Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(11)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38894470

RESUMO

Fabry disease is a lysosomal storage disorder caused by a significant decrease in the activity or absence of the enzyme α-galactosidase A. The diagnostics of Fabry disease during newborn screening are reasonable, due to the availability of enzyme replacement therapy. This paper presents an electrochemical method using complementary metal-oxide semiconductor (CMOS)-compatible ion-sensitive field effect transistors (ISFETs) with hafnium oxide-sensitive surfaces for the detection of α-galactosidase A activity in dried blood spot extracts. The capability of ISFETs to detect the reaction catalyzed by α-galactosidase A was demonstrated. The buffer composition was optimized to provide suitable conditions for both enzyme and ISFET performance. The use of ISFET structures as sensor elements allowed for the label-free detection of enzymatic reactions with melibiose, a natural substrate of α-galactosidase A, instead of a synthetic fluorogenic one. ISFET chips were packaged with printed circuit boards and microfluidic reaction chambers to enable long-term signal measurement using a custom device. The packaged sensors were demonstrated to discriminate between normal and inhibited GLA activity in dried blood spots extracts. The described method offers a promising solution for increasing the widespread distribution of newborn screening of Fabry disease.


Assuntos
Técnicas Biossensoriais , Teste em Amostras de Sangue Seco , Doença de Fabry , Transistores Eletrônicos , alfa-Galactosidase , alfa-Galactosidase/sangue , Teste em Amostras de Sangue Seco/métodos , Humanos , Doença de Fabry/sangue , Doença de Fabry/diagnóstico , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Recém-Nascido , Triagem Neonatal/métodos
2.
Sensors (Basel) ; 24(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38793863

RESUMO

Biosensors based on ion-sensitive field effect transistors (ISFETs) combined with aptamers offer a promising and convenient solution for point-of-care testing applications due to the ability for fast and label-free detection of a wide range of biomarkers. Mobile and easy-to-use readout devices for the ISFET aptasensors would contribute to further development of the field. In this paper, the development of a portable PC-controlled device for detecting aptamer-target interactions using ISFETs is described. The device assembly allows selective modification of individual ISFETs with different oligonucleotides. Ta2O5-gated ISFET structures were optimized to minimize trapped charge and capacitive attenuation. Integrated CMOS readout circuits with linear transfer function were used to minimize the distortion of the original ISFET signal. An external analog signal digitizer with constant voltage and superimposed high-frequency sine wave reference voltage capabilities was designed to increase sensitivity when reading ISFET signals. The device performance was demonstrated with the aptamer-driven detection of troponin I in both reference voltage setting modes. The sine wave reference voltage measurement method reduced the level of drift over time and enabled a lowering of the minimum detectable analyte concentration. In this mode (constant voltage 2.4 V and 10 kHz 0.1Vp-p), the device allowed the detection of troponin I with a limit of detection of 3.27 ng/mL. Discrimination of acute myocardial infarction was demonstrated with the developed device. The ISFET device provides a platform for the multiplexed detection of different biomarkers in point-of-care testing.


Assuntos
Aptâmeros de Nucleotídeos , Biomarcadores , Técnicas Biossensoriais , Transistores Eletrônicos , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Biomarcadores/análise , Humanos , Troponina I/análise , Troponina I/sangue
3.
Polymers (Basel) ; 15(6)2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36987110

RESUMO

The use of polymers in silicon chips is of great importance for the development of microelectronic and biomedical industries. In this study, new silane-containing polymers, called OSTE-AS polymers, were developed based on off-stoichiometry thiol-ene polymers. These polymers can bond to silicon wafers without pretreatment of the surface by an adhesive. Silane groups were included in the polymer using allylsilanes, with the thiol monomer as the target of modification. The polymer composition was optimized to provide the maximum hardness, the maximum tensile strength, and good bonding with the silicon wafers. The Young's modulus, wettability, dielectric constant, optical transparency, TGA and DSC curves, and the chemical resistance of the optimized OSTE-AS polymer were studied. Thin OSTE-AS polymer layers were obtained on silicon wafers via centrifugation. The possibility of creating microfluidic systems based on OSTE-AS polymers and silicon wafers was demonstrated.

4.
Polymers (Basel) ; 14(10)2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35631871

RESUMO

New modified off-stoichiometry thiol-enes polymers, called OSTE-MS polymers, were developed by introducing mercaptosilane into the polymer mixture. This modification made it possible to introduce silane groups into the polymer frame, due to which the polymer gained the ability to bond with silicon wafers without modification of the wafer surface by any adhesive. The optimal composition for creating 3D polymer structures on a chip was selected, which consists of a volume ratio of 6:6:1 of allyl monomer, mercapto monomer, and mercaptosilane, respectively. The hardness, shift force, tensile strength, Young's modulus, optical transparency, glass transition temperature, thermal stability, and chemical resistance of the OSTE-MS polymer, and the viscosity for the prepolymer mixture were studied. On the basis of the OSTE-MS polymer, 3D polymer structures of the well type and microfluidic system on the silicon chips were obtained.

5.
Biosens Bioelectron ; 129: 29-35, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30682686

RESUMO

A new bioelectronic nose based on a field effect transistor coupled with an aptamer as the sensing element was developed. The gas-to-liquid extraction interface required for appropriate aptamer function was integrated into standard CMOS technology. It was developed with the use of a sacrificial aluminium etching technique combined with surface modifications by silanes for wettability control. As a proof of concept, aptamer Van74 for vanillin was immobilized on the sensitive surface of the ISFET. The developed microsystem can selectively detect vanillin vapor in a concentration range from 2.7 ppt to 0.3 ppm, with a detection limit of 2.7 ppt. The sensor was able to detect vanillin in a gas sample obtained from roasted coffee beans. This outcome provides a foundation for developing a new generation of bioelectronic noses for the detection and discrimination of volatile compounds.


Assuntos
Aptâmeros de Nucleotídeos/química , Benzaldeídos/análise , Técnicas Biossensoriais/instrumentação , Nariz Eletrônico , Transistores Eletrônicos , Compostos Orgânicos Voláteis/análise , Desenho de Equipamento , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Membranas Artificiais , Volatilização
6.
Sensors (Basel) ; 18(1)2017 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-29278396

RESUMO

The electrochemical detection of interactions between aptamers and low-molecular-weight targets often lacks sensitivity. Signal amplification improves the detection of the aptamer-analyte complex; Bsm DNA polymerase was used to amplify the signal from the interaction of vanillin and its aptamer named Van_74 on an ion-sensitive field-effect transistor (ISFET)-based biosensor. The aptamer was immobilized on the ISFET sensitive surface. A short DNA probe was hybridized with the aptamer and dissociated from it upon vanillin addition. A free probe interacted with a special DNA molecular beacon initiated the Bsm DNA polymerase reaction that was detected by ISFET. A buffer solution suitable for both aptamer action and Bsm DNA polymerase activity was determined. The ISFET was shown to detect the Bsm DNA polymerase reaction under the selected conditions. Vanillin at different concentrations (1 × 10-6-1 × 10-8 M) was detected using the biosensor with signal amplification. The developed detection system allowed for the determination of vanillin, starting at a 10-8 M concentration. Application of the Bsm DNA polymerase resulted in a 15.5 times lower LoD when compared to the biosensor without signal amplification (10.1007/s00604-017-2586-4).


Assuntos
Benzaldeídos/química , Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , DNA Polimerase Dirigida por DNA , Técnicas Eletroquímicas , Ouro
7.
Mikrochim Acta ; 185(1): 3, 2017 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-29594590

RESUMO

An aptamer for vanillin was obtained and then used for the development of an aptasensor based on an ion-sensitive field-effect transistor (ISFET). This aptamer (a single-stranded DNA;ssDNA) was selected using the Capture-SELEX protocol, which suites well for selection of aptamers to small molecules. Among six aptamer candidates, the aptamer Van_74 with the highest affinity for vanillin was chosen (elution of 35% of the aptamer from a solid support in the presence of 2 mM of vanillin). Van_74 was characterized using nondenaturating PAGE of washouts from magnetic beads. It is shown that Van_74 binds to vanillin with an dissociation constant of >7.8 µM (determined by nondenaturating PAGE) and it was specific to vanillin in comparison with interferents: benzaldehyde, guaiacol, furaneol, ethyl guaiacol and ethyl vanillin. Also it was shown that change of buffer composition greatly affected the binding ability of Van_74. For biosensor fabrication aptamer was immobilised on the Ta2O5-sensitive surface of the ISFET via "click-chemistry". Detection scheme implied dehybridisation of the ssDNA probe from the aptamer and release in the solution during the addition of vanillin. As a result, the surface potential increase upon vanillin binding with the aptamer was detected by the transistor. The biosensor had a detection limit of 1.55 × 10-7 M and a dynamic range from 1.55 × 10-7 M to 1 × 10-6 M. Effective constant Kd,eff for vanillin binding on biosensor surface was calculated to be (9 ± 3) × 10-7 M. This allows selective detection of vanillin in the mixture of interferents and in samples of coffee extract. Graphical abstract A biosensor for vanillin was developed on the basis of an aptamer that was obtained via Capture-SELEX and by using an ISFET. This biosensor can be used for vanillin detection in presence of interferents and in real sample using an approach of ssDNA probe dehybridization.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...