Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 119(4): 1275-1284, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38367914

RESUMO

PURPOSE: Targeted radiopharmaceutical therapy (RPT) in combination with external beam radiation therapy (EBRT) shows promise as a method to increase tumor control and mitigate potential high-grade toxicities associated with re-treatment for patients with recurrent head and neck cancer. This work establishes a patient-specific dosimetry framework that combines Monte Carlo-based dosimetry from the 2 radiation modalities at the voxel level using deformable image registration (DIR) and radiobiological constructs for patients enrolled in a phase 1 clinical trial combining EBRT and RPT. METHODS AND MATERIALS: Serial single-photon emission computed tomography (SPECT)/computed tomography (CT) patient scans were performed at approximately 24, 48, 72, and 168 hours postinjection of 577.2 MBq/m2 (15.6 mCi/m2) CLR 131, an iodine 131-containing RPT agent. Using RayStation, clinical EBRT treatment plans were created with a treatment planning CT (TPCT). SPECT/CT images were deformably registered to the TPCT using the Elastix DIR module in 3D Slicer software and assessed by measuring mean activity concentrations and absorbed doses. Monte Carlo EBRT dosimetry was computed using EGSnrc. RPT dosimetry was conducted using RAPID, a GEANT4-based RPT dosimetry platform. Radiobiological metrics (biologically effective dose and equivalent dose in 2-Gy fractions) were used to combine the 2 radiation modalities. RESULTS: The DIR method provided good agreement for the activity concentrations and calculated absorbed dose in the tumor volumes for the SPECT/CT and TPCT images, with a maximum mean absorbed dose difference of -11.2%. Based on the RPT absorbed dose calculations, 2 to 4 EBRT fractions were removed from patient EBRT treatments. For the combined treatment, the absorbed dose to target volumes ranged from 57.14 to 75.02 Gy. When partial volume corrections were included, the mean equivalent dose in 2-Gy fractions to the planning target volume from EBRT + RPT differed -3.11% to 1.40% compared with EBRT alone. CONCLUSIONS: This work demonstrates the clinical feasibility of performing combined EBRT + RPT dosimetry on TPCT scans. Dosimetry guides treatment decisions for EBRT, and this work provides a bridge for the same paradigm to be implemented within the rapidly emerging clinical RPT space.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioisótopos do Iodo , Método de Monte Carlo , Compostos Radiofarmacêuticos , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Radioisótopos do Iodo/uso terapêutico , Radioisótopos do Iodo/administração & dosagem , Planejamento da Radioterapia Assistida por Computador/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Radiometria/métodos
2.
Pharmaceuticals (Basel) ; 16(7)2023 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-37513891

RESUMO

BACKGROUND: Osteosarcoma (OS) represents the most common primary bone tumor in humans and in companion dogs, being practically phenotypically identical. There is a need for effective treatments to extend the survival of patients with OS. Here, we examine the dosimetry in beagle dogs and cross-reactivity with human tissues of a novel human antibody, IF3, that targets the insulin growth factor receptor type 2 (IGF2R), which is overexpressed on OS cells, making it a candidate for radioimmunotherapy of OS. METHODS: [89Zr]Zr-DFO-IF3 was injected into three healthy beagle dogs. PET/CT was conducted at 4, 24, 48, and 72 h. RAPID analysis was used to determine the dosimetry of [177Lu]Lu-CHXA"-IF3 for a clinical trial in companion dogs with OS. IF3 antibody was biotinylated, and a multitude of human tissues were assessed with immunohistochemistry. RESULTS: PET/CT revealed that only the liver, bone marrow, and adrenal glands had high uptake. Clearance was initially through renal and hepatobiliary excretion in the first 72 h followed by primarily physical decay. RAPID analysis showed bone marrow to be the dose-limiting organ with a therapeutic range for 177Lu calculated to be 0.487-0.583 GBq. Immunohistochemistry demonstrated the absence of IGF2R expression on the surface of healthy human cells, thus suggesting that radioimmunotherapy with [177Lu]Lu-CHXA"-IF3 will be well tolerated. CONCLUSIONS: Image-based dosimetry has defined a safe therapeutic range for canine clinical trials, while immunohistochemistry has suggested that the antibody will not cross-react with healthy human tissues.

3.
Biomed Phys Eng Express ; 9(4)2023 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-37084718

RESUMO

Voxel-level dosimetry based on nuclear medicine images offers patient-specific personalization of radiopharmaceutical therapy (RPT) treatments. Clinical evidence is emerging demonstrating improvements in treatment precision in patients when voxel-level dosimetry is used compared to MIRD. Voxel-level dosimetry requires absolute quantification of activity concentrations in the patient, but images from SPECT/CT scanners are not quantitative and require calibration using nuclear medicine phantoms. While phantom studies can validate a scanner's ability to recover activity concentrations, these studies provide only a surrogate for the true metric of interest: absorbed doses. Measurements using thermoluminescent dosimeters (TLDs) are a versatile and accurate method of measuring absorbed dose. In this work, a TLD probe was manufactured that can fit into currently available nuclear medicine phantoms for the measurement of absorbed dose of RPT agents. Next, 748 MBq of I-131 was administered to a 16 ml hollow source sphere placed in a 6.4 L Jaszczak phantom in addition to six TLD probes, each holding 4 TLD-100 1 × 1 × 1 mm TLD-100 (LiF:Mg,Ti) microcubes. The phantom then underwent a SPECT/CT scan in accordance with a standard SPECT/CT imaging protocol for I-131. The SPECT/CT images were then input into a Monte Carlo based RPT dosimetry platform named RAPID and a three dimensional dose distribution in the phantom was estimated. Additionally, a GEANT4 benchmarking scenario (denoted 'idealized') was created using a stylized representation of the phantom. There was good agreement for all six probes, the differences between measurement and RAPID ranged between -5.5% and 0.9%. The difference between the measured and the idealized GEANT4 scenario was calculated and ranged from -4.3% and -20.5%. This work demonstrates good agreement between TLD measurements and RAPID. In addition, it introduces a novel TLD probe that can be easily introduced into clinical nuclear medicine workflows to provide QA of image-based dosimetry for RPT treatments.


Assuntos
Radioisótopos do Iodo , Compostos Radiofarmacêuticos , Humanos , Fluxo de Trabalho , Radiometria/métodos
4.
Med Phys ; 49(8): 5491-5503, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35607296

RESUMO

PURPOSE: Approximately 50% of head and neck cancer (HNC) patients will experience loco-regional disease recurrence following initial courses of therapy. Retreatment with external beam radiotherapy (EBRT) is technically challenging and may be associated with a significant risk of irreversible damage to normal tissues. Radiopharmaceutical therapy (RPT) is a potential method to treat recurrent HNC in conjunction with EBRT. Phantoms are used to calibrate and add quantification to nuclear medicine images, and anthropomorphic phantoms can account for both the geometrical and material composition of the head and neck. In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom, and its characterization for the validation of a Monte Carlo, SPECT image-based, 131 I RPT dosimetry workflow. METHODS: 3D-printing techniques were used to create the anthropomorphic phantom from a patient CT dataset. Three 131 I SPECT/CT imaging studies were performed using a homogeneous, Jaszczak, and an anthropomorphic phantom to quantify the SPECT images using a GE Optima NM/CT 640 with a high energy general purpose collimator. The impact of collimator detector response (CDR) modeling and volume-based partial volume corrections (PVCs) upon the absorbed dose was calculated using an image-based, Geant4 Monte Carlo RPT dosimetry workflow and compared against a ground truth scenario. Finally, uncertainties were quantified in accordance with recent EANM guidelines. RESULTS: The 3D-printed anthropomorphic phantom was an accurate re-creation of patient anatomy including bone. The extrapolated Jaszczak recovery coefficients were greater than that of the 3D-printed insert (∼22.8 ml) for both the CDR and non-CDR cases (with CDR: 0.536 vs. 0.493, non-CDR: 0.445 vs. 0.426, respectively). Utilizing Jaszczak phantom PVCs, the absorbed dose was underpredicted by 0.7% and 4.9% without and with CDR, respectively. Utilizing anthropomorphic phantom recovery coefficient overpredicted the absorbed dose by 3% both with and without CDR. All dosimetry scenarios that incorporated PVC were within the calculated uncertainty of the activity. The uncertainties in the cumulative activity ranged from 23.6% to 106.4% for Jaszczak spheres ranging in volume from 0.5 to 16 ml. CONCLUSION: The accuracy of Monte Carlo-based dosimetry for 131 I RPT in HNC was validated with an anthropomorphic phantom. In this study, it was found that Jaszczak-based PVCs were sufficient. Future applications of the phantom could involve 3D printing and characterizing patient-specific volumes for more personalized RPT dosimetry estimates.


Assuntos
Radiometria , Compostos Radiofarmacêuticos , Humanos , Radioisótopos do Iodo , Método de Monte Carlo , Imagens de Fantasmas , Impressão Tridimensional , Radiometria/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Fluxo de Trabalho
5.
Pharmaceutics ; 15(1)2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36678756

RESUMO

Targeted radionuclide therapy (TRT) and immunotherapy are rapidly growing classes of cancer treatments. Basic, translational, and clinical research are now investigating therapeutic combinations of these agents. In comparison to external beam radiation therapy (EBRT), TRT has the unique advantage of treating all disease sites following intravenous injection and selective tumor uptake and retention-a particularly beneficial property in metastatic disease settings. The therapeutic value of combining radiation therapy with immune checkpoint blockade to treat metastases has been demonstrated in preclinical studies, whereas results of clinical studies have been mixed. Several clinical trials combining TRT and immune checkpoint blockade have been initiated based on preclinical studies combining these with EBRT and/or TRT. Despite the interest in translation of TRT and immunotherapy combinations, many questions remain surrounding the mechanisms of interaction and the optimal approach to clinical implementation of these combinations. This review highlights the mechanisms of interaction between anti-tumor immunity and radiation therapy and the status of basic and translational research and clinical trials investigating combinations of TRT and immunotherapies.

6.
Theranostics ; 11(13): 6120-6137, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33995649

RESUMO

Rationale: Clinical interest in combining targeted radionuclide therapies (TRT) with immunotherapies is growing. External beam radiation therapy (EBRT) activates a type 1 interferon (IFN1) response mediated via stimulator of interferon genes (STING), and this is critical to its therapeutic interaction with immune checkpoint blockade. However, little is known about the time course of IFN1 activation after EBRT or whether this may be induced by decay of a TRT source. Methods: We examined the IFN1 response and expression of immune susceptibility markers in B78 and B16 melanomas and MOC2 head and neck cancer murine models using qPCR and western blot. For TRT, we used 90Y chelated to NM600, an alkylphosphocholine analog that exhibits selective uptake and retention in tumor cells including B78 and MOC2. Results: We observed significant IFN1 activation in all cell lines, with peak activation in B78, B16, and MOC2 cell lines occurring 7, 7, and 1 days, respectively, following RT for all doses. This effect was STING-dependent. Select IFN response genes remained upregulated at 14 days following RT. IFN1 activation following STING agonist treatment in vitro was identical to RT suggesting time course differences between cell lines were mediated by STING pathway kinetics and not DNA damage susceptibility. In vivo delivery of EBRT and TRT to B78 and MOC2 tumors resulted in a comparable time course and magnitude of IFN1 activation. In the MOC2 model, the combination of 90Y-NM600 and dual checkpoint blockade therapy reduced tumor growth and prolonged survival compared to single agent therapy and cumulative dose equivalent combination EBRT and dual checkpoint blockade therapy. Conclusions: We report the time course of the STING-dependent IFN1 response following radiation in multiple murine tumor models. We show the potential of TRT to stimulate IFN1 activation that is comparable to that observed with EBRT and this may be critical to the therapeutic integration of TRT with immunotherapies.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Interferon Tipo I/fisiologia , Melanoma Experimental/radioterapia , Animais , Carcinoma de Células Escamosas/imunologia , Carcinoma de Células Escamosas/fisiopatologia , Linhagem Celular Tumoral , Terapia Combinada , Relação Dose-Resposta à Radiação , Feminino , Regulação Neoplásica da Expressão Gênica/efeitos da radiação , Técnicas de Inativação de Genes , Neoplasias de Cabeça e Pescoço/patologia , Inibidores de Checkpoint Imunológico , Interferon Tipo I/biossíntese , Interferon Tipo I/genética , Linfócitos/efeitos dos fármacos , Linfócitos/efeitos da radiação , Melanoma Experimental/imunologia , Melanoma Experimental/fisiopatologia , Proteínas de Membrana/agonistas , Proteínas de Membrana/deficiência , Proteínas de Membrana/genética , Proteínas de Membrana/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Proteínas de Neoplasias/agonistas , Proteínas de Neoplasias/fisiologia , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/uso terapêutico , Fatores de Tempo , Proteína Tumoral 1 Controlada por Tradução , Ensaio Tumoral de Célula-Tronco , Regulação para Cima , Radioisótopos de Ítrio/farmacocinética , Radioisótopos de Ítrio/uso terapêutico
7.
Radiat Res ; 195(6): 522-540, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33826741

RESUMO

Brain metastases develop in over 60% of advanced melanoma patients and negatively impact quality of life and prognosis. In a murine melanoma model, we previously showed that an in situ vaccination (ISV) regimen, combining radiation treatment and intratumoral (IT) injection of immunocytokine (IC: anti-GD2 antibody fused to IL2), along with the immune checkpoint inhibitor anti-CTLA-4, robustly eliminates peripheral flank tumors but only has modest effects on co-occurring intracranial tumors. In this study, we investigated the ability of low-dose radiation to the brain to potentiate anti-tumor immunity against a brain tumor when combined with ISV + anti-CTLA-4. B78 (GD2+, immunologically "cold") melanoma tumor cells were implanted into the flank and the right striatum of the brain in C57BL/6 mice. Flank tumors (50-150 mm3) were treated following a previously optimized ISV regimen [radiation (12 Gy × 1, treatment day 1), IT-IC (50 µg daily, treatment days 6-10), and anti-CTLA-4 (100 µg, treatment days 3, 6, 9)]. Mice that additionally received whole-brain radiation treatment (WBRT, 4 Gy × 1) on day 15 demonstrated significantly increased survival compared to animals that received ISV + anti-CTLA-4 alone, WBRT alone or no treatment (control) (P < 0.001, log-rank test). Timing of WBRT was critical, as WBRT administration on day 1 did not significantly enhance survival compared to ISV + anti-CTLA-4, suggesting that the effect of WBRT on survival might be mediated through immune modulation and not just direct tumor cell cytotoxicity. Modest increases in T cells (CD8+ and CD4+) and monocytes/macrophages (F4/80+) but no changes in FOXP3+ regulatory T cells (Tregs), were observed in brain melanoma tumors with addition of WBRT (on day 15) to ISV + anti-CTLA-4. Cytokine multiplex immunoassay revealed distinct changes in both intracranial melanoma and contralateral normal brain with addition of WBRT (day 15) to ISV + anti-CTLA-4, with notable significant changes in pro-inflammatory (e.g., IFNγ, TNFα and LIX/CXCL5) and suppressive (e.g., IL10, IL13) cytokines as well as chemokines (e.g., IP-10/CXCL10 and MIG/CXCL9). We tested the ability of the alkylphosphocholine analog, NM600, to deliver immunomodulatory radiation to melanoma brain tumors as a targeted radionuclide therapy (TRT). Yttrium-86 (86Y) chelated to NM600 was delivered intravenously by tail vein to mice harboring flank and brain melanoma tumors, and PET imaging demonstrated specific accumulation up to 72 h at each tumor site (∼12:1 brain tumor/brain and ∼8:1 flank tumor/muscle). When NM600 was chelated to therapeutic ß-particle-emitting 90Y and administered on treatment day 13, T-cell infiltration and cytokine profiles were altered in melanoma brain tumor, like that observed for WBRT. Overall, our results demonstrate that addition of low-dose radiation, timed appropriately with ISV administration to tumors outside the brain, significantly increases survival in animals co-harboring melanoma brain tumors. This observation has potentially important translational implications as a treatment strategy for increasing the response of tumors in the brain to systemically administered immunotherapies.


Assuntos
Neoplasias Encefálicas/imunologia , Imunidade/efeitos da radiação , Melanoma Experimental/imunologia , Vacinação , Animais , Neoplasias Encefálicas/prevenção & controle , Linhagem Celular Tumoral , Relação Dose-Resposta à Radiação , Inibidores de Checkpoint Imunológico/farmacologia , Imunidade/efeitos dos fármacos , Melanoma Experimental/prevenção & controle , Camundongos , Camundongos Endogâmicos C57BL , Proteína Tumoral 1 Controlada por Tradução
8.
J Nucl Med ; 61(8): 1187-1194, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31862799

RESUMO

There is a clinically unmet need for effective treatments for triple-negative breast cancer (TNBC), as it remains the most aggressive subtype of breast cancer. Herein, we demonstrate a promising strategy using a tumor-targeting alkylphosphocholine (NM600) for targeted radionuclide therapy of TNBC. Methods: NM600 was radiolabeled with 86Y for PET imaging and 177Lu for targeted radionuclide therapy. 86Y-NM600 PET imaging was performed on female BALB/C mice bearing syngeneic 4T07 (nonmetastatic) and 4T1 (metastatic) TNBC tumor grafts (n = 3-5). Quantitative data derived from a PET-image region-of-interest analysis, which was corroborated by ex vivo biodistribution, were used to estimate the dosimetry of 177Lu-NM600 treatments. Weight measurement, complete blood counts, and histopathology analysis were performed to determine 177Lu-NM600 toxicity in naïve BALB/C mice administered 9.25 or 18.5 MBq. Groups of mice bearing 4T07 or 4T1 grafts (n = 5-6) received excipient or 9.25 or 18.5 MBq of 177Lu-NM600 as a single or fractionated schedule, and tumor growth and overall survival were monitored. Results: Excellent tumor targeting and rapid normal-tissue clearance of 86Y-NM600 were noted in both 4T07 and 4T1 murine models. Ex vivo biodistribution corroborated the accuracy of the PET data and validated 86Y-NM600 as a surrogate for 177Lu-NM600. 177Lu-NM600 dosimetry showed absorbed doses of 2.04 ± 0.32 and 1.68 ± 0.06 Gy/MBq to 4T07 and 4T1 tumors, respectively, which were larger than those delivered to liver (1.28 ± 0.09 Gy/MBq) and to bone marrow (0.31 ± 0.05 Gy/MBq). The 177Lu-NM600 injected activities used for treatment were well tolerated and resulted in significant tumor growth inhibition and prolonged overall survival in both tested TNBC models. A complete response was attained in 60% of treated mice bearing 4T07 grafts. Conclusion: Overall, our results suggest that 177Lu-NM600 targeted radionuclide therapy has potential for TNBC and merits further exploration in a clinical setting.


Assuntos
Neoplasias de Mama Triplo Negativas/radioterapia , Animais , Linhagem Celular Tumoral , Modelos Animais de Doenças , Lutécio/química , Camundongos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioquímica , Radioisótopos/química , Radiometria , Análise de Sobrevida , Distribuição Tecidual , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem , Neoplasias de Mama Triplo Negativas/metabolismo , Neoplasias de Mama Triplo Negativas/patologia
9.
J Nucl Med ; 60(11): 1622-1628, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30954941

RESUMO

We characterize the in vivo biodistribution and tumor selectivity of 86Y-NM600, a theranostic alkylphosphocholine radiometal chelate with broad tumor selectivity, in a variety of preclinical cancer models. Methods: Mice bearing flank tumors (representative of lung, pancreatic, prostate, liver, skin, and lymphoid cancers) were injected intravenously with 9.25 MBq of 86Y-NM600 and imaged longitudinally over 4-5 d using small-animal PET/CT. Percentage injected activity per gram (%IA/g) for each volume of interest was measured at each time point for the organs of interest. Mice were euthanized after the final time point, and the tumor and organs of interest were counted with an automatic γ-counter. Absorbed doses delivered by 90Y-NM600 per injected activity (Gy/MBq) were estimated. Mice bearing B78 flank tumors were injected with a prescription of 90Y-NM600 that delivered 2.5 Gy of absorbed tumor dose and was compared with an equivalent absorbed dose delivered via external-beam radiotherapy using tumor volume as a measure of response. Histology and complete blood counts were analyzed in naïve C57BL/6 mice that were injected with 9.25 MBq of 90Y-NM600 at 5, 10, and 28 d after injection. Results: PET imaging showed consistent tumor accumulation and retention across all tumor models investigated, with little off-target retention of NM600 except in the liver, as is characteristic of hepatobiliary metabolism. The tumor uptake was highest in the pancreatic and lymphoid cancer models, reaching peak concentrations of 9.34 ± 2.66 %IA/g (n = 3) and 9.10 ± 0.13 %IA/g (n = 3), respectively, at approximately 40-48 h after injection. These corresponded to tumor dose estimates of 2.72 ± 0.33 Gy/MBq and 2.67 ± 0.32 Gy/MBq, respectively. In the toxicity study, there were no visible signs of acute toxicity by histology, and perturbation of hematologic parameters was transient when observed, returning to pretherapy levels after 28 d. Conclusion: NM600 is a theranostic agent with a unique ability to selectively target a variety of cancer types, presenting a unique opportunity for PET image-guided targeted radionuclide therapy and combination with immunotherapies.


Assuntos
Fosforilcolina/química , Radioisótopos de Ítrio , Animais , Linhagem Celular Tumoral , Transformação Celular Neoplásica , Humanos , Camundongos , Fosforilcolina/farmacocinética , Radioquímica , Radiometria , Distribuição Tecidual
10.
Commun Biol ; 2: 79, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30820474

RESUMO

Finding improved therapeutic strategies against T-cell Non-Hodgkin's Lymphoma (NHL) remains an unmet clinical need. We implemented a theranostic approach employing a tumor-targeting alkylphosphocholine (NM600) radiolabeled with 86Y for positron emission tomography (PET) imaging and 90Y for targeted radionuclide therapy (TRT) of T-cell NHL. PET imaging and biodistribution performed in mouse models of T-cell NHL showed in vivo selective tumor uptake and retention of 86Y-NM600. An initial toxicity assessment examining complete blood counts, blood chemistry, and histopathology of major organs established 90Y-NM600 safety. Mice bearing T-cell NHL tumors treated with 90Y-NM600 experienced tumor growth inhibition, extended survival, and a high degree of cure with immune memory toward tumor reestablishment. 90Y-NM600 treatment was also effective against disseminated tumors, improving survival and cure rates. Finally, we observed a key role for the adaptive immune system in potentiating a durable anti-tumor response to TRT, especially in the presence of microscopic disease.


Assuntos
Memória Imunológica/efeitos da radiação , Linfoma de Células T/radioterapia , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Ítrio/uso terapêutico , Animais , Linhagem Celular Tumoral , Feminino , Humanos , Memória Imunológica/imunologia , Linfoma de Células T/diagnóstico por imagem , Linfoma de Células T/imunologia , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos SCID , Distribuição Tecidual/imunologia , Distribuição Tecidual/efeitos da radiação , Carga Tumoral/imunologia , Carga Tumoral/efeitos da radiação , Proteína Tumoral 1 Controlada por Tradução , Ensaios Antitumorais Modelo de Xenoenxerto/métodos , Radioisótopos de Ítrio/sangue , Radioisótopos de Ítrio/farmacocinética
11.
Cancer Biother Radiopharm ; 34(1): 13-23, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30351218

RESUMO

INTRODUCTION: CLR1404 is a theranostic molecular agent that can be radiolabeled with 124I (CLR 124) for positron emission tomography (PET) imaging, or 131I (CLR 131) for single-photon emission computed tomography (SPECT) imaging and targeted radionuclide therapy. This pilot study evaluated a pretreatment dosimetry methodology in a triple-negative breast cancer patient who was uniquely enrolled in both a CLR 124 PET imaging clinical trial and a CLR 131 therapeutic dose escalation clinical trial. MATERIALS AND METHODS: Three-dimensional PET/CT images were acquired at 1, 3, 24, 48, and 120 h postinjection of 178 MBq CLR 124. One month later, pretherapy 2D whole-body planar images were acquired at 0.25, 5, 24, 48, and 144 h postinjection of 370 MBq CLR 131. Following the therapeutic administration of 1990 MBq CLR 131, 3D SPECT/CT images were acquired at 74, 147, 334, and 505 h postinjection. The therapeutic CLR 131 voxel-level absorbed dose was estimated from PET (RAPID PET) and SPECT (RAPID SPECT) images using a Geant4-based Monte Carlo dosimetry platform called RAPID (Radiopharmaceutical Assessment Platform for Internal Dosimetry), and region of interest (ROI) mean doses were also estimated using the OLINDA/EXM software based on PET (OLINDA PET), SPECT (OLINDA SPECT), and planar (OLINDA planar) images. RESULTS: The RAPID PET and OLINDA PET tracer-predicted ROI mean doses correlated well (m ≥ 0.631, R2 ≥ 0.694, p ≤ 0.01) with both the RAPID SPECT and OLINDA SPECT therapeutic mean doses. The 2D planar images did not have any significant correlations. The ROI mean doses differed by -4% to -43% between RAPID and OLINDA/EXM, and by -19% to 29% between PET and SPECT. The 3D dose distributions and dose volume histograms calculated with RAPID were similar for the PET/CT and SPECT/CT. CONCLUSIONS: This pilot study demonstrated that CLR 124 pretreatment PET images can be used to predict CLR 131 3D therapeutic dosimetry better than CLR 131 2D planar images. In addition, unlike OLINDA/EXM, Monte Carlo dosimetry methods were capable of accurately predicting dose heterogeneity, which is important for predicting dose-response relationships and clinical outcomes.


Assuntos
Imageamento Tridimensional/métodos , Iodobenzenos/administração & dosagem , Éteres Fosfolipídicos/administração & dosagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem , Neoplasias de Mama Triplo Negativas/radioterapia , Feminino , Humanos , Projetos Piloto , Estudos Retrospectivos
12.
Cancer Biother Radiopharm ; 33(4): 155-165, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29694246

RESUMO

This work describes the development and validation of a patient-specific Monte Carlo internal dosimetry platform called RAPID (Radiopharmaceutical Assessment Platform for Internal Dosimetry). RAPID utilizes serial PET/CT or SPECT/CT images to calculate voxelized three-dimensional (3D) internal dose distributions with the Monte Carlo code Geant4. RAPID's dosimetry calculations were benchmarked against previously published S-values and specific absorbed fractions (SAFs) calculated for monoenergetic photon and electron sources within the Zubal phantom and for S-values calculated for a variety of radionuclides within spherical tumor phantoms with sizes ranging from 1 to 1000 g. The majority of the S-values and SAFs calculated in the Zubal Phantom were within 5% of the previously published values with the exception of a few 10 keV photon SAFs that agreed within 10%, and one value within 16%. The S-values calculated in the spherical tumor phantoms agreed within 2% for 177Lu, 131I, 125I, 18F, and 64Cu, within 3.5% for 211At and 213Bi, within 6.5% for 153Sm, 111In, 89Zr, and 223Ra, and within 9% for 90Y, 68Ga, and 124I. In conclusion, RAPID is capable of calculating accurate internal dosimetry at the voxel-level for a wide variety of radionuclides and could be a useful tool for calculating patient-specific 3D dose distributions.


Assuntos
Imageamento Tridimensional/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos
13.
Phys Med Biol ; 62(15): 6008-6025, 2017 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-28682793

RESUMO

Variations in tumor volume segmentation methods in targeted radionuclide therapy (TRT) may lead to dosimetric uncertainties. This work investigates the impact of PET and MRI threshold-based tumor segmentation on TRT dosimetry in patients with primary and metastatic brain tumors. In this study, PET/CT images of five brain cancer patients were acquired at 6, 24, and 48 h post-injection of 124I-CLR1404. The tumor volume was segmented using two standardized uptake value (SUV) threshold levels, two tumor-to-background ratio (TBR) threshold levels, and a T1 Gadolinium-enhanced MRI threshold. The dice similarity coefficient (DSC), jaccard similarity coefficient (JSC), and overlap volume (OV) metrics were calculated to compare differences in the MRI and PET contours. The therapeutic 131I-CLR1404 voxel-level dose distribution was calculated from the 124I-CLR1404 activity distribution using RAPID, a Geant4 Monte Carlo internal dosimetry platform. The TBR, SUV, and MRI tumor volumes ranged from 2.3-63.9 cc, 0.1-34.7 cc, and 0.4-11.8 cc, respectively. The average ± standard deviation (range) was 0.19 ± 0.13 (0.01-0.51), 0.30 ± 0.17 (0.03-0.67), and 0.75 ± 0.29 (0.05-1.00) for the JSC, DSC, and OV, respectively. The DSC and JSC values were small and the OV values were large for both the MRI-SUV and MRI-TBR combinations because the regions of PET uptake were generally larger than the MRI enhancement. Notable differences in the tumor dose volume histograms were observed for each patient. The mean (standard deviation) 131I-CLR1404 tumor doses ranged from 0.28-1.75 Gy GBq-1 (0.07-0.37 Gy GBq-1). The ratio of maximum-to-minimum mean doses for each patient ranged from 1.4-2.0. The tumor volume and the interpretation of the tumor dose is highly sensitive to the imaging modality, PET enhancement metric, and threshold level used for tumor volume segmentation. The large variations in tumor doses clearly demonstrate the need for standard protocols for multimodality tumor segmentation in TRT dosimetry.


Assuntos
Iodobenzenos/uso terapêutico , Imageamento por Ressonância Magnética/métodos , Método de Monte Carlo , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Éteres Fosfolipídicos/uso terapêutico , Tomografia por Emissão de Pósitrons/métodos , Humanos , Imagem Multimodal/métodos , Neoplasias/patologia , Radiometria/métodos , Carga Tumoral
14.
Nat Rev Clin Oncol ; 14(6): 347-364, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28094261

RESUMO

Over the past two decades, synergistic innovations in imaging technology have resulted in a revolution in which a range of biomedical applications are now benefiting from fluorescence imaging. Specifically, advances in fluorophore chemistry and imaging hardware, and the identification of targetable biomarkers have now positioned intraoperative fluorescence as a highly specific real-time detection modality for surgeons in oncology. In particular, the deeper tissue penetration and limited autofluorescence of near-infrared (NIR) fluorescence imaging improves the translational potential of this modality over visible-light fluorescence imaging. Rapid developments in fluorophores with improved characteristics, detection instrumentation, and targeting strategies led to the clinical testing in the early 2010s of the first targeted NIR fluorophores for intraoperative cancer detection. The foundations for the advances that underline this technology continue to be nurtured by the multidisciplinary collaboration of chemists, biologists, engineers, and clinicians. In this Review, we highlight the latest developments in NIR fluorophores, cancer-targeting strategies, and detection instrumentation for intraoperative cancer detection, and consider the unique challenges associated with their effective application in clinical settings.


Assuntos
Corantes Fluorescentes , Neoplasias/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Descoberta de Drogas/métodos , Descoberta de Drogas/tendências , Humanos , Verde de Indocianina , Cuidados Intraoperatórios , Ácidos Levulínicos , Azul de Metileno , Neoplasias/cirurgia , Ácido Aminolevulínico
15.
PLoS One ; 9(11): e111652, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25402488

RESUMO

INTRODUCTION: (131)I-CLR1404 is a small molecule that combines a tumor-targeting moiety with a therapeutic radioisotope. The primary aim of this phase 1 study was to determine the administered radioactivity expected to deliver 400 mSv to the bone marrow. The secondary aims were to determine the pharmacokinetic (PK) and safety profiles of (131)I-CLR1404. METHODS: Eight subjects with refractory or relapsed advanced solid tumors were treated with a single injection of 370 MBq of (131)I-CLR1404. Whole body planar nuclear medicine scans were performed at 15-35 minutes, 4-6, 18-24, 48, 72, 144 hours, and 14 days post injection. Optional single photon emission computed tomography imaging was performed on two patients 6 days post injection. Clinical laboratory parameters were evaluated in blood and urine. Plasma PK was evaluated on (127)I-CLR1404 mass measurements. To evaluate renal clearance of (131)I-CLR1404, urine was collected for 14 days post injection. Absorbed dose estimates for target organs were determined using the RADAR method with OLINDA/EXM software. RESULTS: Single administrations of 370 MBq of (131)I-CLR1404 were well tolerated by all subjects. No severe adverse events were reported and no adverse event was dose-limiting. Plasma (127)I-CLR1404 concentrations declined in a bi-exponential manner with a mean t½ value of 822 hours. Mean Cmax and AUC(0-t) values were 72.2 ng/mL and 15753 ng • hr/mL, respectively. An administered activity of approximately 740 MBq is predicted to deliver 400 mSv to marrow. CONCLUSIONS: Preliminary data suggest that (131)I-CLR1404 is well tolerated and may have unique potential as an anti-cancer agent. TRIAL REGISTRATION: ClinicalTrials.gov NCT00925275.


Assuntos
Iodobenzenos/farmacologia , Iodobenzenos/uso terapêutico , Neoplasias/patologia , Neoplasias/radioterapia , Éteres Fosfolipídicos/farmacologia , Éteres Fosfolipídicos/uso terapêutico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Neoplasias/diagnóstico , Radiometria , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Imagem Corporal Total
16.
Phys Med Biol ; 57(6): 1641-57, 2012 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-22398155

RESUMO

We have previously developed a model that provides relative dosimetry estimates for targeted radionuclide therapy (TRT) agents. The whole-body and tumor pharmacokinetic (PK) parameters of this model can be noninvasively measured with molecular imaging, providing a means of comparing potential TRT agents. Parameter sensitivities and noise will affect the accuracy and precision of the estimated PK values and hence dosimetry estimates. The aim of this work is to apply a PK model for TRT to two agents with different magnitudes of clearance rates, NM404 and FLT, explore parameter sensitivity with respect to time and investigate the effect of noise on parameter precision and accuracy. Twenty-three tumor bearing mice were injected with a 'slow-clearing' agent, (124)I-NM404 (n = 10), or a 'fast-clearing' agent, (18)F-FLT (3'-deoxy-3'-fluorothymidine) (n = 13) and imaged via micro-PET/CT pseudo-dynamically or dynamically, respectively. Regions of interest were drawn within the heart and tumor to create time-concentration curves for blood pool and tumor. PK analysis was performed to estimate the mean and standard error of the central compartment efflux-to-influx ratio (k(12)/k(21)), central elimination rate constant (k(el)), and tumor influx-to-efflux ratio (k(34)/k(43)), as well as the mean and standard deviation of the dosimetry estimates. NM404 and FLT parameter estimation results were used to analyze model accuracy and parameter sensitivity. The accuracy of the experimental sampling schedule was compared to that of an optimal sampling schedule found using Cramer-Rao lower bounds theory. Accuracy was assessed using correlation coefficient, bias and standard error of the estimate normalized to the mean (SEE/mean). The PK parameter estimation of NM404 yielded a central clearance, k(el) (0.009 ± 0.003 h(-1)), normal body retention, k(12)/k(21) (0.69 ± 0.16), tumor retention, k(34)/k(43) (1.44 ± 0.46) and predicted dosimetry, D(tumor) (3.47 ± 1.24 Gy). The PK parameter estimation of FLT yielded a central elimination rate constant, k(el) (0.050 ± 0.025 min(-1)), normal body retention, k(12)/k(21) (2.21 ± 0.62) and tumor retention, k(34)/k(43) (0.65 ± 0.17), and predicted dosimetry, D(tumor) (0.61 ± 0.20 Gy). Compared to experimental sampling, optimal sampling decreases the dosimetry bias and SEE/mean for NM404; however, it increases bias and decreases SEE/mean for FLT. For both NM404 and FLT, central compartment efflux rate constant, k(12), and central compartment influx rate constant, k(21), possess mirroring sensitivities at relatively early time points. The instantaneous concentration in the blood, C(0), was most sensitive at early time points; central elimination, k(el), and tumor efflux, k(43), are most sensitive at later time points. A PK model for TRT was applied to both a slow-clearing, NM404, and a fast-clearing, FLT, agents in a xenograft murine model. NM404 possesses more favorable PK values according to the PK TRT model. The precise and accurate measurement of k(12), k(21), k(el), k(34) and k(43) will translate into improved and precise dosimetry estimations. This work will guide the future use of this PK model for assessing the relative effectiveness of potential TRT agents.


Assuntos
Didesoxinucleosídeos/farmacocinética , Modelos Biológicos , Fosforilcolina/análogos & derivados , Compostos Radiofarmacêuticos/farmacocinética , Radioterapia/métodos , Animais , Fenômenos Biofísicos , Didesoxinucleosídeos/uso terapêutico , Radioisótopos de Flúor/farmacocinética , Radioisótopos de Flúor/uso terapêutico , Humanos , Radioisótopos do Iodo/farmacocinética , Radioisótopos do Iodo/uso terapêutico , Camundongos , Camundongos Nus , Modelos Estatísticos , Imagem Multimodal , Neoplasias Experimentais/diagnóstico por imagem , Neoplasias Experimentais/metabolismo , Neoplasias Experimentais/radioterapia , Fosforilcolina/farmacocinética , Fosforilcolina/uso terapêutico , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/uso terapêutico , Radioterapia/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Tomografia Computadorizada por Raios X , Proteína Tumoral 1 Controlada por Tradução , Microtomografia por Raio-X
17.
Phys Med Biol ; 55(19): 5723-34, 2010 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-20826898

RESUMO

Biologically effective dose (BED) may be more of a relevant quantity than absorbed dose for establishing tumour response relationships. By taking into account the dose rate and tissue-specific parameters such as repair and radiosensitivity, it is possible to compare the relative biological effects of different targeted radionuclide therapy (TRT) agents. The aim of this work was to develop an analytical tumour BED calculation for TRT that could predict a relative biological effect based on normal body and tumour pharmacokinetics. This work represents a step in the direction of establishing relative pharmacokinetic criteria of when the BED formalism is more applicable than absorbed dose for TRT. A previously established pharmacokinetic (PK) model for TRT was used and adapted into the BED formalism. An analytical equation for the protraction factor, which incorporates dose rate and repair rate, was derived. Dose rates within the normal body and tumour were related to the slopes of their time-activity curves which were determined by the ratios of their respective PK parameters. The relationships between the tumour influx-to-efflux ratio (k(34):k(43)), central compartment efflux-to-influx ratio (k(12):k(21)), central elimination (k(el)), and tumour repair rate (µ), and tumour BED were investigated. As the k(34):k(43) ratio increases and the k(12):k(21) ratio decreases, the difference between tumour BED and D increases. In contrast, as the k(34):k(43) ratios decrease and the k(12):k(21) ratios increase, the tumour BED approaches D. At large k(34):k(43) ratios, the difference between tumour BED and D increases to a maximum as k(el) increases. At small k(34):k(43) ratios, the tumour BED approaches D at very small k(el). At small µ and small k(34):k(43) ratios, the tumour BED approaches D. For large k(34):k(43) ratios, large µ values cause tumour BED to approach D. This work represents a step in the direction of establishing relative PK criteria of when the BED formalism is more applicable than absorbed dose for TRT. It also provides a framework by which the biological effects of different TRT agents can be compared in order to predict efficacy.


Assuntos
Modelos Biológicos , Radioisótopos/farmacocinética , Radioisótopos/uso terapêutico , Neoplasias/metabolismo , Neoplasias/radioterapia , Eficiência Biológica Relativa , Reprodutibilidade dos Testes
18.
Cancer Biother Radiopharm ; 25(4): 417-26, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20735205

RESUMO

Assessment of targeted radionuclide therapy (TRT) agent effectiveness based on its pharmacokinetic (PK) properties could provide means to expedited agent development or its rejection. A broad PK model that predicts the relative effectiveness of TRT agents based on the relationship between their normal body (k(12), k(21)) and tumor (k(34), k(43)) PK parameters has been developed. A classic two-compartment open model decoupled from a tumor was used to represent the body. Analytically solved differential equations were used to develop a relationship that predicts TRT effectiveness. Various PK scenarios were created by pairing normal body PK parameters of 38 pharmaceuticals found in the literature with estimated tumor PK parameters. Each PK scenario resulted in a maximum permissible injected activity that limited the whole-body dose to 2 Gy and yielded a maximum delivered tumor dose. The model suggests that a k(34):k(43) ratio greater than 5 and a k(12):k(21) ratio less than 1 is effective at delivering doses that ensure sufficient solid tumor control. It was also shown that there is no direct relationship between tumor dose and acid dissociation constant (pK(a)), lipophilicity (log P), and fraction unbound (fu), which are important physicochemical properties. This study suggests that although effective TRT may be difficult to achieve for solid tumors, good TRT agents must have extremely desirable normal body PKs in conjunction with very high tumor retention. The developed PK TRT model could serve as a tool to compare the relative dosimetric effectiveness of existing TRT agents and novel TRT agents early in the developmental phase to potentially reject those that possess unfavorable PKs.


Assuntos
Antineoplásicos/uso terapêutico , Modelos Biológicos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Radioimunoterapia , Radiometria , Compostos Radiofarmacêuticos/uso terapêutico , Relação Dose-Resposta a Droga , Humanos , Cintilografia , Eficiência Biológica Relativa , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...