Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(1): 130-135, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37975539

RESUMO

INTRODUCTION: Cavo-tricuspid isthmus (CTI) dependent atrial flutter (AFL) is one of the most common atrial arrhythmias involving the right atrium (RA) for which radiofrequency catheter ablation has been widely used as a therapy of choice. However, there is limited data on the effect of this intervention on cardiac size and function. METHODS: A retrospective study was conducted on 468 patients who underwent ablation for CTI dependent typical AFL at a single institution between 2010 and 2019. After excluding patients with congenital or rheumatic heart disease, heart transplant recipients, or those without baseline echocardiogram, a total of 130 patients were included in the analysis. Echocardiographic data were analyzed at baseline before ablation, and at early follow-up within 1-year postablation. Follow-up echocardiographic data was available for 55 patients. RESULTS: Of the 55 patients with CTI-AFL, the mean age was 64.2 ± 14.8 years old with 14.5% (n = 8) female. The average left ventricular ejection fraction (LVEF) significantly improved on follow-up echo (40.2 ± 16.9 to 50.4 ± 14.9%, p < .0001), of which 50% of patients had an improvement in LVEF of at least 10%. There was a significant reduction in left atrial volume index (82.74 ± 28.5 to 72.96 ± 28 mL/m2 , p = .008) and RA volume index (70.62 ± 25.6 to 64.15 ± 31 mL/m2 , p = .046), and a significant improvement in left atrial reservoir strain (13.04 ± 6.8 to 19.10 ± 7.7, p < .0001). CONCLUSIONS: Patients who underwent CTI dependent AFL ablation showed an improvement in cardiac size and function at follow-up evaluation. While long-term results are still unknown, these findings indicate that restoration of sinus rhythm in patients with typical AFL is associated with improvement in atrial size and left ventricular function.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
2.
Front Immunol ; 14: 1159341, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37251390

RESUMO

Robust human immune system (HIS) mice are created using human fetal thymus tissue and hematopoietic stem cells (HSCs). A HIS mouse model using neonatal human thymus tissue and umbilical cord blood (CB) HSCs (NeoHu) was recently described. We improved the model by removing the native murine thymus, which can also generate human T cells, and demonstrated definitively the capacity of human T cells to develop in a grafted neonatal human thymus. Human T cells derived from the neonatal thymus tissue appeared in peripheral blood early post-transplantation and CB-derived T cells appeared later. Naïve T cells were demonstrated in peripheral blood but effector memory and T peripheral helper phenotypes predominated later, in association with development of autoimmunity in some animals. Treatment of thymus grafts with 2-deoxyglucose (2-DG) increased the proportion of stem cells derived from injected HSCs, delayed onset of autoimmune disease, reduced early T cell reconstitution, and reduced effector/memory T cell conversion. Younger neonatal human thymus tissue was associated with improved T cell reconstitution. While the NeoHu model bypasses the need for fetal tissue, it has yet to demonstrate equivalent reconstitution to fetal tissue, though 2-DG can improve results by removing native thymocytes prior to transplantation.


Assuntos
Sistema Imunitário , Timo , Humanos , Animais , Camundongos , Timócitos , Células-Tronco Hematopoéticas , Fenótipo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...