Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 144, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297268

RESUMO

BACKGROUND: Retainers are the only effective approach to prevent orthodontic relapse. The aim of this study was to compare the changes in color and light-transmittance of rough and smooth thermoformed polyurethane and copolymer retainer samples after staining in different solutions and destaining with different approaches. METHODS: Four hundred copolyester (Essix® ACE) and 400 polyurethane (Zendura®) samples with different surface textures, smooth and rough, were stained in 4 different solutions (n = 100 per solution) over 28 days. Each of the four groups of 100 stained samples of each material was subdivided into 5 groups of 20 samples and subjected to different destaining solutions. Light transmittance and color changes were evaluated using a spectrometer and a spectrophotometer. Mean differences were compared using a two-way analysis of variance (ANOVA) and posthoc multiple comparison tests at P = 0.05. RESULTS: No significant differences in light transmittance were found between both untreated materials. Both materials were stained in a similar fashion and showed no significant differences between two materials after staining. Coffee and tea stained both materials more significantly than wine, but there was a significant difference of changes of color and light transmittance between rough and smooth surfaces during the destaining in coffee- and tea-stained samples of copolyester material. All destaining solutions were effective at removing all stains on the samples. The surface roughness of the material plays a significant role in the ability of the materials to be destained, demonstrating a more significant greater effect on cleaning rough samples for improvements in light-transmittance and greater changes in color. CONCLUSIONS: This study concluded that the surface of materials plays a significant role in the material destaining and staining. In addition, the different polymers used for retainer fabrication exhibited different responses during the destaining process depending on types of stains.


Assuntos
Café , Poliuretanos , Humanos , Espectrofotometria , Coloração e Rotulagem , Corantes , Chá , Teste de Materiais , Cor , Propriedades de Superfície , Resinas Compostas
3.
Global Spine J ; 13(1): 242-253, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36367824

RESUMO

STUDY DESIGN: Systematic review and meta-analysis. OBJECTIVES: Determine if tobacco use is associated with increased risk of postoperative adverse events within 90 days in patients undergoing spinal fusion surgery. METHODS: Databases were queried to identify cohort studies that directly compared smokers with non-smokers and provided the absolute number of adverse events and the population at risk. Data quality was evaluated using the Quality in Prognosis Studies tool. Risk ratios (RR) and 95% confidence intervals were calculated and compared between studies. The grading of recommendation, assessment, development and evaluation (GRADE) criteria were used to assess the strength of the evidence. RESULTS: Seventeen studies assessing 37 897 participants met the inclusion criteria. Of these, 10 031 (26.5%) were smokers and 27 866 (73.5%) were nonsmokers. The mean age for the study population was 58 years, and 45% were males. Smoking was not associated with increased risk of one or more major adverse events within 90 days following spine surgery (seven studies, pooled RR 1.13, 95% CI [.75-1.71], I2 = 41%). However, smoking was significantly associated with one or more major adverse events in ≤2 level fusion (three studies, pooled RR 2.46, 95% CI [1.18-5.12], I2 = 0%), but not in fusions of ≥3 levels (four studies, pooled RR .87, 95% CI [.70-1.08], I2 = 0%). Additionally, there was no statistically significant association between smoking and any adverse event, nor increased reoperation risk due to adverse events. CONCLUSIONS: In this meta-analysis, tobacco use was not associated with a statistically significant increased risk of adverse events within 90 days in patients undergoing spinal fusion surgery. Our results are limited by the variable reporting methodology for both complication rates as well as smoking incidence between the included individual studies.

4.
Materials (Basel) ; 15(19)2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-36234148

RESUMO

This study evaluated the efficacy of different cleaning methods with respect to changes in the color and light transmittance of both rough and smooth thermoformed, copolyester retainer specimens, after staining in different solutions. Four hundred copolyester sheets (Essix ACE) specimens were fabricated over molds with different surface textures, smooth and rough. The specimens were stained in four different solutions (n = 100 per solution) over 28 days; then, each of the four groups of 100 stained specimens was sub-divided into five groups of 20 specimens and subjected to a different destaining solution. The specimens were sub-divided with half subjected to an additional ultrasonic cleaning procedure. Light transmittance and color changes were analyzed using a spectrometer/integrating sphere assembly and a spectrophotometer. Mean difference comparisons were performed using appropriate statistical tests at p = 0.05. All five destaining solutions proved to be effective at removing coffee and tea stains. The surface roughness of the retainer material plays a significant role in the ability of cleaning solutions to remove stains, demonstrating a greater effect on cleaning rough specimens with respect to improvements in light transmittance and greater changes in color. Additionally, an ultrasonic cleaning unit generally enhanced the ability of all five solutions to clean the tea-stained specimens. However, the enhancements were only significant for light transmittance.

5.
J Biomed Mater Res B Appl Biomater ; 108(8): 3323-3330, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32562464

RESUMO

OBJECTIVES: Zirconia with 3 mol% yttria (3Y-TZP) has been used for dental crowns and bridges due to its excellent mechanical behavior. Performing fracture toughness testing on this nanograin material, however, can be a challenge. For reliable results, fracture toughness testing requires an extremely sharp notch in the test specimen that closely approximates a very sharp crack. This study was to investigate an alternative method to produce nanometer-sized notches, which are less than the average grain size of 3Y-TZP, during the preparation of single-edge V-notched beam specimens and report the resulting fracture toughness value. METHODS: We present a method using focused ion beam (FIB) milling to fabricate nanometer-sized notches in 3Y-TZP. The notch tip is <100 nm wide, which is smaller than the grain size, and is consistent throughout the thickness of the specimen. RESULTS: The FIB-notched specimens show a much reduced average fracture toughness of 5.64 ± 1.14 MPa√m compared to 8.90 ± 0.23 MPa√m for the specimens without FIB-notches. The FIB-milling did not appear to create any monoclinic phase prior to fracture toughness testing. Fractures originated at the FIB-notches, and the notch size can be readily identified post-mortem using a microscope. A considerable amount of tetragonal-to-monoclinic phase transformation was observed throughout the fracture surfaces. SIGNIFICANCE: FIB milling provides an alternative method to fabricate nanometer-sized notches that are smaller than the grain size of tetragonal zirconia polycrystal. The fracture toughness determined using FIB-notches was ~5.64 MPa√m, smaller than the specimens with V-notches fabricated using saw blades.


Assuntos
Coroas , Prótese Parcial Fixa , Zircônio/química , Materiais Dentários , Testes de Dureza , Teste de Materiais , Tamanho da Partícula , Estresse Mecânico , Ítrio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...