different volume fractions of water, methanol and ethanol using capillary electrophoresis. The produced data and three other sets collected from a recent work are employed to study the accuracy and prediction capability of a mathematical model to calculate the electrophoretic mobility with respect to the volume fractions of the solvents in the mixture. The results show that the proposed model is able to correlate/predict the mobility within an acceptable error range and it is possible to use the model in industry to achieve the optimum solvent composition for the buffer where using a ternary solvent system is required. The average percentage deviations (APDs) obtained for correlated and predicted data points are 0.71-2.48 and 1.72-4.39%, respectively. The accuracy of the proposed model is compared with that of a mixture response surface method and the results show that the proposed model is superior from both correlation and prediction points of view. The possibility of calculation of the mobility of chemically related drugs in water-methanol-ethanol mixtures using the proposed model is also shown and the produced prediction APD is approximately 8%.


Assuntos
Eletroforese Capilar/métodos , Preparações Farmacêuticas/isolamento & purificação , Solventes
3.
Analyst ; 127(9): 1188-92, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12375841

RESUMO

The electrophoretic mobilities of three beta-blocker drugs, practolol, timolol and propranolol, have been measured in electrolyte systems with mixed binary and ternary water-methanol-ethanol solvents with acetic acid/sodium acetate as buffer using capillary electrophoresis. The highest mobilities for the analytes studied have been observed in pure aqueous, the lowest values in ethanolic buffers. The measured electrophoretic mobilities have been used to evaluate the accuracy of a mathematical model based on a mixture response surface method that expresses the mobility as a function of the solvent composition. Mean percentage error (MPE) has been computed considering experimental and calculated mobilities as an accuracy criterion. The obtained MPE for practolol, timolol and propranolol in the binary mixtures are between 0.9 and 2.6%, in the ternary water-methanol-ethanol solvent system the MPE was about 2.7%. The MPE values resulting from the proposed equation lie within the experimental relative standard deviation values and can be considered as an acceptable error.


Assuntos
Antagonistas Adrenérgicos beta/análise , Eletroforese Capilar/métodos , Modelos Químicos , Practolol/análise , Propranolol/análise , Solventes , Timolol/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...