Eye Vis (Lond) ; 10(1): 46, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38037146

RESUMO

BACKGROUND: The shape and microstructure of the human crystalline lens alter with ageing, and this has an effect on the optical properties of the eye. The aim of this study was to characterise the age-related differences in the morphology and transparency of the eye lenses of healthy subjects through the optical signal discontinuity (OSD) zones in optical coherence tomography (OCT) images. We also investigated the association of those changes with the optical quality of the eye and visual function. METHODS: OCT images of the anterior segment of 49 eyes of subjects (9-78 years) were acquired, and the OSD zones (nucleus, C1-C4 cortical zones) were identified. Central thickness, curvature and optical density were measured. The eye's optical quality was evaluated by the objective scatter index (OSI). Contrast sensitivity and visual acuity tests were performed. The correlation between extracted parameters and age was assessed. RESULTS: The increase in lens thickness with age was dominated by the thickening of the cortical zone C3 (0.0146 mm/year). The curvature radii of the anterior lens surface and both anterior and posterior nucleo-cortical interfaces decreased with age (- 0.053 mm/year, - 0.013 mm/year and - 0.006 mm/year, respectively), and no change was observed for the posterior lens radius. OCT-based densitometry revealed significant correlations with age for all zones except for C1ß, and the highest increase in density was in the C2-C4 zones (R = 0.45, 0.74, 0.56, respectively, P < 0.001). Increase in OSI was associated with the degradation of visual function. CONCLUSIONS: OCT enables the identification of OSD zones of the crystalline lens. The most significant age-related changes occur in the C3 zone as it thickens with age at a faster rate and becomes more opaque than other OSD zones. The changes are associated with optical quality deterioration and reduction of visual performance. These findings contribute to a better understanding of the structure-function relationship of the ageing lens and offer insights into both pathological and aging alterations.

2.
Sci Rep ; 12(1): 14834, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050445

RESUMO

Quantitative evaluation of the human corneal grafts stored in the tissue banks is usually limited to endothelial cell density and central thickness. Swept-source OCT (SS-OCT) is capable of measuring the central curvatures of the corneal tissue prepared for transplantation without loss of sterileness, providing insights on its refractive state. The aim of the paper is to compare in vitro SS-OCT measurements with pre-excision values. Hand-held keratometry and ultrasound pachymetry was performed on 22 corneas before excision of corneoscleral button and insertion in the vial with Eusol-C solution (AlchimiaS.r.l, Nicolò, Italy). After 12 to 36 h of hypothermic storage the corneas were examined within the vials with custom built SS-OCT system maintaining a sterile environment. The anterior and posterior central curvatures, and central corneal thickness (CCT) were measured. Rotation of the corneoscleral button was controlled by making a 6-o'clock mark during excision. Mean pre-excision CCT was 626.45 ± 28.71 µm and 468.05 ± 52.96 µm when measured with SS OCT (r = 0.55; p < 0.001). Respective values for average keratometry were 7.74 ± 0.39 mm and 7.92 ± 0.57 mm (r = 0.6; p = 0.22). Although high differences were observed in corneal thickness, keratometric radius of curvature at the flat (r = 0.42; p < 0.001) and steep (r = 0.62; p = 0.014) meridian of the anterior corneal surface, as well as corneal anterior astigmatism (r = 0.3; p < 0.001), showed good correlation with pre-excision values. SS-OCT is capable of providing quantitative evaluation of the human corneal grafts in hypothermic storage. Good correlation between curvature measurements before excision and during banking in the vial indicates its clinical utility.


Assuntos
Doenças da Córnea , Transplante de Córnea , Córnea/cirurgia , Paquimetria Corneana , Bancos de Olhos , Humanos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
3.
Biomed Opt Express ; 13(4): 2174-2185, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35519252

RESUMO

Cataract is one of the common causes of visual impairment due to opacification of the crystalline lens. Increased intraocular scattering affects the vision of cataract patients by reducing the quality of the retinal image. In this study, an amplitude modulation-based scatter compensation (AM-SC) method is developed to minimize the impact of straylight on the retinal image. The performance of the AM-SC method was quantified by numerical simulations of point spread function and retinal images in the presence of different amounts of straylight. The approach was also experimentally realized in a single-pass system with a digital micro-mirror device used as a spatial amplitude modulator. We showed that the AM-SC method allows to enhance contrast sensitivity in the human eyes in vivo with induced scattering.

4.
Sensors (Basel) ; 21(16)2021 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-34450735

RESUMO

Despite technological progress, we lack a consensus on the method of conducting automated bowel sound (BS) analysis and, consequently, BS tools have not become available to doctors. We aimed to briefly review the literature on BS recording and analysis, with an emphasis on the broad range of analytical approaches. Scientific journals and conference materials were researched with a specific set of terms (Scopus, MEDLINE, IEEE) to find reports on BS. The research articles identified were analyzed in the context of main research directions at a number of centers globally. Automated BS analysis methods were already well developed by the early 2000s. Accuracy of 90% and higher had been achieved with various analytical approaches, including wavelet transformations, multi-layer perceptrons, independent component analysis and autoregressive-moving-average models. Clinical research on BS has exposed their important potential in the non-invasive diagnosis of irritable bowel syndrome, in surgery, and for the investigation of gastrointestinal motility. The most recent advances are linked to the application of artificial intelligence and the development of dedicated BS devices. BS research is technologically mature, but lacks uniform methodology, an international forum for discussion and an open platform for data exchange. A common ground is needed as a starting point. The next key development will be the release of freely available benchmark datasets with labels confirmed by human experts.


Assuntos
Inteligência Artificial , Gastroenteropatias , Redes Neurais de Computação , Automação , Gastroenteropatias/diagnóstico , Humanos , Som
5.
Sci Rep ; 11(1): 12460, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34127727

RESUMO

The geometry of contact lenses can be altered by wear but determining the changes that occur in soft contact lenses (SCLs) is challenging. This study aimed to investigate the shape alterations of daily disposable SCLs after wear using swept-source optical coherence tomography (SS-OCT). Forty-five eyes with myopia of - 3.00 diopters (D) were enrolled. The participants wore three types of SCLs: hydrogel lens (nesofilcon A) and silicone hydrogel lenses (delefilcon A and stenfilcon A). The SCLs were scanned 3-6 min after lens removal. We found a significant decrease in the SCL anterior curvature: 0.24 ± 0.17 mm for nesofilcon A, 0.44 ± 0.21 mm for delefilcon A, and 0.53 ± 0.29 mm for stenfilcon A. The changes in the anterior curvature of SCLs correlated moderately with the mean corneal keratometry; Pearson's correlation coefficients for nesofilcon A and delefilcon A were 0.57 and 0.52, respectively (P < 0.001). A statistically significant change in the total diameter was observed in SCL made of stenfilcon A (0.39 mm, P < 0.001). To conclude, the central radii of curvature decreased after a wearing period for all three types of daily disposable SCLs to imitate the anterior corneal surface, however, the changes in other geometrical parameters measured with SS-OCT were lens-specific.

6.
Ophthalmic Physiol Opt ; 41(4): 683-690, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33945648

RESUMO

PURPOSE: To measure geometrical changes in the anterior surface of the cornea after wearing silicon hydrogel (SiH) soft contact lenses continuously for 1 week. METHODS: Forty-three eyes with 3.0D of myopia and 22 eyes with 3.0D of hyperopia were enrolled in the prospective, interventional study. All subjects underwent a general eye examination, corneal tomography with wavefront aberration analysis, corneal thickness measurements and epithelial thickness mapping before and after wearing SiH lenses (Acuvue Oasys) for 7 days. RESULTS: No significant changes in average keratometry were observed in either refractive group. In the myopic group, keratometry findings for the flat meridian (K1) and central corneal thickness decreased significantly. After +3.0 D lens wear in the hyperopic group, a significant decrease in epithelial thickness up to 3.19 µm was observed in the central and paracentral cornea, (p < 0.001). In both refractive groups, the largest epithelial thickness increase was seen in the periphery. A decrease in spherical aberration was noted in myopic eyes, while an increase of both higher order corneal aberrations and coma was found in hyperopic subjects. CONCLUSION: Extended wear of SiH lenses results in a significant change in epithelial thickness leading to alteration in the geometry of the anterior surface of the cornea, particularly in hyperopic patients. These epithelial thickness variations lead to changes in the higher order aberrations of the cornea.


Assuntos
Lentes de Contato Hidrofílicas , Silicones , Lentes de Contato Hidrofílicas/efeitos adversos , Córnea , Humanos , Hidrogéis , Estudos Prospectivos
7.
Biomed Opt Express ; 12(3): 1263-1278, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33796352

RESUMO

Whole eye visualization and morphometry are of high relevance in clinical practice. However, most standard ophthalmic OCT instruments are dedicated either to retinal or to anterior segment imaging. We demonstrate a swept source optical coherence tomography system (SS-OCT) that images both the whole anterior segment and the retina alternately using a single source and detector. A pilot population was imaged with the proof of concept prototype. We demonstrate the clinical potential of whole eye OCT screening for the description and early detection of relevant clinical features in the anterior segment and retina of several patients.

8.
Biomed Opt Express ; 12(3): 1529-1542, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33796370

RESUMO

A three-dimensional optical coherence tomography (OCT) crystalline lens imaging method based on oblique scanning and image stitching is presented. The method was designed to increase OCT imaging volume of crystalline lens in vivo. A long-range swept-source (SS)-OCT imaging system, which can measure the entire anterior segment of eye in a single acquisition, is used to acquire one central volume and 4 extra volumes with different angles between optical axis of OCT instrument and the pupillary axis. The volumes are then stitched automatically by developed software. To show its effectiveness and verify its validity, we scanned the subjects before and after pupil dilation drops and compared the experimental results. By determining the number of voxels representing the signal from the crystalline lens in 3-D OCT images, our method can provide around 17% additional volumetric lens coverage compared with a regular imaging procedure. The proposed approach could be used clinically in early diagnosis of cortical cataract. Wider field of view offered by this method may facilitate more accurate lens biometry in its peripheral zones, which potentially contributes to understanding of lens shape modifications of the accommodating eye.

9.
Invest Ophthalmol Vis Sci ; 62(4): 31, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33929483

RESUMO

Purpose: The purpose of this study was to characterize age-related changes in anterior human vitreous with 3-D swept source optical coherence tomography (SS-OCT) and evaluate associations with axial length (AL) and contrast sensitivity function (CSF). Methods: There were 49 phakic eyes in 49 patients (40.0 ± 19.3 years) had 3-D volumetric scanning of the lens and retrolental vitreous with SS-OCT at 1050 nm. OCT-derived indices of vitreous optical density (VOD), vitreous opacification ratio (VOR), and lens optical density (LOD) were correlated with AL and double-pass assessment of retinal point spread function (Objective Scatter Index [OSI]). CSF was measured using an adaptive-optics visual simulator (area under log-log contrast sensitivity function [AULCSF]). Results: Vitreous SS-OCT detected gel vitreous, liquefied lacunae, Berger's space, retrolental laminae, and fibrous opacifications. VOD, VOR, and LOD showed high reproducibility (intraclass correlation coefficients 0.968, 0.975, and 0.998, respectively). VOD was highly correlated with VOR (Pearson's R = 0.96, P < 0.000001). VOD, VOR, and LOD correlated with age (R = 0.48, 0.58, and 0.85, P < 0.001 for each). VOR and LOD correlated with OSI (R = 0.36, P = 0.0094, and R = 0.36, P = 0.0096, respectively). VOR correlated negatively with AULCSF (R = -0.53, P < 0.00009), which was related to OSI. Myopic eyes had higher OSI than nonmyopic eyes (P = 0.0121), consistent with correlation between OSI and AL (R = 0.37, P = 0.0091). Multivariable regression confirmed these findings. Conclusions: SS-OCT visualized microstructural features of anterior human vitreous, where opacification is associated with increased light scattering and CSF degradation. SS-OCT enables high-resolution optical evaluation of vitreous opacities.


Assuntos
Envelhecimento , Comprimento Axial do Olho/diagnóstico por imagem , Sensibilidades de Contraste/fisiologia , Miopia/diagnóstico , Tomografia de Coerência Óptica/métodos , Corpo Vítreo/diagnóstico por imagem , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Humanos , Cristalino/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Reprodutibilidade dos Testes , Adulto Jovem
10.
PLoS One ; 15(11): e0242095, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33166364

RESUMO

Contact lens wear causes mutual interactions between the ocular surface and the lens, which may affect comfort as well as vision. The aim of this study was to examine deformations in modern positive- and negative-powered silicone hydrogel soft contact lenses (SiH SCLs) after 7 days of continuous wear. This pre-post interventional study included 64 eyes: 42 eyes with myopia of -3.00 D and 22 eyes with hyperopia of +3.00 D. All patients underwent general ophthalmic examination, corneal topography/tomography, total corneal and epithelial thickness mapping, and specular microscopy before and after the wearing period. SiH SCLs made of senofilcon A were worn continuously for 7 days on all eligible eyes. The geometry of the new and used lenses was measured 3 to 6 minutes after removal in two perpendicular planes using a custom-made swept source optical coherence tomography (SS-OCT) system for in vitro measurements. The anterior and posterior radii of curvature decreased in -3.00 D lenses in two perpendicular planes. This effect correlated significantly with average keratometry of the cornea. Sagittal lens height was lower in +3.00 D lens after wear, which correlated moderately with the corneal sagittal height. A significant decrease in central corneal epithelial thickness was observed after wearing +3.0 D lenses. In conclusion, SiH SCLs made of senofilcon A undergo minor deformations after 7-day continuous wear. Geometry modifications are different for -3.00 D and +3.00 D lenses, and they imitate the shape of the anterior eye surface. These geometric changes are accompanied by a decrease in the central thickness of corneal epithelium after +3.00 D lens wear.


Assuntos
Lentes de Contato de Uso Prolongado/normas , Adulto , Lentes de Contato de Uso Prolongado/efeitos adversos , Córnea/efeitos dos fármacos , Córnea/fisiologia , Feminino , Humanos , Hidrogéis/efeitos adversos , Hidrogéis/química , Hidrogéis/normas , Masculino , Silicones/efeitos adversos , Silicones/química , Silicones/normas , Estresse Mecânico
11.
Biomed Opt Express ; 11(10): 5388-5400, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33149958

RESUMO

We demonstrate in vivo three-dimensional (3-D) visualization of crystalline lens sutures in healthy eyes using swept source optical coherence tomography (SS-OCT). Volumetric data sets of the crystalline lenses were acquired and processed to obtain enhanced contrast projection images and to extract suture patterns in both anterior and posterior lens. The results presented different types of the sutures including Y-sutures, simple and complex star sutures. Age-related changes in suture arrangement were characterized quantitatively. Crystalline lens suture imaging with SS-OCT might be a useful tool in fundamental studies on development and ageing of human lens.

13.
Biomed Opt Express ; 10(7): 3663-3680, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31467798

RESUMO

We demonstrate a swept source OCT-based ocular biometer integrated with an air-puff stimulus to study the reaction of the eye to mechanical stimulation in vivo. The system enables simultaneous measurement of the stimulus strength and high-speed imaging of the eye dynamics along the visual axis. We characterize the stimulus and perform optimization of the data acquisition for a proper interpretation of the results. Access to the dynamics of axial eye length allows for a determination of the eye retraction, which is used to correct the air-puff induced displacement of ocular structures. We define the parameters to quantify the reaction of the eye to the air puff and determine their reproducibility in a group of healthy subjects. We observe the corneal deformation process and axial wobbling of the crystalline lens. OCT biometer combined with the air puff is the first instrument with the potential to provide comprehensive information on the biomechanics of ocular components.

14.
Invest Ophthalmol Vis Sci ; 60(6): 1979-1986, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31050724

RESUMO

Purpose: To analyze the dynamics of all optical components of the eye and the behavior of the eyeball under air-puff conditions in vivo. To determine the impact of the intraocular pressure (IOP) on the air-puff-induced deformation of the eye. Methods: Twenty eyes of 20 healthy subjects were included in this study. The dynamics of the ocular components, such as the cornea, the crystalline lens, and the retina, was measured by a prototype swept source optical coherence tomography biometer integrated with the air-puff system. The system allows to acquire a series of axial scans at the same location as a function of time with no transverse scanning. Several parameters were extracted from optical coherence tomography data. The IOP was measured using a Goldmann applanation tonometry. The measurements of the eyes were performed before and 2 hours after administration of IOP-reducing drops, namely, 0.2 % brimonidine tartrate. Results: There is a statistically significant correlation of corneal thickness, vitreous depth, and eye length with IOP. The deformation amplitudes of the cornea and the crystalline lens are inversely proportional to the IOP, but statistical significance is achieved only for the cornea. The crystalline lens is displaced without compression, and the return has the form of wobbling. The reduction of IOP level induces corresponding changes in the extracted parameters. Conclusions: Optical biometry combined with air puff provides comprehensive information on the in vivo behavior of all ocular components, including the crystalline lens. Measurement of the axial length dynamics of during deformation enables correcting the deformation for eye retraction.


Assuntos
Comprimento Axial do Olho/anatomia & histologia , Biometria/métodos , Córnea/anatomia & histologia , Pressão Intraocular/fisiologia , Cristalino/anatomia & histologia , Adulto , Ar , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica , Tonometria Ocular , Corpo Vítreo/anatomia & histologia , Adulto Jovem
15.
J Biophotonics ; 12(2): e201800154, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30239154

RESUMO

Application of the air-puff swept source optical coherence tomography (SS-OCT) instrument to determine the influence of viscoelasticity on the relation between overall the air-puff force and corneal apex displacement of porcine corneas ex vivo is demonstrated. Simultaneous recording of time-evolution of the tissue displacement and air pulse stimulus allows obtaining valuable information related in part to the mechanical properties of the cornea. A novel approach based on quantitative analysis of the corneal hysteresis of OCT data is presented. The corneal response to the air pulse is assessed for different well-controlled intraocular pressure (IOP) levels and for the progression of cross-linking-induced stiffness of the cornea. Micrometer resolution, fast acquisition and noncontact character of the air-puff SS-OCT measurements have potential to improve the in vivo assessment of mechanical properties of the human corneas.


Assuntos
Ar , Córnea/diagnóstico por imagem , Elasticidade , Tomografia de Coerência Óptica , Animais , Fenômenos Biomecânicos , Córnea/fisiologia , Pressão Intraocular , Suínos , Viscosidade
16.
Biomed Opt Express ; 9(8): 3821-3833, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30338158

RESUMO

We demonstrate an optimized optical platform for the three-dimensional (3-D) visualization of crystalline lens opacities in vivo in the eyes of patients with different types and grades of cataracts. We developed a prototype long-depth-range swept source optical coherence tomography (SS-OCT) instrument operating at the speed of 50 kA-scans/second and at the central wavelength of 1 µm to perform high-resolution imaging of the whole anterior segment of the eye. Volumetric data sets of cataractous eyes were acquired and processed to obtain contrast-enhanced high-resolution images of lenticular structures and opacifications. The results showed lens micro- and macro-scale features related to possible cataract development such as cortical spokes, water clefts and enhanced scattering in the lens nucleus. The results demonstrate also the ability of this SS-OCT imaging to locate and characterize opacities quantitatively. The instrument might be a useful tool in the high-resolution preoperative evaluation of crystalline lens opacities in cataract patients.

17.
Appl Opt ; 57(10): C14-C18, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29714267

RESUMO

We demonstrate the application of focus-tunable acousto-optic lens technology in confocal microscopy for a high-speed axial scanning of the object. The advantages of the proposed approach include high axial scan rate, no mechanical sample movement, no additional non-symmetric aberrations, and the control of the effective depth of focus. The acousto-optic lens operating at the focus tuning rate of 300 kHz is developed and implemented in scanning laser confocal microscopy. The performance of the instrumentation is presented using test targets. Rapid focus tuning may enhance in vivo three-dimensional imaging in confocal microscopy.

18.
Sci Rep ; 8(1): 7281, 2018 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-29740064

RESUMO

The lamina cribrosa is a primary site of damage in glaucoma. While mechanical distortion is hypothesized to cause reduction of axoplasmic flow, little is known about how the pores, which contains the retinal ganglion cell axons, traverse the lamina cribrosa. We investigated lamina cribrosa pore paths in vivo to quantify differences in tortuosity of pore paths between healthy and glaucomatous eyes. We imaged 16 healthy, 23 glaucoma suspect and 48 glaucomatous eyes from 70 subjects using a swept source optical coherence tomography system. The lamina cribrosa pores were automatically segmented using a previously described segmentation algorithm. Individual pore paths were automatically tracked through the depth of the lamina cribrosa using custom software. Pore path convergence to the optic nerve center and tortuosity was quantified for each eye. We found that lamina cribrosa pore pathways traverse the lamina cribrosa closer to the optic nerve center along the depth of the lamina cribrosa regardless of disease severity or diagnostic category. In addition, pores of glaucoma eyes take a more tortuous path through the lamina cribrosa compared to those of healthy eyes, suggesting a potential mechanism for reduction of axoplasmic flow in glaucoma.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Fibras Nervosas/patologia , Nervo Óptico/fisiopatologia , Células Ganglionares da Retina/patologia , Idoso , Transporte Axonal/fisiologia , Axônios/patologia , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/fisiologia , Hipertensão Ocular/fisiopatologia , Disco Óptico/diagnóstico por imagem , Disco Óptico/fisiopatologia , Nervo Óptico/diagnóstico por imagem , Tomografia de Coerência Óptica
19.
Invest Ophthalmol Vis Sci ; 59(2): 897-903, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29435589

RESUMO

Purpose: To image, describe, and characterize different features visible in the crystalline lens of older adults with and without cataract when imaged three-dimensionally with a swept-source optical coherence tomography (SS-OCT) system. Methods: We used a new SS-OCT laboratory prototype designed to enhance the visualization of the crystalline lens and imaged the entire anterior segment of both eyes in two groups of participants: patients scheduled to undergo cataract surgery, n = 17, age range 36 to 91 years old, and volunteers without visual complains, n = 14, age range 20 to 81 years old. Pre-cataract surgery patients were also clinically graded according to the Lens Opacification Classification System III. The three-dimensional location and shape of the visible opacities were compared with the clinical grading. Results: Hypo- and hyperreflective features were visible in the lens of all pre-cataract surgery patients and in some of the older adults in the volunteer group. When the clinical examination revealed cortical or subcapsular cataracts, hyperreflective features were visible either in the cortex parallel to the surfaces of the lens or in the posterior pole. Other type of opacities that appeared as hyporeflective localized features were identified in the cortex of the lens. The OCT signal in the nucleus of the crystalline lens correlated with the nuclear cataract clinical grade. Conclusions: A dedicated OCT is a useful tool to study in vivo the subtle opacities in the cataractous crystalline lens, revealing its position and size three-dimensionally. The use of these images allows obtaining more detailed information on the age-related changes leading to cataract.


Assuntos
Catarata/diagnóstico por imagem , Imageamento Tridimensional/métodos , Cristalino/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Extração de Catarata , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Acuidade Visual , Adulto Jovem
20.
Invest Ophthalmol Vis Sci ; 58(3): 1751-1757, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28324116

RESUMO

Purpose: Evaluation of the effect of prelaminar tissue thickness on visualization of the lamina cribrosa (LC) using optical coherence tomography (OCT). Methods: The optic nerve head (ONH) region was scanned using OCT. The quality of visible LC microstructure was assessed subjectively using a grading system and objectively by analyzing the signal intensity of each scan's superpixel components. Manual delineations were made separately and in 3-dimensions quantifying prelaminar tissue thickness, analyzable regions of LC microstructure, and regions with a visible anterior LC (ALC) boundary. A linear mixed effect model quantified the association between tissue thickness and LC visualization. Results: A total of 17 healthy, 27 glaucoma suspect, and 47 glaucomatous eyes were included. Scans with thicker average prelaminar tissue measurements received worse grading scores (P = 0.007), and superpixels with low signal intensity were associated significantly with regions beneath thick prelaminar tissue (P < 0.05). The average prelaminar tissue thickness in regions of scans where the LC was analyzable (214 µm) was significantly thinner than in regions where the LC was not analyzable (569 µm; P < 0.001). Healthy eyes had significantly thicker average prelaminar tissue measurements than glaucoma or glaucoma suspect eyes (both P < 0.001), and glaucoma suspect eyes had significantly thicker average prelaminar tissue measurements than glaucoma eyes (P = 0.008). Significantly more of the ALC boundary was visible in glaucoma eyes (63% of ONH) than in healthy eyes (41%; P = 0.005). Conclusions: Thick prelaminar tissue was associated with impaired visualization of the LC. Healthy subjects generally had thicker prelaminar tissue, which potentially could create a selection bias against healthy eyes when comparing LC structures.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Feminino , Seguimentos , Glaucoma/complicações , Glaucoma/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Doenças do Nervo Óptico/etiologia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença