Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(11)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37947499

RESUMO

We present an ultra-sensitive continuous wave cavity ringdown spectroscopy (cw-CRDS) spectrometer to record high resolution spectra of reactive radicals and ions in a pulsed supersonic plasma. The spectrometer employs a home-made external cavity diode laser as the tunable light source, with its wavelength modulated by radio-frequency white noise. The ringdown cavity with a finesse of ∼105 is arranged with an off-axis alignment. The combination of the off-axis cavity and the white-noise perturbed laser yields quasi-continuum laser-cavity coupling without the need of mode matching. The cavity is further incorporated with an extra multi-pass cavity for optical re-injection of light reflected off the master cavity, which significantly increases the throughput power of the high-finesse cavity. A fast switchable semiconductor optical amplifier is used to modulate the cw laser beam to square wave pulses and to initialize timing controlled ringdown events, which are synchronized to the plasma pulses with an accuracy of ∼3 µs. The performance and potential of the cw-CRDS spectrometer are illustrated and discussed, based on the high resolution near-infrared spectroscopic detection of trace 13C13C radicals generated in a pulsed supersonic C2H2/Ar plasma with a pulse duration of ∼50 µs.

2.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37676085

RESUMO

We present a BaGa4Se7 (BGSe) crystal based coherent pulsed light source for high resolution mid-infrared (MIR) spectroscopy in the 4-12 µm region. The all-solid-state system consists of an injection seeded optical parametric generator (OPG) and an optical parametric amplifier (OPA) using two KTiOPO4 crystals. The idler output of OPG-OPA and the fundamental output (1064 nm) of a wavelength stabilized Nd:YAG laser are employed for difference frequency generation of MIR pulses in the BGSe crystal. Pulsed MIR radiation in the 4-12 µm range is obtained with typical pulse energies higher than 100 µJ and pulse durations of ∼5 ns. By measuring H2O absorption lines in the 8 µm region with this MIR light source and a cavity ring-down spectrometer, the linewidth of the MIR source is inferred as 120 ± 10 MHz, which is very close to the Fourier-transform limited linewidth of 5 ns laser pulses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...