1.
Front Physiol ; 14: 1057700, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36793415

RESUMO

Pulmonary vein isolation (PVI) is the most successful treatment for atrial fibrillation (AF) nowadays. However, not all AF patients benefit from PVI. In this study, we evaluate the use of ECGI to identify reentries and relate rotor density in the pulmonary vein (PV) area as an indicator of PVI outcome. Rotor maps were computed in a set of 29 AF patients using a new rotor detection algorithm. The relationship between the distribution of reentrant activity and the clinical outcome after PVI was studied. The number of rotors and proportion of PSs in different atrial regions were computed and compared retrospectively in two groups of patients: patients that remained in sinus rhythm 6 months after PVI and patients with arrhythmia recurrence. The total number of rotors obtained was higher in patients returning to arrhythmia after the ablation (4.31 ± 2.77 vs. 3.58 ± 2.67%, p = 0.018). However, a significantly higher concentration of PSs in the pulmonary veins was found in patients that remained in sinus rhythm (10.20 ± 12.40% vs. 5.19 ± 9.13%, p = 0.011) 6 months after PVI. The results obtained show a direct relationship between the expected AF mechanism and the electrophysiological parameters provided by ECGI, suggesting that this technology offers relevant information to predict the clinical outcome after PVI in AF patients.

2.
Physiol Meas ; 41(7): 075004, 2020 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-32470949

RESUMO

OBJECTIVE: Atrial dominant frequency (DF) maps undergoing atrial fibrillation (AF) presented good spatial correlation with those obtained with the non-invasive body surface potential mapping (BSPM). In this study, a robust BSPM-DF calculation method based on wavelet analysis is proposed. APPROACH: Continuous wavelet transform along 40 scales in the pseudo-frequency range of 3-30 Hz is performed in each BSPM signal using a Gaussian mother wavelet. DFs are estimated from the intervals between the peaks, representing the activation times, in the maximum energy scale. The results are compared with the traditionally widely applied Welch periodogram and the robustness was tested on different protocols: increasing levels of white Gaussian noise, artificial DF harmonics presence and reduction in the number of leads. A total of 11 AF simulations and 12 AF patients are considered in the analysis. For each patient, intracardiac electrograms were acquired in 15 locations from both atria. The accuracy of both methods was assessed by calculating the absolute errors of the highest DF BSPM (HDF BSPM ) with respect to the atrial HDF, either simulated or intracardially measured, and assumed correct if ≤1 Hz. The spatial distribution of the errors between torso DFs and atrial HDFs were compared with atria driving mechanism locations. Torso HDF regions, defined as portions of the maps with [Formula: see text] Hz were identified and the percentage of the torso occuping these regions was compared between methods. The robustness of both methods to white Gaussian noise, ventricular influence and harmonics, and to lower spatial resolution BSPM lead layouts was analyzed: computer AF models (567 leads vs 256 leads down to 16 leads) and patient data (67 leads vs 32 and 16 leads). MAIN RESULTS: The proposed method allowed an improvement in non-invasive estimation of the atria HDF. For the models the median relative errors were 7.14% for the wavelet-based algorithm vs 60.00% for the Welch method; in patients, the errors were 10.03% vs 12.66%, respectively. The wavelet method outperformed the Welch approach in correct estimations of atrial HDFs in models (81.82% vs 45.45%, respectively) and patients (66.67% vs 41.67%). A low positive BSPM-DF map correlation was seen between the techniques (0.47 for models and 0.63 for patients), highlighting the overall differences in DF distributions. The wavelet-based algorithm was more robust to white Gaussian noise, residual ventricular activity and harmonics, and presented more consistent results in lead layouts with low spatial resolution. SIGNIFICANCE: Estimation of atrial HDFs using BSPM is improved by the proposed wavelet-based algorithm, helping to increase the non-invasive diagnostic ability in AF.


Assuntos
Fibrilação Atrial/diagnóstico , Mapeamento Potencial de Superfície Corporal , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Algoritmos , Humanos
3.
Comput Biol Med ; 104: 319-328, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30558815

RESUMO

Atrial Flutter (AFL) termination by ablating the path responsible for the arrhythmia maintenance is an extended practice. However, the difficulty associated with the identification of the circuit in the case of atypical AFL motivates the development of diagnostic techniques. We propose body surface phase map analysis as a noninvasive tool to identify AFL circuits. Sixty seven lead body surface recordings were acquired in 9 patients during AFL (i.e. 3 typical, 6 atypical). Computed body surface phase maps from simulations of 5 reentrant behaviors in a realistic atrial structure were also used. Surface representation of the macro-reentrant activity was analyzed by tracking the singularity points (SPs) in surface phase maps obtained from band-pass filtered body surface potential maps. Spatial distribution of SPs showed significant differences between typical and atypical AFL. Whereas for typical AFL patients 70.78 ±â€¯16.17% of the maps presented two SPs simultaneously in the areas defined around the midaxialliary lines, this condition was only satisfied in 5.15 ±â€¯10.99% (p < 0.05) maps corresponding to atypical AFL patients. Simulations confirmed these results. Surface phase maps highlights the reentrant mechanism maintaining the arrhythmia and appear as a promising tool for the noninvasive characterization of the circuit maintaining AFL. The potential of the technique as a diagnosis tool needs to be evaluated in larger populations and, if it is confirmed, may help in planning ablation procedures.


Assuntos
Flutter Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal , Modelos Cardiovasculares , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
4.
Pacing Clin Electrophysiol ; 40(8): 940-946, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28586103

RESUMO

BACKGROUND: Ablation of drivers maintaining atrial fibrillation (AF) has been demonstrated as an effective therapy. Drivers in the form of rapidly activated atrial regions can be noninvasively localized to either left or right atria (LA, RA) with body surface potential mapping (BSPM) systems. This study quantifies the accuracy of dominant frequency (DF) measurements from reduced-leads BSPM systems and assesses the minimal configuration required for ablation guidance. METHODS: Nine uniformly distributed lead sets of eight to 66 electrodes were evaluated. BSPM signals were registered simultaneously with intracardiac electrocardiograms (EGMs) in 16 AF patients. DF activity was analyzed on the surface potentials for the nine leads configurations, and the noninvasive measures were compared with the EGM recordings. RESULTS: Surface DF measurements presented similar values than panoramic invasive EGM recordings, showing the highest DF regions in corresponding locations. The noninvasive DFs measures had a high correlation with the invasive discrete recordings; they presented a deviation of <0.5 Hz for the highest DF and a correlation coefficient of >0.8 for leads configurations with 12 or more electrodes. CONCLUSIONS: Reduced-leads BSPM systems enable noninvasive discrimination between LA versus RA DFs with similar results as higher-resolution 66-leads system. Our findings demonstrate the possible incorporation of simplified BSPM systems into clinical planning procedures for AF ablation.


Assuntos
Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Eletrocardiografia , Humanos
5.
Comput Biol Med ; 44: 15-26, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24377685

RESUMO

In this paper we studied the implementation and performance of adaptive step methods for large systems of ordinary differential equations systems in graphics processing units, focusing on the simulation of three-dimensional electric cardiac activity. The Rush-Larsen method was applied in all the implemented solvers to improve efficiency. We compared the adaptive methods with the fixed step methods, and we found that the fixed step methods can be faster while the adaptive step methods are better in terms of accuracy and robustness.


Assuntos
Algoritmos , Técnicas Eletrofisiológicas Cardíacas/métodos , Fenômenos Eletrofisiológicos , Coração , Modelos Cardiovasculares , Humanos
6.
Am J Physiol Heart Circ Physiol ; 300(4): H1393-401, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21257912

RESUMO

Dual atrioventricular (AV) nodal pathway physiology is described as two different wave fronts that propagate from the atria to the His bundle: one with a longer effective refractory period [fast pathway (FP)] and a second with a shorter effective refractory period [slow pathway (SP)]. By using His electrogram alternance, we have developed a mathematical model of AV conduction that incorporates dual AV nodal pathway physiology. Experiments were performed on five rabbit atrial-AV nodal preparations to develop and test the presented model. His electrogram alternances from the inferior margin of the His bundle were used to identify fast and slow wave front propagations. The ability to predict AV conduction time and the interaction between FP and SP wave fronts have been analyzed during regular and irregular atrial rhythms (e.g., atrial fibrillation). In addition, the role of dual AV nodal pathway wave fronts in the generation of Wenckebach periodicities has been illustrated. Finally, AV node ablative modifications have been evaluated. The model accurately reproduced interactions between FP and SP during regular and irregular atrial pacing protocols. In all experiments, specificity and sensitivity higher than 85% were obtained in the prediction of the pathway responsible for conduction. It has been shown that, during atrial fibrillation, the SP ablation significantly increased the mean HH interval (204 ± 39 vs. 274 ± 50 ms, P < 0.05), whereas FP ablation did not produce significant slowing of ventricular rate. The presented mathematical model can help in understanding some of the intriguing AV node mechanisms and should be considered as a step forward in the studies of AV nodal conduction.


Assuntos
Nó Atrioventricular/fisiologia , Sistema de Condução Cardíaco/fisiologia , Modelos Cardiovasculares , Animais , Arritmias Cardíacas/fisiopatologia , Nó Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Coelhos , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia
7.
Artigo em Inglês | MEDLINE | ID: mdl-22255455

RESUMO

Current techniques for atrial flutter (AFL) treatment involve radiofrequency ablation. This is a relatively simple and short procedure for typical AFL, whereas becomes more complex and unpredictable in the case of atypical AFL. Therefore, non-invasive characterization of AFL would be helpful for the management of ablation procedures. In this study the behavior of typical and atypical AFL groups is characterized from the vectorcardiographic AFL loops. The initial hypothesis is that typical AFL loops resemble each other, whereas atypical AFL loops differ from typical AFL ones. All patient loops were compared to a reference, by analyzing the global trajectory, pathway complexity and distance to the reference loop. The distance was the most significative parameter, being 0.445 ± 0.135 and 0.799 ± 0.144 for typical and atypical AFL (p = 8.00 e-5). In addition, an intrapatient analysis revealed a higher stability of typical AFL loops than in the case of atypical AFL.


Assuntos
Algoritmos , Flutter Atrial/diagnóstico , Diagnóstico por Computador/métodos , Vetorcardiografia/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade