Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 8163, 2020 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-32424216

RESUMO

Precambrian cellular remains frequently have simple morphologies, micrometric dimensions and are poorly preserved, imposing severe analytical and interpretational challenges, especially for irrefutable attestations of biogenicity. The 1.88 Ga Gunflint biota is a Precambrian microfossil assemblage with different types and qualities of preservation across its numerous geological localities and provides important insights into the Proterozoic biosphere and taphonomic processes. Here we use synchrotron-based ptychographic X-ray computed tomography to investigate well-preserved carbonaceous microfossils from the Schreiber Beach locality as well as poorly-preserved, iron-replaced fossil filaments from the Mink Mountain locality, Gunflint Formation. 3D nanoscale imaging with contrast based on electron density allowed us to assess the morphology and carbonaceous composition of different specimens and identify the minerals associated with their preservation based on retrieved mass densities. In the Mink Mountain filaments, the identification of mature kerogen and maghemite rather than the ubiquitously described hematite indicates an influence from biogenic organics on the local maturation of iron oxides through diagenesis. This non-destructive 3D approach to microfossil composition at the nanoscale within their geological context represents a powerful approach to assess the taphonomy and biogenicity of challenging or poorly preserved traces of early microbial life, and may be applied effectively to extraterrestrial samples returned from upcoming space missions.

2.
Phys Med Biol ; 64(15): 155010, 2019 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-31234149

RESUMO

Scanning small-angle x-ray scattering (SAXS) measurements were performed on 36 formalin-fixed breast tissue biopsies obtained from two patients. All samples contained microcalcifications of type II, i.e. formed by hydroxyapatite. We demonstrate the feasibility of classifying breast lesions by scanning SAXS of tissues containing microcalcifications with a resolution of 35 [Formula: see text]m [Formula: see text] 30 [Formula: see text]m. We report a characteristic Bragg peak found around q = 1.725 nm-1 that occurs primarily for malignant lesions. Such a clear SAXS fingerprint is potentially linked to structural changes of breast tissue and corresponds to dimensions of about 3.7 nm. This material property could be used as an early indicator of malignancy development, as it is readily assessed by SAXS. If this fingerprint is combined with other known SAXS features, which also indicate the level of malignancy, such as lipid spacing and collagen periodicity, it could complement traditional pathology-based analyses. To confirm the SAXS-based classification, a histopathological workup and a gold standard histopathological diagnosis were conducted to determine the malignancy level of the lesions. Our aim is to report this SAXS fingerprint, which is clearly related to malignant breast lesions. However, any further conclusion based on our dataset is limited by the low number of patients and samples. Running a broad study to increase the number of samples and patients is of great importance and relevance for the breast-imaging community.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Radiografia/métodos , Espalhamento a Baixo Ângulo , Difração de Raios X/métodos , Mama/patologia , Feminino , Humanos , Radiografia/normas , Cintilografia
3.
J Appl Crystallogr ; 51(Pt 5): 1378-1386, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30279640

RESUMO

In most cases, the analysis of small-angle and wide-angle X-ray scattering (SAXS and WAXS, respectively) requires a theoretical model to describe the sample's scattering, complicating the interpretation of the scattering resulting from complex heterogeneous samples. This is the reason why, in general, the analysis of a large number of scattering patterns, such as are generated by time-resolved and scanning methods, remains challenging. Here, a model-free classification method to separate SAXS/WAXS signals on the basis of their inflection points is introduced and demonstrated. This article focuses on the segmentation of scanning SAXS/WAXS maps for which each pixel corresponds to an azimuthally integrated scattering curve. In such a way, the sample composition distribution can be segmented through signal classification without applying a model or previous sample knowledge. Dimensionality reduction and clustering algorithms are employed to classify SAXS/WAXS signals according to their similarity. The number of clusters, i.e. the main sample regions detected by SAXS/WAXS signal similarity, is automatically estimated. From each cluster, a main representative SAXS/WAXS signal is extracted to uncover the spatial distribution of the mixtures of phases that form the sample. As examples of applications, a mudrock sample and two breast tissue lesions are segmented.

4.
Opt Express ; 26(13): 16752-16768, 2018 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-30119497

RESUMO

In X-ray computed tomography, the task of imaging only a local region of interest (ROI) inside a larger sample is very important. However, without a priori information, this ROI cannot be exactly reconstructed using only the image data limited to the ROI. We propose here an approach of region-of-interest tomography, which reconstructs a ROI within an object from projections of different fields of view acquired on a specific angular sampling scheme in the same tomographic experiment. We present a stable procedure that not only yields high-quality images of the ROI but keeps as well the quantitative contrast on the reconstructed images. In addition, we analyze the minimum number of projections required for ROI tomography from the point of view of the band region of the Radon transform, which confirms this number must be estimated based on the size of the entire object and not only on the size of the ROI.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Simulação por Computador , Humanos
5.
Rev Sci Instrum ; 89(4): 043706, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29716370

RESUMO

For many scientific questions gaining three-dimensional insight into a specimen can provide valuable information. We here present an instrument called "tOMography Nano crYo (OMNY)," dedicated to high resolution 3D scanning x-ray microscopy at cryogenic conditions via hard X-ray ptychography. Ptychography is a lens-less imaging method requiring accurate sample positioning. In OMNY, this in achieved via dedicated laser interferometry and closed-loop position control reaching sub-10 nm positioning accuracy. Cryogenic sample conditions are maintained via conductive cooling. 90 K can be reached when using liquid nitrogen as coolant, and 10 K is possible with liquid helium. A cryogenic sample-change mechanism permits measurements of cryogenically fixed specimens. We compare images obtained with OMNY with older measurements performed using a nitrogen gas cryo-jet of stained, epoxy-embedded retina tissue and of frozen-hydrated Chlamydomonas cells.


Assuntos
Imageamento Tridimensional/instrumentação , Microscopia/instrumentação , Tomografia por Raios X/instrumentação , Animais , Chlamydomonas , Criopreservação/instrumentação , Desenho de Equipamento , Interferometria/instrumentação , Lasers , Imagem Óptica/instrumentação , Retina/citologia , Espalhamento a Baixo Ângulo , Temperatura , Difração de Raios X/instrumentação
6.
Nat Commun ; 8(1): 809, 2017 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-28993649

RESUMO

Since its commercial introduction three-quarters of a century ago, fluid catalytic cracking has been one of the most important conversion processes in the petroleum industry. In this process, porous composites composed of zeolite and clay crack the heavy fractions in crude oil into transportation fuel and petrochemical feedstocks. Yet, over time the catalytic activity of these composite particles decreases. Here, we report on ptychographic tomography, diffraction, and fluorescence tomography, as well as electron microscopy measurements, which elucidate the structural changes that lead to catalyst deactivation. In combination, these measurements reveal zeolite amorphization and distinct structural changes on the particle exterior as the driving forces behind catalyst deactivation. Amorphization of zeolites, in particular, close to the particle exterior, results in a reduction of catalytic capacity. A concretion of the outermost particle layer into a dense amorphous silica-alumina shell further reduces the mass transport to the active sites within the composite.Catalyst deactivation in fluid catalytic cracking processes is unavoidably associated with structural changes. Here, the authors visualize the deactivation of zeolite catalysts by ptychography and other imaging techniques, showing pronounced amorphization of the outer layer of the catalyst particles.

7.
Sci Rep ; 7(1): 6291, 2017 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-28740127

RESUMO

High-throughput three-dimensional cryogenic imaging of thick biological specimens is valuable for identifying biologically- or pathologically-relevant features of interest, especially for subsequent correlative studies. Unfortunately, high-resolution imaging techniques at cryogenic conditions often require sample reduction through sequential physical milling or sectioning for sufficient penetration to generate each image of the 3-D stack. This study represents the first demonstration of using ptychographic hard X-ray tomography at cryogenic temperatures for imaging thick biological tissue in a chemically-fixed, frozen-hydrated state without heavy metal staining and organic solvents. Applied to mammalian brain, this label-free cryogenic imaging method allows visualization of myelinated axons and sub-cellular features such as age-related pigmented cellular inclusions at a spatial resolution of ~100 nanometers and thicknesses approaching 100 microns. Because our approach does not require dehydration, staining or reduction of the sample, we introduce the possibility for subsequent analysis of the same tissue using orthogonal approaches that are expected to yield direct complementary insight to the biological features of interest.


Assuntos
Encéfalo/ultraestrutura , Microscopia Crioeletrônica/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia por Raios X/métodos , Animais , Camundongos , Camundongos Endogâmicos C57BL
8.
Nanoscale ; 7(32): 13765-74, 2015 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-26220159

RESUMO

Organic solar cells have great potential for upscaling due to roll-to-roll processing and a low energy payback time, making them an attractive sustainable energy source for the future. Active layers coated with water-dispersible Landfester particles enable greater control of the layer formation and easier access to the printing industry, which has reduced the use of organic solvents since the 1980s. Through ptychographic X-ray computed tomography (PXCT), we image quantitatively a roll-to-roll coated photovoltaic tandem stack consisting of one bulk heterojunction active layer and one Landfester particle active layer. We extract the layered morphology with structural and density information including the porosity present in the various layers and the silver electrode with high resolution in 3D. The Landfester particle layer is found to have an undesired morphology with negatively correlated top- and bottom interfaces, wide thickness distribution and only partial surface coverage causing electric short circuits through the layer. By top coating a polymer material onto the Landfester nanoparticles we eliminate the structural defects of the layer such as porosity and roughness, and achieve the increased performance larger than 1 V expected for a tandem cell. This study highlights that quantitative imaging of weakly scattering stacked layers of organic materials has become feasible by PXCT, and that this information cannot be obtained by other methods. In the present study, this technique specifically reveals the need to improve the coatability and layer formation of Landfester nanoparticles, thus allowing improved solar cells to be produced.

9.
Sci Rep ; 5: 9210, 2015 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-25790969

RESUMO

Bones are bio-composites with biologically tunable mechanical properties, where a polymer matrix of nanofibrillar collagen is reinforced by apatite mineral crystals. Some bones, such as antler, form and change rapidly, while other bone tissues, such as human tooth dentine, develop slowly and maintain constant composition and architecture for entire lifetimes. When studying apatite mineral microarchitecture, mineral distributions or mineralization activity of bone-forming cells, representative samples of tissue are best studied at submicrometre resolution while minimizing sample-preparation damage. Here, we demonstrate the power of ptychographic X-ray tomography to map variations in the mineral content distribution in three dimensions and at the nanometre scale. Using this non-destructive method, we observe nanostructures surrounding hollow tracts that exist in human dentine forming dentinal tubules. We reveal unprecedented quantitative details of the ultrastructure clearly revealing the spatially varying mineralization density. Such information is essential for understanding a variety of natural and therapeutic effects for example in bone tissue healing and ageing.


Assuntos
Dentina/química , Minerais/análise , Microtomografia por Raio-X/métodos , Humanos , Microscopia Eletrônica
10.
Sci Rep ; 4: 3857, 2014 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-24457289

RESUMO

X-ray ptychography is a scanning variant of coherent diffractive imaging with the ability to image large fields of view at high resolution. It further allows imaging of non-isolated specimens and can produce quantitative mapping of the electron density distribution in 3D when combined with computed tomography. The method does not require imaging lenses, which makes it dose efficient and suitable to multi-keV X-rays, where efficient photon counting, pixelated detectors are available. Here we present the first highly resolved quantitative X-ray ptychographic tomography of an extended object yielding 16 nm isotropic 3D resolution recorded at 2 Šwavelength. This first-of-its-kind demonstration paves the way for ptychographic X-ray tomography to become a promising method for X-ray imaging of representative sample volumes at unmatched resolution, opening tremendous potential for characterizing samples in materials science and biology by filling the resolution gap between electron microscopy and other X-ray imaging techniques.

11.
Opt Lett ; 39(18): 5281-4, 2014 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26466251

RESUMO

We have characterized the x-ray phase vortices generated at the focal spot of various spiral Fresnel zone plates with an outermost zone width of Δr=50 nm. The complex-valued wavefields of phase vortices as small as 50 nm in size (FWHM) and several topological charges were reconstructed using ptychographic coherent diffractive imaging. The reconstructed focal spots demonstrate good agreement with the theoretically expected wavefields and diffraction-limited focusing.

12.
Nat Commun ; 4: 1647, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23552062

RESUMO

Knowledge of the structure of biological macromolecules, especially in their native environment, is crucial because of the close structure-function relationship. X-ray small-angle scattering is used to determine the shape of particles in solution, but the achievable resolution is limited owing to averaging over particle orientations. In 1977, Kam proposed to obtain additional structural information from the cross-correlation of the scattering intensities. Here we develop the method in two dimensions, and give a procedure by which the single-particle diffraction pattern is extracted in a model-independent way from the correlations. We demonstrate its application to a large set of synchrotron X-ray scattering images on ensembles of identical, randomly oriented particles of 350 or 200 nm in size. The obtained 15 nm resolution in the reconstructed shape is independent of the number of scatterers. The results are discussed in view of proposed 'snapshot' scattering by molecules in the liquid phase at X-ray free-electron lasers.


Assuntos
Estrutura Molecular , Espalhamento de Radiação , Microscopia Eletrônica de Varredura , Difração de Raios X
13.
Rev Sci Instrum ; 83(7): 073703, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22852697

RESUMO

We present an instrument dedicated to 3D scanning x-ray microscopy, allowing a sample to be precisely scanned through a beam while the angle of x-ray incidence can be changed. The position of the sample is controlled with respect to the beam-defining optics by laser interferometry. The instrument achieves a position stability better than 10 nm standard deviation. The instrument performance is assessed using scanning x-ray diffraction microscopy and we demonstrate a resolution of 18 nm in 2D imaging of a lithographic test pattern while the beam was defined by a pinhole of 3 µm in diameter. In 3D on a test object of copper interconnects of a microprocessor, a resolution of 53 nm is achieved.

14.
Phys Rev Lett ; 105(9): 093901, 2010 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-20868161

RESUMO

In the context of x-ray lensless imaging, we present a recent approach for Fourier transform holography based on the use of extended references. Major advances shown here rely on a high signal efficiency and on the direct image reconstruction of the object performed by a simple linear derivative. Moreover, the extended holographic reference is easy to manufacture and can be applied to a variety of imaging experiments. Here we demonstrate single-shot imaging with a table-top, laser-based coherent soft x-ray source. A spatial resolution of 110 nm was obtained with an integration time of 20 fs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...