Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hand Surg Am ; 15(2): 335-9, 1990 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2324467

RESUMO

Electromyography was done in patients at the C6 level of quadriplegia after transfer of the brachioradialis to the flexor pollicis longus to restore lateral pinch and transfer of the posterior deltoid to the triceps to restore elbow extension. The relationship of the integrated electromyogram to pinch force during a graduated isometric contraction enabled characterization of the motor recruitment pattern. After tendon transfer, the pattern of the electromyographic response for the brachioradialis was the same as in the flexor pollicis longus in normal subjects, and the posterior deltoid after transfer to the triceps fired synergistically with the brachioradialis. These findings indicate reeducation of transferred muscles occurred after surgery and that they functioned as active primary motors.


Assuntos
Músculos/cirurgia , Quadriplegia/reabilitação , Transferência Tendinosa/métodos , Adulto , Cotovelo/fisiopatologia , Eletromiografia/métodos , Feminino , Humanos , Contração Isométrica/fisiologia , Masculino , Músculos/fisiologia , Cuidados Pós-Operatórios/métodos , Punho/fisiopatologia
2.
Clin Nucl Med ; 13(4): 229-36, 1988 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3163533

RESUMO

Twenty-two painful hip prostheses were studied prospectively with plain radiography, aspiration and arthrography, Tc-99m phosphate bone imaging, and gallium imaging to evaluate loosening, infection, or both and to compare the accuracy of these modalities. Fifteen prostheses were revised yielding 14 loose femoral and eight loose acetabular components. Five proved to have infected prostheses. Arthrograms, plain radiographs, and bone scans are highly sensitive in detecting loosening of the femoral component. This study confirmed a previous retrospective study in demonstrating that accuracy of diagnosis of an abnormal acetabular component using all four modalities is less than that for the femoral component. In infected prostheses, phosphate bone imaging showed high sensitivity of a pattern that accurately diagnosed all the infected cases, whereas gallium imaging missed one case.


Assuntos
Radioisótopos de Gálio , Prótese de Quadril , Dor/etiologia , Fosfatos , Compostos de Tecnécio , Tecnécio , Adulto , Idoso , Artrografia , Infecções Bacterianas/complicações , Infecções Bacterianas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Falha de Prótese , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...