Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Prehosp Disaster Med ; 10(4): 232-7; discussion 237-8, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-10155435

RESUMO

INTRODUCTION: Previous evaluations of prehospital devices intended for spinal immobilization have focused on the device's ability to restrict motion only. This study defines six relevant criteria for evaluation of cervical immobilization device (CID) performance. OBJECTIVES: To suggest relevant criteria for evaluation and use available technology to improve measurements for performance testing of prehospital-care devices. METHODS: Six parameters (motion restriction, access, ease of application, environmental performance, radiolucency, and storage size) were used to evaluate three types of CIDs: Device A--a single-use corrugated board; Device B--a reusable foam-block CID; and Device C--hospital towels and adhesive tape. To test motion restriction, the most frequently compared parameters for immobilization devices, 20 volunteers were asked to move their heads and necks through a series of motions (flexion, extension, lateral bending, and rotation). Their movements were videotaped, still images of each movement were generated, and the degrees of deflection recorded from these still images. To ensure a consistent level of force, electromyography (EMG) of the sternoclydomastoid and extensor muscles was employed. RESULTS: Data were produced for each parameter and presented for comparison. The use of video to determine deflection proved to be a useful and highly accurate (+/- 1o) method for measurement. The use of EMG technology enabled force to be controlled indirectly when the subjects used moderate levels of exertion. Overall, Devices A and C restricted motion better than Device B. Although Device C required the shortest time for application, it took the longest to prepare for application. The total time required for preparation and application of A and B essentially were equivalent, with A requiring no preparation time but taking the longest for application, and B having an intermediate interval for application. Device A allowed for the best examination of the head and neck. No differences were detected in performance in extreme environmental conditions or in radiolucency for cervical spine X-ray examinations. Device A consumed the smallest storage volume, B the greatest storage volume, and C an intermediate volume substantially greater than that required for A. CONCLUSION: Device evaluation should include examination of all relevant performance parameters using the most accurate and meaningful methods possible.


Assuntos
Vértebras Cervicais/lesões , Serviços Médicos de Emergência/métodos , Imobilização , Aparelhos Ortopédicos , Amplitude de Movimento Articular , Vértebras Cervicais/fisiopatologia , Eletromiografia , Humanos , Fatores de Tempo , Gravação de Videoteipe
3.
JEMS ; 19(6): 34-8, 40-1, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10134428

RESUMO

A central theme for EMS systems is the reduction of death and disability from emergency illnesses and injuries, with most systems focusing exclusively on treatment to fulfill their missions. Unfortunately, this has often resulted in the neglect or complete disregard of prevention, which actually may be the more powerful intervention strategy. Yet hopefully, as EMS systems begin to learn and embrace the principles of continuous quality improvement (CQI) in their organizational cultures, the advantages of prevention vs. treatment will become more apparent and internally recognized.


Assuntos
Afogamento/epidemiologia , Afogamento/prevenção & controle , Serviços Médicos de Emergência/normas , Gestão da Qualidade Total/organização & administração , Coleta de Dados , Métodos Epidemiológicos , Florida/epidemiologia , Controle de Formulários e Registros , Humanos , Técnicas de Planejamento , Desenvolvimento de Programas/métodos , Relações Públicas , Sistema de Registros , Segurança , Piscinas/normas
4.
Ann Emerg Med ; 12(5): 330-2, 1983 May.
Artigo em Inglês | MEDLINE | ID: mdl-6625288
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...