Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Echogr ; 30(2): 49-51, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33282640
2.
J Cardiovasc Med (Hagerstown) ; 15(8): 674-82, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24978660

RESUMO

In continuation of a previous publication, the present study will take into account for each application and profile the clinical use, the minimal data settings, the echo data findings, the indications, the quality process, the accreditation requirements, educational tailored pathway contents and modalities. The aim of the present document was to define the main applications of echocardiography and to tailor for each application-derived profile, according with the previous definitions, requirements that clearly identify the indication, objective, clinical situation in which echocardiography is used, educational pathway and training, quality process and accreditation.


Assuntos
Cardiologia/educação , Competência Clínica , Ecocardiografia/normas , Educação Continuada/normas , Acreditação , Humanos , Itália , Qualidade da Assistência à Saúde
3.
Eur Heart J Cardiovasc Imaging ; 15(9): 956-60, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24866902

RESUMO

The concept of point-of-care, problem-oriented focus cardiac ultrasound examination (FoCUS) is increasingly applied in the settings of medical emergencies, including cardiac diseases. The European Association of Cardiovascular Imaging (EACVI) recognizes that cardiologists are not the only medical professionals dealing with cardiovascular emergencies. In reality, emergency cardiac diagnostics and treatment are also carried out by a wide range of specialists. For the benefit of the patients, the EACVI encourages any medical professional, sufficiently trained to obtain valuable information from FoCUS, to use it in emergency settings. These medical professionals need to have the necessary knowledge to understand the obtained information entirely, and to use it correctly, thoughtfully and with care. In this document, the EACVI underlines major differences between echocardiography and FoCUS, and underscores the need for specific education and training in order to fully utilize advantages and minimize drawbacks of this type of cardiac ultrasound examination in the critically ill patients.


Assuntos
Cardiologia/normas , Estado Terminal , Ecocardiografia/normas , Emergências , Cardiopatias/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Cardiologia/educação , Humanos
4.
Eur J Cardiovasc Prev Rehabil ; 18(4): 650-5, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21450588

RESUMO

AIMS: Carotid intima-media thickness (IMT) is one of the best non-invasive parameters for evaluating previous vascular lesions and could be used to identify a preclinical stage of the atherosclerotic process. The aim of our research was to develop an epidemiological study of the normal mean values of IMT of the common carotid artery, adjusted for age and sex, in the Italian population. METHODS AND RESULTS: In this multicenter study, a total of 1017 patients (596 males, mean age: 58.5 + 13.2 years) were enrolled at four different Italian centers. Inclusion criteria were the absence of cardiovascular risk factors or presence of not more than one. Patients underwent two-dimensional echo-color Doppler scanning of the carotid arteries, adopting a high-definition vascular echographic apparatus and a 11-3 MHz linear electronic probe. The arithmetical mean of the IMT value was calculated. Data obtained from this study show the carotid IMT changes in relation to age and sex. In particular, it grows higher with increasing age, and is always higher in men than in women. CONCLUSION: In relation to the percentile distribution of the values in the population analyzed, the normal range of m-IMT could be established just on the basis of the patient's age and sex. In this way, the ultrasound scan operator can rely on a simple reference scheme. This will help to refine the use of carotid ultrasound as an excellent tool for detecting asymptomatic carotid alterations and patients at high risk for cerebral and cardiovascular disease.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/epidemiologia , Artéria Carótida Primitiva/diagnóstico por imagem , Túnica Íntima/diagnóstico por imagem , Túnica Média/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Adulto , Distribuição por Idade , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Envelhecimento , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Valores de Referência , Distribuição por Sexo , Fatores Sexuais , Adulto Jovem
5.
Angiology ; 61(5): 443-8, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20304865

RESUMO

The metabolic syndrome (MetS) has previously been associated with an early marker of atherosclerosis, the carotid intima-media thickness (IMT). From the ISMIR (Ispessimento Medio Intimale e Rischio cardiovascolare [media-intima thickness and cardiovascular risk]) study population of 479 asymptomatic participants, we identified 80 participants with MetS. Carotid IMT and plaques were evaluated by ultrasonography. Blood samples were obtained from all participants. Participants with MetS had a significantly higher prevalence of a carotid IMT > 0.80 mm (P = .004) and of carotid plaques (P < .001) as compared with participants without MetS. Carotid IMT was significantly correlated with fasting triglycerides and fibrinogen levels both in participants with MetS and in those without MetS (all P < .01). In contrast, IMT correlated with fasting plasma glucose, serum creatinine, and uric acid levels only in participants without MetS. Our study confirms the association between MetS and carotid atherosclerosis. In MetS, a significant correlation between carotid IMT and triglycerides and fibrinogen levels was found.


Assuntos
Doenças das Artérias Carótidas/diagnóstico , Síndrome Metabólica/diagnóstico , Idoso , Glicemia/metabolismo , Doenças das Artérias Carótidas/sangue , Doenças das Artérias Carótidas/patologia , Creatinina/sangue , Estudos Transversais , Feminino , Fibrinogênio/metabolismo , Humanos , Itália , Masculino , Síndrome Metabólica/sangue , Síndrome Metabólica/patologia , Pessoa de Meia-Idade , Fatores de Risco , Triglicerídeos/sangue , Túnica Íntima/patologia , Túnica Média/patologia , Ácido Úrico/sangue
7.
J Cardiovasc Med (Hagerstown) ; 7(7): 555-9, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16801817

RESUMO

In advanced countries the incidence of cardiovascular diseases is constantly increasing. During the last century many resources were employed to investigate atherosclerosis in relation to the main risk factors and to modification of lifestyles. Technologies have been developed to identify atherosclerosis in the sub-clinical phase. Measurement of the carotid intima-media thickness (IMT) by B-mode ultrasound is a well-validated procedure to detect the early stages of atherosclerosis and to track progression of atherosclerosis whereas other techniques have limited utility because of their invasive nature or limited sensitivity and reproducibility. In comparison with angiography, B-mode ultrasound has greater sensitivity for detecting early atherosclerosis and plaques at risk of rupture. IMT is associated with the severity of atherosclerosis in different vascular districts and has been measured in several clinical studies in order to assess the influence of risk factors, therapies and diet. It is also validated for drug evaluation. In spite of this evidence IMT measurement is not routinely performed in patients with high and middle levels of risk for cardiovascular diseases. Scientific societies and specifically those involved in ultrasonography should promote wider recognition of the diagnostic power of ultrasonic IMT by emphasizing the low costs and low risk of use of the instruments and its major contribution to knowledge, evaluation and monitoring of the progression of atherosclerosis.


Assuntos
Aterosclerose/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Túnica Íntima/diagnóstico por imagem , Artérias Carótidas/patologia , Doenças das Artérias Carótidas/patologia , Humanos , Fatores de Risco , Túnica Íntima/patologia , Ultrassonografia
8.
Ital Heart J Suppl ; 3(12): 1204-13, 2002 Dec.
Artigo em Italiano | MEDLINE | ID: mdl-12611211

RESUMO

The quality management of an organization can be defined as the ability to identify, plan and implement programs of measure, analysis, verification and control that allow to monitor management, resources, activities, processes and output/outcome of the same organization, including the satisfaction of the customers. Whatever the model used, it is demonstrated that the management-quality system, either for professional quality or for organization, turns out to be effective even in the health organizations within and to any level of organizational-structural complexity. The present paper concerns the experience of the Italian Society of Cardiovascular Echography (SIEC) on quality certification, both as a scientific society compared to other health organizations and to cardiovascular echo laboratories, and the definition of minimum requirements for the accreditation of the same laboratories. The model most frequently used for quality management is represented by the ISO 9000: Vision 2000, that is a management model with specific reference to the organization and the customer satisfaction. The model applied to the health structure needs a rapid change in mentality that addresses the operators to define, share and achieve objectives to be brought on by means of an active collaboration, group activity and deep sense of belonging necessary to the attainment of expected objectives. When the model is applied by a scientific society, it is necessary to take into account the different structural and functional organization, the constitution and the operators differing on the point of view of origin, experiences, mentality, and roles. The ISO 9000: Vision 2000 model can be applied also to the cardiovascular echo laboratory which may be compared to a simple organization; for its corrected functioning, SIEC has defined minimal requirements for the accreditation, realization and modalities to carry out and manage quality. The quality system represents a new way of operating of an organization that enhances capability and performance of the operators, stimulates their creativity and facilitates the activities of all, to guarantee both the quality of the product and the satisfaction of operators and customers at the same time.


Assuntos
Ecocardiografia/normas , Controle de Qualidade , Acreditação , Sistema Cardiovascular/diagnóstico por imagem , Humanos , Itália , Laboratórios/normas , Sociedades Científicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA