Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Clin EEG Neurosci ; 54(3): 316-326, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-34658289

RESUMO

Background: Functional (un-)coupling (task-related change of functional connectivity) between different sites of the brain is a mechanism of general importance for cognitive processes. In Alzheimer's disease (AD), prior research identified diminished cortical connectivity as a hallmark of the disease. However, little is known about the relation between the amount of functional (un-)coupling and cognitive performance and decline in AD. Method: Cognitive performance (based on CERAD-Plus scores) and electroencephalogram (EEG)-based functional (un-)coupling measures (connectivity changes from rest to a Face-Name-Encoding task) were assessed in 135 AD patients (age: M = 73.8 years; SD = 9.0). Of these, 68 patients (M = 73.9 years; SD = 8.9) participated in a follow-up assessment of their cognitive performance 1.5 years later. Results: The amounts of functional (un-)coupling in left anterior-posterior and homotopic interhemispheric connections in beta1-band were related to cognitive performance at baseline (ß = .340; p < .001; ß = .274; P = .001, respectively). For both markers, a higher amount of functional coupling was associated with better cognitive performance. Both markers also were significant predictors for cognitive decline. However, while patients with greater functional coupling in left anterior-posterior connections declined less in cognitive performance (ß = .329; P = .035) those with greater functional coupling in interhemispheric connections declined more (ß = -.402; P = .010). Conclusion: These findings suggest an important role of functional coupling mechanisms in left anterior-posterior and interhemispheric connections in AD. Especially the complex relationship with cognitive decline in AD patients might be an interesting aspect for future studies.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Humanos , Idoso , Imageamento por Ressonância Magnética , Eletroencefalografia/métodos , Encéfalo , Progressão da Doença
2.
Artigo em Inglês | MEDLINE | ID: mdl-30582941

RESUMO

BACKGROUND: So far, no cost-efficient, widely-used biomarkers have been established to facilitate the objectivization of Alzheimer's disease (AD) diagnosis and monitoring. Research suggests that event-related potentials (ERPs) reflect neurodegenerative processes in AD and might qualify as neurophysiological AD markers. OBJECTIVES: First, to examine which ERP component correlates the most with AD severity, as measured by the Mini-Mental State Examination (MMSE). Then, to analyze the temporal change of this component as AD progresses. METHODS: Sixty-three subjects (31 with possible, 32 with probable AD diagnosis) were recruited as part of the cohort study Prospective Dementia Registry Austria (PRODEM). For a maximum of 18 months patients revisited every 6 months for follow-up assessments. ERPs were elicited using an auditory oddball paradigm. P300 and N200 latency was determined with regard to target as well as difference wave ERPs, whereas P50 amplitude was measured from standard stimuli waveforms. RESULTS: P300 latency exhibited the strongest association with AD severity (e.g., r = -0.512, p < 0.01 at Pz for target stimuli in probable AD subjects). Further, there were significant Pearson correlations for N200 latency (e.g., r = -0.407, p = 0.026 at Cz for difference waves in probable AD subjects). P50 amplitude, as measured by different detection methods and at various scalp sites, did not significantly correlate with disease severity - neither in probable AD, possible AD, nor in both subgroups of patients combined. ERP markers for the group of possible AD patients did not show any significant correlations with MMSE scores. Post-hoc pairwise comparisons between baseline and 18-months follow-up assessment revealed significant P300 latency differences (e.g., p < 0.001 at Cz for difference waves in probable AD subjects). However, there were no significant correlations between the change rates of P300 latency and MMSE score. CONCLUSIONS: P300 and N200 latency significantly correlated with disease severity in probable AD, whereas P50 amplitude did not. P300 latency, which showed the highest correlation coefficients with MMSE, significantly increased over the course of the 18 months study period in probable AD patients. The magnitude of the observed prolongation is in line with other longitudinal AD studies and substantially higher than in normal ageing, as reported in previous trials (no healthy controls were included in our study).


Assuntos
Doença de Alzheimer/fisiopatologia , Encéfalo/fisiopatologia , Potenciais Evocados , Idoso , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/genética , Apolipoproteínas E/genética , Progressão da Doença , Eletroencefalografia , Potenciais Evocados/fisiologia , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Testes de Estado Mental e Demência , Estudos Prospectivos , Índice de Gravidade de Doença
3.
J Neural Transm (Vienna) ; 123(3): 297-316, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26411482

RESUMO

We analyzed the relation of several synchrony markers in the electroencephalogram (EEG) and Alzheimer's disease (AD) severity as measured by Mini-Mental State Examination (MMSE) scores. The study sample consisted of 79 subjects diagnosed with probable AD. All subjects were participants in the PRODEM-Austria study. Following a homogeneous protocol, the EEG was recorded both in resting state and during a cognitive task. We employed quadratic least squares regression to describe the relation between MMSE and the EEG markers. Factor analysis was used for estimating a potentially lower number of unobserved synchrony factors. These common factors were then related to MMSE scores as well. Most markers displayed an initial increase of EEG synchrony with MMSE scores from 26 to 21 or 20, and a decrease below. This effect was most prominent during the cognitive task and may be owed to cerebral compensatory mechanisms. Factor analysis provided interesting insights in the synchrony structures and the first common factors were related to MMSE scores with coefficients of determination up to 0.433. We conclude that several of the proposed EEG markers are related to AD severity for the overall sample with a wide dispersion for individual subjects. Part of these fluctuations may be owed to fluctuations and day-to-day variability associated with MMSE measurements. Our study provides a systematic analysis of EEG synchrony based on a large and homogeneous sample. The results indicate that the individual markers capture different aspects of EEG synchrony and may reflect cerebral compensatory mechanisms in the early stages of AD.


Assuntos
Doença de Alzheimer/fisiopatologia , Encéfalo/fisiopatologia , Sincronização Cortical/fisiologia , Idoso , Idoso de 80 Anos ou mais , Eletroencefalografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 427-430, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28268364

RESUMO

The standard polysomnographic method for detecting periodic limb movements in sleep (PLMS) includes measuring the electromyography (EMG) signals from electrodes at the left and right tibialis anterior muscles. This procedure has disadvantages as the cabling affects the patients quality of sleep and the electrodes tend to come off during the night, deteriorating data quality. We used contactless monitoring of body movements by a 3D time-of-flight camera mounted above the bed. Changes in the 3D silhouette indicate motion. Contactless detection of PLMS has several substantial advantages over the EMG and provides more complete and more specific diagnostic data: (1) Motor events caused by other leg muscles than tibialis anterior muscles are fully captured by the 3D method, but missed by EMG. (2) 3D does not react to tonic muscle contractions, where such contractions cause strong deflections in EMG which are annotated as limb movements by most PSG apparatus. Another aspect turned out to be of high practical relevance: Deflections in EMG traces are frequently caused by poor electrode contacts, potentially causing false movement annotations. This can lead to substantial overestimation of the automatically computed PLM index. Contactless sensing completely avoids such problems.


Assuntos
Extremidades/fisiologia , Movimento/fisiologia , Sono/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas Biossensoriais , Eletrodos , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiologia , Adulto Jovem
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 6078-6081, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269639

RESUMO

Alzheimer's Disease (AD) can take different courses: some patients remain relatively stable while others decline rapidly within a given period of time. Losing more than 3 Mini-Mental State Examination (MMSE) points in one year is classified as rapid cognitive decline (RCD). This study used neuropsychological test scores and quantitative EEG (QEEG) markers obtained at a baseline examination to identify if an AD patient will be suffering from RCD. Data from 68 AD patients of the multi-centric cohort study PRODEM-Austria were applied. 15 of the patients were classified into the RCD group. RCD versus non-RCD support vector machine (SVM) classifiers using QEEG markers as predictors obtained 72.1% and 77.9% accuracy ratings based on leave-one-out validation. Adding neuropsychological test scores of Boston Naming Test improved the classifier to 80.9% accuracy, 80% sensitivity, and 81.1% specificity. These results indicate that QEEG markers together with neuropsychological test scores can be used as RCD predictors.


Assuntos
Doença de Alzheimer/diagnóstico , Biomarcadores/análise , Disfunção Cognitiva/diagnóstico , Eletroencefalografia , Testes Neuropsicológicos , Estudos de Coortes , Humanos , Sensibilidade e Especificidade
6.
Clin Neurophysiol ; 126(3): 505-13, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25091343

RESUMO

OBJECTIVE: To investigate which single quantitative electro-encephalographic (QEEG) marker or which combination of markers correlates best with Alzheimer's disease (AD) severity as measured by the Mini-Mental State Examination (MMSE). METHODS: We compared quantitative EEG markers for slowing (relative band powers), synchrony (coherence, canonical correlation, Granger causality) and complexity (auto-mutual information, Shannon/Tsallis entropy) in 118 AD patients from the multi-centric study PRODEM Austria. Signal spectra were determined using an indirect spectral estimator. Analyses were adjusted for age, sex, duration of dementia, and level of education. RESULTS: For the whole group (39 possible, 79 probable AD cases) MMSE scores explained 33% of the variations in relative theta power during face encoding, and 31% of auto-mutual information in resting state with eyes closed. MMSE scores explained also 25% of the overall QEEG factor. This factor was thus subordinate to individual markers. In probable AD, QEEG coefficients of determination were always higher than in the whole group, where MMSE scores explained 51% of the variations in relative theta power. CONCLUSIONS: Selected QEEG markers show strong associations with AD severity. Both cognitive and resting state should be used for QEEG assessments. SIGNIFICANCE: Our data indicate theta power measured during face-name encoding to be most closely related to AD severity.


Assuntos
Doença de Alzheimer/diagnóstico , Encéfalo/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/fisiopatologia , Áustria , Biomarcadores , Eletroencefalografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Estudos Prospectivos , Sistema de Registros , Índice de Gravidade de Doença
7.
Int J Psychophysiol ; 93(3): 390-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24933410

RESUMO

BACKGROUND: Quantitative electroencephalogram (qEEG) recorded during cognitive tasks has been shown to differentiate between patients with Alzheimer's disease (AD) and healthy individuals. However, the association between various qEEG markers recorded during mnestic paradigms and clinical measures of AD has not been studied in detail. OBJECTIVE: To evaluate if 'cognitive' qEEG is a useful diagnostic option, particularly if memory paradigms are used as cognitive stimulators. METHODS: This study is part of the Prospective Registry on Dementia in Austria (PRODEM), a multicenter dementia research project. A cohort of 79 probable AD patients was included in a cross-sectional analysis. qEEG recordings performed in resting states were compared with recordings during cognitively active states. Cognition was evoked with a face-name paradigm and a paired-associate word list task, respectively. Relative band powers, coherence and auto-mutual information were computed as functions of MMSE scores for the memory paradigms and during rest. Analyses were adjusted for the co-variables age, sex, duration of dementia and educational level. RESULTS: MMSE scores explained 36-51% of the variances of qEEG-markers. Face-name encoding with eyes open was superior to resting state with eyes closed in relative theta and beta1 power as well as coherence, whereas relative alpha power and auto-mutual information yielded more significant results during resting state with eyes closed. The face-name task yielded stronger correlations with MMSE scores than the verbal memory task. CONCLUSION: qEEG alterations recorded during mnestic activity, particularly face-name encoding showed the highest association with the MMSE and may serve as a clinically valuable marker for disease severity.


Assuntos
Doença de Alzheimer/complicações , Transtornos Cognitivos/etiologia , Eletroencefalografia , Potenciais Evocados Visuais/fisiologia , Descanso/fisiologia , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/genética , Apolipoproteínas E/genética , Aprendizagem por Associação/fisiologia , Ondas Encefálicas/fisiologia , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Masculino , Entrevista Psiquiátrica Padronizada , Pessoa de Meia-Idade , Testes Neuropsicológicos , Estimulação Luminosa
8.
Artigo em Inglês | MEDLINE | ID: mdl-23366366

RESUMO

We analyzed three different approaches to automatic real-time monitoring of the time course of individual alpha frequencies (IAFs) of the human electro-encephalograms. Fast Fourier transform and wavelet transform were compared to classical automated cycle counting in the time domain. With fast Fourier and wavelet transform, test results with healthy adult subjects, demented and psychiatric patients revealed typical short-term variations of the instantaneous IAFs of about ± 2 Hz. When cycles were counted in the time domain, however, variations of only ± 1 Hz were recorded. Thus, IAF measurement in the time domain appears to be particularly suitable. We also observed long-term IAF trends that typically amounted to about ± 0.5 to ± 1.0 Hz. Therefore, our hypothesis is that the IAF does not constitute an intra-individual constant but varies with time and cognitive state. Our fully automatic real-time signal-processing procedure includes pre-processing for artifact detection and for localization of segments with synchronized alpha oscillations where the IAF should preferably be measured.


Assuntos
Algoritmos , Ritmo alfa/fisiologia , Diagnóstico por Computador/métodos , Eletroencefalografia/métodos , Processamento de Sinais Assistido por Computador , Sistemas Computacionais , Análise de Fourier , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Ondaletas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...