Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36995404

RESUMO

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Sistema de Registros , Fatores de Tempo , Estudos Retrospectivos
2.
Ann Thorac Surg ; 116(1): 86-93, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36481325

RESUMO

BACKGROUND: Early postoperative catheterizations (EPOCs) within 6 weeks after a congenital heart surgical procedure can treat residual lesions and provide important clinical information. However, EPOCs are often assumed to impose additional risk on a vulnerable patient population. This study aimed to describe the EPOC population, evaluate procedural safety, compare EPOC patients with procedure-matched non-EPOC patients, and determine risk factors for poor outcomes using data from the Congenital Cardiac Catheterization Project on Outcomes registry. METHODS: In a retrospective cohort, demographic, clinical, and procedural characteristics were analyzed for diagnostic and interventional catheterizations performed in 13 participating institutions from January 2014 to December 2017, excluding patients after heart transplant. The primary outcome was a high-severity adverse event (AE). Three distinct analyses included (1) describing the full cohort and EPOC patients, (2) comparing EPOC patients with and without a high-severity AE, and (3) comparing EPOC patients with controls matched on case type. RESULTS: This study included 17,776 catheterizations, with 1399 EPOCs. The high-severity AE rate was 6.4% overall, 8.9% in the EPOC cohort, and 8.4% in matched controls (P = .74). The association between EPOC status and high-severity AE was not significant in a multivariable model (P = .17). In EPOCs with a high-severity AE, median procedure duration was 30 minutes longer (P < .001), and median time from surgical procedure to catheterization was 3 days longer (P = .05). CONCLUSIONS: EPOC was not associated with additional risk. Individual patient characteristics of size and hemodynamic vulnerability may serve as informative predictors. Timely catheterization may preempt further clinical deterioration, and intraprocedure duration optimization may correlate with improved outcomes.


Assuntos
Cardiopatias Congênitas , Humanos , Estudos Retrospectivos , Cardiopatias Congênitas/diagnóstico , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica
3.
JACC Adv ; 1(5): 100143, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36471862

RESUMO

Background: The COVID-19 pandemic has posed tremendous stress on the health care system. Its effects on pediatric/congenital catheterization program practice and performance have not been described. Objectives: The purpose of this study was to evaluate how case volumes, risk-profile, and outcomes of pediatric/congenital catheterization procedures changed in response to the first wave of COVID-19 and after that wave. Methods: A multicenter retrospective observational study was performed using Congenital Cardiac Catheterization Project on Outcomes Registry (C3PO) data to study changes in volume, case mix, and outcomes (high-severity adverse events [HSAEs]) during the first wave of COVID (March 1, 2020, to May 31, 2020) in comparison to the period prior to (January 1, 2019, to February 28, 2020) and after (June 1, 2020, to December 31, 2020) the first wave. Multivariable analyses adjusting for case type, hemodynamic vulnerability, and age group were performed. Hospital responses to the first wave were captured with an electronic study instrument. Results: During the study period, 12,557 cases were performed at 14 C3PO hospitals (with 8% performed during the first wave of COVID and 32% in the postperiod). Center case volumes decreased from a median 32.1 cases/month (IQR: 20.7-49.0 cases/month) before COVID to 22 cases/month (IQR: 13-31 cases/month) during the first wave (P = 0.001). The proportion of cases with risk factors for HSAE increased during the first wave, specifically proportions of infants and neonates (P < 0.001) and subjects with renal insufficiency (P = 0.02), recent cardiac surgery (P < 0.001), and a higher hemodynamic vulnerability score (P = 0.02). The observed HSAE risk did not change significantly (P = 0.13). In multivariable analyses, odds of HSAE during the first wave of COVID (odds ratio: 0.75) appeared to be lower than that before COVID, but the difference was not significant (P = 0.09). Conclusions: Despite increased case-mix complexity, C3PO programs maintained, if not improved, their performance in terms of HSAE. Exploratory analyses of practice changes may inform future harm-reduction efforts.

4.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34743224

RESUMO

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Assuntos
Comunicação Interatrial , Exposição à Radiação , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/métodos , Fluoroscopia/métodos , Comunicação Interatrial/cirurgia , Humanos , Melhoria de Qualidade , Doses de Radiação , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
6.
Front Pediatr ; 9: 679572, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34195162

RESUMO

Background: Pulmonary arteriovenous malformations (PAVMs) are common sequelae of palliated univentricular congenital heart disease, yet their pathogenesis remain poorly defined. In this preliminary study, we used paired patient blood samples to identify potential hepatic factor candidates enriched in hepatic vein blood. Methods: Paired venous blood samples were collected from the hepatic vein (HV) and superior vena cava (SVC) from children 0 to 10 years with univentricular and biventricular congenital heart disease (n = 40). We used three independent protein analyses to identify proteomic differences between HV and SVC blood. Subsequently, we investigated the relevance of our quantified protein differences with human lung microvascular endothelial assays. Results: Two independent protein arrays (semi-quantitative immunoblot and quantitative array) identified that soluble vascular endothelial growth factor receptor 1 (sVEGFR1) is significantly elevated in HV serum compared to SVC serum. Using ELISA, we confirmed the previous findings that sVEGFR1 is enriched in HV serum (n = 24, p < 0.0001). Finally, we studied the quantified HV and SVC serum levels of sVEGFR1 in vitro. HV levels of sVEGFR1 decreased tip cell selection (p = 0.0482) and tube formation (fewer tubes [p = 0.0246], shorter tube length [p = 0.0300]) in vitro compared to SVC levels of sVEGFR1. Conclusions: Based on a small heterogenous cohort, sVEGFR1 is elevated in HV serum compared to paired SVC samples, and the mean sVEGFR1 concentrations in these two systemic veins cause pulmonary endothelial phenotypic differences in vitro. Further research is needed to determine whether sVEGFR1 has a direct role in pulmonary microvascular remodeling and PAVMs in patients with palliated univentricular congenital heart disease.

7.
Semin Thorac Cardiovasc Surg ; 32(4): 980-987, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32387780

RESUMO

To improve our understanding of pulmonary arteriovenous malformations in univentricular congenital heart disease, our objective was to identify the effects of hepatic vein and superior vena cava constituents on lung microvascular endothelial cells independent of blood flow. Paired blood samples were collected from the hepatic vein and superior vena cava in children 0-10 years old undergoing cardiac catheterization. Isolated serum was subsequently used for in vitro endothelial cell assays. Angiogenic activity was assessed using tube formation and scratch migration. Endothelial cell survival was assessed using proliferation (BrdU incorporation, cell cycle analysis) and apoptosis (caspase 3/7 activity, Annexin-V labeling). Data were analyzed using Wilcoxon signed-rank test and repeated measures analysis. Upon incubating lung microvascular endothelial cells with 10% patient serum, hepatic vein serum increases angiogenic activity (tube formation, P = 0.04, n = 24; migration, P< 0.001, n = 18), increases proliferation (BrdU, P < 0.001, n = 32; S-phase, P = 0.04, n = 13), and decreases apoptosis (caspase 3/7, P < 0.001, n = 32; Annexin-V, P = 0.04, n = 12) compared to superior vena cava serum. Hepatic vein serum regulates lung microvascular endothelial cells by increasing angiogenesis and survival in vitro. Loss of hepatic vein serum signaling in the lung microvasculature may promote maladaptive lung microvascular remodeling and pulmonary arteriovenous malformations.


Assuntos
Técnica de Fontan , Veias Hepáticas , Criança , Pré-Escolar , Células Endoteliais , Veias Hepáticas/diagnóstico por imagem , Veias Hepáticas/cirurgia , Humanos , Lactente , Recém-Nascido , Pulmão , Veia Cava Inferior/cirurgia , Veia Cava Superior
8.
J Am Coll Cardiol ; 75(4): 363-376, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-32000947

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) is associated with a risk of procedural serious adverse events (SAE) and exposure to ionizing radiation. OBJECTIVES: The purpose of this study was to define the risk of, and associations with, SAE and high-dose radiation exposure using large-scale registry data. METHODS: The analysis of the multicenter C3PO-QI registry was limited to patients who underwent TPVR from January 1, 2014, to December 31, 2016. SAE were defined as the occurrence of ≥1 moderate, major, or catastrophic events. Radiation dose was reported as dose area product adjusted for weight. Associations with outcome measures were explored in univariate and multivariable analyses. RESULTS: A total of 530 patients (59% male) underwent TPVR at a median age of 18.3 years (interquartile range [IQR]: 12.9 to 27.3 years) and weight of 58 kg (IQR: 43 to 77 kg) at 14 centers. Implant substrate included homograft (41%), bioprosthesis (30%), native right ventricular outflow tract (RVOT) (27%) and other (2%). TPVR indications were pulmonary insufficiency (28%), stenosis (23%), and mixed (49%). AE and SAE occurred in 26% and 13% of cases, respectively, including 1 mortality. SAE were more frequent in homograft conduit than other RVOT substrates, although SAE type and severity differed between implant substrates. Median radiation dose was 198 µGy·m2/kg (IQR: 94 to 350 µGy·m2/kg). Higher radiation dose was associated with older age, greater RVOT obstruction, and concomitant interventions (p < 0.001). During a median follow-up duration of 1 year, 13.3% underwent catheterization, surgery, or both, unrelated to infection. Younger age, smaller size, and hemodynamic and anatomic factors indicative of greater RVOT obstruction were associated with TPV reintervention. CONCLUSIONS: The incidence of SAE during TPVR in the C3PO-QI registry is high, but mortality is uncommon. Radiation dose is greater than for other congenital interventions and is associated with patient and procedural factors. Reintervention is common during early follow-up.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Exposição à Radiação , Radiação Ionizante , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cateterismo , Criança , Endocardite/cirurgia , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Incidência , Masculino , Análise Multivariada , Sistema de Registros , Risco , Tetralogia de Fallot/cirurgia , Adulto Jovem
9.
BMJ Case Rep ; 12(12)2019 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-31811104

RESUMO

A previously healthy, preadolescent female suffered an unwitnessed cardiac arrest with prompt return of circulation following bystander initiated resuscitation. Workup demonstrated the cause of her cardiac arrest to be distal left anterior descending coronary artery occlusion with small apical left ventricular transmural myocardial infarction, from a paradoxical embolus traversing a previously undiagnosed large sinus venous defect. This case demonstrates the value of cardiac magnetic resonance imaging may bring to the diagnosis of the pathophysiology leading to cardiac arrest.


Assuntos
Embolia Paradoxal/diagnóstico , Parada Cardíaca/etiologia , Comunicação Interatrial/diagnóstico , Reanimação Cardiopulmonar , Criança , Angiografia Coronária , Diagnóstico Diferencial , Embolia Paradoxal/complicações , Embolia Paradoxal/diagnóstico por imagem , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética
10.
JACC Case Rep ; 1(5): 746-750, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-34316924

RESUMO

We present a patient with a supported Ross procedure and severe pulmonary homograft stenosis who developed cardiac arrest while undergoing transcatheter pulmonary valve replacement and was found to have a large iatrogenic aortopulmonary window. Cardiopulmonary resuscitation was initiated followed by covered stent placement, extracorporeal membrane oxygenation support, and ultimately emergent surgery with a good outcome. (Level of Difficulty: Advanced.).

11.
Pediatr Cardiol ; 40(2): 445-453, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30506273

RESUMO

To stratify diverse procedure types into categories with similar radiation exposure in cardiac catheterization for congenital heart disease. Radiation exposures for a comprehensive list of specific procedure types and stratification of outcomes based on radiation risk are not currently available. Data between January 2014 and December 2015 were collected on all cases performed at sites participating in C3PO-QI (Congenital Cardiac Catheterization Outcomes Project-Quality Improvement Initiative) and 9 centers were included. Using expert consensus, 40 unique procedure types were defined by diagnostic characteristics or the intervention(s) performed, and dose area product (DAP) per kilogram of body weight (µGy × m2/kg) was summarized. Using empiric and consensus methods, three radiation risk categories were created. A total of 11,735 cases were included for analysis. Thirteen (n = 7918) procedure types with median DAP/kg < 100 were categorized in the low radiation exposure category (median DAP/kg 39). The medium exposure category (n = 1807) consisted of 16 procedure types with median DAP/kg values ranging 100 to < 200 (overall median DAP/kg 131). Finally, the high radiation exposure category (n = 1073) consisted of 11 procedure types with median DAP/kg ≥ 200 (overall median DAP/kg of 231). The radiation exposure risk categories created in this multi-center dataset are a critical step towards the development of a robust risk adjustment methodology for radiation exposure in catheterization for congenital heart disease.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Fluoroscopia/efeitos adversos , Cardiopatias Congênitas/cirurgia , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Adolescente , Criança , Pré-Escolar , Consenso , Humanos , Lactente , Estudos Prospectivos , Melhoria de Qualidade , Doses de Radiação , Medição de Risco/métodos , Fatores de Risco , Adulto Jovem
12.
Congenit Heart Dis ; 13(6): 935-943, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30260077

RESUMO

INTRODUCTION: In patients with tetralogy of Fallot (TOF), use of transannular patch (TAP) may be required in order to relieve significant right ventricular outflow tract obstruction, subsequently resulting in pulmonary insufficiency (PI). The monocusp valve has been used to temporarily reduce insufficiency in hopes to improve short and midterm outcomes. The purpose of this study was to assess for potential benefits of the monocusp valve in this subset of patients. DESIGN: Between 2005 and 2016, 119 patients with TOF with pulmonary stenosis who underwent repair with TAP were analyzed, 43 (36.1%) had a monocusp valve placed. Immediate outcomes were assessed by postoperative echocardiograms, ICU data including time to extubation, chest tube duration, reintervention, length of stay, and mortality. RESULTS: Median age of repair was similar for monocusp group at 143.5 days and nonmonocusp at 137.0 days (P = .93). Peak preoperative right ventricular outflow tract obstruction was higher in the monocusp group (80 mm Hg vs. 70 mm Hg, P ≤ .01). Patients who had monocusp placed had longer bypass time. There was less PI for monocusp group immediately after repair and at discharge (P ≤ .01). There was no difference in days of intubation, chest tube duration, length of hospitalization, reintervention rates, or mortality. CONCLUSION: Decreasing the degree of PI with a monocusp valve in patients undergoing repair for TOF repair with TAP does not improve clinical outcomes in the immediate postoperative period.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Próteses Valvulares Cardíacas , Procedimentos de Cirurgia Plástica/métodos , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Ecocardiografia , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Período Pós-Operatório , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/mortalidade , Resultado do Tratamento , Wisconsin/epidemiologia
13.
Catheter Cardiovasc Interv ; 90(2): 269-280, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28198573

RESUMO

OBJECTIVES: This study sought to update benchmark values to use a quality measure prospectively. BACKGROUND: Congenital Cardiac Catheterization Outcomes Project - Quality Improvement (C3PO-QI), a multi-center registry, defined initial radiation dose benchmarks retrospectively across common interventional procedures. These data facilitated a dose metric endorsed by the American College of Cardiology in 2014. METHODS: Data was collected prospectively by 9 C3PO-QI institutions with complete case capture between 1/1/2014 and 6/30/2015. Radiation was measured in total air kerma (mGy), dose area product (DAP) (µGy*M2 ), DAP per body weight, and fluoroscopy time (min), and reported by age group as median, 75th and 95th %ile for the following six interventional procedures: (1) atrial septal defect closure; (2) aortic valvuloplasty; (3) treatment of coarctation of the aorta; (4) patent ductus arteriosus closure; (5) pulmonary valvuloplasty; and (6) transcatheter pulmonary valve implantation. RESULTS: The study was comprised of 1,680 unique cases meeting inclusion criteria. Radiation doses were lowest for pulmonary valvuloplasty (age <1 yrs, median mGy: 59, DAP: 249) and highest in transcatheter pulmonary valve implantation (age >15 yrs, median mGy: 1835, DAP: 17990). DAP/kg standardized outcome measures across weights within an age group and procedure type significantly more than DAP alone. Radiation doses decreased for all procedures compared to those reported previously by both median and median weight-based percentile curves. These differences in radiation exposure were observed without changes in median fluoroscopy time. CONCLUSIONS: This study updates previously established benchmarks to reflect QI efforts over time. These thresholds can be applied for quality measurement and comparison. © 2017 Wiley Periodicals, Inc.


Assuntos
Benchmarking/normas , Cateterismo Cardíaco/normas , Cardiopatias Congênitas/terapia , Pediatria/normas , Doses de Radiação , Exposição à Radiação/normas , Radiografia Intervencionista/normas , Adolescente , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Masculino , Segurança do Paciente/normas , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Estados Unidos
14.
Cardiol Young ; 27(3): 600-604, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27748225

RESUMO

The Melody® transcatheter pulmonary valve system was developed for placement within right ventricle-to-pulmonary artery conduits in patients with CHD for treatment of stenosis or regurgitation, providing an alternative to open-heart surgery. Abnormal systemic venous connections altering the catheter course to the right ventricle-to-pulmonary artery conduit may present a challenge to Melody® valve implantation. We present two such cases, in which the Melody® valve was successfully implanted in teenage patients with congenitally corrected transposition of the great arteries after Senning atrial switch operation. Despite the abnormal catheter course, the right ventricle-to-pulmonary artery was approachable via the right femoral vein allowing for deployment of the Melody® valve in the appropriate position. This suggests that systemic vein-to-left atrium baffles are not prohibitive of Melody® valve implantation. This is an important implication considering the substantial population of ageing patients with CHD who have undergone atrial switch. Melody® valve implantation can be considered as a viable option for treatment of these patients if they develop right ventricle-to-pulmonary artery conduit failure.


Assuntos
Anormalidades Múltiplas , Transposição das Grandes Artérias/métodos , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Transposição dos Grandes Vasos/cirurgia , Adolescente , Angiografia , Feminino , Seguimentos , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Flebografia , Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/congênito , Estenose da Valva Pulmonar/diagnóstico
15.
Pediatr Cardiol ; 37(4): 740-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26846123

RESUMO

Coronary allograft vasculopathy (CAV) is the leading cause of graft failure in pediatric heart transplant recipients, also adding to mortality in this patient population. Coronary angiography is routinely performed to screen for CAV, with conventional single-plane or bi-plane angiography being utilized. Dual-axis rotational coronary angiography (RA) has been described, mostly in the adult population, and may offer reduction in radiation dose and contrast volume. Experience with this in the pediatric population is limited. This study describes a single-institution experience with RA for screening for CAV in pediatric patients. The catheterization database at our institution was used to identify pediatric heart transplant recipients having undergone RA to screen for CAV. Procedural data including radiation dose, fluoroscopy time, contrast volume, and procedure time were collected for each catheterization. The number of instances in which RA was not successful, ECG changes were present, and CAV was detected were also collected for each catheterization. A total of 97 patients underwent 345 catheterizations utilizing RA. Median radiation dose-area product per kilogram was found to be 341.7 (mGy cm(2)/kg), total air kerma was 126.8 (mGy), procedure time was 69 min, fluoroscopy time was 9.9 min, and contrast volume was 13 ml. A total of 17 (2 %) coronary artery injections out of 690 could not be successfully imaged using RA. A total of 14 patients had CAV noted at any point, 10 of whom had progressive CAV. Electrocardiographic changes were documented in a total of 10 (3 %) RA catheterizations. Procedural characteristics did not differ between serial catheterizations. RA is safe and feasible for CAV screening in pediatric heart transplant recipients while offering coronary imaging in multiple planes compared to conventional angiography.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Transplante de Coração , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Fluoroscopia , Rejeição de Enxerto/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Wisconsin , Adulto Jovem
16.
Am J Ther ; 23(6): e1293-e1299, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-25611359

RESUMO

Early treatment with intravenous immunoglobulin (IVIG) is necessary to help reduce the risk of coronary artery abnormalities, such as coronary artery aneurysms and to help alleviate symptoms, in Kawasaki disease. Some patients, however, do not respond to an initial dose of IVIG and require additional doses. Prediction of these IVIG nonresponders may be of assistance in altering initial therapy to make it more effective. The Egami score has been validated in the Japanese population to predict IVIG nonresponders but has shown to be ineffective in US populations. This study evaluates the Egami score in a Midwest US population, subdividing patients by race and the diagnosis of typical or atypical type of Kawasaki disease. Patients were included in the study if they met criteria for Kawasaki disease and received IVIG in the inpatient setting. A total of 182 patients were studied, and in all studied groups, the Egami score had poor sensitivity at predicting IVIG nonresponders. Sensitivity of the score differed between races and differed between typical and atypical Kawasaki disease. The Egami score, as well as other systems, have been validated to predict IVIG nonresponders. These, however, lack sensitivity in the US population. Other scores developed in the United States have also lacked sensitivity, likely due to the absence of race or Kawasaki disease classification as variables. The development of a sensitive scoring system to predict IVIG nonresponders in US populations will require the incorporation of race and Kawasaki disease classification, factors that seem to alter IVIG response.


Assuntos
Imunoglobulinas Intravenosas/uso terapêutico , Fatores Imunológicos/uso terapêutico , Síndrome de Linfonodos Mucocutâneos/tratamento farmacológico , Criança , Pré-Escolar , Resistência a Medicamentos , Etnicidade , Feminino , Humanos , Lactente , Masculino , Síndrome de Linfonodos Mucocutâneos/etnologia , Grupos Raciais , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Estados Unidos
17.
Cardiol Young ; 25(4): 806-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25046031

RESUMO

Antiepileptic medications have been reported to cause disturbances in cardiac conduction. Lacosamide decreases seizure burden by modulating sodium channels. Although it has been demonstrated to have few side effects, there have been reports of clinically significant cardiac conduction disturbances. We report the case of a child with hypoplastic left-heart syndrome and well-controlled multifocal atrial tachycardia who developed haemodynamically significant atrial tachycardia after receiving two doses of lacosamide.


Assuntos
Acetamidas/efeitos adversos , Anticonvulsivantes/efeitos adversos , Taquicardia Sinusal/induzido quimicamente , Anticonvulsivantes/uso terapêutico , Arritmias Cardíacas , Pré-Escolar , Comorbidade , Humanos , Síndrome do Coração Esquerdo Hipoplásico , Isoxazóis/administração & dosagem , Lacosamida , Levetiracetam , Masculino , Piracetam/administração & dosagem , Piracetam/análogos & derivados , Convulsões/tratamento farmacológico , Resultado do Tratamento , Zonisamida
18.
Pediatr Cardiol ; 35(3): 423-30, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24096718

RESUMO

Neonatal tetralogy of Fallot (TOF) repair carries an increased risk of low birthweight or premature infants. Studies are investigating stents in the right ventricular outflow tract (RVOT) as an alternative to aortopulmonary shunts. The authors review their institutional experience with RVOT stenting in the high-risk infant with TOF. Data on sequential patients who received RVOT stents were reviewed, with collection of their surgical, echocardiographic, and catheterization data. Size-matched control subjects were identified and outcomes compared. Six infants went to the catheterization lab for RVOT stenting from 2008 to 2010. Five of these patients had placement of an RVOT stent after balloon dilation. The median saturations were 71% on 48% fraction of inspired oxygen (FiO2), with improvement to 94% (p < 0.001) on 39% FiO2 24 h after stent placement. As shown by echocardiography, the diameter of the median right pulmonary artery (RPA) was 2.6 mm (z-score, -3.3), and the diameter of the left pulmonary artery (LPA) was 2.0 mm (z-score, -4.5). Repeat echocardiography before surgery showed a statistically significant increase in RPA and LPA size as well as a modified McGoon ratio (p < 0.05). Four of the five patients subsequently underwent TOF repair. No stent fractures occurred. One patient had repair 10 days after stent placement secondary to stent malposition and tricuspid valve injury. The authors' experience with stents in the RVOT of TOF patients has yielded good results, with significant improvement in oxygen saturations. Patients had successful elective surgical repair and stent removal without longer cardiopulmonary bypass times or recognizable complications compared with shunted patients.


Assuntos
Stents , Tetralogia de Fallot/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Cateterismo Cardíaco , Cianose/fisiopatologia , Ecocardiografia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/fisiopatologia
19.
Pediatr Cardiol ; 34(3): 560-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22956061

RESUMO

Annual surveillance coronary angiograpyhy to screen for graft coronary vasculopathy is routine practice after orthotopic heart transplantation. Traditionally, this is performed with direct coronary angiography using static single-plane or biplane angiography. Recently, technological advances have made it possible to perform dual-axis rotational coronary angiography (RA). This technique differs from standard static single-plane or biplane angiography in that a single detector is preprogrammed to swing through a complex 80° arc during a single injection. It has the advantage of providing a perspective of the vessels from a full arc of images rather than from one or two static images per contrast injection. The current study evaluated two coronary angiography techniques used consecutively at a single center to evaluate pediatric heart transplant recipients for graft coronary vasculopathy. A total of 23 patients underwent routine coronary angiography using both biplane static coronary angiography (BiP) and RA techniques at the Children's Hospital of Wisconsin from February 2009 to September 2010. Demographic and procedure data were collected from each procedure and analyzed for significance utilizing a Wilcoxon rank sum test. No significant demographic or procedural differences between the BiP and the RA procedures were noted. Specific measures of radiation dose including fluoroscopy time and dose area product were similar among the imaging techniques. The findings show that RA can be performed safely and reproducibly in pediatric heart transplant recipients. Compared with standard BiP, RA does not increase radiation exposure or contrast use and in our experience has provided superior angiographic imaging for the evaluation of graft coronary vasculopathy.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Intensificação de Imagem Radiográfica , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Meios de Contraste , Angiografia Coronária/instrumentação , Feminino , Rejeição de Enxerto/diagnóstico por imagem , Rejeição de Enxerto/patologia , Transplante de Coração/métodos , Hospitais Pediátricos , Humanos , Masculino , Monitorização Fisiológica/métodos , Segurança do Paciente , Doses de Radiação , Reprodutibilidade dos Testes , Medição de Risco , Estatísticas não Paramétricas
20.
J Pediatr Surg ; 47(5): E25-31, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22595606

RESUMO

We report the case of a child with Abernethy malformation with an anomalous connection between the portal vein and the coronary sinus. After 30 months of close follow-up, the patient developed hepatoblastoma, a previously documented complication of the Abernethy malformation. This case reports a unique variant of Abernethy malformation and documents the first reported case of hepatoblastoma in a patient with type 2 Abernethy malformation.


Assuntos
Seio Coronário/anormalidades , Doenças em Gêmeos/diagnóstico , Hepatoblastoma/diagnóstico , Neoplasias Hepáticas/diagnóstico , Veia Porta/anormalidades , Fístula Vascular/diagnóstico , Pré-Escolar , Doenças em Gêmeos/complicações , Doenças em Gêmeos/congênito , Evolução Fatal , Hepatoblastoma/etiologia , Humanos , Lactente , Recém-Nascido , Neoplasias Hepáticas/etiologia , Masculino , Fístula Vascular/complicações , Fístula Vascular/congênito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...