Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chim Acta ; 486: 265-268, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30118674

RESUMO

BACKGROUND: Therapeutic drug monitoring is used for aminoglycosides and vancomycin, and has been proposed for ß-lactam antibiotics. Clinical blood samples in the ICU are often obtained via an existing vascular catheter rather than fresh needle phlebotomy. If antibiotics had previously been infused through a vascular catheter then used for blood sampling, carryover of antibiotic from the infusion to the sample might result in misleading assessments of target attainment. To address this concern we conducted a series of in vitro measurements of carryover for three commonly used antibiotics. METHODS: We infused piperacillin-tazobactam, meropenem, and cefepime at pharmacologic concentrations through commonly used vascular catheters at our hospital and flushed the catheters. We then aspirated warmed citrated bovine blood through each catheter and measured antibiotic concentrations in each aspirate. RESULTS: Carryover was below the limits of detection for piperacillin-tazobactam, meropenem, and vancomycin. Cefepime carryover, in contrast, was not negligible and needs to be investigated more fully. CONCLUSION: Carryover from prior infusions does not appear to jeopardize measurements of piperacillin-tazobactam, meropenem, or vancomycin in commonly used vascular catheters at our institution. Caution in interpreting samples obtained for cefepime measurements appears advised until more data is available.


Assuntos
Cateteres de Demora , Cefepima/sangue , Cateteres Venosos Centrais , Meropeném/sangue , Piperacilina/sangue , Vancomicina/sangue , Animais , Bovinos , Cromatografia Líquida de Alta Pressão
2.
Clin Chim Acta ; 482: 60-64, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29596815

RESUMO

BACKGROUND: Sepsis is a common diagnosis in critical care with inpatient mortality rates up to 50%. Sepsis care is organized around source control, antibiotics, and supportive care. Drug disposition is deranged by changes in volume of distribution and regional blood flow, as well as multiple organ failure. Thus, assuring that each patient with sepsis attains pharmacokinetic targets is challenging. There is currently no commercially available FDA-approved assay to measure piperacillin-tazobactam, very commonly used as a beta-lactam/beta-lactamase inhibitor combination antibiotic in the intensive care unit (ICU). METHODS: Samples were prepared by ultrafiltration of plasma collected in lithium heparin Vacutainers. Separation was achieved by gradient elution on a C-18 column followed by UV detection at 214 nm. The method is validated in residual blood samples allowing investigators to exploit a waste product to develop insight into beta-lactam pharmacokinetics in the ICU. RESULTS: Accuracy and precision were within the 25% CLIA error standard for other antibiotic assays. Free piperacillin concentrations were also in good agreement with total piperacillin concentrations measured in the same plasma by an assay in clinical use outside the United States. CONCLUSION: We describe a method for measuring piperacillin and tazobactam that meets clinical validation standards. Quick turnaround time and excellent accuracy on a low-cost platform make this method more than adequate for use as a routine therapeutic drug monitoring tool.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/métodos , Ácido Penicilânico/análogos & derivados , Piperacilina/análise , Coleta de Amostras Sanguíneas , Cromatografia de Fase Reversa , Monitoramento de Medicamentos/economia , Humanos , Ácido Penicilânico/análise , Ácido Penicilânico/farmacocinética , Piperacilina/farmacocinética , Combinação Piperacilina e Tazobactam , Sepse/tratamento farmacológico , Tazobactam
3.
J Biomech ; 69: 26-33, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29395231

RESUMO

An implantable artificial kidney using a hemofilter constructed from an array of silicon membranes to provide ultrafiltration requires a suitable blood flow path to ensure stable operation in vivo. Two types of flow paths distributing blood to the array of membranes were evaluated: parallel and serpentine. Computational fluid dynamics (CFD) simulations were used to guide the development of the blood flow paths. Pressure data from animal tests were used to obtain pulsatile flow conditions imposed in the transient simulations. A key consideration for stable operation in vivo is limiting platelet stress accumulation to avoid platelet activation and thrombus formation. Platelet stress exposure was evaluated by CFD particle tracking methods through the devices to provide distributions of platelet stress accumulation. The distributions of stress accumulation over the duration of a platelet lifetime for each device revealed that stress accumulation for the serpentine flow path exceeded levels expected to cause platelet activation while the accumulated stress for the parallel flow path was below expected activation levels.


Assuntos
Plaquetas/fisiologia , Simulação por Computador , Rins Artificiais , Estresse Fisiológico , Trombose/fisiopatologia , Animais , Hidrodinâmica , Modelos Cardiovasculares , Ativação Plaquetária , Pressão , Fluxo Pulsátil
4.
Am J Physiol Renal Physiol ; 314(6): F1108-F1116, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28424207

RESUMO

One of the many unresolved questions regarding the permeability of the glomerular filtration barrier is the reason behind the marked difference in permeability between albumin and polysaccharide probe molecules such as Ficoll and dextran of the same molecular size. Although the differences in permeability have been mainly attributed to charge effects, we have previously shown that this would require a highly charged filtration barrier, having a charge density that is ~10 times more than that on the albumin molecule. In this article, the classic two-pore model was extended by introducing size distributions on the solute molecules, making them conformationally flexible. Experimental sieving data for Ficoll from the rat glomerulus and from precision-made silicon nanopore membranes were analyzed using the model. For the rat glomerulus a small-pore radius of 36.2 Å and a geometric standard deviation (gSD) for the Ficoll size-distribution of 1.16 were obtained. For the nanopore membranes, a gSD of 1.24 and a small-pore radius of 43 Å were found. Interestingly, a variation of only ~16% in the size of the polysaccharide molecule is sufficient to explain the difference in permeability between albumin and Ficoll. Also, in line with previous data, the effects of applying a size distribution on the solute molecule are only evident when the molecular size is close to the pore size. Surely there is at least some variation in the pore radii, and, likely, the gSD obtained in the current study is an overestimation of the "true" variation in the size of the Ficoll molecule.


Assuntos
Ficoll/metabolismo , Taxa de Filtração Glomerular , Glomérulos Renais/metabolismo , Modelos Biológicos , Albuminas/química , Albuminas/metabolismo , Animais , Transporte Biológico , Simulação por Computador , Ficoll/química , Barreira de Filtração Glomerular/metabolismo , Membranas Artificiais , Peso Molecular , Nanoporos , Permeabilidade , Porosidade , Ratos , Silicones/química
5.
ASAIO J ; 64(2): 211-217, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28857774

RESUMO

A major challenge in developing blood-contacting medical devices is mitigating thrombogenicity of an intravascular device. Thrombi may interfere with device function or embolize from the device to occlude distant vascular beds with catastrophic consequences. Chemical interactions between plasma proteins and bioengineered surface occur at the nanometer scale; however, continuum models of blood predict local shear stresses that lead to platelet activation or aggregation and thrombosis. Here, an iterative approach to blood flow path design incorporating in silico, in vitro, and in vivo experiments predicted the occurrence and location of thrombi in an implantable hemofilter. Low wall shear stress (WSS) regions identified by computational fluid dynamics (CFD) predicted clot formation in vivo. Revised designs based on CFD demonstrated superior performance, illustrating the importance of a multipronged approach for a successful design process.


Assuntos
Desenho de Equipamento/instrumentação , Rins Artificiais/efeitos adversos , Trombose/etiologia , Trombose/fisiopatologia , Animais , Simulação por Computador , Cães , Feminino , Hemodinâmica/fisiologia , Hemofiltração/instrumentação , Hidrodinâmica , Ativação Plaquetária , Estresse Mecânico
6.
Clin J Am Soc Nephrol ; 11(8): 1377-1383, 2016 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-27197907

RESUMO

BACKGROUND AND OBJECTIVES: Infection is the most common cause of death in severe AKI, but many patients receiving continuous RRT do not reach target antibiotic concentrations in plasma. Extended infusion of ß-lactams is associated with improved target attainment in critically ill patients; thus, we hypothesized that extended infusion piperacillin-tazobactam would improve piperacillin target attainment compared with short infusion in patients receiving continuous RRT. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We conducted an institutional review board-approved observational cohort study of piperacillin-tazobactam pharmacokinetics and pharmacodynamics in critically ill patients receiving continuous venovenous hemodialysis and hemodiafiltration at three tertiary care hospitals between 2007 and 2015. Antibiotic concentrations in blood and/or dialysate samples were measured by liquid chromatography, and one- and two-compartment pharmacokinetic models were fitted to the data using nonlinear mixed effects regression. Target attainment for piperacillin was defined as achieving four times the minimum inhibitory concentration of 16 µg/ml for >50% of the dosing cycle. The probabilities of target attainment for a range of doses, frequencies, and infusion durations were estimated using a Monte Carlo simulation method. Target attainment was also examined as a function of patient weight and continuous RRT effluent rate. RESULTS: Sixty-eight participants had data for analysis. Regardless of infusion duration, 6 g/d piperacillin was associated with ≤45% target attainment, whereas 12 g/d was associated with ≥95% target attainment. For 8 and 9 g/d, target attainment ranged between 68% and 85%. The probability of target attainment was lower at higher effluent rates and patient weights. For all doses, frequencies, patient weights, and continuous RRT effluent rates, extended infusion was associated with higher probability of target attainment compared with short infusion. CONCLUSIONS: Extended infusions of piperacillin-tazobactam are associated with greater probability of target attainment in patients receiving continuous RRT.


Assuntos
Injúria Renal Aguda/terapia , Antibacterianos/administração & dosagem , Infecções Bacterianas/tratamento farmacológico , Ácido Penicilânico/análogos & derivados , Injúria Renal Aguda/microbiologia , Adulto , Idoso , Antibacterianos/sangue , Antibacterianos/farmacocinética , Infecções Bacterianas/complicações , Estado Terminal , Soluções para Diálise/química , Feminino , Hemodiafiltração , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Ácido Penicilânico/administração & dosagem , Ácido Penicilânico/sangue , Ácido Penicilânico/farmacocinética , Piperacilina/administração & dosagem , Piperacilina/sangue , Piperacilina/farmacocinética , Combinação Piperacilina e Tazobactam , Fatores de Tempo
7.
ASAIO J ; 62(4): 491-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26978710

RESUMO

An implantable hemofilter for the treatment of kidney failure depends critically on the transport characteristics of the membrane and the biocompatibility of the membrane, cartridge, and blood conduits. A novel membrane with slit-shaped pores optimizes the trade-off between permeability and selectivity, enabling implanted therapy. Sustained (3-8) day function of an implanted parallel-plate hemofilter with minimal anticoagulation was achieved by considering biocompatibility at the subnanometer scale of chemical interactions and the millimeter scale of blood fluid dynamics. A total of 400 nm-thick polysilicon flat sheet membranes with 5-8 nm × 2 micron slit-shaped pores were surface-modified with polyethylene glycol. Hemofilter cartridge geometries were refined based on computational fluid dynamics models of blood flow. In an uncontrolled pilot study, silicon filters were implanted in six class A dogs. Cartridges were connected to the cardiovascular system by anastamoses to the aorta and inferior vena cava and filtrate was drained to collection pouches positioned in the peritoneum. Pain medicine and acetylsalicylic acid were administered twice daily until the hemofilters were harvested on postoperative days 3 (n = 2), 4 (n = 2), 5 (n = 1), and 8 (n = 1). No hemofilters were thrombosed. Animals treated for 5 and 8 days had microscopic fractures in the silicon nanopore membranes and 20-50 ml of transudative (albumin sieving coefficient θalb ~ 0.5 - 0.7) fluid in the collection pouches at the time of explant. Shorter experimental durations (3-4 days) resulted in filtration volumes similar to predictions based on mean arterial pressures and membrane hydraulic permeability and (θalb ~ 0.2 - 0.3), similar to preimplantation measurements. In conclusion, a detailed mechanistic and materials science attention to blood-material interactions allows implanted hemofilters to resist thrombosis. Additional testing is needed to determine optimal membrane characteristics and identify limiting factors in long-term implantation.


Assuntos
Hemofiltração/instrumentação , Membranas Artificiais , Nanoporos , Silício , Animais , Cães , Humanos , Projetos Piloto , Trombose/prevenção & controle
10.
Biophys J ; 104(7): 1476-84, 2013 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-23561524

RESUMO

Molecular transport through the basement membrane is important for a number of physiological functions, and dysregulation of basement membrane architecture can have serious pathological consequences. The structure-function relationships that govern molecular transport in basement membranes are not fully understood. The basement membrane from the lens capsule of the eye is a collagen IV-rich matrix that can easily be extracted and manipulated in vitro. As such, it provides a convenient model for studying the functional relationships that govern molecular transport in basement membranes. Here we investigate the effects of increased transmembrane pressure and solute electrical charge on the transport properties of the lens basement membrane (LBM) from the bovine eye. Pressure-permeability relationships in LBM transport were governed primarily by changes in diffusive and convective contributions to solute flux and not by pressure-dependent changes in intrinsic membrane properties. The solute electrical charge had a minimal but statistically significant effect on solute transport through the LBM that was opposite of the expected electrokinetic behavior. The observed transport characteristics of the LBM are discussed in the context of established membrane transport modeling and previous work on the effects of pressure and electrical charge in other basement membrane systems.


Assuntos
Membrana Basal/metabolismo , Condutividade Elétrica , Cristalino/citologia , Substâncias Macromoleculares/metabolismo , Pressão , Animais , Transporte Biológico , Bovinos , Permeabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...