Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39002850

RESUMO

BACKGROUND: Minibeam radiation therapy (MBRT) is characterized by the delivery of submillimeter wide regions of high "peak" and low "valley" doses throughout a tumor. Preclinical studies have long shown the promise of this technique, and we report here the first clinical implementation of MBRT. METHODS: A clinical orthovoltage unit was commissioned for MBRT patient treatments using 3, 4, 5, 8, and 10 cm diameter cones. The 180 kVp output was spatially separated into minibeams using a tungsten collimator with 0.5 mm wide slits spaced 1.1 mm on center. Percentage depth dose (PDD) measurements were obtained using film dosimetry and plastic water for both peak and valley doses. PDDs were measured on central axis for offsets of 0, 0.5, and 1 cm. The peak-to-valley ratio (PVR) was calculated at each depth for all cones and offsets. To mitigate the effects of patient motion on delivered dose, patient-specific 3D printed collimator holders were created. These conformed to the unique anatomy of each patient and affixed the tungsten collimator directly to the body. Two patients were treated with MBRT, both received 2 fractions. RESULTS: Peak PDDs decreased gradually with depth. Valley PDDs initially increased slightly with depth, then decreased gradually beyond 2 cm. PVRs were highest at the surface for smaller cone sizes and offsets. In vivo film dosimetry confirmed a distinct delineation of peak and valley doses on both patients treated with MBRT with no dose blurring. Both patients experienced prompt improvement in symptoms and tumor response. CONCLUSIONS: We report commissioning results, treatment processes, and the first two patients treated with MBRT using a clinical orthovoltage unit. While demonstrating feasibility of this approach is a crucial first step toward wider translation, clinical trials are needed to further establish safety and efficacy.

2.
Adv Radiat Oncol ; 7(6): 101008, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36034194

RESUMO

Purpose: Small bowel tolerance may be dose-limiting in the management of some pelvic and abdominal malignancies with curative-intent radiation therapy. Multiple techniques previously have been attempted to exclude the small bowel from the radiation field, including the surgical insertion of an absorbable mesh to serve as a temporary pelvic sling. This case highlights a clinically meaningful application of this technique with modern radiation therapy. Methods and Materials: A patient with locally invasive, unresectable high-grade sarcoma of the right pelvic vasculature was evaluated for definitive radiation therapy. The tumor immediately abutted the small bowel. The patient underwent laparoscopic placement of a mesh sling to retract the abutting small bowel and subsequently completed intensity modulated proton therapy. Results: The patient tolerated the mesh insertion procedure and radiation therapy well with no significant toxic effects. The combination approach achieved excellent dose metrics, and the patient has no evidence of progression 14 months out from treatment. Conclusions: The combination of mesh as a pelvic sling and proton radiation therapy enabled the application of a curative dose of radiation therapy and should be considered for patients in need of curative-intent radiation when the bowel is in close proximity to the target.

3.
Int J Part Ther ; 9(1): 83-89, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35774492

RESUMO

Sexual dysfunction is a common toxicity and detrimental for the quality of life of women treated with chemoradiotherapy for anal cancer. Sexual dysfunction occurs because the vagina is closely approximated to the anal canal and typically receives substantial doses of radiation. Strategies for mitigation have largely been focused on posttreatment therapy and symptom management. The use of daily vaginal dilator placement during radiotherapy to mitigate dose to the vagina has been previously explored with modest gains, while proton therapy is under active investigation for the treatment of anal cancer. Use of proton therapy for anal cancer reduces dose to some organs at risk but may inadvertently increase vaginal toxicity if the proton beam terminates in the vaginal tissue. Herein, we present the case histories of 2 women treated for squamous cell carcinoma of the anal canal with the novel combination of intensity-modulated proton therapy and daily vaginal dilator placement to maximally reduce dose to the vagina and protect it from areas of increased energy deposition at the end of the proton range.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...