Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(12)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38928703

RESUMO

Phacoemulsification is the standard of care in cataract surgery in the developed world, with patients having high expectations regarding visual results. Postoperative dissatisfaction due to negative dysphotopsia (ND) ranges from rare to very frequent; its etiology is unclear, and it affects postoperative satisfaction. Since one of the most frequently used strategies to avoid ND is related to intraocular lens (IOL) haptic orientation, we conducted a prospective interventional study that enrolled 197 patients who underwent standard phacoemulsification. All patients had a one-piece hydrophobic acrylic IOL implanted; in one group, the haptics were placed in any meridional axis except inferotemporal (IT) meridians, and in the other group, the IOL was implanted with the haptics in an IT position. Our results showed no statistically significant differences between groups when analyzing the correlation between the position of IOL haptics and the presence of ND in week one and month one. Also, pupillary diameter showed no statistically significant differences between patients with or without ND. Despite some studies claiming that haptic orientation prevents ND, we found that haptic orientation does not correlate with ND incidence and that ND decreases from day 1 to month 1. Our results support previous findings on the decrease in ND over time and that haptic orientation should not be considered an intraoperative strategy to avoid this unwanted phenomenon.

2.
Eur J Ophthalmol ; 34(1): 252-259, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37151018

RESUMO

PURPOSE: To determine the total alpha-synuclein (αSyn) reflex tears and its association with retinal layers thickness in Parkinson's disease (PD). METHODS: Fifty-two eyes of 26 PD subjects and 52 eyes of age-and sex-matched healthy controls were included. Total αSyn in reflex tears was quantified using a human total αSyn enzyme-linked immunosorbent assay (ELISA) kit. The retinal thickness was evaluated with spectral-domain optical coherence tomography. The Movement Disorder Society-Unified Parkinsons Disease Rating Scale (MDS-UPDRS), Non-Motor Symptoms Scale (NMSS), and Montreal Cognitive Assessment (MoCA) were used to assess motor, non-motor, and cognition. RESULTS: In PD, total αSyn levels were increased compared to control subjects [1.76pg/mL (IQR 1.74-1.80) vs 1.73pg/mL (IQR 1.70-1.77), p < 0.004]. The nerve fiber layer, ganglion cell layer, internal plexiform layer, inner nuclear layer, and outer nuclear layer were thinner in PD in comparison with controls (p < 0.05). The outer plexiform layer and retinal pigment epithelium were thicker in PD (p < 0.05). The total αSyn levels positively correlated with the central volume of the inner nuclear layer (r = 0.357, p = 0.009). CONCLUSION: Total αSyn reflex tear levels were increased in subjects with PD compared to controls. PD patients showed significant thinning of the inner retinal layers and thickening of outer retinal layers in comparison with controls. Total αSyn levels positively correlate with the central volume of the inner nuclear layer in PD. The combination of these biomarkers might have a possible role as a diagnostic tool in PD subjects.


Assuntos
Doença de Parkinson , Humanos , Doença de Parkinson/diagnóstico , alfa-Sinucleína , Fibras Nervosas , Retina , Epitélio Pigmentado da Retina , Tomografia de Coerência Óptica/métodos
3.
Life (Basel) ; 13(10)2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37895391

RESUMO

PURPOSE: To evaluate residual refractive astigmatism using the Panacea and enVista toric calculators, compared to the gold-standard Barrett toric calculator. DESIGN: A retrospective and comparative study was conducted in one center. METHODS: We reviewed the medical records of all patients with a diagnosis of senile cataracts and regular corneal astigmatism, without previous corneal or intraocular surgery, who underwent phacoemulsification with implantation of a toric intraocular lens, who had pre- and postoperative corneal topography, biometry, and refraction measurements. RESULTS: The frequency of preoperative astigmatism according to the axis was 70 (84%) eyes showing with-the-rule (WTR) astigmatism, 9 (14%) eyes with against-the-rule (ATR) astigmatism, and 1 (2%) eye with oblique astigmatism. Regarding astigmatism prediction errors, there were statistically significant differences between the enVista and Panacea calculators (median of 0.39, 0.18, and 0.52 for Barrett, enVista, and Panacea, respectively). The residual astigmatism prediction error centroid was similar for the Barrett and enVista toric calculators, and both were lower compared to the Panacea calculator (x-component p < 0.001). CONCLUSIONS: The enVista toric calculator incorporating the Emmetropia Verifying Optical (EVO) toric calculator provides similar results to the gold-standard Barrett calculator.

4.
Clin Ophthalmol ; 17: 2333-2339, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37600146

RESUMO

Purpose: To compare magnification and refocusing during phacoemulsification with the NGENUITY®â€¯3-D Visualization System (3-D) versus the conventional microscope (CM) OPMI LUMERA 700. Setting: This study was performed in the Department of Anterior Segment of the Fundación Hospital Nuestra Señora de la Luz. Design: Prospective, randomized, cross-sectional, multi-surgeon, and comparative study. Methods: This study enrolled 100 patients (eyes) scheduled for phacoemulsification to measure the number of times changes in focusing and magnification were needed during cataract surgery. Results: Our study included 100 patients. From the endpoints evaluated, "zoom-in" showed statistically significant differences for all of the four predefined cataract surgery steps (means: Step 1, 0.38 (CM) vs 0.08 (3-D); Step 2, 0.36 (CM) vs 0.06 (3-D); Step 3, 0.54 (CM) vs 0.22 (3-D); Step 4, 0.56 (CM) vs 0.24 (3-D); all comparisons, p <0.05). In Step 4, there was a statistically significant increased use of "focus-out" for the 3-D system (mean 0.16 (CM) vs 0.58 (3-D); p <0.05). "Focus-in" and "zoom-out" showed no group differences for all steps. The duration of surgery with the 3-D system was longer at each step and overall. The percentage of light intensity did not show a statistically significant difference between both systems, with a mean of 99.45 for CM vs 98.43% for the heads-up system. Conclusion: The heads-up 3-D system is a safe option that offers excellent magnification for anterior segment visualization. The surgical time is longer, but adjusting settings like light intensity and brightness may facilitate some surgical steps early in the learning curve.

5.
Cir Cir ; 91(1): 107-112, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36787599

RESUMO

PURPOSE: To evaluate the stability and the refractive error of the different intraocular lens (IOL) after cataract surgery. METHOD: Retrospective, observational and single-center study. Patients diagnosed with cataract and myopia who underwent a phacoemulsification surgery with intraocular lens placement without complications were included. All patients underwent a complete ophthalmological examination, ultrasound biomicroscopy was performed at 2 weeks, 1 and 3 months after surgery. Descriptive statistics were performed using measures of central tendency and comparative analyzes. A value of p < 0.05 was considered significant. RESULTS: Thirty-one subjects with a diagnosis of axial myopia and senile cataract were included, 20 women (64.5%) and 11 men (35.5%), with a mean age was 62.8 ± 13.14 years. The IOL displacement were not different for the upper, lower, temporal and nasal quadrants; however, we observed a tendency to inclination to the temporal sector (p = 0.054) between the first and third postoperative month. Therefore, the were no significant differences in spherical equivalent between groups postoperatively. CONCLUSIONS: The inclination of the IOL did not change over time after surgery, the changes were similar with the different three types of IOL.


OBJETIVO: Evaluar la estabilidad y el desplazamiento de diferentes lentes intraoculares (LIO) a los 3 meses y los cambios refractivos asociados después de la facoemulsificación. MÉTODO: Estudio retrospectivo, observacional y unicéntrico. Se revisaron expedientes de pacientes sometidos a cirugía de facoemulsificación con colocación de LIO. Se realizó un examen oftalmológico completo, ultrabiomicroscopía a las 2 semanas, 1 y 3 meses después de la cirugía. Se realizó estadística descriptiva y análisis comparativos. Se tomó como diferencia significativa un valor de p < 0.05. RESULTADOS: Se incluyeron 31 ojos con diagnóstico de miopía y catarata senil, 20 mujeres (64.5%) y 11 hombres (35.5%), con una edad media de 62.8 ± 13.14 años. En cuanto al desplazamiento de la LIO, no se observaron diferencias significativas para los cuadrantes superior, inferior, temporal y nasal. Se observa una tendencia hacia temporal (p = 0.054) entre el primer y el tercer mes posoperatorios. El equivalente esférico tampoco mostró diferencias. CONCLUSIONES: El desplazamiento de la LIO no cambió con el tiempo después de la facoemulsificación. Los cambios fueron similares con los tres diferentes tipos de LIO y al compararlos proporcionan estabilidad refractiva en pacientes miopes.


Assuntos
Extração de Catarata , Catarata , Miopia , Facoemulsificação , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...