Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Materials (Basel) ; 17(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38893753

RESUMO

In this study, Silicon Carbide (SiC) nanoparticle-based serigraphic printing inks were formulated to fabricate highly sensitive and wide temperature range printed thermistors. Inter-digitated electrodes (IDEs) were screen printed onto Kapton® substrate using commercially avaiable silver ink. Thermistor inks with different weight ratios of SiC nanoparticles were printed atop the IDE structures to form fully printed thermistors. The thermistors were tested over a wide temperature range form 25 °C to 170 °C, exhibiting excellent repeatability and stability over 15 h of continuous operation. Optimal device performance was achieved with 30 wt.% SiC-polyimide ink. We report highly sensitive devices with a TCR of -0.556%/°C, a thermal coefficient of 502 K (ß-index) and an activation energy of 0.08 eV. Further, the thermistor demonstrates an accuracy of ±1.35 °C, which is well within the range offered by commercially available high sensitivity thermistors. SiC thermistors exhibit a small 6.5% drift due to changes in relative humidity between 10 and 90%RH and a 4.2% drift in baseline resistance after 100 cycles of aggressive bend testing at a 40° angle. The use of commercially available low-cost materials, simplicity of design and fabrication techniques coupled with the chemical inertness of the Kapton® substrate and SiC nanoparticles paves the way to use all-printed SiC thermistors towards a wide range of applications where temperature monitoring is vital for optimal system performance.

2.
Eur J Obstet Gynecol Reprod Biol ; 297: 221-226, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38691974

RESUMO

OBJECTIVE(S): Empty follicle syndrome (EFS) is a condition in which no oocytes are retrieved in an IVF cycle despite apparently normal follicular development and meticulous follicular aspiration following ovulation induction. The EFS is called genuine (gEFS) when the trigger administration is correct. The existence of gEFS is a subject of controversy, and it is quite rare with an undetermined etiology. Genetic defects in specific genes have been demonstrated to be responsible for this condition in some patients. Our objective was to identify novel genetic variants associated with gEFS. STUDY DESIGN: We conducted a prospective observational study including 1,689 egg donors from July 2017 to February 2023. WES were performed in patients suffering gEFS. RESULTS: Only 7 patients (0.41 %) exhibited gEFS after two ovarian stimulation cycles and we subsequently performed whole exome sequencing (WES) on these patients. Following stringent filtering, we identified 6 variants in 5 affected patients as pathogenic in new candidate genes which have not been previously associated with gEFS before, but which are involved in important biological processes related to folliculogenesis. These genetic variants included c.603_618del in HMMR, c.1025_1028del in LMNB1, c.1091-1G > A in TDG, c.607C > T in HABP2, c.100 + 2 T > C in HAPLN1 and c.3592_3593del in JAG2. CONCLUSION: As a conclusion, we identified new candidate genes related to gEFS that expand the mutational spectrum of genes related to gEFS.This study show that WES might be an efficient tool to identify the genetic etiology of gEFS and provide further understanding of the pathogenic mechanism of gEFS.


Assuntos
Sequenciamento do Exoma , Folículo Ovariano , Humanos , Feminino , Adulto , Estudos Prospectivos , Indução da Ovulação , Doenças Ovarianas/genética
3.
Phlebology ; : 2683555241230737, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38782035

RESUMO

Chronic venous disease (CVD) is an umbrella term for a group of morphological and functional disorders of the venous system. Clinical signs of CVD may range from telangiectasia and reticular veins to active venous ulcers; therefore, earlier diagnosis and management of CVD may delay disease progression and reduce the burden of CVD on patients, caregivers, and healthcare systems. In this podcast discussion, Professor Andrew Nicolaides, Professor Stavros Kakkos, and Dr Gerardo Estrada-Guerrero share the key highlights from their symposium at the 2023 European Venous Forum. This symposium, titled "Chronic venous disease: what if everything started with early care?", discussed the clinical significance of "functional CVD," evidence and risk factors for CVD progression, and real-world strategies to facilitate earlier diagnosis and management of CVD. Together, these topics highlight the importance of early care to improve long-term outcomes for people with CVD.


Chronic venous disease (CVD) occurs when the blood vessels that carry blood back to the heart are damaged. In the early stages of CVD, people may have visible or swollen veins in their legs and feet, and may feel pain, heaviness, burning, itching, and cramping. Without treatment, people with CVD may develop open sores (ulcers) that are hard to heal and could get infected, so it is important that CVD is diagnosed and treated early. In this podcast, three doctors who specialize in CVD answer questions about a presentation they gave at a recent medical conference. In their presentation, the doctors talked about people who experience feelings of CVD but without any visible signs, and looked at programs that might help doctors diagnose CVD earlier. The doctors agree that it is important to diagnose and treat CVD early, so that people can avoid the long-term effects of this disease.

4.
World Neurosurg ; 187: e1062-e1071, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38744375

RESUMO

OBJECTIVES: The modified 5-item frailty index (mFI-5) is a comorbidity-based risk stratification tool to predict adverse events following various neurologic surgeries. This study aims to quantify the association between increased mFI-5 and postoperative complications and mortality following surgical fixation of traumatic thoracolumbar fractures. METHODS: The 2011-2021 American College of Surgeons - National Surgical Quality Improvement Program (ACS-NSQIP) dataset was used to identify patients undergoing fusion surgeries for thoracolumbar spine fractures. The mFI-5 score was calculated based on the presence of 5 major comorbidities: congestive heart failure within 30 days before surgery, insulin-dependent or noninsulin-dependent diabetes mellitus, chronic obstructive pulmonary disease, partially dependent or totally dependent functional health status at the time of surgery, and hypertension requiring medication. Multivariate analysis assessed the independent impact of increasing mFI-5 scores on postoperative 30-day morbidity and mortality while controlling for baseline clinical characteristics. RESULTS: A total of 66,904 patients were included in our analysis (54.2% female, mean age 62.27 ± 12.93 years). On univariate analysis, higher mFI-5 score was significantly associated with increased risks of superficial surgical site infection, deep surgical site infection, wound dehiscence, unplanned reoperation, pneumonia, unplanned intubation, postoperative ventilator use, progressive renal insufficiency, acute renal failure, urinary tract infection, stroke, myocardial infarction, cardiac arrest, pulmonary embolism, deep vein thrombosis, bleeding requiring transfusion, sepsis, septic shock, and longer hospital length of stay (LOS). On multivariate logistic regression, increasing mFI-5 score versus a mFI-5 score of zero was associated with higher odds of overall complications (mFI-5 ≥2: odds ratio [OR] 1.38 CI: 1.24-1.54, P < 0.001; mFI-5 = 1: OR 1.18 CI: 1.11-1.24, P < 0.001) and 30-day mortality (mFI-5 ≥2: OR 2.33 CI: 1.60-3.38, P < 0.001). CONCLUSION: This study demonstrates that frailty, when measured using the mFI-5, independently predicts postoperative complications, hospital LOS, and 30-day mortality after surgical repair of thoracolumbar fractures. These findings are important for risk stratification in patients undergoing thoracolumbar fusion surgery and for standardization in reporting outcomes after those procedures.


Assuntos
Fragilidade , Vértebras Lombares , Complicações Pós-Operatórias , Fraturas da Coluna Vertebral , Vértebras Torácicas , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Vértebras Torácicas/cirurgia , Vértebras Torácicas/lesões , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/mortalidade , Idoso , Vértebras Lombares/cirurgia , Fragilidade/complicações , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos
5.
World Neurosurg ; 188: e34-e40, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38710406

RESUMO

OBJECTIVE: This study aims to assess race as an independent risk factor for postoperative complications after surgical fixation of traumatic thoracolumbar fractures for African American and Asian American patients compared with White patients. METHODS: The 2011-2021 American College of Surgeons - National Surgical Quality Improvement Program (ACS-NSQIP) dataset was used to identify patients undergoing fusion surgeries for thoracolumbar spine fractures. Patient comorbidity burden was assessed using a modified 5-item frailty index score (mFI-5). Chi-squared and ANOVA tests were used to compare baseline clinical characteristics between groups. Multivariate analysis was performed to compare African American and Asian American patients with White patients controlling for age, BMI, and American Society of Anesthesiologists (ASA) score. RESULTS: African American patients experienced longer operative times compared to Asian American and White patients (3.74 ± 1.87 hours vs. 3.04 ± 1.71 hours and 3.48 ± 1.81 hours, P < 0.001). African American and Asian American patients demonstrated higher comorbidity burden with mFI-5>2 compared to White patients (30.7% and 25.6% vs. 19.9%, P < 0.001). African American and Asian American patients had a higher risk of postoperative complications than White patients (22.4% and 20% vs. 19.7%, P < 0.001). African American race was an independent risk factor of postoperative 30-day morbidity (OR 1.19, CI 1.11-1.28, P < 0.001). CONCLUSIONS: African American and Asian American patients undergoing thoracolumbar fusion surgeries exhibit disproportionate comorbidity burden, longer LOS, and greater postoperative complications compared with White patients. Furthermore, the African American race was associated with an increased rate of 30-day postoperative complications.


Assuntos
Vértebras Lombares , Complicações Pós-Operatórias , Fraturas da Coluna Vertebral , Vértebras Torácicas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Asiático , Negro ou Afro-Americano , Bases de Dados Factuais , Disparidades em Assistência à Saúde/etnologia , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etnologia , Fatores de Risco , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/etnologia , Fusão Vertebral , Vértebras Torácicas/cirurgia , Vértebras Torácicas/lesões , Resultado do Tratamento , Estados Unidos/epidemiologia , Brancos
6.
RSC Adv ; 14(7): 4748-4758, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38318609

RESUMO

Emerging flexible optoelectronic devices require multi-material processing capabilities to fully enable the use of temperature-sensitive substrates and materials. This report demonstrates how photonic sintering enables the processing of materials with very different properties. For example, charge carrier transport/blocking metal-oxides, and transparent conductive silver nanowire-based electrodes ought to be compatible with low-energy and high-throughput processing for integration onto flexible low-temperature substrates. Compared to traditional post-processing methods, we show a rapid fabrication route yielding highly-stable hybrid electrode architectures on polyethylene terephthalate (PET). This architecture consists of an interconnected silver nanowire network encapsulated with a thin crystalline photo-sensitive titanium dioxide (TiO2) coating, allowing both layers to be treated using independent photonic post-processing sintering steps. The first step sinters the nanowires, while the second completes the conversion of the top metal-oxide layer from amorphous to crystalline TiO2. This approach improves on the fabrication speed compared to oven processing, while delivering optical and electrical characteristics comparable to the state of the art. Optimized transparency values reach 85% with haze values down-to 7% at 550 nm, while maintaining a sheet resistance of 18.1 Ω sq.-1. However, this hybrid architecture provides a much stronger resilience to degradation, which we demonstrate through exposure to harsh plasma conditions. In summary, this study shows how carefully-optimized photonic curing post-processing can provide more-stable hybrid architectures while using a multi-material processing technique suitable for high-volume manufacturing on low-temperature substrates.

7.
Reprod Sci ; 31(6): 1705-1711, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38379066

RESUMO

Embryo culture is one of the most important steps in an assisted reproduction laboratory. Embryos can be cultured individually, one embryo per media drop, or in groups, culturing several embryos in the same media drop. Due to the controversy generated on this subject, we wondered which embryo culture method would have the best results in terms of quality and blastocyst formation rate. We designed a prospective randomized study comparing two different embryo culture strategies: group and individual embryo culture. The data were obtained from 830 embryos from 103 egg donation treatments. The zygotes were randomized into two groups: individual culture (group 1) or group culture (group 2). The embryos were cultured in 35-µl drops until day 5 when they were classified morphologically. We observed a significant increase in the blastocyst formation rate and in the usable embryo rate in individual culture on day 5 compared to group culture. However, good embryo quality (A/B blastocysts), implantation, and pregnancy rates were similar regardless of the type of embryo-culture. As a conclusion, individual culture may increase blastocyst formation rate and may benefit embryo quality on day 5. Our results support previous reports suggesting that individual culture could improve embryo development.


Assuntos
Blastocisto , Técnicas de Cultura Embrionária , Taxa de Gravidez , Técnicas de Cultura Embrionária/métodos , Humanos , Feminino , Gravidez , Adulto , Transferência Embrionária/métodos , Fertilização in vitro/métodos , Desenvolvimento Embrionário/fisiologia , Estudos Prospectivos , Implantação do Embrião/fisiologia
8.
J Neural Eng ; 21(1)2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237175

RESUMO

Peripheral nerve interfaces (PNIs) are electrical systems designed to integrate with peripheral nerves in patients, such as following central nervous system (CNS) injuries to augment or replace CNS control and restore function. We review the literature for clinical trials and studies containing clinical outcome measures to explore the utility of human applications of PNIs. We discuss the various types of electrodes currently used for PNI systems and their functionalities and limitations. We discuss important design characteristics of PNI systems, including biocompatibility, resolution and specificity, efficacy, and longevity, to highlight their importance in the current and future development of PNIs. The clinical outcomes of PNI systems are also discussed. Finally, we review relevant PNI clinical trials that were conducted, up to the present date, to restore the sensory and motor function of upper or lower limbs in amputees, spinal cord injury patients, or intact individuals and describe their significant findings. This review highlights the current progress in the field of PNIs and serves as a foundation for future development and application of PNI systems.


Assuntos
Amputados , Nervos Periféricos , Humanos , Amputação Cirúrgica , Eletrodos , Paralisia/cirurgia
9.
Oper Neurosurg (Hagerstown) ; 26(3): 309-313, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37890096

RESUMO

BACKGROUND AND OBJECTIVES: Intrathecal drug therapy is a common treatment for dystonia, pain, and spasticity using implanted pump and catheter systems. Standardized management of intrathecal drug pump (ITDP) migration and flipping has not been well established in the literature. This study reports the use of soft tissue to address less common pump complications such as pump flipping, migration, and difficulty in medication refill. METHODS: A retrospective chart review of intrathecal pump cases performed by two surgeons between February 2020 and August 2022 was conducted. Patients with complications such as pump flipping, migration, or challenges in medication refill treated with soft tissue flaps were included. Patient demographics, comorbidities, and perioperative data were collected. RESULTS: A total of five patients with ITDP complicated by pump flipping, migration, malposition, or difficulty in medication refill that were treated using fascial flaps were included in the study. Three technical considerations when revising ITDP complications are secure pump anchoring, reliable wound closure, and ease of pump medication refill. Cases 1 and 2 demonstrate the technique of secure pump anchoring with a rectus fascial flap. Cases 3 and 4 show a technique to achieve reliable vascularized wound closure, and case 5 describes a technique to solve an uncommon problem of a thick subcutaneous abdominal tissue preventing the refill of the ITDP medication. CONCLUSION: Soft tissue flaps may serve as a treatment option for patients with uncommon ITDP complications. De-epithelialized dermal fasciocutaneous or fascial flaps may be developed to anchor the pump more securely. Cross-discipline collaboration may further delineate the technique, benefits, and outcomes of this approach.


Assuntos
Bombas de Infusão Implantáveis , Retalhos Cirúrgicos , Humanos , Estudos Retrospectivos , Bombas de Infusão Implantáveis/efeitos adversos , Espasticidade Muscular/tratamento farmacológico , Espasticidade Muscular/cirurgia , Espasticidade Muscular/etiologia , Abdome
10.
Reprod Biomed Online ; 48(1): 103572, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37979227

RESUMO

RESEARCH QUESTION: Do live birth rates differ between recipients matched with donors using conventional ovarian stimulation compared with those using random-start protocols? DESIGN: Retrospective analysis of 891 ovarian stimulations in egg donors (January-December 2018) and clinical outcomes in matched recipients (n = 935). Donors commenced ovarian stimulation on day 1-3 of the menstrual cycle (n = 223) or in the mid/late-follicular (n = 388) or luteal phase (n = 280) under a conventional antagonist protocol. Live birth rate of matched recipients was the main outcome. RESULTS: Duration of stimulation and total gonadotrophin dose were comparable between conventional versus random-start groups. The number of collected eggs were similar (17.6 ± 8.8 versus 17.2 ± 8.5, P = 0.6, respectively). Sub-group analysis showed that stimulation length (10.2 ± 1.8 versus 9.8 ± 1.7 versus 10.4 ± 1.7, P < 0.001) and gonadotrophin consumption (2041.5 ± 645.3 versus 2003.2 ± 647.3 versus 2158.2 ± 685.7 IU, P = 0.01) differed significantly between the conventional, mid/late follicular and luteal phase groups, respectively. In matched recipients receiving fresh oocytes and undergoing fresh embryo transfer, the biochemical pregnancy (63.8% and 63.3%; P = 0.9), clinical pregnancy (54.6% and 56.1%; P = 0.8) and live birth rates (47.7% and 46.6%; P = 0.7) per embryo-transfer were similar between conventional versus random groups. Similar results were obtained in recipients receiving vitrified eggs. Euploidy rate was also comparable. CONCLUSIONS: No notable variations were found in clinical outcomes using oocytes obtained from random-start protocols and those proceeding from conventional ovarian stimulation in oocyte donation treatments. Luteal-phase stimulation seems to require longer stimulation and higher FSH consumption. Random-start stimulation strategy does not impair the potential of the oocyte yield or clinical outcomes in oocyte donation cycles.


Assuntos
Fertilização in vitro , Doação de Oócitos , Gravidez , Feminino , Humanos , Fertilização in vitro/métodos , Estudos Retrospectivos , Transferência Embrionária/métodos , Indução da Ovulação/métodos , Gonadotropinas , Taxa de Gravidez
11.
Front Endocrinol (Lausanne) ; 14: 1216671, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37529596

RESUMO

Background: Double ovarian stimulation is one of the most used strategies in poor-prognosis patients. There is a high heterogeneity between the studies regarding the execution of this stimulation protocol. The aim of this study was to investigate whether the day on which luteal phase stimulation begins after the first oocyte retrieval affects ovarian response in DuoStim cycles. Methods: This observational and retrospective study included 541 DuoStim cycles between January 2018 and December 2021 in a private fertility clinic. Patients were assigned to 4 groups according to the timing of the onset of luteal phase stimulation after oocyte retrieval (0-2nd day, 3rd day, 4th day and 5th-6th day). The primary outcome was the number of oocytes retrieved in the luteal phase in each group. Results: No differences were found between groups in the number of oocytes collected (5.12 ± 3.56 vs. 5.39 ± 3.74 vs. 5.61 ± 3.94 vs. 5.89 ± 3.92; p=0,6), MII or number of follicles. An increase in the duration of stimulation was found when stimulation started on the 4th day (10.42 ± 2.31 vs. 10.68 ± 2.37 vs. 11.27 ± 2.40 vs. 10.65 ± 2.37 days, p=0,033). A lower number of fertilized oocytes was observed when stimulation began before the fourth day (3.36 ± 2.80 vs. 3.95 ± 2.53 vs. 4.03 ± 2.73 vs. 4.48 ± 3.11; p=0,036). The number of blastocysts was higher when the stimulation started 5-6 days after retrieval (1.82 ± 1.74 vs. 2.13 ± 1.61 vs. 2.33 ± 2.06 vs. 2.91 ± 2.39; p= 0,030). Discussion: The number of oocytes retrieved does not differ depending on the day that stimulation begins. However, oocytes competence in terms of fertilized oocytes and blastulation, appears to be lower when the second stimulation starts before the fourth day after oocyte retrieval.


Assuntos
Fase Luteal , Oócitos , Feminino , Animais , Fase Luteal/fisiologia , Estudos Retrospectivos , Oócitos/fisiologia , Recuperação de Oócitos/métodos
12.
J Neurosurg Case Lessons ; 5(26)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37399140

RESUMO

BACKGROUND: Schwannomas are common peripheral nerve sheath tumors. Imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT) can help to distinguish schwannomas from other types of lesions. However, there have been several reported cases describing the misdiagnosis of aneurysms as schwannomas. OBSERVATIONS: A 70-year-old male with ongoing pain despite spinal fusion surgery underwent MRI. A lesion was noted along the left sciatic nerve, which was believed to be a sciatic nerve schwannoma. During the surgery for planned neurolysis and tumor resection, the lesion was noted to be pulsatile. Electromyography mapping and intraoperative ultrasound confirmed vascular pulsations and turbulent flow within the aneurysm, so the surgery was aborted. A formal CT angiogram revealed the lesion to be an internal iliac artery (IIA) branch aneurysm. The patient underwent coil embolization with complete obliteration of the aneurysm. LESSONS: The authors report the first case of an IIA aneurysm misdiagnosed as a sciatic nerve schwannoma. Surgeons should be aware of this potential misdiagnosis and potentially use other imaging modalities to confirm the lesion before proceeding with surgery.

13.
JBRA Assist Reprod ; 27(3): 355-359, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-36749808

RESUMO

OBJECTIVE: Is self-detection of the endogenous LH surge using a urine testing a reliable method to confirm a successful gonadotropin-releasing hormone agonist (GnRHa) trigger in IVF cycles? METHODS: Prospective observational study including a total of 103 oocyte donation cycles between November 2019 and January 2020. Urine LH testing (Akralab SL, Spain, cut-of value 30 mIU/mL) was performed at home in samples from the first micturition in the morning after the GnRHa trigger and a picture of the result was sent to the nurse coordinator; this information was concealed and only disclosed after oocyte aspiration. RESULTS: From the total group, two cycles were excluded. A total of 101 oocyte donors performed the LH urine testing, all proceeded to oocyte aspiration and were included in final analysis. A total of 85 (84.2%) had a positive LH test and an uneventful oocyte retrieval with good retrieval rates (false positive rate: 0%). A total of 16 had a negative LH test (15.8%) and had a good oocyte retrieval rates (false negative rate: 15.8%). There were no cases of empty follicle syndrome. CONCLUSIONS: Due to a high false negative rate, self-testing of endogenous LH release using a LH urine test when performed approximately 12-hours after triggering does not seem to be a reliable method to predict a suboptimal response to gonadotropin-releasing hormone.


Assuntos
Hormônio Luteinizante , Indução da Ovulação , Humanos , Indução da Ovulação/métodos , Fertilização in vitro/métodos , Hormônio Liberador de Gonadotropina , Oócitos/fisiologia , Gonadotropina Coriônica
14.
Reprod Biomed Online ; 46(4): 697-704, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36803967

RESUMO

RESEARCH QUESTION: What is the effect of mRNA severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccination in young oocyte donors in terms of ovarian response to stimulation, fertilization rate, embryo development and clinical outcomes in recipients? DESIGN: This retrospective, multicentre cohort study evaluated 115 oocyte donors who had undergone at least two ovarian stimulation protocols (before and after complete SARS-CoV-2 vaccination) between November 2021 and February 2022. Comparisons were made of the primary outcomes of days of stimulation, total dose of gonadotrophins and laboratory performance in ovarian stimulation in oocyte donors before and after vaccination. A total of 136 cycles in matched recipients were analysed as secondary outcomes and, from those, 110 women received a fresh single-embryo transfer, with analysis of biochemical ß-human chorionic gonadotrophin concentrations and rates of clinical pregnancy with heartbeat. RESULTS: Longer stimulation was required in the post-vaccination than pre-vaccination group (10.31 ± 1.5 versus 9.51 ± 1.5 days; P < 0.001) along with higher gonadotrophin consumption (2453.5 ± 740 versus 2235.5 ± 615 IU; P < 0.001) with a similar starting dose of gonadotrophins in both groups. More oocytes were retrieved in the post-vaccination group (16.62 ± 7.1 versus 15.38 ± 7.0; P = 0.02). However, the number of metaphase II (MII) oocytes was similar between groups (pre-vaccination 12.61 ± 5.9 versus post-vaccination 13.01 ± 6.6; P = 0.39) and the ratio of MII/retrieved oocytes favoured the pre-vaccination group (0.83 ± 0.1 versus 0.77 ± 0.2 post-vaccination; P = 0.019). In recipients with a similar number of provided oocytes, the fertilization rate, total number of obtained blastocysts, number of top-quality blastocysts, and rates of biochemical pregnancy and clinical pregnancy with heartbeat were not significantly different between groups. CONCLUSIONS: This study shows no adverse influence of mRNA SARS-CoV-2 vaccination on ovarian response in a young population.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Gravidez , Humanos , Feminino , Fertilização in vitro/métodos , Estudos Retrospectivos , Estudos de Coortes , SARS-CoV-2 , Oócitos/fisiologia , Indução da Ovulação/métodos , Gonadotropinas , Taxa de Gravidez
15.
Oper Neurosurg (Hagerstown) ; 24(4): 445-450, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36715998

RESUMO

BACKGROUND: Mechanomyography (MMG) is a novel intraoperative tool to detect and quantify nerve activity with high sensitivity as compared with traditional electromyographic recordings. MMG reflects the mechanical vibrations of single motor units detected through accelerometer sensors after direct motor neuron stimulation. OBJECTIVE: To determine the feasibility of applying intraoperative MMG during peripheral nerve surgery. METHODS: A total of 20 consecutive patients undergoing surgical decompression of the ulnar nerve at the cubital tunnel or common peroneal nerve at the fibular head were included in this study. Intraoperatively, the common peroneal and ulnar nerves were directly stimulated through the MMG electrode probe starting at 0.1 mA threshold and increasing by 0.1 mA increments until target muscle activity was noted. The lowest threshold current required to elicit a muscle response was recorded before decompression and after proximal and distal nerve decompression. RESULTS: Of the patients, 80% (16/20) had MMG signals detected and recorded. Four patients were unable to have MMG signal detected despite direct nerve visualization and complete neurolysis. The mean predecompression stimulus threshold was 1.59 ± 0.19 mA. After surgical decompression, improvement in the mean MMG stimulus threshold was noted (0.47 ± 0.03 mA, P = .0002). Postoperatively, all patients endorsed symptomatic improvement with no complications. CONCLUSION: MMG may provide objective guidance for the intraoperative determination of the extent of nerve decompression. Lower stimulus thresholds may represent increased sparing of axonal tissue. Future work should focus on validating normative values of MMG stimulus thresholds in various nerves and establishing clinical associations with functional outcomes.


Assuntos
Procedimentos Neurocirúrgicos , Nervo Ulnar , Humanos , Nervo Ulnar/cirurgia , Músculo Esquelético , Descompressão Cirúrgica
16.
JMIR Biomed Eng ; 8: e47146, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-38875670

RESUMO

BACKGROUND: Accurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea, as well as controlling ventilation for patients in intensive care units, during surgical procedures, or when using a positive airway pressure device for sleep apnea. OBJECTIVE: The purpose of this research is to develop a new nonprescription portable measurement device that utilizes relative humidity sensors (RHS) to accurately measure key respiratory parameters at a cost that is approximately 10 times less than the industry standard. METHODS: We present the development, implementation, and assessment of a wearable respiratory measurement device using the commercial Bosch BME280 RHS. In the initial stage, the RHS was connected to the pneumotach (PNT) gold standard device via its external connector to gather breathing metrics. Data collection was facilitated using the Arduino platform with a Bluetooth Low Energy connection, and all measurements were taken in real time without any additional data processing. The device's efficacy was tested with 7 participants (5 men and 2 women), all in good health. In the subsequent phase, we specifically focused on comparing breathing cycle and respiratory rate measurements and determining the tidal volume by calculating the region between inhalation and exhalation peaks. Each participant's data were recorded over a span of 15 minutes. After the experiment, detailed statistical analysis was conducted using ANOVA and Bland-Altman to examine the accuracy and efficiency of our wearable device compared with the traditional methods. RESULTS: The perfused air measured with the respiratory monitor enables clinicians to evaluate the absolute value of the tidal volume during ventilation of a patient. In contrast, directly connecting our RHS device to the surgical mask facilitates continuous lung volume monitoring. The results of the 1-way ANOVA showed high P values of .68 for respiratory volume and .89 for respiratory rate, which indicate that the group averages with the PNT standard are equivalent to those with our RHS platform, within the error margins of a typical instrument. Furthermore, analysis utilizing the Bland-Altman statistical method revealed a small bias of 0.03 with limits of agreement (LoAs) of -0.25 and 0.33. The RR bias was 0.018, and the LoAs were -1.89 and 1.89. CONCLUSIONS: Based on the encouraging results, we conclude that our proposed design can be a viable, low-cost wearable medical device for pulmonary parametric measurement to prevent and predict the progression of pulmonary diseases. We believe that this will encourage the research community to investigate the application of RHS for monitoring the pulmonary health of individuals.

17.
F S Rep ; 4(4): 344-352, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204945

RESUMO

Objective: To compare the oocyte yield between follicular-phase stimulation (FPS) and luteal-phase stimulation (LPS) in suboptimal responders. Design: Prospective, randomized, crossover clinical trial. Patients: Forty-one patients with infertility according to the POSEIDON (Patient-Oriented Strategies Encompassing IndividualizeD Oocyte Number) criteria (1b/2b). Interventions: Crossover study on 2 assigned ovarian stimulations that started randomly in the follicular or luteal phase. The in vitro fertilization cycles were not consecutive but separated in time (45 days to 6 months). The random crossover design ensured that all subjects received the first treatment by chance. Main Outcome Measures: The primary objective was the number of cumulus-oocyte complexes retrieved in each cycle. Secondary objectives were number of metaphase II and fertilized oocytes, additional doses of recombinant follicle-stimulating hormone, and the duration of ovarian stimulation (days). Results: The mean number of cumulus-oocyte complexes retrieved was similar between the FPS and LPS groups (7.5 ± 4.6 vs. 7.0 ± 4.1; 95% confidence interval [CI] for the mean, 5.8-8.7 vs. 5.6-8.3, respectively; the difference between means, -0.5; 95% CI, -1.8 to +1.5). Similarly, the mean number of metaphase II oocytes retrieved was not different between the FPS and LPS groups (5.4 ± 3.6 vs. 5.2 ± 2.8; 95% CI for the mean, 4.2-6.5 vs. 4.3-6.1, respectively; the difference between means, -0.2; 95% CI, -1.2 to +1.1). Moreover, the secondary objectives were similar between FPS and LPS groups. Conclusions: In this study, the oocyte yield in LPS did not increase in suboptimal responders compared with that in FPS when the onset of LPS was separated in time from FPS. Clinical Trial Registration Number: NCT039393990 https://beta.clinicaltrials.gov/study/NCT03939390.

18.
J Neurosurg Case Lessons ; 4(22)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36443958

RESUMO

BACKGROUND: Metastatic cancer may involve the central and peripheral nervous system, usually in the late stages of disease. At this point, most patients have been diagnosed and treated for widespread systemic disease. Rarely is the involvement of the peripheral nervous system the presenting manifestation of malignancy. One reason for this is a proposed "blood-nerve barrier" that renders the nerve sheath a relatively privileged site for metastases. OBSERVATIONS: The authors presented a novel case of metastatic melanoma presenting as intractable leg pain and numbness. Further workup revealed concurrent disease in the brain and breast, prompting urgent treatment with radiation and targeted immunotherapy. LESSONS: This case highlights the rare presentation of metastatic melanoma as a mononeuropathy. Although neurological complications of metastases tend to occur in later stages of disease after initial diagnosis and treatment, one must remember to consider malignancy in the initial differential diagnosis of mononeuropathy.

19.
J Neurosurg Case Lessons ; 4(17)2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36281475

RESUMO

BACKGROUND: Parkinson's disease (PD) is a common neurogenerative disease marked by the characteristic triad of bradykinesia, rigidity, and tremor. A significant percentage of patients with PD also demonstrate postural abnormalities (camptocormia) that limit ambulation and accelerate degenerative pathologies of the spine. Although deep brain stimulation (DBS) is a well-established treatment for the motor fluctuations and tremor seen in PD, the efficacy of DBS on postural abnormalities in these patients is less clear. OBSERVATIONS: The authors present a patient with a history of PD and prior lumbosacral fusion who underwent bilateral subthalamic nucleus DBS and experienced immediate improvement in sagittal alignment and subjective relief of mechanical low-back pain. LESSONS: DBS may improve postural abnormalities seen in PD and potentially delay or reduce the need for spinal deformity surgery.

20.
Sci Rep ; 12(1): 15441, 2022 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-36104380

RESUMO

In the last decades, titania (or TiO2) particles played a crucial role in the development of photo-catalysis and better environmentally-friendly energy-harvesting techniques. In this work, we engineer a new generation of TiO2 particles rich in oxygen vacancies using a modified sol-gel synthesis. By design, these vacancy-rich particles efficiently absorb visible light to allow carefully-controlled light-induced conversion to the anatase or rutile crystalline phases. FTIR and micro-Raman spectroscopy reveal the formation of oxygen vacancies during conversion and explain this unique laser-assisted crystallization mechanism. We achieve low-energy laser-assisted crystallization in ambient environment using a modified filament 3D printer equipped with a low-power laser printhead. Since the established high-temperature treatment necessary to convert to crystalline TiO2 is ill-suited to additive manufacturing platforms, this work removes a major fundamental hurdle and opens whole new vistas of possibilities towards the additive manufacturing of ceramics, including carefully-engineered crystalline TiO2 substrates with potential applications for new and better photo-catalysis, fuel cells and energy-harvesting technologies.

SELEÇÃO DE REFERÊNCIAS