Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
2.
Pan Afr Med J ; 32: 13, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31143318

RESUMO

Scleroderma is a rare disease of unknown etiology, which is characterized by thickening and hardening of skin due to an increased collagen production. A 44-year-old female patient with a scleroderma on the scalp known by our department, also presented an ipsilateral brain lesion since 2015, which was showing growth without any clinical symptomatology and the patient wanted the lesion to be removed. This atypical lesion underneath the scleroderma shows that diagnosis can be missed without brain imaging and biopsy.


Assuntos
Hemangioma Cavernoso do Sistema Nervoso Central/diagnóstico , Couro Cabeludo/patologia , Esclerodermia Localizada/diagnóstico , Pele/patologia , Adulto , Biópsia/métodos , Colágeno/metabolismo , Feminino , Hemangioma Cavernoso do Sistema Nervoso Central/patologia , Humanos , Esclerodermia Localizada/patologia
4.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-822685

RESUMO

@#Angiomatoid fibrous histiocytoma (AFH) is a rare soft tissue tumour of uncertain differentiation and low metastatic potential, which occurs predominantly in children and young adults. It occurs mostly within the extremities, trunk, head and neck. We report the case of a 32-year-old female that was operated in our hospital in 2016 and twice in 2017. The patient had headaches and neck pain initially in 2016. We discuss the radiographic and histologic features initially found and the findings that ultimately led to the diagnosis of AFH. The patient had a past history of Hodgkin lymphoma.

5.
Clin Neurol Neurosurg ; 173: 163-168, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30144777

RESUMO

OBJECTIVE: Vitamin B12 deficiency can lead to subacute combined degeneration (SCD). Nitrous oxide (N2O) is an anesthetic which oxidizes the cobalt ion of vitamin B12, interfering with its function as a coenzyme. In this study, we conduct a systematic review of reported cases of SCD following nitrous oxide anesthesia. PATIENTS AND METHODS: A comprehensive search of multiple databases was conducted, and information about patient characteristics, symptomatology, clinical work-up, and treatment was extracted from eligible articles. Univariate analyses were performed to identify predictors of poor neurological recovery following SCD. RESULTS: 32 studies, reporting 37 cases of nitrous oxide-induced SCD, were included through the screening process. These cases included 21 male patients and 16 female patients, with an average age of 50.4 years (SD 17.6). An etiology for subclinical B12 deficiency was determined in 30 reports; of these, 25 were due to vitamin malabsorption secondary to a gastrointestinal disorder. Duration of nitrous oxide exposure was described in 19 reports, and ranged from 30 min to 11 h. Univariate analysis failed to find an association between post-operative recovery and age (p = 0.60), sex (p = 0.46), positive MRI findings (p = 0.47), post-operative serum B12 (p = 1.00), post-operative hemoglobin (p = 0.18), type of surgery (p = 0.58), or post-operative high mean corpuscular volume (p = 0.13). CONCLUSION: In patients with postsurgical myelopathy, surgeons should evaluate B12 status and consider the possibility that nitrous oxide could cause a subclinical B12 deficiency to become overt, particularly in patients with malabsorptive GI comorbidities. Treatment with B12 in this population can result in significant improvement of neurological function.


Assuntos
Óxido Nitroso/efeitos adversos , Medula Espinal/patologia , Degeneração Combinada Subaguda/complicações , Deficiência de Vitamina B 12/etiologia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Medula Espinal/metabolismo , Doenças da Medula Espinal/complicações , Degeneração Combinada Subaguda/patologia , Vitamina B 12/uso terapêutico , Deficiência de Vitamina B 12/diagnóstico
6.
J Neurosurg Spine ; 22(3): 237-45, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25555050

RESUMO

OBJECT: Although cervical total disc replacement (TDR) has shown equivalence or superiority to anterior cervical discectomy and fusion (ACDF), potential problems include nonphysiological motion (hypermobility), accelerated degeneration of the facet joints, particulate wear, and compromise of the mechanical integrity of the endplate during device fixation. Dynamic cervical stabilization is a novel motion-preserving concept that facilitates controlled, limited flexion and extension, but prevents axial rotation and lateral bending, thereby reducing motion across the facet joints. Shock absorption of the Dynamic Cervical Implant (DCI) device is intended to protect adjacent levels from accelerated degeneration. METHODS: The authors conducted a prospective evaluation of 53 consecutive patients who underwent DCI stabilization for the treatment of 1-level (n = 42), 2-level (n = 9), and 3-level (n = 2) cervical disc disease with radiculopathy or myelopathy. Forty-seven patients (89%) completed all clinical and radiographic outcomes at a minimum of 24 months. Clinical outcomes consisted of Neck Disability Index (NDI) and visual analog scale (VAS) scores, neurological function at baseline and at latest follow-up, as well as patient satisfaction. Flexion-extension radiography was evaluated for device motion, implant migration, subsidence, and heterotopic ossification. Cervical sagittal alignment (Cobb angle), functional spinal unit (FSU) angle, and range of motion (ROM) at index and adjacent levels were evaluated with WEB 1000 software. RESULTS: The NDI score, VAS neck and arm pain scores, and neurological deficits were significantly reduced at each postoperative time point compared with baseline (p < 0.0001). At 24 months postoperatively, 91% of patients were very satisfied and 9% somewhat satisfied, while 89% would definitely and 11% would probably elect to have the same surgery again. In 47 patients with 58 operated levels, the radiographic assessment showed good motion (5°-12°) of the device in 57%, reduced motion (2°-5°) in 34.5%, and little motion (0-2°) in 8.5%. The Cobb and FSU angles improved, showing a clear tendency for lordosis with the DCI. Motion greater than 2° of the treated segment could be preserved in 91.5%, while 8.5% had a near segmental fusion. Mean ROM at index levels demonstrated satisfying motion preservation with DCI. Mean ROM at upper and lower adjacent levels showed maintenance of adjacent-level kinematics. Heterotopic ossification, including 20% minor and 15% major, had no direct impact on clinical results. There were 2 endplate subsidences detected with an increased segmental lordosis. One asymptomatic anterior device migration required reoperation. Three patients underwent a secondary surgery in another segment during follow-up, twice for a new disc herniation and once for an adjacent degeneration. There was no posterior migration and no device breakage. CONCLUSIONS: Preliminary results indicate that the DCI implanted using a proper surgical technique is safe and facilitates excellent clinical outcomes, maintains index-and adjacent-level ROM in the majority of cases, improves sagittal alignment, and may be suitable for patients with facet arthrosis who would otherwise not be candidates for cervical TDR. Shock absorption together with maintained motion in the DCI may protect adjacent levels from early degeneration in longer follow-up.


Assuntos
Vértebras Cervicais/cirurgia , Descompressão Cirúrgica , Discotomia , Procedimentos Neurocirúrgicos , Substituição Total de Disco , Adulto , Idoso , Descompressão Cirúrgica/métodos , Discotomia/métodos , Feminino , Seguimentos , Humanos , Degeneração do Disco Intervertebral/diagnóstico , Degeneração do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/diagnóstico , Deslocamento do Disco Intervertebral/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próteses e Implantes , Reoperação , Fusão Vertebral/métodos , Substituição Total de Disco/métodos , Resultado do Tratamento
7.
Surg Neurol Int ; 5(Suppl 8): S413-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25289172

RESUMO

BACKGROUND: Progressive multifocal leukencephalopathy (PML) is a rare, sometimes fatal viral disease in patients with primary or secondary immunosuppression. CASE DESCRIPTION: A 57-year-old immunocompetent female with intractable Holmes tremor and elongated unique brainstem lesion reported to our hospital. The cerebrospinal fluid (CSF) screening for John Cunningham virus was negative and the diagnosis was established by brain biopsy. The course was rapidly fatal. CONCLUSION: This atypical presentation of PML in an immunocompetent patient illustrates that diagnosis can be missed without brain biopsy.

8.
J Vis Exp ; (90)2014 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-25226557

RESUMO

DTI is a technique that identifies white matter tracts (WMT) non-invasively in healthy and non-healthy patients using diffusion measurements. Similar to visual pathways (VP), WMT are not visible with classical MRI or intra-operatively with microscope. DIT will help neurosurgeons to prevent destruction of the VP while removing lesions adjacent to this WMT. We have performed DTI on fifty patients before and after surgery between March 2012 to January 2014. To navigate we used a 3DT1-weighted sequence. Additionally, we performed a T2-weighted and DTI-sequences. The parameters used were, FOV: 200 x 200 mm, slice thickness: 2 mm, and acquisition matrix: 96 x 96 yielding nearly isotropic voxels of 2 x 2 x 2 mm. Axial MRI was carried out using a 32 gradient direction and one b0-image. We used Echo-Planar-Imaging (EPI) and ASSET parallel imaging with an acceleration factor of 2 and b-value of 800 s/mm². The scanning time was less than 9 min. The DTI-data obtained were processed using a FDA approved surgical navigation system program which uses a straightforward fiber-tracking approach known as fiber assignment by continuous tracking (FACT). This is based on the propagation of lines between regions of interest (ROI) which is defined by a physician. A maximum angle of 50, FA start value of 0.10 and ADC stop value of 0.20 mm²/s were the parameters used for tractography. There are some limitations to this technique. The limited acquisition time frame enforces trade-offs in the image quality. Another important point not to be neglected is the brain shift during surgery. As for the latter intra-operative MRI might be helpful. Furthermore the risk of false positive or false negative tracts needs to be taken into account which might compromise the final results.


Assuntos
Imagem de Tensor de Difusão/instrumentação , Imagem de Tensor de Difusão/métodos , Procedimentos Neurocirúrgicos/métodos , Vias Visuais/fisiologia , Vias Visuais/cirurgia , Substância Branca/fisiologia , Substância Branca/cirurgia , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/cirurgia , Imagem de Tensor de Difusão/normas , Glioblastoma/diagnóstico , Glioblastoma/cirurgia , Humanos , Recidiva Local de Neoplasia/diagnóstico , Software , Vias Visuais/anatomia & histologia , Substância Branca/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...