Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Integr Neurosci ; 23(5): 93, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38812381

RESUMO

BACKGROUND: Magnetoencephalography (MEG) is a non-invasive imaging technique for directly measuring the external magnetic field generated from synchronously activated pyramidal neurons in the brain. The optically pumped magnetometer (OPM) is known for its less expensive, non-cryogenic, movable and user-friendly custom-design provides the potential for a change in functional neuroimaging based on MEG. METHODS: An array of OPMs covering the opposite sides of a subject's head is placed inside a magnetically shielded room (MSR) and responses evoked from the auditory cortices are measured. RESULTS: High signal-to-noise ratio auditory evoked response fields (AEFs) were detected by a wearable OPM-MEG system in a MSR, for which a flexible helmet was specially designed to minimize the sensor-to-head distance, along with a set of bi-planar coils developed for background field and gradient nulling. Neuronal current sources activated in AEF experiments were localized and the auditory cortices showed the highest activities. Performance of the hybrid optically pumped magnetometer-magnetoencephalography/electroencephalography (OPM-MEG/EEG) system was also assessed. CONCLUSIONS: The multi-channel OPM-MEG system performs well in a custom built MSR equipped with bi-planar coils and detects human AEFs with a flexible helmet. Moreover, the similarities and differences of auditory evoked potentials (AEPs) and AEFs are discussed, while the operation of OPM-MEG sensors in conjunction with EEG electrodes provides an encouraging combination for the exploration of hybrid OPM-MEG/EEG systems.


Assuntos
Córtex Auditivo , Eletroencefalografia , Potenciais Evocados Auditivos , Magnetoencefalografia , Humanos , Magnetoencefalografia/instrumentação , Potenciais Evocados Auditivos/fisiologia , Córtex Auditivo/fisiologia , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Adulto , Masculino
2.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38663840

RESUMO

INTRODUCTION AND OBJECTIVES: The aim of this study was to explore the potential of adhering to the American Heart Association's updated Life's Essential 8 (LE8) scores in delaying biological aging amid growing concerns about aging populations and related diseases. METHODS: A total of 18 261 adults (≥ 20 years old) were examined using National Health and Nutrition Examination Survey data from 2005-2010 and 2015-2018. The LE8 includes 8 components, covering health behaviors and factors. Acceleration of biological aging was defined as an excess of biological/phenotypic age over chronological age, assessed by using clinical biomarkers. The association between LE8 score and biological aging was explored through regression analyses. RESULTS: Each 10-point increase in LE8 scores was associated with a 1.19-year decrease in biological age and a 1.63-year decrease in phenotypic age. Individuals with high cardiovascular health (CVH) had a 90% reduction in their risk of accelerated aging based on biological age and an 81% reduction based on phenotypic age compared with individuals with low CVH. Bootstrap-based model estimates and weighted quantile sum regression suggested that health factors, particularly blood glucose, had strong impact on delaying aging. The association between smoking and biological aging seemed to differ depending on the definition of aging used. Among all subgroups, LE8 consistently correlated negatively with biological aging, despite observed interactions. Three sensitivity analyses confirmed the robustness of our conclusions. CONCLUSIONS: A higher CVH is associated with a lower risk of biological aging. Maintaining elevated LE8 levels across demographics, regardless of cardiovascular history, is recommended to delay aging and promote healthy aging, with significant implications for primary health care.

3.
PLoS One ; 15(9): e0239632, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32970749

RESUMO

In recent years, there has been growing concern among consumers about pesticide contamination in fruits. Therefore, rapid, reliable, and consistent detection methods for OPPs, especially dimethoate, are crucially needed. The existing quantitative methods for detecting dimethoate are not suitable for rapid measuring system such as the dimethoate samples from two channels. Hence this paper examines the utilization of a dual-channel system for utilize the absorption variations of the Localized Surface Plasmon Resonance (LSPR) bands of gold nanoparticles (AuNPs) were investigate for detection of dimethoate. Under optimized conditions, the relationship between concentrations of dimethoate and absorbance ratios (A(520)/A(640)) was linearly found in the concentration range of 10-100 nM. Result from the experiment shows that both channels exhibit a linear correlation coefficient as high as 0.97 and a limit of detection (LOD) as low as 5.5 nM. This LSPR detection system was characterized by testing the dimethoate in apple samples and the recovery rates were found to be in the range of 85.90% to 107.37%. The proposed dual-channel LSPR system for detecting dimethoate creating a new approach for detecting organophosphate insecticide in agricultural fields. It could lay the foundation for designing a high-throughput analysis of the insecticides using a wavelength division multiplexing switch (WDMS).


Assuntos
Produtos Agrícolas/normas , Dimetoato/análise , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Frutas/normas , Inseticidas/análise , Ressonância de Plasmônio de Superfície/métodos , Produtos Agrícolas/química , Análise de Alimentos/normas , Frutas/química , Sensibilidade e Especificidade , Ressonância de Plasmônio de Superfície/normas
4.
J Neurosci Methods ; 346: 108948, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32950554

RESUMO

BACKGROUND: Magnetoencephalography (MEG) has high temporal and spatial resolution and good spatial accuracy in determining the locations of source activity among most non-invasive imaging. The recently developed technology of optically-pumped magnetometer (OPM) has sensitivity comparable to that of the superconducting quantum interference device (SQUID) used in commercial MEG system. NEW METHOD: Double-channel OPM-MEG system detects human photic blocking of alpha rhythm at the occipital region of skull in the magnetically shielded environment via a wearable whole-cortex 3D-printed helmet. RESULTS: The alpha rhythm can be detected by the OPM-MEG system, the MEG signals are undoubtedly caused by photic blocking and similar with the results measured by SQUID magnetometer. COMPARISON WITH EXISTING METHODS: Due to the dependency of current commercial whole-cortex SQUID-MEG system on the liquid helium, the separation from the liquid helium space to the human head is usually at least a few centimeters. The wearable OPM-MEG system, however, can significantly improve the detection efficiency since its sensors can be mounted close to scalp, normally less than 1 cm. CONCLUSIONS: OPM-MEG system successfully detects alpha rhythm blocked by light stimulation and works well in the home-made magnetically shielded environment. OPM-MEG system shows a substitute for the traditional MEG system.


Assuntos
Magnetoencefalografia , Lobo Occipital , Ritmo alfa , Córtex Cerebral , Humanos , Couro Cabeludo
5.
Sensors (Basel) ; 18(6)2018 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-29882796

RESUMO

Corn stalk lodging is caused by different factors, including severe wind storms, stalk cannibalization, and stalk rots, and it leads to yield loss. Determining how to rapidly evaluate corn lodging resistance will assist scientists in the field of crop breeding to understand the contributing factors in managing the moisture, chemical fertilizer, and weather conditions for corn growing. This study proposes a non-destructive and direction-insensitive method, using a strain sensor and two single axis angle sensors to measure the corn stalk lodging resistance in the field. An equivalent force whose direction is perpendicular to the stalk is utilized to evaluate the corn lodging properties when a pull force is applied on the corn stalk. A novel measurement device is designed to obtain the equivalent force with the coefficient of variation (CV) of 4.85%. Five corn varieties with two different planting densities are arranged to conduct the experiment using the novel measurement device. The experimental results show that the maximum equivalent force could reach up to 44 N. A strong relationship with the square of the correlation coefficient of 0.88 was obtained between the maximum equivalent forces and the corn field’s stalk lodging rates. Moreover, the stalk lodging angles corresponding to the different pull forces over a measurement time of 20 s shift monotonically along the equivalent forces. Thus, the non-destructive and direction-insensitive method is an excellent tool for rapid analysis of stalk lodging resistance in corn, providing critical information on in-situ lodging dynamics.

6.
Appl Spectrosc ; 72(6): 913-920, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29512412

RESUMO

Paper aging and degradation are growing concerns for those who are responsible for the conservation of documents, archives, and libraries. In this study, the paper aging was investigated using laser-induced fluorescence spectroscopy (LIFS), where the fluorescence properties of 47 paper samples with different ages were explored. The paper exhibits fluorescence in the blue-green spectral region with two peaks at about 448 nm and 480 nm under the excitation of 405 nm laser. Both fluorescence peaks changed in absolute intensities and thus the ratio of peak intensities was also influenced with the increasing ages. By applying principal component analysis (PCA) and k-means clustering algorithm, all 47 paper samples were classified into nine groups based on the differences in paper age. Then the first-derivative fluorescence spectral curves were proposed to figure out the relationship between the spectral characteristic and the paper age, and two quantitative models were established based on the changes of first-derivative spectral peak at 443 nm, where one is an exponential fitting curve with an R-squared value of 0.99 and another is a linear fitting curve with an R-squared value of 0.88. The results demonstrated that the combination of fluorescence spectroscopy and PCA can be used for the classification of paper samples with different ages. Moreover, the first-derivative fluorescence spectral curves can be used to quantitatively evaluate the age-related changes of paper samples.

7.
PLoS One ; 12(9): e0185530, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28953934

RESUMO

Abscisic acid (ABA) plays an important role in abiotic stress response and physiological signal transduction resisting to the adverse environment. Therefore, it is very essential for the quantitative detection of abscisic acid (ABA) due to its indispensable role in plant physiological activities. Herein, a new detection method based on localized surface plasmon resonance (LSPR) using aptamer-functionalized gold nanoparticles (AuNPs) is developed without using expensive instrument and antibody. In the presence of ABA, ABA specifically bind with their aptamers to form the ABA-aptamer complexes with G-quadruplex-like structure and lose the ability to stabilize AuNPs against NaCl-induced aggregation. Meanwhile, the changes of the LSPR spectra of AuNP solution occur and therefore the detection of ABA achieved. Under optimized conditions, this method showed a good linear range covering from 5×10-7 M to 5×10-5 M with a detection limit of 0.33 µM. In practice, the usage of this novel method has been demonstrated by its application to detect ABA from fresh leaves of rice with the relative error of 6.59%-7.93% compared with ELISA bioassay. The experimental results confirmed that this LSPR-based biosensor is simple, selective and sensitive for the detection of ABA. The proposed LSPR method could offer a new analytical platform for the detection of other plant hormones by changing the corresponding aptamer.


Assuntos
Ácido Abscísico/análise , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais , Ouro/química , Nanopartículas/química , Ressonância de Plasmônio de Superfície/métodos , Ensaio de Imunoadsorção Enzimática , Limite de Detecção , Microscopia Eletrônica de Transmissão
8.
PLoS One ; 12(5): e0177131, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28475597

RESUMO

A biosensing system with optical fibers is proposed for the colorimetric detection of melamine in liquid milk samples by using the localized surface plasmon resonance (LSPR) of unmodified gold nanoparticles (AuNPs). The biosensing system consists of a broadband light source that covers the spectral range from 200 nm to 1700 nm, an optical attenuator, three types of 600 µm premium optical fibers with SMA905 connectors and a miniature spectrometer with a linear charge coupled device (CCD) array. The biosensing system with optical fibers is low-cost, simple and is well-proven for the detection of melamine. Its working principle is based on the color changes of AuNPs solution from wine-red to blue due to the inter-particle coupling effect that causes the shifts of wavelength and absorbance in LSPR band after the to-be-measured melamine samples were added. Under the optimized conditions, the detection response of the LSPR biosensing system was found to be linear in melamine detection in the concentration range from 0µM to 0.9 µM with a correlation coefficient (R2) 0.99 and a detection limit 33 nM. The experimental results obtained from the established LSPR biosensing system in the actual detection of melamine concentration in liquid milk samples show that this technique is highly specific and sensitive and would have a huge application prospects.


Assuntos
Colorimetria/métodos , Contaminação de Alimentos/análise , Ouro , Nanopartículas Metálicas , Leite/química , Triazinas/análise , Animais , Fibras Ópticas
9.
Sensors (Basel) ; 16(11)2016 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-27827923

RESUMO

The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 using the SPR immunoassay, 3-mercaptopropionic acid (3-MPA) was chemisorbed onto a gold surface via covalent bond for the immobilization of biological species. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were used as crosslinker reagents to enable the reaction between 3-MPA and Escherichia coli O157:H7 antibodies by covalent -CO-NH- amide bonding. The experimental results were obtained from the Escherichia coli O157:H7 positive samples prepared by 10-, 20-, 40-, 80-, and 160-fold dilution respectively, which show that a good linear relationship with the correlation coefficient R of 0.982 existed between the response units from the portable SPR bioanalyzer and the concentration of Escherichia coli O157:H7 positive samples. Moreover, the theoretical detection limit of 1.87 × 10³ cfu/mL was calculated from the positive control samples. Compared with the Escherichia coli O157:H7 ELISA kit, the sensitivity of this portable SPR bioanalyzer is four orders of magnitude higher than the ELISA kit. The results demonstrate that the portable SPR bioanalyzer could provide an alternative method for the quantitative and sensitive determination of Escherichia coli O157:H7 in field.


Assuntos
Técnicas Biossensoriais/métodos , Ressonância de Plasmônio de Superfície/métodos , Ensaio de Imunoadsorção Enzimática , Escherichia coli O157/fisiologia , Imunoensaio/métodos , Succinimidas
10.
Sensors (Basel) ; 16(4)2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27070614

RESUMO

Ethylene as an indicator for evaluating fruit ripening can be measured by very sensitive electrochemical gas sensors based on a high-resolution current produced by a bias potential applied to the electrodes. For this purpose, a measurement system for monitoring ethylene gas concentrations to evaluate fruit ripening by using the electrochemical ethylene sensor was successfully developed. Before the electrochemical ethylene sensor was used to measure the ethylene gas concentrations released from fruits, a calibration curve was established by the standard ethylene gases at concentrations of 2.99 ppm, 4.99 ppm, 8.01 ppm and 10 ppm, respectively, with a flow rate of 0.4 L·min(-1). From the calibration curve, the linear relationship between the responses and concentrations of ethylene gas was obtained in the range of 0-10 ppm with the correlation coefficient R² of 0.9976. The micropump and a novel signal conditioning circuit were implemented in this measurement, resulting in a rapid response in detecting ethylene concentrations down to 0.1 ppm in air and in under 50 s. In this experiment, three kinds of fruits-apples, pears and kiwifruits-were studied at a low concentration (under 0.8 ppm) of trace ethylene content in the air exhaled by fruits. The experimental results showed that a low cost, compact measurement system constructed by using an electrochemical ethylene sensor has a high sensitivity of 0.3907 V·ppm(-1) with a theoretical detection limit of 0.413 ppm, and is non-invasive and highly portable.


Assuntos
Técnicas Biossensoriais/instrumentação , Etilenos/isolamento & purificação , Frutas/crescimento & desenvolvimento , Gases/isolamento & purificação , Técnicas Eletroquímicas , Etilenos/metabolismo , Frutas/química , Frutas/metabolismo , Gases/metabolismo , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...