Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Transl Med ; 20(1): 354, 2022 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-35962454

RESUMO

OBJECTIVE: To compare efficacy and safety of fecal microbiota transplantation (FMT) with glucocorticoid as induction therapy in ulcerative colitis (UC). METHODS: The patients with active mild to moderate UC were recruited into the single-center, prospective cohort study. The patients were treated with either FMT (FMT group) or glucocorticoids (GCs group). Patients received FMT administration for 3 days. The primary outcome was clinical and endoscopic remission at week 12. Inflammatory parameters were assessed by routine blood tests. Safety was assessed by adverse events recorded. The serum levels of TNF-α, IFN-γ, IL-1ß, IL-4, IL-5, IL-6, IL-10 IL-8, IL-12p70, IL-13, IL-17A and IL-23 following FMT were measured by Luminex multiplex assay. RESULTS: Of the 122 patients, 62 patients were treated with FMT and 60 with glucocorticoids. 34 patients in FMT group (54.8%) and 29 in GCs group (48.3%) reached the primary outcome (p = 0.30). The incidence of adverse events in GCs group (35/60, 58.3%) was significantly higher than that in FMT group (14/62, 22.6%) and two serious adverse events were observed following GCs. Patients in FMT group were stratified into responders (RE) and non-responders (NR) groups. The level of TNF-α and IL-6 decreased significantly in RE group, while IL-10 decreased significantly in NR group. CONCLUSION: FMT therapy was as effective as glucocorticoids to induce remission in active mild to moderate UC, accompanied by fewer adverse events. The modification of serum TNF-α, IL-6 and IL-10 might be related to the efficacy of FMT in UC. Trial registration This study was registered with ClinicalTrials.gov (NCT02435160). Registered on 6 April, 2015. https://clinicaltrials.gov/ct2/results?cond=&term=NCT02435160&cntry=&state=&city=&dist=.


Assuntos
Colite Ulcerativa , Transplante de Microbiota Fecal , Colite Ulcerativa/terapia , Transplante de Microbiota Fecal/efeitos adversos , Transplante de Microbiota Fecal/métodos , Glucocorticoides/uso terapêutico , Humanos , Interleucina-10 , Interleucina-6 , Estudos Prospectivos , Indução de Remissão , Resultado do Tratamento , Fator de Necrose Tumoral alfa
2.
Asian J Androl ; 23(4): 396-399, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33565428

RESUMO

Optimal vision and ergonomics are essential factors contributing to the achievement of good results during microsurgery. The three-dimensional (3D) digital image microscope system with a better 3D depth of field can release strain on the surgeon's neck and back, which can improve outcomes in microsurgery. We report a randomized prospective study of vasoepididymostomy and vasovasostomy using a 3D digital image microscope system (3D-DIM) in rats. A total of 16 adult male rats were randomly divided into two groups of 8 each: the standard operating microscope (SOM) group and the 3D-DIM group. The outcomes measured included the operative time, real-time postoperative mechanical patency, and anastomosis leakage. Furthermore, a user-friendly microscope score was designed to evaluate the ergonomic design and equipment characteristics of the microscope. There were no differences in operative time between the two groups. The real-time postoperative mechanical patency rates were 100.0% for both groups. The percentage of vasoepididymostomy anastomosis leakage was 16.7% in the SOM group and 25.0% in the 3D-DIM group; however, no vasovasostomy anastomosis leakage was found in either group. In terms of the ergonomic design, the 3D-DIM group obtained better scores based on the surgeon's feelings; in terms of the equipment characteristics, the 3D-DIM group had lower scores for clarity and higher scores for flexibility and adaptivity. Based on our randomized prospective study in a rat model, we believe that the 3D-DIM can improve surgeon comfort without compromising outcomes in male infertility reconstructive microsurgery, so the 3D-DIM might be widely used in the future.


Assuntos
Microcirurgia/normas , Vasovasostomia/instrumentação , Animais , Modelos Animais de Doenças , Microscopia de Vídeo/instrumentação , Microscopia de Vídeo/métodos , Microcirurgia/métodos , Microcirurgia/estatística & dados numéricos , Ratos , Ratos Sprague-Dawley , Vasovasostomia/métodos
3.
J Cancer ; 8(17): 3448-3455, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29151928

RESUMO

Objective To determine the prognostic utility of serum pre-albumin in metastatic castration-resistant prostate cancer (mCRPC) patients treated with abiraterone (AA). Patients and Methods 112 chemotherapy pretreated or chemotherapy-naive patients were scheduled for systemic treatment with AA. Serum pre-albumin levels were measured before and after 3 months of AA treatment. Univariate and multivariate analyses were performed to determine prognostic factors that were associated with PSA progression-free survival (PSA-PFS), radiographic PFS (rPFS) and overall survival (OS). The Harrell concordance index with variables only or combined pre-albumin data were used to evaluate the prognostic accuracy. Results The group of patients with baseline pre-albumin value ≥20mg/dL had a longer OS, PSA-PFS, rPFS than those with pre-albumin value <20mg/dL. Based on the values of pre-albumin before and after 3 months of AA treatment, we divided these patients into 4 groups: high-high, high-low, low-high and low-low group. High- high group showed a significantly better OS, PSA-PFS, rPFS than other 3 groups. In multivariate analysis, low pre-albumin level remained significant predictors of OS (HR, 13.2; P<0.001), rPFS (HR, 3.7; P=0.003) and PSA-PFS (HR, 8.7; P<0.001). The estimated c-index of the multivariate model for OS increased from 0.814 without pre-albumin to 0.845 when pre-albumin added. Conclusion Low pretreatment serum pre-albumin is a negative independent prognosticator of survival outcomes in mCRPC treated with AA and also increases the accuracy of established prognostic model. Serial pre-albumin evaluation might help clinicians guide clinical treatment of mCRPC patients.

4.
ACS Appl Mater Interfaces ; 9(46): 39901-39906, 2017 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-29120160

RESUMO

Monodisperse hydrophilic quantum dots (QDs) are promising labeling materials for biomedical applications. However, the controllable preparation of monodisperse hydrophilic QDs with amphiphilic polymers remains a challenge. Herein, the molecular structures of amphiphilic polymers assembled on different-sized QDs are investigated. Both the experimental results and the molecular dynamics (MD) calculation suggest that the grafting ratio of amphiphilic polymers assembled on QDs increases as the size of QDs increases. Thus, the controllable preparation of different-sized monodisperse hydrophilic QDs can be achieved by simply varying the grafting ratio of amphiphilic molecules and applied in the simultaneous labeling of three tumor biomarkers.

5.
Sci Transl Med ; 9(387)2017 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-28446682

RESUMO

With the increasingly dominant role of smartphones in our lives, mobile health care systems integrating advanced point-of-care technologies to manage chronic diseases are gaining attention. Using a multidisciplinary design principle coupling electrical engineering, software development, and synthetic biology, we have engineered a technological infrastructure enabling the smartphone-assisted semiautomatic treatment of diabetes in mice. A custom-designed home server SmartController was programmed to process wireless signals, enabling a smartphone to regulate hormone production by optically engineered cells implanted in diabetic mice via a far-red light (FRL)-responsive optogenetic interface. To develop this wireless controller network, we designed and implanted hydrogel capsules carrying both engineered cells and wirelessly powered FRL LEDs (light-emitting diodes). In vivo production of a short variant of human glucagon-like peptide 1 (shGLP-1) or mouse insulin by the engineered cells in the hydrogel could be remotely controlled by smartphone programs or a custom-engineered Bluetooth-active glucometer in a semiautomatic, glucose-dependent manner. By combining electronic device-generated digital signals with optogenetically engineered cells, this study provides a step toward translating cell-based therapies into the clinic.


Assuntos
Glucose/metabolismo , Smartphone , Animais , Engenharia Celular , Diabetes Mellitus/metabolismo , Peptídeo 1 Semelhante ao Glucagon/metabolismo , Humanos , Camundongos
6.
Lasers Med Sci ; 30(3): 1147-51, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25698433

RESUMO

This study aims to compare long-term results of photoselective vaporization of the prostate (PVP) with an 80-W potassium titanyl phosphate (KTP) laser and monopolar transurethral resection of the prostate (TURP) in terms of efficacy, durability, and safety in an adjusted patient population. This prospective, non-randomized bi-center study included 120 (PVP) and 68 (TURP) patients in each arm. Patients were evaluated at 60 months of follow-up. Data from 30 (PVP) and 31 (TURP) patients were available for analysis. The primary outcome measurement was the International Prostate Symptom Score (IPSS) at 5 years. Secondary outcome measurements included voiding symptoms (quality of life (QoL) score), micturition parameters (maximal flow rate, Q max), post-void residual (PVR) volume, prostate-specific antigen (PSA) value, and reoperation rate. At study inclusion, voiding symptoms and micturition parameters were comparable between both groups. Age, prostate volume, and the proportion of patients with platelet aggregation inhibition or oral anticoagulation were significantly higher in the PVP group. No significant difference could be detected between patients available at 60 months and those lost to follow-up in terms of preoperative characteristics in either group. Sixty months postoperatively, the improvement of IPSS, QoL, Q max, and PVR volume showed no significant difference between both groups. PSA reduction was significantly higher after TURP. The reoperation rate due to urethral stricture (PVP, 13 %; TURP, none), bladder neck contracture (PVP, 3 %; TURP, none), and persisting or recurrent adenoma (PVP, 18 %; TURP, 3 %) was significantly higher after the 80-W PVP. Eighty-watt PVP leads to comparable functional outcomes to TURP. However, during a long-term follow-up, significantly more reoperations are necessary after PVP with the 80-W KTP laser, suggesting inferior tissue ablation capacity of the 80-W KTP laser.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática/cirurgia , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Antígeno Prostático Específico/sangue , Hiperplasia Prostática/sangue , Qualidade de Vida , Ressecção Transuretral da Próstata , Resultado do Tratamento
7.
J Endourol ; 29(4): 449-54, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25290572

RESUMO

BACKGROUND AND OBJECTIVE: Laser vaporization of the prostate is one of the alternatives to transurethral resection of the prostate. Short-term studies report a comparable outcome after laser vaporization with the 532 nm 120-W GreenLight high-performance system (HPS) laser and the 980 nm 200 W high-intensity diode (diode) laser. In this study, we analyzed the intermediate-term results of both techniques. MATERIALS AND METHODS: From January 2007 to January 2008, 112 consecutive patients with symptomatic benign prostate enlargement were nonrandomly assigned to treatment with the GreenLight laser or the diode laser. Perioperative parameters, postoperative functional outcome, complications, and the reoperation rate at 3 years were analyzed. RESULTS: Improvement of voiding symptoms (International Prostate Symptom Score, quality-of-life) and micturition parameters (maximum flow rate, postvoid residual volume) showed no significant difference between the HPS group and the diode group. A significantly higher reoperation rate was observed in the diode group in comparison to the HPS group (37.5% vs 8.9%, p=0.0003) due to obstructive necrotic tissue (16.1% vs 0%, p=0.0018), bladder neck stricture (16.1% vs 1.8%, p=0.008), and persisting or recurrent adenoma (5.4% vs 7.1%, p=0.70), respectively. CONCLUSIONS: Both lasers lead to comparable improvement of voiding parameters and micturition symptoms. Treatment with the 200 W diode laser led to a significantly higher reoperation rate, which might be attributed to a higher degree of coagulation necrosis. Thus, a careful clinical application of this diode laser type is warranted.


Assuntos
Terapia a Laser/métodos , Lasers Semicondutores/uso terapêutico , Próstata/cirurgia , Hiperplasia Prostática/cirurgia , Ressecção Transuretral da Próstata/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Necrose/cirurgia , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Próstata/patologia , Reoperação , Resultado do Tratamento
8.
World J Urol ; 28(2): 157-61, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20306053

RESUMO

OBJECTIVES: To evaluate the efficacy and safety of 2 micron continuous wave laser resection of non-muscle-invasive bladder tumor (NMIBT) compared with holmium laser resection of bladder tumor (HoLRBT) and standard transurethral resection of bladder tumor (TURBT). METHODS: Since April 2006 to August 2007, 97 patients with NMIBT were retrospectively collected in this study. All of them were classified into 3 groups, which were treated with 2 micron continuous wave laser resection, holmium laser resection and TURBT, respectively. The preoperative, intraoperative and postoperative clinical data were recorded and compared using SAS 6.12 statistical software. RESULTS: There were no differences with the preoperative characteristics among the three groups, except the diameter of the tumors. The maximum diameter of the tumors in 2 micron laser group was larger than the other two groups (P < 0.05). Two micron laser group was associated with less hemoglobin decrease compared with TURBT group (P < 0.05). All of the patients were followed and the recurrence rate of the three groups indicated no statistical significance (P > 0.05). CONCLUSIONS: In conclusion, 2 micron continuous wave laser resection of non-muscle-invasive bladder tumor is a safe and reliable treatment. With the distinguished hemostasis, it is an available optional treatment.


Assuntos
Terapia a Laser/instrumentação , Lasers de Estado Sólido , Lasers , Neoplasias da Bexiga Urinária/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Terapia a Laser/métodos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Invasividade Neoplásica , Recidiva Local de Neoplasia/epidemiologia , Estadiamento de Neoplasias , Estudos Retrospectivos , Fatores de Risco , Neoplasias da Bexiga Urinária/epidemiologia , Neoplasias da Bexiga Urinária/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...