Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 406(3): 915-22, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24337134

RESUMO

A novel analytical method using hydrophilic interaction liquid chromatography combined with electrospray tandem mass spectrometry for metabolic profiling of free, underivatized amino acids is presented. The separation uses a zwitterionic modified silica-based stationary phase with 1.8-µm particle size functionalized with ammonium sulfonic acid groups. Quantification is based on external standard calibration using a Pichia pastoris cell extract grown on uniformly (13)C labeled glucose as an internal standard. The absolute limits of detection in the cellular matrix were in the subpicomolar range. Measurement accuracy was assessed by analyzing NIST Standard Reference Material 2389a, which provides certified values for 17 amino acids. The recovery of the amino acids ranged between 65 % (proline) and 120 % (lysine), with excellent repeatability precision below 2.5 % (n = 5). Only, cystine showed poor recovery (29 %) and repeatability precision (13 %). Generally, the long-term precision obtained by hydrophilic interaction liquid chromatography-tandem mass spectrometry was excellent, being on average less than 9 % over 20 h of measurement time. Moreover, the novel separation method had average repeatability and reproducibility of the chromatographic peak width over time periods of 20 h and 6 months of 8 and 15 %, respectively, demonstrating its high robustness in routine analysis of cellular samples. Large concentration differences depending on the amino acid were found in the cell extracts, typically ranging from 0.002 nmol per milligram of cell dry weight (cystine) to 56 nmol per milligram of cell dry weight (arginine and glutamic acid).


Assuntos
Aminoácidos/química , Isótopos de Carbono/análise , Técnicas de Química Analítica/métodos , Cromatografia Líquida , Metaboloma , Espectrometria de Massas em Tandem , Calibragem , Proteínas Fúngicas/química , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Tamanho da Partícula , Padrões de Referência , Reprodutibilidade dos Testes , Fatores de Tempo
2.
Anal Bioanal Chem ; 405(15): 5133-46, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23559335

RESUMO

Metabolic flux analysis implies mass isotopomer distribution analysis and determination of mass isotopologue fractions (IFs) of proteinogenic amino acids of cell cultures. In this work, for the first time, this type of analysis is comprehensively investigated in terms of measurement uncertainty by calculating and comparing budgets for different mass spectrometric techniques. The calculations addressed amino acids of Pichia pastoris grown on 10% uniformly (13)C labeled glucose. Typically, such experiments revealed an enrichment of (13)C by at least one order of magnitude in all proteinogenic amino acids. Liquid chromatography-time-of-flight mass spectrometry (LC-TOFMS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) analyses were performed. The samples were diluted to fit the linear dynamic range of the mass spectrometers used (10 µM amino acid concentration). The total combined uncertainties of IFs as well as the major uncertainty contributions affecting the IFs were determined for phenylalanine, which was selected as exemplary model compound. A bottom-up uncertainty propagation was performed according to Quantifying Uncertainty in Analytical Measurement and using the Monte Carlo method by considering all factors leading to an IF, i.e., the process of measurement and the addition of (13)C-glucose. Excellent relative expanded uncertainties (k = 1) of 0.32, 0.75, and 0.96% were obtained for an IF value of 0.7 by LC-MS/MS, GC-MS, and LC-TOFMS, respectively. The major source of uncertainty, with a relative contribution of 20-80% of the total uncertainty, was attributed to the signal intensity (absolute counts) uncertainty calculated according to Poisson counting statistics, regardless which of the mass spectrometry platforms was used. Uncertainty due to measurement repeatability was of importance in LC-MS/MS, showing a relative contribution up to 47% of the total uncertainty, whereas for GC-MS and LC-TOFMS the average contribution was lower (30 and 15%, respectively). Moreover, the IF actually present also depends on the isotopic purity of the carbon sources. Therefore, in the uncertainty calculation a carbon source purity factor was introduced and a minor contribution to the total uncertainty was observed. The results obtained by uncertainty calculation performed according to the Monte Carlo method were in agreement with the uncertainty value of the Kragten approach and showed a Gaussian distribution.


Assuntos
Aminoácidos/metabolismo , Espectrometria de Massas/métodos , Metabolômica/métodos , Metabolômica/normas , Pichia/metabolismo , Incerteza , Aminoácidos/química , Cromatografia Líquida/métodos , Marcação por Isótopo , Pichia/química , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...