Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Transl Oncol ; 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898352

RESUMO

OBJECTIVE: This study aimed to explore the effect of narrative nursing on improving the negative emotions, sleep quality, and quality of life of patients with moderate to severe cancer pain. METHODS: A total of 80 patients with moderate to severe cancer pain who had been hospitalized in the lymphoma oncology department in our hospital from March 2019 to September 2021 were selected as the study subjects and randomly divided into the conventional nursing and narrative nursing groups, with 40 cases in each group. A conventional nursing intervention was conducted for one group, and narrative nursing was provided for the second group in addition to the conventional nursing. The anxiety and depression, sleep quality, quality of life, and satisfaction with pain management of the patients in the two groups were compared before and after the intervention. RESULTS: In the narrative nursing group, the self-rating anxiety scale and self-rating depression scale scores were significantly lower than those in the conventional nursing group after the intervention (P < 0.05). The scores for sleep quality, sleep duration, sleep efficiency, and daytime dysfunction and the total Pittsburgh Sleep Quality Index scores were significantly lower in the narrative nursing group compared with the conventional care group (P < 0.05). The scores for the physical function, living ability, social adaptation, and psychological status items in the Quality of Life Questionnaire Core 30 were significantly higher in the narrative nursing group than in the conventional care group (P < 0.05). The patients' satisfaction with pain management was higher in the narrative nursing group than in the conventional care group (P < 0.05). CONCLUSION: Narrative nursing can alleviate the negative emotions of anxiety and depression in patients with moderate to severe cancer pain and improve their sleep quality, quality of life, and pain management satisfaction.

2.
J Ultrasound Med ; 42(2): 345-354, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35338721

RESUMO

OBJECTIVES: The present study aims to evaluate the clinical application values of ultrasound real-time shear wave elastography (SWE) in the diagnosis and differential diagnosis of cervical cancer (CC). METHODS: A total of 285 married female patients were screened and divided into three groups according to the results of the pathological examination and the cervical ThinPrep cytologic test: 1) the CC group (n = 94); 2) the cervical intraepithelial neoplasia (CIN) group (n = 91); and 3) the normal control group (n = 100). The maximum Young's modulus (Emax), mean Young's modulus (Emean), minimum Young's modulus (Emin), and Young's modulus stability (Esd) in each group were measured and statistically analyzed. RESULTS: There were no statistically significant differences in Emax, Emean, Emin, and Esd values between the anterior and posterior cervical walls, premenopausal and postmenopausal women, and nonparturient and parturient women in the normal control group. The Emax, Emean, Emin, and Esd values in the CIN group showed no statistically significant differences in different periods when compared with the control group. The differences between the normal control group and the CC group were statistically significant; the CC group showed no statistically significant differences in Emax, Emean, Emin, and Esd values at different clinical stages and in different pathological types. The cutoff value of Emax for CC diagnosis, which was of the highest accuracy (89.7%), was 43.48 kpa. CONCLUSION: Ultrasound real-time SWE can be applied to CC diagnosis.


Assuntos
Técnicas de Imagem por Elasticidade , Lesões Pré-Cancerosas , Neoplasias do Colo do Útero , Humanos , Feminino , Técnicas de Imagem por Elasticidade/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Colo do Útero/diagnóstico por imagem , Ultrassonografia , Módulo de Elasticidade , Lesões Pré-Cancerosas/diagnóstico por imagem
3.
Int J Gen Med ; 14: 2849-2856, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34211293

RESUMO

BACKGROUND: To explore the value of transvaginal real-time shear wave elastography (SWE) in the diagnosis of endometrial lesions. METHODS: A total of 140 female patients with endometrial lesions, confirmed by pathological results, were divided into three groups: 45 cases of endometrial polyps, 29 cases of endometrial hyperplasia and 66 cases of endometrial cancer. A total of 100 cases of normal endometrium were used as the control group, including 52 cases in the proliferative stage and 48 cases in the secretory stage. Transvaginal real-time shear wave elastography was performed in all four groups. RESULTS: Emean, Emax and Esd were expressed as the average standard deviation. Among the control group, the results were 26.24±9.74, 38.09±9.18, and 4.25±2.73 kPa, respectively, in the proliferative endometrium cases and 12.51±7.46, 27.22±11.32, 4.40±2.52 kPa, respectively, in the secretory endometrium cases. Among the experimental group, the result was 15.68±8.18, 27.28±10.28 and 3.62±1.81 kPa respectively in the endometrial polyps cases; 21.20 ± 12.57, 36.32 ± 15.04, and 5.09 ±3.93 kPa in the endometrial hyperplasia cases; 49.36±25.51, 86.66±42.27 and 14.86±10.63 kPa in the endometrial cancer cases. The difference was statistically significant (P <0.05). When the truncation values of Emean, Emax and Esd were 28.50, 52.45 and 9.05 kPa, respectively, to distinguish between normal endometrium and endometrial cancer, Emax has the highest diagnostic value. CONCLUSION: Real-time SWE technology might be used as an auxiliary method in the diagnosis and differential diagnosis of endometrial cancer. More quantitative indicators are conducive to diagnosis.

4.
J Ultrasound Med ; 40(9): 1851-1861, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33216384

RESUMO

OBJECTIVE: To explore the clinical value of real-time shear wave ultrasonic elastography in diagnosing the depth of infiltrating muscularis of endometrial cancer. METHODS: Seventy-one patients with stage I endometrial cancer infiltrating the myometrium and 37 patients with normal physical examination were enrolled and divided into three groups: endometrial cancer superficial muscle infiltration group, endometrial cancer deep muscle infiltration group, and normal control group. After completing 2-dimensional ultrasound examination, each patient switched to the real-time shear wave elastography mode to measure the elasticity values Emax, Emean, and Esd. RESULTS: For control group, comparison of elastic modulus values between superficial muscular layer near the intimal surface and the deep muscular layer near the serosa surface showed no difference (P > 0.05). For endometrial cancer superficial muscular infiltration group, significant difference was found regarding the elastic modulus values of infiltrated muscular layer and uninfiltrated muscular layer (Emax and Emean) without difference for Esd (P > 0.05). A significant difference of elastic modulus was observed between control group and deep myometrial infiltration group (P < 0.05) without difference of Emean or Emax but with difference of Esd. The accuracy in diagnosing muscular layer infiltration was 78.9% for Emax cutoff and 82.5% for Emean cutoff. The rate of using Emax ≥32.22 kPa or Emean ≥27.54 kPa as the ultrasound standard for diagnosing myometrium infiltration was 92.9%. The accuracy for the diagnosis of muscular layer infiltration was 96.1% for Emax cutoff, 94.1% for Emean cutoff and 86.3% for Esd cutoff. CONCLUSION: Real-time shear wave elastography is helpful to determine the depth of infiltrating myometrium of endometrial cancer.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias do Endométrio , Diagnóstico Diferencial , Módulo de Elasticidade , Neoplasias do Endométrio/diagnóstico por imagem , Feminino , Humanos , Miométrio/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...