Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Diabetes Metab Disord ; 22(1): 861-871, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37250371

RESUMO

Purpose: Open-source automated insulin delivery (AID) is used by thousands of people with type 1 diabetes (T1D), but has unknown generalisability to marginalised ethnic groups. This study explored experiences of Indigenous Maori participants in the CREATE trial with use of an open-source AID system to identify enablers/barriers to health equity. Methods: The CREATE randomised trial compared open-source AID (OpenAPS algorithm on an Android phone with a Bluetooth-connected pump) to sensor-augmented pump therapy. Kaupapa Maori Research methodology was used in this sub-study. Ten semi-structured interviews with Maori participants (5 children, 5 adults) and whanau (extended family) were completed. Interviews were recorded and transcribed, and data were analysed thematically. NVivo was used for descriptive and pattern coding. Results: Enablers/barriers to equity aligned with four themes: access (to diabetes technologies), training/support, operation (of open-source AID), and outcomes. Participants described a sense of empowerment, and improved quality of life, wellbeing, and glycaemia. Parents felt reassured by the system's ability to control glucose, and children were granted greater independence. Participants were able to use the open-source AID system with ease to suit whanau needs, and technical problems were manageable with healthcare professional support. All participants identified structures in the health system precluding equitable utilisation of diabetes technologies for Maori. Conclusion: Maori experienced open-source AID positively, and aspired to use this therapy; however, structural and socio-economic barriers to equity were identified. This research proposes strength-based solutions which should be considered in the redesign of diabetes services to improve health outcomes for Maori with T1D.Trial Registration: The CREATE trial, encompassing this qualitative sub-study, was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12620000034932p) on the 20th January 2020. Supplementary Information: The online version contains supplementary material available at 10.1007/s40200-023-01215-3.

2.
Diabetes Technol Ther ; 25(4): 250-259, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36763345

RESUMO

Aim: To assess long-term efficacy and safety of open-source automated insulin delivery (AID) in children and adults (7-70 years) with type 1 diabetes. Methods: Both arms of a 24-week randomized controlled trial comparing open-source AID (OpenAPS algorithm within a modified version of AndroidAPS, preproduction DANA-i™ insulin pump, Dexcom G6 continuous glucose monitor) with sensor-augmented pump therapy (SAPT), entered a 24-week continuation phase where the SAPT arm (termed SAPT-AID) crossed over to join the open-source AID arm (termed AID-AID). Most participants (69/94) used a preproduction YpsoPump® insulin pump during the continuation phase. Analyses incorporated all 52 weeks of data, and combined between-group and within-subject differences to calculate an overall "treatment effect" of AID versus SAPT. Results: Mean time in range (TIR; 3.9-10 mmol/L [70-180 mg/dL]) was 12.2% higher with AID than SAPT (95% confidence interval [CI] 10.4 to 14.1; P < 0.001). TIR was 56.9% (95% CI 54.2 to 59.6) with SAPT and 69.1% (95% CI 67.1 to 71.1) with AID. The treatment effect did not differ by age (P = 0.39) or insulin pump type (P = 0.37). HbA1c was 5.1 mmol/mol lower [0.5%] with AID (95% CI -6.6 to -3.6; P < 0.001). There were no episodes of diabetic ketoacidosis or severe hypoglycemia with either treatment over the 48 weeks. Six participants (all in SAPT-AID) withdrew: three with hardware issues, two preferred SAPT, and one with infusion-site skin irritation. Conclusion: Further evaluation of the community derived automated insulin delivery (CREATE) trial to 48 weeks confirms that open-source AID is efficacious and safe with different insulin pumps, and demonstrates sustained glycemic improvements without additional safety concerns.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Criança , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Hipoglicemia/induzido quimicamente , Glicemia , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina
3.
N Engl J Med ; 387(10): 869-881, 2022 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-36069869

RESUMO

BACKGROUND: Open-source automated insulin delivery (AID) systems are used by many patients with type 1 diabetes. Data are needed on the efficacy and safety of an open-source AID system. METHODS: In this multicenter, open-label, randomized, controlled trial, we assigned patients with type 1 diabetes in a 1:1 ratio to use an open-source AID system or a sensor-augmented insulin pump (control). The patients included both children (defined as 7 to 15 years of age) and adults (defined as 16 to 70 years of age). The AID system was a modified version of AndroidAPS 2.8 (with a standard OpenAPS 0.7.0 algorithm) paired with a preproduction DANA-i insulin pump and Dexcom G6 CGM, which has an Android smartphone application as the user interface. The primary outcome was the percentage of time in the target glucose range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter) between days 155 and 168 (the final 2 weeks of the trial). RESULTS: A total of 97 patients (48 children and 49 adults) underwent randomization (44 to open-source AID and 53 to the control group). At 24 weeks, the mean (±SD) time in the target range increased from 61.2±12.3% to 71.2±12.1% in the AID group and decreased from 57.7±14.3% to 54.5±16.0% in the control group (adjusted difference, 14 percentage points; 95% confidence interval, 9.2 to 18.8; P<0.001), with no treatment effect according to age (P = 0.56). Patients in the AID group spent 3 hours 21 minutes more in the target range per day than those in the control group. No severe hypoglycemia or diabetic ketoacidosis occurred in either group. Two patients in the AID group withdrew from the trial owing to connectivity issues. CONCLUSIONS: In children and adults with type 1 diabetes, the use of an open-source AID system resulted in a significantly higher percentage of time in the target glucose range than the use of a sensor-augmented insulin pump at 24 weeks. (Supported by the Health Research Council of New Zealand; Australian New Zealand Clinical Trials Registry number, ACTRN12620000034932.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Bombas de Infusão , Insulina , Adolescente , Adulto , Idoso , Austrália , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...