Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Radiol Bras ; 57: e20230125, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38993969

RESUMO

Objective: To evaluate the diagnostic accuracy of multi-echo Dixon magnetic resonance imaging (MRI) in hepatic fat quantification, in comparison with that of magnetic resonance spectroscopy (MRS), on 3.0-T MRI. Materials and Methods: Fifty-five adults with no known liver disease underwent MRI in a 3.0-T scanner for determination of the hepatic fat fraction, with two techniques: multi-echo Dixon, in a manually drawn region of interest (ROI) and in the entire liver parenchyma (automated segmentation); and MRS. The diagnostic accuracy and cutoff value for multi-echo Dixon were determined, with MRS being used as the reference standard. Results: The mean fat fraction obtained by multi-echo Dixon in the manually drawn ROI and in the entire liver was 5.2 ± 5.8% and 6.6 ± 5.2%, respectively, whereas the mean hepatic fat fraction obtained by MRS was 5.7 ± 6.4%. A very strong positive correlation and good agreement were observed between MRS and multi-echo Dixon, for the ROI (r = 0.988, r2 = 0.978, p < 0.001) and for the entire liver parenchyma (r = 0.960, r2 = 0.922, p < 0.001). A moderate positive correlation was observed between the hepatic fat fraction and body mass index of the participants, regardless of the fat estimation technique employed. Conclusion: For hepatic fat quantification, multi-echo Dixon MRI demonstrated a very strong positive correlation and good agreement with MRS (often considered the gold-standard noninvasive technique). Because multi-echo Dixon MRI is more readily available than is MRS, it can be used as a rapid tool for hepatic fat quantification, especially when the hepatic fat distribution is not homogeneous.


Objetivo: Avaliar a acurácia diagnóstica da técnica multieco Dixon na quantificação da gordura hepática em comparação com a espectroscopia por ressonância magnética (ERM), em exames de RM 3.0-T. Materiais e Métodos: Cinquenta e cinco participantes adultos sem doença hepática conhecida foram submetidos a RM 3.0-T para determinação da fração de gordura hepática, usando duas técnicas: multieco Dixon (em ROI desenhada manualmente e em segmentação automatizada para todo o parênquima hepático) e ERM. A precisão diagnóstica e o valor de corte para multieco Dixon foram determinados usando a ERM como padrão de referência. Resultados: A fração de gordura média usando multieco Dixon na ROI desenhada manualmente e na segmentação automatizada do fígado inteiro foi 5,2 ± 5,8% e 6,6 ± 5,2%, respectivamente. A fração de gordura hepática média usando ERM foi 5,7 ± 6,4%. Correlação positiva muito alta e forte concordância foram observadas entre ERM e multieco Dixon, tanto para ROI (r = 0,988, r2 = 0,978, p < 0,001) quanto para todo o parênquima hepático (r = 0,960, r2 = 0,922, p < 0,001). Correlação positiva moderada foi observada entre a fração de gordura hepática e o índice de massa corpórea dos participantes usando ambas as técnicas de estimativa de gordura. Conclusão: Multieco Dixon demonstrou correlação positiva muito alta e concordância com a ERM (muitas vezes considerada padrão de referência não invasivo) para quantificação de gordura hepática. Uma vez que o multieco Dixon está mais prontamente disponível do que a ERM, pode ser usado como uma ferramenta rápida para a quantificação da gordura hepática, especialmente na distribuição não homogênea da gordura.

2.
Radiol. bras ; 57: e20230125, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558816

RESUMO

Abstract Objective: To evaluate the diagnostic accuracy of multi-echo Dixon magnetic resonance imaging (MRI) in hepatic fat quantification, in comparison with that of magnetic resonance spectroscopy (MRS), on 3.0-T MRI. Materials and Methods: Fifty-five adults with no known liver disease underwent MRI in a 3.0-T scanner for determination of the hepatic fat fraction, with two techniques: multi-echo Dixon, in a manually drawn region of interest (ROI) and in the entire liver parenchyma (automated segmentation); and MRS. The diagnostic accuracy and cutoff value for multi-echo Dixon were determined, with MRS being used as the reference standard. Results: The mean fat fraction obtained by multi-echo Dixon in the manually drawn ROI and in the entire liver was 5.2 ± 5.8% and 6.6 ± 5.2%, respectively, whereas the mean hepatic fat fraction obtained by MRS was 5.7 ± 6.4%. A very strong positive correlation and good agreement were observed between MRS and multi-echo Dixon, for the ROI (r = 0.988, r2 = 0.978, p < 0.001) and for the entire liver parenchyma (r = 0.960, r2 = 0.922, p < 0.001). A moderate positive correlation was observed between the hepatic fat fraction and body mass index of the participants, regardless of the fat estimation technique employed. Conclusion: For hepatic fat quantification, multi-echo Dixon MRI demonstrated a very strong positive correlation and good agreement with MRS (often considered the gold-standard noninvasive technique). Because multi-echo Dixon MRI is more readily available than is MRS, it can be used as a rapid tool for hepatic fat quantification, especially when the hepatic fat distribution is not homogeneous.


Resumo Objetivo: Avaliar a acurácia diagnóstica da técnica multieco Dixon na quantificação da gordura hepática em comparação com a espectroscopia por ressonância magnética (ERM), em exames de RM 3.0-T. Materiais e Métodos: Cinquenta e cinco participantes adultos sem doença hepática conhecida foram submetidos a RM 3.0-T para determinação da fração de gordura hepática, usando duas técnicas: multieco Dixon (em ROI desenhada manualmente e em segmentação automatizada para todo o parênquima hepático) e ERM. A precisão diagnóstica e o valor de corte para multieco Dixon foram determinados usando a ERM como padrão de referência. Resultados: A fração de gordura média usando multieco Dixon na ROI desenhada manualmente e na segmentação automatizada do fígado inteiro foi 5,2 ± 5,8% e 6,6 ± 5,2%, respectivamente. A fração de gordura hepática média usando ERM foi 5,7 ± 6,4%. Correlação positiva muito alta e forte concordância foram observadas entre ERM e multieco Dixon, tanto para ROI (r = 0,988, r2 = 0,978, p < 0,001) quanto para todo o parênquima hepático (r = 0,960, r2 = 0,922, p < 0,001). Correlação positiva moderada foi observada entre a fração de gordura hepática e o índice de massa corpórea dos participantes usando ambas as técnicas de estimativa de gordura. Conclusão: Multieco Dixon demonstrou correlação positiva muito alta e concordância com a ERM (muitas vezes considerada padrão de referência não invasivo) para quantificação de gordura hepática. Uma vez que o multieco Dixon está mais prontamente disponível do que a ERM, pode ser usado como uma ferramenta rápida para a quantificação da gordura hepática, especialmente na distribuição não homogênea da gordura.

3.
Acta Radiol ; 64(4): 1641-1649, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36254401

RESUMO

Rhino-orbito-cerebral mucormycosis is a potentially fatal disease requiring early magnetic resonance imaging (MRI) for disease evaluation and timely detection of intracranial complications. Angio-invasive nature leading to necrosis and infarction is the hallmark of mucormycosis. The disease follows a fulminant course extending from the paranasal sinuses to involve the orbit, deep neck spaces, skull base, facial bones, and intracranial compartment. Loss of vision either due to direct extension into the orbit or optic nerve infarction adds to disease morbidity. Prompt MRI using dedicated sequences can help in assessing the exact disease extent including early osseous and intracranial changes, which aid in precise disease management.


Assuntos
Mucormicose , Doenças Orbitárias , Seios Paranasais , Humanos , Mucormicose/diagnóstico por imagem , Mucormicose/complicações , Doenças Orbitárias/diagnóstico por imagem , Imageamento por Ressonância Magnética/efeitos adversos , Infarto/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...