Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanotechnology ; 23(12): 125704, 2012 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-22407131

RESUMO

A multidimensional scanning probe microscopy approach for quantitative, cross-talk free mapping of surface electrostatic properties is demonstrated. Open-loop band excitation Kelvin probe force microscopy (OL BE KPFM) probes the full response-frequency-potential surface at each pixel at standard imaging rates. The subsequent analysis reconstructs work function, tip-surface capacitance gradient and resonant frequency maps, obviating feedback-related artifacts. OL BE KPFM imaging is demonstrated for several materials systems with topographic, potential and combined contrast. This approach combines the features of both frequency and amplitude KPFM and allows complete decoupling of topographic and voltage contributions to the KPFM signal.

2.
Small ; 8(8): 1264-9, 2012 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-22334564

RESUMO

The cantilever dynamics in single-frequency scanning probe microscopy (SPM) are undefined due to having only two output variables, which leads to poorly understood image contrast. To address this shortcoming, generalized phase imaging scanning probe microscopy (GP-SPM), based on broad band detection and multi-eigenmode operation, is developed and demonstrated on diamond nanoparticles with different functionalization layers. It is shown that rich information on tip-surface interactions can be acquired by separating the response amplitude, instant resonance frequency, and quality factor. The obtained data allow high-resolution imaging even in the ambient environment. By tuning the strength of tip-surface interaction, different surface functionalizations can be discerned.


Assuntos
Microscopia de Força Atômica/métodos , Microscopia de Varredura por Sonda/métodos
3.
J Am Chem Soc ; 132(28): 9681-7, 2010 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-20583795

RESUMO

Substantial experimental evidence indicates that the mechanical force applied to pull apart non-covalent molecular bonds (such as receptor-ligand pairs) can significantly decrease the bond lifetime. This evidence is often generated in single-molecule experiments that are designed to specifically test effects of pulling forces. However, the effect of compressive forces on the lifetime of receptor-ligand bonds remains largely unexplored. Here we extend the common usage of the atomic force microscopy technique to study whether compressive forces applied to bound streptavidin-biotin species can significantly accelerate the rate of dissociation. Presented experimental data indicate that compressive forces can substantially decrease the lifetime of the molecular bond. Surprisingly, the efficiency of accelerating dissociation by compressive forces sometimes exceeds the enhancement of the dissociation rate measured in pulling experiments, indicating that compressive forces applied to the bound species might be efficiently used to control the lifetime of adhesion bonds.


Assuntos
Proteínas/metabolismo , Receptores de Superfície Celular/metabolismo , Ligantes , Microscopia de Força Atômica
4.
Langmuir ; 26(14): 11951-7, 2010 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-20496933

RESUMO

The detection probability of rupture events in AFM force spectroscopy measurements presents a viable alternative to standard methods for extracting kinetic parameters of dissociation. The detection probability has a maximum as a function of the probe velocity where (1) the probability to form a molecular bond is independent of the probe velocity and (2) the detection of rupture events is limited by noise and performed with a constant density of data points per distance of the probe displacement. This newly developed model indicates that the optimal detection velocity is independent of dissociation rate and depends on the distance to the barrier kinetic parameter. Therefore, the kinetic parameters of bond dissociation can be extracted from the dependence of detection probability on probe velocity and the detection threshold. This approach is sensitive to low rupture forces and therefore is complementary to the common most probable force data analysis approach. The developed approach is tested using rupture forces measured with specific bonds between biotin and streptavidin and with nonspecific bonds between linear alkanes in water. Results for the analysis of specific bonds rupture are consistent with the previous measurements, suggesting that rupture forces spanning a wide range of values originate from the same binding potential. Kinetic parameters obtained for linear alkanes are significantly different from previous measurements suggesting possible heterogeneity of the bound state.

6.
Biophys J ; 96(8): 3412-22, 2009 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-19383484

RESUMO

Single molecule force spectroscopy is often used to study the dissociation of single molecules by applying mechanical force to the intermolecular bond. These measurements provide the kinetic parameters of dissociation. We present what to our knowledge is a new atomic force microscopy-based approach to obtain the activation energy of the association reaction and approximate grafting density of reactive receptors using the dependence of the probability to form molecular bonds on probe velocity when one of the interacting molecules is tethered by a flexible polymeric linker to the atomic force microscopy probe. Possible errors in the activation energy measured with this approach are considered and resulting corrections are included in the data analysis. This new approach uses the same experimental setup as traditional force spectroscopy measurements that quantify dissociation kinetics. We apply the developed methodology to measure the activation energy of biotin-streptavidin association (including a contribution from the steric factor) and obtain a value of 8 +/- 1 kT. This value is consistent with the association rate measured previously in solution. Comparison with the solution-derived activation energy indicates that kinetics of biotin-streptavidin binding is mainly controlled by the reaction step.


Assuntos
Biotina/metabolismo , Modelos Moleculares , Ligação Proteica , Análise Espectral , Estreptavidina/metabolismo , Algoritmos , Cinética , Microscopia de Força Atômica , Movimento (Física) , Distribuição Normal , Probabilidade , Termodinâmica , Incerteza
7.
Biophys J ; 95(8): 3964-76, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18621812

RESUMO

Force spectroscopy measurements of the rupture of the molecular bond between biotin and streptavidin often results in a wide distribution of rupture forces. We attribute the long tail of high rupture forces to the nearly simultaneous rupture of more than one molecular bond. To decrease the number of possible bonds, we employed hydrophilic polymeric tethers to attach biotin molecules to the atomic force microscope probe. It is shown that the measured distributions of rupture forces still contain high forces that cannot be described by the forced dissociation from a deep potential well. We employed a recently developed analytical model of simultaneous rupture of two bonds connected by polymer tethers with uneven length to fit the measured distributions. The resulting kinetic parameters agree with the energy landscape predicted by molecular dynamics simulations. It is demonstrated that when more than one molecular bond might rupture during the pulling measurements there is a noise-limited range of probe velocities where the kinetic parameters measured by force spectroscopy correspond to the true energy landscape. Outside this range of velocities, the kinetic parameters extracted by using the standard most probable force approach might be interpreted as artificial energy barriers that are not present in the actual energy landscape. Factors that affect the range of useful velocities are discussed.


Assuntos
Biotina/metabolismo , Análise Espectral/métodos , Estreptavidina/metabolismo , Fenômenos Biomecânicos , Simulação por Computador , Cinética , Modelos Moleculares
8.
Photochem Photobiol ; 84(3): 671-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18399921

RESUMO

Atomic force microscope (AFM) imaging and nanoindentation measurements in water were used to probe the mechanical properties of retinal pigment epithelium melanosomes isolated from 14-year-old and 76-year-old donors. Topographic imaging reveals surface roughness similar to previous measurements on dry melanosomes. Force-indentation measurements show different types of responses that were catalogued into four different categories. In these measurements no permanent surface damage of melanosomes was observed as revealed by imaging before and after indentation measurements. The indentation measurements that exhibited nearly elastic responses were used to determine the Young's modulus of melanosomes. The average Young's modulus values are similar for 14-year-old and 76-year-old melanosomes with a somewhat narrower distribution for the 14-year-old sample. These elastic modulus values are considerably higher than the modulus of organelles with cytoplasm (<1 MPa) and approaching values of the modulus of protein crystals (approximately 100 MPa) indicating rather high packing density of biologic material in melanosomes. The width of the Young's modulus distributions is considerable spanning from few megapascals to few tens of megapascals indicating large heterogeneity in the structure. A fraction of the force curves cannot be described by the homogeneous elastic sample model; these force curves are consistent with approximately 10 nm structural heterogeneity in melanosomes. The approach-withdraw hysteresis indicates a significant viscoelasticity, particularly in the samples from the 14-year-old sample. Adhesion of the AFM probe was detected on approximately 3% and approximately 20% of the surface of 14-year-old and 76-year-old samples, respectively. In light of previous studies on these same melanosomes using photoelectron emission microscopy, this adhesion is attributed to the presence of lipofuscin on the surface of the melanosomes. This suggestion indicates that part of the difference in photochemical properties between the old and young melanosomes originates from surface lipofuscin.


Assuntos
Melanossomas/química , Melanossomas/ultraestrutura , Microscopia de Força Atômica/métodos , Epitélio Pigmentado Ocular/ultraestrutura , Retina/ultraestrutura , Adolescente , Fatores Etários , Idoso , Elasticidade , Humanos , Propriedades de Superfície
9.
Langmuir ; 24(3): 880-7, 2008 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-18163652

RESUMO

Mechanical properties of protein crystals and aggregates depend on the conformational and structural properties of individual protein molecules as well as on the packing density and structure within solid materials. An atomic force microscopy (AFM)-based approach is developed to measure the elastic modulus of small protein crystals by nanoindentation and is applied to measure the elasticity of insulin crystals. The top face of the crystals deposited on mica substrates is identified as the (001) face. Insulin crystals exhibit a nearly elastic response during the compression cycle. The elastic modulus measured on the top face has asymmetric distribution with a significant width. This width is related to the uncertainty in the deflection sensitivity. A model that takes into account the distribution of the sensitivity values is used to correct the elastic modulus. Measurements performed in aqueous buffer on several crystals at different locations with three different AFM probes give a mean elastic modulus of 164 +/- 10 MPa. This value is close to the static elastic moduli of other protein crystals measured by different techniques that are usually measured in the range from 100 MPa to 1 GPa. The measured modulus of insulin crystals falls between the elastic modulus values of insulin amyloid fibrils measured previously at two orthogonal directions (a modulus of 14 MPa was measured by compressing the fibril in the direction perpendicular to the fibril axis, and a modulus of 3.3 GPa was measured in the direction along the fibril axis). This comparison indicates the heterogeneous structure of fibrils in the direction perpendicular to the fibril axis, with a packing density of the amyloid fibril core that is higher than the average packing density in insulin crystals. The mechanical wear of insulin crystals is detected during AFM measurements. In nanoindentation experiments on insulin crystal, the compressive load by the AFM tip ( approximately 1 nN, corresponding to a pressure of around 5 MPa) occasionally removes protein molecules from the top or the second top layer of insulin crystal in a sequential manner. The molecular model of this surface damage is proposed. In addition, the removal of the multiple layers of molecules is observed during the AC-mode imaging in aqueous buffer. The number of removed layers depends on the scan size.


Assuntos
Insulina/química , Animais , Fenômenos Biomecânicos , Bovinos , Cristalização , Elasticidade , Insulina/isolamento & purificação , Microscopia de Força Atômica , Complexos Multiproteicos , Conformação Proteica
10.
Biomacromolecules ; 7(5): 1630-6, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16677048

RESUMO

A nanoindentation approach based on atomic force microscopy was applied to test the elastic properties of insulin amyloid fibrils. Fibrils exhibited a nearly elastic response to the compressive load. The results, corrected for the finite sample thickness effect, reveal that the fibril Young's modulus is considerably lower than the modulus of protein crystals, suggesting lower packing density in amyloid fibrils. Variation in elasticity among and within fibrils has been studied, showing that the Young's moduli of insulin fibrils have a relatively wide distribution of values, ranging from 5 to 50 MPa. Amyloid fibrils with higher modulus were found to be more wear-resistant during AFM scanning. The measured distribution of elasticity values of different fibrils together with wear-resistance tests indicates structural heterogeneity among fibrils, whereas the structure of individual fibrils appears to be homogeneous. The relative simplicity of the method used in this study can facilitate rapid collection of quantitative information related to the packing density and heterogeneity of fibrils formed by different proteins.


Assuntos
Amiloide/química , Insulina/química , Animais , Bovinos , Cinética , Microscopia de Força Atômica , Nanotubos , Termodinâmica
11.
Biofouling ; 20(6): 279-89, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15804712

RESUMO

The properties of barnacle adhesive on silicone surfaces were studied by AFM indentation, imaging, and other tests and compared to the barnacle shear adhesion strength. A multilayered structure of barnacle adhesive plaque is proposed based on layered modulus regions measured by AFM indentation. The fracture of barnacles from PDMS surfaces was found to include both interfacial and cohesive failure of barnacle adhesive plaque, as determined by protein staining of the substratum after forced barnacle release from the substrate. Data for freshly released barnacles showed that there was a strong correlation between the mean Young's modulus of the outermost (softest) adhesive layer (E<0.3 MPa) and the shear strength of adhesion, but no correlation for other higher modulus regions. Linear, quadratic, and Griffith's failure criterion (based on rough estimate of crack length) regressions were used in the fit, and showed significance.


Assuntos
Adesivos/química , Thoracica/química , Animais , Microscopia de Força Atômica , Resistência ao Cisalhamento , Navios , Silicones/química
12.
J Chem Inf Comput Sci ; 42(3): 481-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12086505

RESUMO

This article described a 3D structure database of components extracted from Chinese Traditional Medicinal (CTM) herbs. It offers not only basic molecular properties and optimized 3D structure of the compounds but also detailed information on their herbal origin, including basic herbal category (e.g. English name, Latin name, and family), effective parts, and clinical effects. An easy to use, interactive GUI browser allows users to perform various searches via complex logical query builder. Combined with the latest network database engine (MySQL), it can achieve excellent performance under both a local network and an Internet environment. We have tested it on the design of inhibitors of NS3-NS4A protease. Results show that the structure database of components extracted from Chinese medicinal herbs can be a rich source in searching the lead compound.


Assuntos
Bases de Dados Factuais , Medicamentos de Ervas Chinesas , Medicina Tradicional Chinesa , Armazenamento e Recuperação da Informação , Modelos Moleculares , Estrutura Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...