1.
Med Phys ; 10(4): 416-20, 1983.
Artigo em Inglês | MEDLINE | ID: mdl-6412044

RESUMO

An earlier paper [Simpson et al., Med. Phys. 9, 574 (1982)] described a computed tomography (CT) scanner that was constructed by adding a detector array to a 4-MV isocentric linear accelerator. Since the previous article, the detector array has been improved and we now demonstrate better than 3-mm spatial resolution and better than 1% relative electron density discrimination. A series of pictures from volunteer patients is included. Normal anatomy is visualized with bone, muscle, fat, and air being clearly delineated.


Assuntos
Neoplasias/radioterapia , Aceleradores de Partículas , Planejamento de Assistência ao Paciente/métodos , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Carcinoma Broncogênico/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Melanoma/diagnóstico por imagem , Neoplasias Parotídeas/diagnóstico por imagem , Neoplasias Faríngeas/diagnóstico por imagem , Radioterapia de Alta Energia/instrumentação , Neoplasias Retais/diagnóstico por imagem
2.
Med Phys ; 9(4): 574-9, 1982.
Artigo em Inglês | MEDLINE | ID: mdl-7110089

RESUMO

A Varian 4-MV isocentric therapy accelerator has been modified to perform also as a CT scanner. The goal is to provide a computed tomography capability for use in radiotherapy at low cost. We envision three principal uses for the system. These are (i) to provide two and three-dimensional maps of electron density distribution for CT assisted therapy planning; (ii) to aid in patient set up by providing sectional views of the treatment volume and high contrast scout-mode verification images; and (iii) to provide a means for periodically checking the patients anatomical conformation against that which was used to generate the original therapy plan. The machine was modified by mounting an array of detectors on a frame that is bolted to the counterweight end of the gantry in such a manner as to define a "third generation" CT scanner geometry. Details of the detectors and data acquisition electronics are provided. We present results of phantom studies which demonstrate that this prototype system has a spatial resolution of 4 mm and the ability to discriminate electron density differences of less than 1%. We also show that the system is exactly linear over a wide range of electron densities corresponding to those found in body tissues.


Assuntos
Aceleradores de Partículas , Radioterapia/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Planejamento de Assistência ao Paciente