Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 9(2): e13539, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36846650

RESUMO

The paper investigates the mechanical behavior of structural elements of a material extruded component using a multiscale analysis based on a homogenization method. The development and validation of a homogenization model start with designing a tailor-made lattice structure. The material model is described using elastoplastic properties and Hill's yield criterion. The numerical validation of the homogenized model and its comparison with the full detail is also described.

2.
Sensors (Basel) ; 20(3)2020 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-32013208

RESUMO

In this work, we show how miniature step gauges featuring unidirectional and bidirectional lengths can be used to assess the performance of 3D optical scanners as well as the accuracy of novel Additive Manufacturing (AM) processes. A miniature step gauge made of black polyphenylene sulfide (PPS) was used for the performance verification of three different optical scanners: a structured light scanner (SLS), a laser line scanner (LLS), and a photogrammetry-based scanner (PSSRT), having comparable resolutions and working volumes. Results have shown a good agreement between the involved scanners, with errors below 5 µm and expanded uncertainties below 10 µm. The step gauge geometry due to the bidirectional lengths, highlights that there is a different interaction between the optical properties of the step gauge under measurement and each optical instrument involved and this aspect has to be considered in the uncertainty budget. The same geometry, due to its great significance in the detection of systematic errors, was used, as a novelty, to evaluate the accuracy of Lithography-based Ceramics Manufacturing (LCM), a proprietary additive manufacturing technology used for the fabrication of medical implants. In particular, two miniature step gauges made of Tricalcium Phosphate (TCP) were produced. Measurements conducted with the SLS scanner were characterized by a negligible error and by an uncertainty of about 5 µm. Deviations of the manufactured step gauges with respect to the Computer Aided Designed (CAD) model were comprised between ±50 µm, with positive deviations in the order of 100 µm on vertical sides. Differences in the order of 50 µm between the two step gauges were registered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...