1.
Sci Rep ; 8(1): 11645, 2018 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-30076356

RESUMO

Respiratory diseases such as asthma and chronic obstructive pulmonary disease (COPD), are affecting a huge percentage of the world's population with mortality rates exceeding those of lung cancer and breast cancer combined. The major challenge is the number of patients who are incorrectly diagnosed. To address this, we developed an expert diagnostic system that can differentiate among patients with asthma, COPD or a normal lung function based on measurements of lung function and information about patient's symptoms. To develop accurate classification algorithms, data from 3657 patients were used and then independently verified using data from 1650 patients collected over a period of two years. Our results demonstrate that the expert diagnostic system can correctly identify patients with asthma and COPD with sensitivity of 96.45% and specificity of 98.71%. Additionally, 98.71% of the patients with a normal lung function were correctly classified, which contributed to a 49.23% decrease in demand for conducting additional tests, therefore decreasing financial cost.


Assuntos
Asma/diagnóstico , Diagnóstico Diferencial , Pulmão/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Adulto , Algoritmos , Asma/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Espirometria
2.
J Am Med Inform Assoc ; 25(9): 1213-1217, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29788482

RESUMO

This paper presents the development and real-time testing of an automated expert diagnostic telehealth system for the diagnosis of 2 respiratory diseases, asthma and Chronic Obstructive Pulmonary Disease (COPD). The system utilizes Android, Java, MATLAB, and PHP technologies and consists of a spirometer, mobile application, and expert diagnostic system. To evaluate the effectiveness of the system, a prospective study was carried out in 3 remote primary healthcare institutions, and one hospital in Bosnia and Herzegovina healthcare system. During 6 months, 780 patients were assessed and diagnosed with an accuracy of 97.32%. The presented approach is simple to use and offers specialized consultations for patients in remote, rural, and isolated communities, as well as old and less physically mobile patients. While improving the quality of care delivered to patients, it was also found to be very beneficial in terms of healthcare.


Assuntos
Asma/diagnóstico , Sistemas Inteligentes , Aplicativos Móveis , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Telemedicina , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Espirometria
3.
BMC Med Genomics ; 11(1): 19, 2018 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-29439729

RESUMO

BACKGROUND: The usage of Artificial Neural Networks (ANNs) for genome-enabled classifications and establishing genome-phenotype correlations have been investigated more extensively over the past few years. The reason for this is that ANNs are good approximates of complex functions, so classification can be performed without the need for explicitly defined input-output model. This engineering tool can be applied for optimization of existing methods for disease/syndrome classification. Cytogenetic and molecular analyses are the most frequent tests used in prenatal diagnostic for the early detection of Turner, Klinefelter, Patau, Edwards and Down syndrome. These procedures can be lengthy, repetitive; and often employ invasive techniques so a robust automated method for classifying and reporting prenatal diagnostics would greatly help the clinicians with their routine work. METHODS: The database consisted of data collected from 2500 pregnant woman that came to the Institute of Gynecology, Infertility and Perinatology "Mehmedbasic" for routine antenatal care between January 2000 and December 2016. During first trimester all women were subject to screening test where values of maternal serum pregnancy-associated plasma protein A (PAPP-A) and free beta human chorionic gonadotropin (ß-hCG) were measured. Also, fetal nuchal translucency thickness and the presence or absence of the nasal bone was observed using ultrasound. RESULTS: The architectures of linear feedforward and feedback neural networks were investigated for various training data distributions and number of neurons in hidden layer. Feedback neural network architecture out performed feedforward neural network architecture in predictive ability for all five aneuploidy prenatal syndrome classes. Feedforward neural network with 15 neurons in hidden layer achieved classification sensitivity of 92.00%. Classification sensitivity of feedback (Elman's) neural network was 99.00%. Average accuracy of feedforward neural network was 89.6% and for feedback was 98.8%. CONCLUSION: The results presented in this paper prove that an expert diagnostic system based on neural networks can be efficiently used for classification of five aneuploidy syndromes, covered with this study, based on first trimester maternal serum screening data, ultrasonographic findings and patient demographics. Developed Expert System proved to be simple, robust, and powerful in properly classifying prenatal aneuploidy syndromes.


Assuntos
Biologia Computacional/métodos , Demografia , Mães , Redes Neurais de Computação , Primeiro Trimestre da Gravidez/sangue , Diagnóstico Pré-Natal , Adolescente , Adulto , Síndrome de Down/diagnóstico , Síndrome de Down/diagnóstico por imagem , Feminino , Humanos , Síndrome de Klinefelter/diagnóstico , Síndrome de Klinefelter/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Gravidez , Síndrome da Trissomia do Cromossomo 13/diagnóstico , Síndrome da Trissomia do Cromossomo 13/diagnóstico por imagem , Síndrome da Trissomía do Cromossomo 18/diagnóstico , Síndrome da Trissomía do Cromossomo 18/diagnóstico por imagem , Síndrome de Turner/diagnóstico , Síndrome de Turner/diagnóstico por imagem , Ultrassonografia , Adulto Jovem
4.
Med Arch ; 71(4): 288-292, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28974852

RESUMO

INTRODUCTION: Major advancements in DNA sequencing methods introduced in the first decade of the new millennium initiated a rapid expansion of sequencing studies, which yielded a tremendous amount of DNA sequence data, including whole sequenced genomes of various species, including plants. A set of novel sequencing platforms, often collectively named as "next-generation sequencing" (NGS) completely transformed the life sciences, by allowing extensive throughput, while greatly reducing the necessary time, labor and cost of any sequencing endeavor. PURPOSE: of this paper is to present an overview NGS platforms used to produce the current compendium of published draft genomes of various plants, namely the Roche/454, ABI/SOLiD, and Solexa/Illumina, and to determine the most frequently used platform for the whole genome sequencing of plants in light of genotypization of immortelle plant. MATERIALS AND METHODS: 45 papers were selected (with 47 presented plant genome draft sequences), and utilized sequencing techniques and NGS platforms (Roche/454, ABI/SOLiD and Illumina/Solexa) in selected papers were determined. Subsequently, frequency of usage of each platform or combination of platforms was calculated. RESULTS: Illumina/Solexa platforms are by used either as sole sequencing tool in 40.42% of published genomes, or in combination with other platforms - additional 48.94% of published genomes, followed by Roche/454 platforms, used in combination with traditional Sanger sequencing method (10.64%), and never as a sole tool. ABI/SOLiD was only used in combination with Illumina/Solexa and Roche/454 in 4.25% of publications. CONCLUSIONS: Illumina/Solexa platforms are by far most preferred by researchers, most probably due to most affordable sequencing costs. Taking into consideration the current economic situation in the Balkans region, Illumina Solexa is the best (if not the only) platform choice if the sequencing of immortelle plant (Helichrysium arenarium) is to be performed by the researchers in this region.


Assuntos
Genoma de Planta/genética , Helichrysum , Análise de Sequência de DNA/métodos , Helichrysum/genética , Sequenciamento de Nucleotídeos em Larga Escala , Especificidade da Espécie
5.
J Med Syst ; 41(9): 133, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28752483

RESUMO

To improve the quality of patient treatment by improving the functionality of medical devices in healthcare institutions. To present the results of the safety and performance inspection of patient-relevant output parameters of anesthesia machines and defibrillators defined by legal metrology. This study covered 130 anesthesia machines and 161 defibrillators used in public and private healthcare institutions, during a period of two years. Testing procedures were carried out according to international standards and legal metrology legislative procedures in Bosnia and Herzegovina. The results show that in 13.84% of tested anesthesia machine and 14.91% of defibrillators device performance is not in accordance with requirements and should either have its results be verified, or the device removed from use or scheduled for corrective maintenance. Research emphasizes importance of independent safety and performance inspections, and gives recommendations for the frequency of inspection based on measurements. Results offer implications for adequacy of preventive and corrective maintenance performed in healthcare institutions. Based on collected data, the first digital electronical database of anesthesia machines and defibrillators used in healthcare institutions in Bosnia and Herzegovina is created. This database is a useful tool for tracking each device's performance over time.


Assuntos
Anestesia , Desfibriladores
6.
Technol Health Care ; 25(2): 237-250, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28387686

RESUMO

The medical device industry has grown rapidly and incessantly over the past century. The sophistication and complexity of the designed instrumentation is nowadays rising and, with it, has also increased the need to develop some better, more effective and efficient maintenance processes, as part of the safety and performance requirements. This paper presents the results of performance tests conducted on 50 mechanical ventilators and 50 infant incubators used in various public healthcare institutions. Testing was conducted in accordance to safety and performance requirements stated in relevant international standards, directives and legal metrology policies. Testing of output parameters for mechanical ventilators was performed in 4 measuring points while testing of output parameters for infant incubators was performed in 7 measuring points for each infant incubator. As performance criteria, relative error of output parameters for mechanical ventilators and absolute error of output parameters for infant incubators was calculated. The ranges of permissible error, for both groups of devices, are regulated by the Rules on Metrological and Technical Requirements published in the Official Gazette of Bosnia and Herzegovina No. 75/14, which are defined based on international recommendations, standards and guidelines. All ventilators and incubators were tested by etalons calibrated in an ISO 17025 accredited laboratory, which provides compliance to international standards for all measured parameters.The results show that 30% of the tested medical devices are not operating properly and should be serviced, recalibrated and/or removed from daily application.


Assuntos
Incubadoras para Lactentes/normas , Ventiladores Mecânicos/normas , Falha de Equipamento , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Segurança do Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...